Search NASA⌕ Search

SEARCH · Search NASA

Results for “image based modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Realistic galaxy image simulation via score-based generative models

ABSTRACT We show that a denoising diffusion probabilistic model (DDPM), a class of score-based generative model, can be used to produce realistic mock images that mimic observations of galaxies. Our method is tested with Dark Energy Spectroscopic Instrument (DESI) grz imaging of galaxies from the Photometry and Rotation curve OBservations from Extragalactic Surveys (PROBES) sample and galaxies selected from the Sloan Digital Sky Survey. Subjectively, the generated galaxies are highly realistic when compared with samples from the real data set. We quantify the similarity by borrowing from the deep generative learning literature, using the ‘Fréchet inception distance’ to test for subjective and morphological similarity. We also introduce the ‘synthetic galaxy distance’ metric to compare the emergent physical properties (such as total magnitude, colour, and half-light radius) of a ground truth parent and synthesized child data set. We argue that the DDPM approach produces sharper and more realistic images than other generative methods such as adversarial networks (with the downside of more costly inference), and could be used to produce large samples of synthetic observations tailored to a specific imaging survey. We demonstrate two potential uses of the DDPM: (1) accurate inpainting of occluded data, such as satellite trails, and (2) domain transfer, where new input images can be processed to mimic the properties of the DDPM training set. Here we ‘DESI-fy’ cartoon images as a proof of concept for domain transfer. Finally, we suggest potential applications for score-based approaches that could motivate further research on this topic within the astronomical community.

79 ASTRONOMY AND ASTROPHYSICS↗

A crystal plasticity-based study of the relationship between microstructure and ultra-high-cycle fatigue life in nickel titanium alloys

Nickel Titanium (NiTi) alloys are often used in biomedical devices where failure due to mechanical fatigue is common. For other alloy systems, computational models have proven an effective means of determining the relationship between microstructural features and fatigue life. This work will extend the subset of those models which were based on crystal plasticity to examine the relationship between microstructure and fatigue life in NiTi alloys. It will explore the interaction between a spherical inclusion and the material’s free surface along with several NiTi microstructures reconstructed from 3D imaging. This work will determine the distance at which the free surface interacts with an inclusion and the effect of applied strain of surface-inclusion interaction. The effects of inclusion-inclusion interaction, matrix voiding, and matrix strengthening are explored and ranked with regards to their influence on fatigue life.

36 MATERIALS SCIENCE↗

Representative volume element model of lithium-ion battery electrodes based on X-ray nano-tomography

For this, a new model that keeps all major advantages of the single-particle model of lithium-ion batteries (LIBs) and includes three-dimensional structure of the electrode was developed. Unlike the single spherical particle, this model considers a small volume element of an electrode, called the Representative Volume Element (RVE), which represent the real electrode structure. The advantages of using RVE as the model geometry was demonstrated for a typical LIB electrode consisting of nano-particle LiFePO 4 (LFP) active material. The three-dimensional morphology of the LFP electrode was reconstructed using a synchrotron X-ray nano-computed tomography at the Advanced Photon Source of the Argonne National. A 27 μm 3 cube from reconstructed structure was chosen as the RVE for the simulation purposes. The model was employed to predict the voltage curve in a half-cell during galvanostatic operations and validated with experimental data. The simulation results showed that the distribution of lithium inside the electrode microstructure is very different from the results obtained based on the single-particle model. The range of lithium concentration is found to be much greater, successfully illustrates the effect of microstructure heterogeneity.

25 ENERGY STORAGE↗

Anchoring

This software provides methods and functions for training deep image classification models based on the principle of anchoring. It features a user-friendly PyTorch wrapper that facilitates the easy conversion of any model into an anchored model. The software supports various standard datasets and includes scripts for conducting evaluations. Developed with PyTorch, it is compatible with common neural network architectures used for image data. Additionally, it offers tools for computing evaluation metrics to assess model performance.

Narayanaswamy, Vivek Sivaraman↗

Fast transit portal dosimetry using density-scaled layer modeling of aSi-based electronic portal imaging device and Monte Carlo method

Purpose: Fast and accurate transit portal dosimetry was investigated by developing a density-scaled layer model of electronic portal imaging device (EPID) and applying it to a clinical environment. Methods: The model was developed for fast Monte Carlo dose calculation. The model was validated through comparison with measurements of dose on EPID using first open beams of varying field sizes under a 20-cm-thick flat phantom. After this basic validation, the model was further tested by applying it to transit dosimetry and dose reconstruction that employed our predetermined dose-response-based algorithm developed earlier. The application employed clinical intensity-modulated beams irradiated on a Rando phantom. The clinical beams were obtained through planning on pelvic regions of the Rando phantom simulating prostate and large pelvis intensity modulated radiation therapy. To enhance agreement between calculations and measurements of dose near penumbral regions, convolution conversion of acquired EPID images was alternatively used. In addition, thickness-dependent image-to-dose calibration factors were generated through measurements of image and calculations of dose in EPID through flat phantoms of various thicknesses. The factors were used to convert acquired images in EPID into dose. Results: For open beam measurements, the model showed agreement with measurements in dose difference better than 2% across open fields. For tests with a Rando phantom, the transit dosimetry measurements were compared with forwardly calculated doses in EPID showing gamma pass rates between 90.8% and 98.8% given 4.5 mm distance-to-agreement (DTA) and 3% dose difference (DD) for all individual beams tried in this study. The reconstructed dose in the phantom was compared with forwardly calculated doses showing pass rates between 93.3% and 100% in isocentric perpendicular planes to the beam direction given 3 mm DTA and 3% DD for all beams. On isocentric axial planes, the pass rates varied between 95.8% and 99.9% for all individual beams and they were 98.2% and 99.9% for the composite beams of the small and large pelvis cases, respectively. Three-dimensional gamma pass rates were 99.0% and 96.4% for the small and large pelvis cases, respectively. Conclusions: The layer model of EPID built for Monte Carlo calculations offered fast (less than 1 min) and accurate calculation for transit dosimety and dose reconstruction.

60 APPLIED LIFE SCIENCES↗

Morphological and Electrochemical Characterization of Nanostructured Li 4 Ti 5 O 12 Electrodes Using Multiple Imaging Mode Synchrotron X-ray Computed Tomography

In this study, synchrotron X-ray computed tomography has been utilized using two different imaging modes, absorption and Zernike phase contrast, to reconstruct the real three-dimensional (3D) morphology of nanostructured Li 4 Ti 5 O 12 (LTO) electrodes. The morphology of the high atomic number active material has been obtained using the absorption contrast mode, whereas the percolated solid network composed of active material and carbon-doped polymer binder domain (CBD) has been obtained using the Zernike phase contrast mode. The 3D absorption contrast image revealed that some LTO nano-particles tend to agglomerate and form secondary micro-sized particles with varying degrees of sphericity. The tortuosity of electrode’s pore and solid phases were found to have directional dependence, different from Bruggeman’s tortuosity commonly used in macro-homogeneous models. The electrode’s heterogeneous structure was investigated by developing a numerical model to simulate galvanostatic discharge process using the Zernike phase contrast mode. The inclusion of CBD in the Zernike phase contrast results in an integrated percolated network of active material and CBD that is highly suited for continuum modeling. As a result, the simulation results highlight the importance of using the real 3D geometry since the spatial distribution of physical and electrochemical properties have a strong non-uniformity due to microstructural heterogeneities.

25 ENERGY STORAGE↗

Comparison of signal to noise ratios from spatial and frequency domain formulations of nonprewhitening model observers in digital mammography

Purpose: Image quality indices based upon model observers are promising alternatives to laborious human readings of contrast-detail images. This is especially appealing in digital mammography as limiting values for contrast thresholds determine, according to some international protocols, the acceptability of these systems in the radiological practice. The objective of the present study was to compare the signal to noise ratios (SNR) obtained with two nonprewhitening matched filter model observer approaches, one in the spatial domain and the other in the frequency domain, and with both of them worked out for disks as present in the CDMAM phantom. Methods: The analysis was performed using images acquired with the Siemens Novation and Inspiration digital mammography systems. The spatial domain formulation uses a series of high dose CDMAM images as the signal and a routine exposure of two flood images to calculate the covariance matrix. The frequency domain approach uses the mathematical description of a disk and modulation transfer function (MTF) and noise power spectrum (NPS) calculated from images. Results: For both systems most of the SNR values calculated in the frequency domain were in very good agreement with the SNR values calculated in the spatial domain. Both the formulations in the frequency domain and in the spatial domain show a linear relationship between SNR and the diameter of the CDMAM discs. Conclusions: The results suggest that both formulations of the model observer lead to very similar figures of merit. This is a step forward in the adoption of figures of merit based on NPS and MTF for the acceptance testing of mammography systems.

60 APPLIED LIFE SCIENCES↗

Assessing the carbon sequestration potential of basalt using X-ray micro-CT and rock mechanics

Mineral carbonation in basaltic rock provides a permanent storage solution for the mitigation of anthropogenic CO 2 emissions in the atmosphere. 3D X-ray micro-CT (XCT) image analysis is applied to a core sample from the main basaltic reservoir of the CarbFix site in Iceland, which obtained a connected porosity of 2.05–8.76%, a reactive surface area of 0.10–0.33 mm -1 and a larger vertical permeability (2.07 × 10 -10 m 2 ) compared to horizontal permeability (5.10 × 10 -11 m 2 ). The calculations suggest a CO 2 storage capacity of 0.33 Gigatonnes at the CarbFix pilot site. The XCT results were compared to those obtained from a hydromechanical test applied to the same sample, during which permeability, electrical resistivity and volumetric deformation were measured under realistic reservoir pressure conditions. It was found that permeability is highly stress sensitive, dropping by two orders of magnitude for a -0.02% volumetric deformation change, equivalent to a mean pore diameter reduction of 5 μm. This pore contraction was insufficient to explain such a permeability reduction according to the XCT analysis, unless combined with the effects of clay swelling and secondary mineral pore clogging. Here the findings provide important benchmark data for the future upscaling and optimisation of CO 2 storage in basalt formations.

58 GEOSCIENCES↗

Rectal Motion in Patients Receiving Preoperative Radiotherapy for Carcinoma of the Rectum

Purpose: To assess the movement of rectum, mesorectum, and rectal primary during a course of preoperative chemoradiotherapy. Methods and Materials: Seventeen patients with Stage II or III rectal cancer had a planning CT scan with rectal contrast before commencement of preoperative chemoradiation. The scan was repeated during Weeks 1, 3, and 5 of chemoradiation. The rectal primary (gross tumor volume), rectum, mesorectum, and bladder were contoured on all four scans. An in-house biomechanical model-based deformable image registration technique, Morfeus, was used to measure the three-dimensional spatial change in these structures after bony alignment. The required planning target volume margin for this spatial change, after bone alignment, was also calculated. Results: Rectal contrast was found to introduce a systematic error in the position of all organs compared with the noncontrast state. The largest change in structures during radiotherapy was in the anterior and posterior directions for the mesorectum and rectum and in the superior and inferior directions for the gross tumor volume. The planning target volume margins required for internal movement for the mesorectum based on the three scans acquired during treatment are 4 mm right, 5 mm left, 7 mm anterior, and 6 mm posterior. For the rectum, values were 8 mm right, 8 mm left, 8 mm anterior, and 9 mm posterior. The greatest movement of the rectum occurred in the upper third. Conclusions: Contrast is no longer used in CT simulation. Assuming bony alignment, a nonuniform margin of 8 mm anteriorly, 9 mm posteriorly, and 8 mm left and right is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accumulated Dose in Liver Stereotactic Body Radiotherapy: Positioning, Breathing, and Deformation Effects

Purpose: To investigate the accumulated dose deviations to tumors and normal tissues in liver stereotactic body radiotherapy (SBRT) and investigate their geometric causes. Methods and Materials: Thirty previously treated liver cancer patients were retrospectively evaluated. Stereotactic body radiotherapy was planned on the static exhale CT for 27-60 Gy in 6 fractions, and patients were treated in free-breathing with daily cone-beam CT guidance. Biomechanical model-based deformable image registration accumulated dose over both the planning four-dimensional (4D) CT (predicted breathing dose) and also over each fraction's respiratory-correlated cone-beam CT (accumulated treatment dose). The contribution of different geometric errors to changes between the accumulated and predicted breathing dose were quantified. Results: Twenty-one patients (70%) had accumulated dose deviations relative to the planned static prescription dose >5%, ranging from -15% to 5% in tumors and -42% to 8% in normal tissues. Sixteen patients (53%) still had deviations relative to the 4D CT-predicted dose, which were similar in magnitude. Thirty-two tissues in these 16 patients had deviations >5% relative to the 4D CT-predicted dose, and residual setup errors (n = 17) were most often the largest cause of the deviations, followed by deformations (n = 8) and breathing variations (n = 7). Conclusion: The majority of patients had accumulated dose deviations >5% relative to the static plan. Significant deviations relative to the predicted breathing dose still occurred in more than half the patients, commonly owing to residual setup errors. Accumulated SBRT dose may be warranted to pursue further dose escalation, adaptive SBRT, and aid in correlation with clinical outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-AB-207A-03: A CBCT Head Scanner for Point-Of-Care Imaging of Intracranial Hemorrhage

Purpose: This work reports the design, development, and first technical assessment of a cone-beam CT (CBCT) scanner developed specifically for imaging of acute intracranial hemorrhage (ICH) at the point of care, with target applications in diagnosis and monitoring of traumatic brain injury, stroke, and postsurgical hemorrhage. Methods: System design employed a task-based image quality model to quantify the influence of factors such as additive noise and high-gain (HG) detector readout on ICH detectability. Three bowtie filters with varying bare-beam attenuation strength and curvature were designed to enable HG readout without detector saturation, and a polyenergetic gain correction was developed to minimize artifacts from bowtie flood-field calibration. Image reconstruction used an iterative penalized weighted least squares (PWLS) method with artifact correction including Monte Carlo scatter estimation, Joseph-Spital beam hardening correction, and spatiotemporal deconvolution of detector glare and lag. Radiation dose was characterized for half-scan and full-scan protocols at various kV, and imaging performance was assessed in a head phantom presenting simulated ICH with diameter ranging 2–12 mm. Results: The image quality model guided system design and was validated by measurements on a CBCT imaging bench. Compared to low-gain readout without a bowtie filter, the combination of HG readout and a modest bowtie improved the contrast-to-noise ratio (CNR per unit square-root dose) by 20% in the center of the image but degraded noise performance near the periphery (20% reduction in CNR). Low-frequency bowtie artifacts (∼100 HU magnitude) were corrected by the polyenergetic gain correction. Image reconstructions on the prototype scanner demonstrate clear visibility of the smallest ICH insert (2 mm diameter) in both HG readout (with a bowtie) and dual-gain readout (without bowtie). Conclusion: Technical assessment of the prototype scanner suggests the capability for reliable visualization of small (2 mm), low-contrast (50 HU) ICH at <20 mGy dose and motivates translation to clinical studies, now underway. Xiaohui Wang and David Foos (co-authors) are employees of Carestream Health. Research funding support from Carestream Health.

60 APPLIED LIFE SCIENCES↗

A 3D global-to-local deformable mesh model based registration and anatomy-constrained segmentation method for image guided prostate radiotherapy

Purpose: In the external beam radiation treatment of prostate cancers, successful implementation of adaptive radiotherapy and conformal radiation dose delivery is highly dependent on precise and expeditious segmentation and registration of the prostate volume between the simulation and the treatment images. The purpose of this study is to develop a novel, fast, and accurate segmentation and registration method to increase the computational efficiency to meet the restricted clinical treatment time requirement in image guided radiotherapy. Methods: The method developed in this study used soft tissues to capture the transformation between the 3D planning CT (pCT) images and 3D cone-beam CT (CBCT) treatment images. The method incorporated a global-to-local deformable mesh model based registration framework as well as an automatic anatomy-constrained robust active shape model (ACRASM) based segmentation algorithm in the 3D CBCT images. The global registration was based on the mutual information method, and the local registration was to minimize the Euclidian distance of the corresponding nodal points from the global transformation of deformable mesh models, which implicitly used the information of the segmented target volume. The method was applied on six data sets of prostate cancer patients. Target volumes delineated by the same radiation oncologist on the pCT and CBCT were chosen as the benchmarks and were compared to the segmented and registered results. The distance-based and the volume-based estimators were used to quantitatively evaluate the results of segmentation and registration. Results: The ACRASM segmentation algorithm was compared to the original active shape model (ASM) algorithm by evaluating the values of the distance-based estimators. With respect to the corresponding benchmarks, the mean distance ranged from -0.85 to 0.84 mm for ACRASM and from -1.44 to 1.17 mm for ASM. The mean absolute distance ranged from 1.77 to 3.07 mm for ACRASM and from 2.45 to 6.54 mm for ASM. The volume overlap ratio ranged from 79% to 91% for ACRASM and from 44% to 80% for ASM. These data demonstrated that the segmentation results of ACRASM were in better agreement with the corresponding benchmarks than those of ASM. The developed registration algorithm was quantitatively evaluated by comparing the registered target volumes from the pCT to the benchmarks on the CBCT. The mean distance and the root mean square error ranged from 0.38 to 2.2 mm and from 0.45 to 2.36 mm, respectively, between the CBCT images and the registered pCT. The mean overlap ratio of the prostate volumes ranged from 85.2% to 95% after registration. The average time of the ACRASM-based segmentation was under 1 min. The average time of the global transformation was from 2 to 4 min on two 3D volumes and the average time of the local transformation was from 20 to 34 s on two deformable superquadrics mesh models. Conclusions: A novel and fast segmentation and deformable registration method was developed to capture the transformation between the planning and treatment images for external beam radiotherapy of prostate cancers. This method increases the computational efficiency and may provide foundation to achieve real time adaptive radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional model of intracellular and intercellular Ca2+ waves propagation in endothelial cells

Highlights: • Image-based 3D simulation model for intercellular and intracellular Ca{sup 2+} waves. • Metabolic reactions were divided into membrane and cytoplasm domains. • Ca{sup 2+} and IP{sub 3} diffused across the cell and gap junctions. • Ca{sup 2+} waves are propagated from focal stimulated point in numerical simulation. • Ca{sup 2+} wave speed was in agreement with those from cell culture experiments. Intracellular and intercellular Ca{sup 2+} waves play key roles in cellular functions, and focal stimulation triggers Ca{sup 2+} wave propagation from stimulation points to neighboring cells, involving localized metabolism reactions and specific diffusion processes. Among these, inositol 1,4,5-trisphosphate (IP{sub 3}) is produced at membranes and diffuses into the cytoplasm to release Ca{sup 2+} from endoplasmic reticulum (ER). In this study, we developed a three-dimensional (3D) simulation model for intercellular and intracellular Ca{sup 2+} waves in endothelial cells (ECs). 3D model of 2 cells was reconstructed from confocal microscopic images and was connected via gap junctions. Cells have membrane and cytoplasm domains, and metabolic reactions were divided into each domain. Finally, the intracellular and intercellular Ca{sup 2+} wave propagations were induced using microscopic stimulation and were compared between numerical simulations and experiments. The experiments showed that initial sharp increases in intracellular Ca{sup 2+} occurred approximately 0.3 s after application of stimuli. In addition, Ca{sup 2+} wave speeds remained constant in cells, with intracellular and intercellular speeds of approximately 35 and 15 μm/s, respectively. Simulations indicated initial increases in Ca{sup 2+} concentrations at points of stimulation, and these were then propagated across stimulated and neighboring cells. In particular, initial rapid increases in intracellular Ca{sup 2+} were delayed and subsequent intracellular and intercellular Ca{sup 2+} wave speeds were approximately 25 and 12 μm/s, respectively. Simulation results were in agreement with those from cell culture experiments, indicating the utility of our 3D model for investigations of intracellular and intercellular messaging in ECs.

60 APPLIED LIFE SCIENCES↗