Search NASA⌕ Search

SEARCH · Search NASA

Results for “image quality structure material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Physical processes in comets

Post-Halley comets are known to be irregular objects with most nucleus activity very localized and with the dust coma capable of fragmentation and apparently being a source of gas. Older, 1-D strategies which assume steady isotropic outflow of material can give poor time-and-space averaged results, at best. With 2-D data, images through interference filters, it is hoped that: dust structures can be seen that give evidence of the proper geometry for data reduction; gradients along the axes of symmetry and evidence of fragmentation can be studied; and that evidence for gas abundance gradients associated with the dust can be found. High quality data from brighter comets can then be used to suggest improved data reduction procedures for fainter ones. To obtain such data, large image-quality interference filters were procured for use with a charge coupled device (CCD) camera at Lick Observatory, where the scale of the 1 m Nickel reflector is ideal for brighter comets. Whenever possible, data is taken simultaneously with other telescopes and equipment, especially spectroscopy at the Lick 3 m or infrared photometry at the Infrared Telescope Facility (IRTF) on Mauna Kea.

Newburn, Ray L., Jr.↗

MO-FG-204-01: Improved Noise Suppression for Dual-Energy CT Through Entropy Minimization

Purpose: In dual energy CT (DECT), noise amplification during signal decomposition significantly limits the utility of basis material images. Since clinically relevant objects contain a limited number of materials, we propose to suppress noise for DECT based on image entropy minimization. An adaptive weighting scheme is employed during noise suppression to improve decomposition accuracy with limited effect on spatial resolution and image texture preservation. Methods: From decomposed images, we first generate a 2D plot of scattered data points, using basis material densities as coordinates. Data points representing the same material generate a highly asymmetric cluster. We orient an axis by minimizing the entropy in a 1D histogram of these points projected onto the axis. To suppress noise, we replace pixel values of decomposed images with center-of-mass values in the direction perpendicular to the optimal axis. To limit errors due to cluster overlap, we weight each data point’s contribution based on its high and low energy CT values and location within the image. The proposed method’s performance is assessed on physical phantom studies. Electron density is used as the quality metric for decomposition accuracy. Our results are compared to those without noise suppression and with a recently developed iterative method. Results: The proposed method reduces noise standard deviations of the decomposed images by at least one order of magnitude. On the Catphan phantom, this method greatly preserves the spatial resolution and texture of the CT images and limits induced error in measured electron density to below 1.2%. In the head phantom study, the proposed method performs the best in retaining fine, intricate structures. Conclusion: The entropy minimization based algorithm with adaptive weighting substantially reduces DECT noise while preserving image spatial resolution and texture. Future investigations will include extensive investigations on material decomposition accuracy that go beyond the current electron density calculations. This work was supported in part by the National Institutes of Health (NIH) under Grant Number R21 EB012700.

60 APPLIED LIFE SCIENCES↗

Atomic-Scale Characterization of Oxide Interfaces and Superlattices Using Scanning Transmission Electron Microscopy

Scanning transmission electron microscopy (STEM) has become one of the fundamental tools to characterize oxide interfaces and superlattices. Atomic-scale structure, chemistry, and composition mapping can now be conducted on a wide variety of materials systems thanks to the development of aberration-correctors and advanced detectors. STEM imaging and diffraction, coupled with electron energy loss (EELS) and energy-dispersive X-ray (EDS) spectroscopies, offer unparalleled, high-resolution analysis of structure-property relationships. In this chapter we highlight investigations into key phenomena, including interfacial conductivity in oxide superlattices, charge screening effects in magnetoelectric heterostructures, the design of high-quality iron oxide interfaces, and the complex physics governing atomic-scale chemical mapping. These studies illustrate how unique insights from STEM characterization can be integrated with other techniques and first-principles calculations to develop better models for the behavior of functional oxides.

Characterization↗

Toward Quality Control in Perovskite Solar Cell Fabrication: Spot-Like Processing Defects Disrupt Charge Transport Layers and Promote Ag Metal Electrode Intrusion

Metal halide perovskite (MHP) photovoltaics provide high efficiencies with less stringent processing requirements than traditional photovoltaic materials. However, processing related defects must be suppressed as they can lead to decreases in initial device efficiency and potentially compromise long-term device operation. In this work we investigate morphological defects in MHP devices using luminescence imaging followed by in-depth structural and composition analysis using electron microscopy-based methods. We identify several different classes of spot-like processing-related defects and observe that a single device structure may contain multiple types of these defects. The presence of these defects in devices with different layer structures and absorber chemistries makes them relevant to the perovskite photovoltaic community as a whole. The defects are associated with voids in the perovskite layer, inclusions (glass, migrated Ag, dust), thickness variations, hole transport layer disruption with anomalous crystal growth, and electron transport layer disruptions that could allow Ag intrusion and lead to local shunts. As perovskite photovoltaic technology matures, mitigation of such defects is critical to improving not only initial performance but also the long-term stability required for industrial applications.

14 SOLAR ENERGY↗

Pore Scale Analysis of Oil Shale/Sands Pyrolysis

There are important questions concerning the quality and volume of pore space that is created when oil shale is pyrolyzed for the purpose of producing shale oil. In this report, 1.9 cm diameter cores of Mahogany oil shale were pyrolyzed at different temperatures and heating rates. Detailed 3D imaging of core samples was done using multiscale X-ray computed tomography (CT) before and after pyrolysis to establish the pore structure. The pore structure of the unreacted material was not clear. Selected images of a core pyrolyzed at 400oC were obtained at voxel resolutions from 39 microns (Οm) to 60 nanometers (nm). Some of the pore space created during pyrolysis was clearly visible at these resolutions and it was possible to distinguish between the reaction products and the host shale rock. The pore structure deduced from the images was used in Lattice Boltzmann simulations to calculate the permeability in the pore space. The permeabilities of the pyrolyzed samples of the silicate-rich zone were on the order of millidarcies, while the permeabilities of the kerogen-rich zone after pyrolysis were very anisotropic and about four orders of magnitude higher.

04 OIL SHALES AND TAR SANDS↗

Multiphoton and Harmonic Imaging of Microarchitected Materials

Microadditive manufacturing has revolutionized the production of complex, nano- to microscale components across various fields. This work investigates two-photon (2P) and three-photon (3P) fluorescence imaging, as well as third-harmonic generation (THG) microscopy, to examine periodic microarchitected lattice structures fabricated using multiphoton lithography (MPL). By immersing the structures in refractive index matching fluids, we demonstrate high-fidelity 3D reconstructions of both fluorescent structures using 2P and 3P microscopy as well as low-fluorescence structures using THG microscopy. These results show that multiphoton fluorescence (MPF) imaging offers reduced signal decay with respect to depth compared to single-photon techniques in the examined structures. We further demonstrate the ability to nondestructively identify intentional internal modifications of the structure that are not immediately visible with scanning electron microscope (SEM) images and compression-induced fractures, highlighting the potential of these techniques for quality control and defect detection in microadditively manufactured components.

36 MATERIALS SCIENCE↗

Characterization of latent image of electron beam resist via critical-dimension resonant soft X-ray scattering

Metrology plays a crucial role in semiconductor manufacturing by providing accurate and precise measurement and characterization of critical parameters. With the development of high-resolution extreme ultraviolet lithography (EUVL) processes, critical dimensions are shrinking to sub-10 nm. Resist materials encounter the challenge of providing heightened sensitivity and a handle on exacerbating stochastic variations. A comprehensive understanding of the chemical profile of the latent image is pivotal for mitigating stochastic effects and optimizing pattern quality. However, the subtle differences in chemistry between the exposed and unexposed regions of the resists make it extremely challenging to characterize the latent images with sub-nanometer precision. Here, we develop the metrology with critical-dimension resonant soft X-ray scattering (CD-RSoXS) to probe the chemical profiles of latent images stored in resist after exposure. The combination of absorption spectroscopy and enhanced scattering contrast makes it possible to characterize the subtle structural and chemical variations in the latent image. Moreover, the results of the measurements are compared with the simulations with a finite element method–based Maxwell solver to extract a detailed profile of the latent and developed images. We demonstrate that the CD-RSoXS technique can provide valuable insights into the high spatial resolution and local chemical sensitivity simultaneously, which is crucial to understanding the resolution limits and stochastic effects in EUVL processes.

36 MATERIALS SCIENCE↗

Layer Time Control for Large Scale Additive Manufacturing Using High Performance Computing

This work proposes to optimize an additive manufacturing AM process to reduce energy and printing cost. The polymer AM process is inherently dependent on the time-temperature history of each layer to maintain geometric tolerances and mechanical integrity. Our preliminary study shows that regression-based layer time control model using thermal images could result in up to 30% build time reduction for simple geometries. This proposed work would use high-performance computing (HPC) to couple the data-driven model with thermal simulation for better predicting layer temperature profiles, improving throughput of large-scale additive manufacturing, and reducing its energy cost. We have developed a method to optimize a layer deposition time (a.k.a. layer time) for large-scale AM via physics-based simulations. A long layer time leads to an over-cooled surface on which a new layer is deposited, and therefore, it may result in a weak bonding or debonding between layers, cracking, or warping. A short layer time leads to a high temperature of the structure due to insufficient cooling, and therefore, the structure may not be stiff enough and may collapse during manufacturing. Therefore, it is important to estimate the optimal layer time in additive manufacturing for a high-quality product. The temperature of a top layer right before deposition is recommended to be slightly higher than the glass temperature of the material. A temperature cooling was approximated to an exponential function of time, and the optimized layer time was obtained based on a target temperature while maintaining a minimal printing time. The material used is carbon fiber-reinforced polycarbonate (CF/PC), and the large-scale deposition system used is LSAM TM from Thermwood Corporation. Three different layer time cases were used for experiments, and a series of thermal images were obtained via an infra-red (IR) camera during the entire AM processes. AM process simulations were performed using a finite element method and the temperature profiles from the simulation were in good agreements with those from experiments. The layer time optimization was performed based on the temperature profiles from the simulations. A layer temperature with the optimal layer time was confirmed as the target temperature through simulation. In addition to the development of a layer time optimization method, we have developed a numerical framework for AM simulation with element activations in sync with toolpath, based on an open source finite element framework, DEAL.II. A major portion of this work was presented at SAMPE 2022 Conference and Exhibition on May 2022, and published in Proceedings of SAMPE 2022.

42 ENGINEERING↗

Geological analysis and evaluation of ERTS-A imagery for the state of New Mexico

The author has identified the following significant results. Coverage of approximately one-third of the test site had been received by January 31, 1973 and all of the images received were MSS products. Images recorded during the first two months of the ERTS-1 mission were of poor quality, owing largely to high ground reflectance. Later images were of better quality and MSS bands 5 and 7 have proven to be particularly useful. Features noted during visual inspection of 9 1/2 x 9 1/2 prints include major structural forms, vegetation patterns, drainage patterns, and outcrops of geologic formations having marked color contrasts. The Border Hills Structural Zone and the Y-O Structural Zone are prominently reflected in coverage of the Pecos Valley. A study of available maps and remote sensing material covering the Deming-Columbus area indicated that the limit of detection and the resolution of MSS products are not as good as those of aerial photographs, geologic maps, and manned satellite photographs. The limit of detection of high contrast features on MSS prints is approximately 1000 feet or 300 meters for linear features and about 18 acres for roughly circular areas.

Kottlowski, F. E.↗

PhaseT3M: 3D imaging at 1.6 Å resolution via electron cryo-tomography with nonlinear phase retrieval

Electron cryo-tomography (cryo-ET) enables 3D imaging of complex, radiation-sensitive structures with molecular detail. However, image contrast from the interference of scattered electrons is nonlinear with atomic density and multiple scattering further complicates interpretation. These effects degrade resolution, particularly in conventional reconstruction algorithms, which assume linearity. Particle averaging can reduce such issues but is unsuitable for heterogeneous or dynamic samples ubiquitous in biology, chemistry, and materials sciences. Here, we develop a phase retrieval-based cryo-ET method, PhaseT3M. We experimentally demonstrate its application to an approximately 7 nm Co3O4 nanoparticle on an approximately 30 nm carbon substrate, achieving a maximum resolution of 1.6 Å, surpassing conventional limits using standard cryo-TEM equipment. PhaseT3M uses a multislice model for multiple scattering and Bayesian optimization for alignment and computational aberration correction, with a positivity constraint to recover ‘missing wedge’ information. Applied directly to biological particles, it enhances reconstruction quality and reduces artifacts, establishing a standard for routine 3D imaging with phase contrast.

Biophysics↗

Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power-law descriptions of the phantom images were in general agreement with real human images. The Singlet approach offered more realistic contrast as compared to the Doublet approach, but at the expense of air bubbles and air pockets that formed during the filling process. Conclusions: The presented physical breast phantoms and their matching virtual breast phantoms offer realistic breast anatomy, patient variability, and ease of use, making them a potential candidate for performing both system quality control testing and virtual clinical trials.

60 APPLIED LIFE SCIENCES↗

NanoPSD: A software for automatic detection of Nano-Particle Shape Distribution in electron microscopy images

Accurate quantification of the size and morphology of nanoparticles from electron microscopy (EM) images is essential to understand growth mechanisms, surface reactivity, and functional behavior in nanoscale materials. Manual analysis remains slow, subjective, and difficult to reproduce in large datasets. We introduce NanoPSD (Nano-Particle Shape Distribution), an open-source and fully automated framework for quantitative particle detection and morphology analysis from EM images. NanoPSD integrates adaptive contrast enhancement, polarity-agnostic scale-bar detection, Optical Character Recognition (OCR)-based calibration, and classical segmentation via Otsu thresholding with morphological refinement. Particle contours are used to extract geometric descriptors, including equivalent circular diameter, aspect ratio, circularity, and solidity, enabling automated classification into spherical, rod-like, and aggregate morphologies. The framework supports both single-image and batch processing, generating publication-quality visualizations, LaTeX-ready tables, and structured comma-separated values (CSV) datasets. As a demonstration, we applied NanoPSD to plasma-synthesized nanoparticle samples diagnosed via transmission electron microscopy (TEM). The code produced statistically robust size and morphology distributions spanning a few to tens of nanometers with minimal user supervision. The pipeline demonstrates high reproducibility and scalability, processing large image collections with consistent calibration and output formatting. Its modular design enables seamless integration of future deep-learning-based segmentation models, providing a pathway toward intelligent, data-driven electron microscopy analysis.

36 MATERIALS SCIENCE↗

Volumetric Modulated Arc-Based Hypofractionated Stereotactic Radiotherapy for the Treatment of Selected Intracranial Arteriovenous Malformations: Dosimetric Report and Early Clinical Experience

Purpose: To evaluate, with a dosimetric and clinical feasibility study, RapidArc (a volumetric modulated arc technique) for hypofractionated stereotactic radiotherapy treatment of large arteriovenous malformations (AVMs). Methods and Materials: Nine patients were subject to multimodality imaging (magnetic resonance, computed tomography, and digital subtraction angiography) to determine nidus and target volumes, as well as involved organs at risk (optical structures, inner ear, brain stem). Plans for multiple intensity-modulated arcs with a single isocenter were optimized for a fractionation of 25 Gy in 5 fractions. All plans were optimized for 6-MV photon beams. Dose-volume histograms were analyzed to assess plan quality. Delivery parameters were reported to appraise technical features of RapidArc, and pretreatment quality assurance measurements were carried out to report on quality of delivery. Results: Average size of AVM nidus was 26.2 cm{sup 3}, and RapidArc plans provided complete target coverage with minimal overdosage (V{sub 100%} = 100% and V{sub 110%} < 1%) and excellent homogeneity (<6%). Organs at risk were highly spared. The D{sub 1%} to chiasm, eyes, lenses, optic nerves, and brainstem (mean {+-} SD) was 6.4 {+-} 8.3, 1.9 {+-} 3.8, 2.3 {+-} 2.2, 0.7 {+-} 0.9, 4.4 {+-} 7.2, 12.2 {+-} 9.6 Gy, respectively. Conformity index (CI{sub 95%}) was 2.2 {+-} 0.1. The number of monitor units per gray was 277 {+-} 45, total beam-on time was 2.5 {+-} 0.3 min. Planning vs. delivery {gamma} pass rate was 98.3% {+-} 0.9%. None of the patients developed acute toxicity. With a median follow-up of 9 months, 3 patients presented with deterioration of symptoms and were found to have postradiation changes but responded symptomatically to steroids. These patients continue to do well on follow-up. One patient developed headache and seizures, which was attributed to intracranial bleed, confirmed on imaging. Conclusion: Hypofractionated stereotactic radiotherapy can be successfully delivered using the RapidArc form of volumetric arc technology for intracranial AVMs. The quality of delivery and calculated parameters are in agreement with each other and are in line with published reports for other sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Personalized Assessment of kV Cone Beam Computed Tomography Doses in Image-guided Radiotherapy of Pediatric Cancer Patients

Purpose: To develop a quantitative method for the estimation of kV cone beam computed tomography (kVCBCT) doses in pediatric patients undergoing image-guided radiotherapy. Methods and Materials: Forty-two children were retrospectively analyzed in subgroups of different scanned regions: one group in the head-and-neck and the other group in the pelvis. Critical structures in planning CT images were delineated on an Eclipse treatment planning system before being converted into CT phantoms for Monte Carlo simulations. A benchmarked EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions of kVCBCT scans with full-fan high-quality head or half-fan pelvis protocols predefined by the manufacturer. Based on planning CT images and structures exported in DICOM RT format, occipital-frontal circumferences (OFC) were calculated for head-and-neck patients using DICOMan software. Similarly, hip circumferences (HIP) were acquired for the pelvic group. Correlations between mean organ doses and age, weight, OFC, and HIP values were analyzed with SigmaPlot software suite, where regression performances were analyzed with relative dose differences (RDD) and coefficients of determination (R{sup 2}). Results: kVCBCT-contributed mean doses to all critical structures decreased monotonically with studied parameters, with a steeper decrease in the pelvis than in the head. Empirical functions have been developed for a dose estimation of the major organs at risk in the head and pelvis, respectively. If evaluated with physical parameters other than age, a mean RDD of up to 7.9% was observed for all the structures in our population of 42 patients. Conclusions: kVCBCT doses are highly correlated with patient size. According to this study, weight can be used as a primary index for dose assessment in both head and pelvis scans, while OFC and HIP may serve as secondary indices for dose estimation in corresponding regions. With the proposed empirical functions, it is possible to perform an individualized quantitative dose assessment of kVCBCT scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In-Situ Consolidation Automated Fiber Placement of Thermoplastic Composites for High-Rate Aircraft Manufacturing

The National Aeronautics and Space Administration (NASA) initiated the Hi-Rate Composites Aircraft Manufacturing (HiCAM) project in 2021 with the goal of significantly increasing composite structures manufacturing rate in the commercial aircraft industry. The technologies currently under investigation include resin infusion and automated fiber placement (AFP) of novel thermoset materials and thermoplastic composites. Thermoplastic composites offer attractive solutions to rapid manufacturing due to their ability to be formed and consolidated quickly. NASA is particularly focused on assessing composite structure manufacturing utilizing an in-situ consolidation AFP of thermoplastics (ICAT) process employing a recently developed laser heating system. Two semi-crystalline polyaryletherketone thermoplastic tape materials were characterized to ascertain the ICAT process parameters at AFP placement speeds approaching 423 mm/s. The required laser power settings were determined at Electroimpact, measuring material temperatures utilizing a forward looking infrared (FLIR) thermal imaging camera and thermocouples. The material temperature, tool temperature, and placement speed were varied for resulting consolidation quality assessment. The resulting temperature data were also utilized to calibrate thermal analysis models under development at NASA. The experimental temperature data confirmed analytical results. An overview of the HiCAM project as well as initial data from ICAT process characterizations are described.

thermoplastic composites↗

In-Situ Consolidation Automated Fiber Placement of Thermoplastic Composites for High-Rate Aircraft Manufacturing

The National Aeronautics and Space Administration (NASA) initiated the Hi-Rate Composites Aircraft Manufacturing (HiCAM) project in 2021 with the goal of significantly increasing composite structures manufacturing rate in the commercial aircraft industry. The technologies currently under investigation include resin infusion and automated fiber placement (AFP) of novel thermoset materials and thermoplastic composites. Thermoplastic composites offer attractive solutions to rapid manufacturing due to their ability to be formed and consolidated quickly. NASA is particularly focused on assessing composite structure manufacturing utilizing an in-situ consolidation AFP of thermoplastics (ICAT) process employing a recently developed laser heating system. Two semi-crystalline polyaryletherketone thermoplastic tape materials were characterized to ascertain the ICAT process parameters at AFP placement speeds approaching 423 mm/s. The required laser power settings were determined at Electroimpact, measuring material temperatures utilizing a forward looking infrared (FLIR) thermal imaging camera and thermocouples. The material temperature, tool temperature, and placement speed were varied for resulting consolidation quality assessment. The resulting temperature data were also utilized to calibrate thermal analysis models under development at NASA. The experimental temperature data confirmed analytical results. An overview of the HiCAM project as well as initial data from ICAT process characterizations are described.

laser heating↗

Thermographic In-Situ Process Monitoring of the Electron Beam Melting Technology used in Additive Manufacturing

Oak Ridge National Laboratory (ORNL) has been utilizing the ARCAM electron beam melting technology to additively manufacture complex geometric structures directly from powder. Although the technology has demonstrated the ability to decrease costs, decrease manufacturing lead-time and fabricate complex structures that are impossible to fabricate through conventional processing techniques, certification of the component quality can be challenging. Because the process involves the continuous deposition of successive layers of material, each layer can be examined without destructively testing the component. However, in-situ process monitoring is difficult due to metallization on inside surfaces caused by evaporation and condensation of metal from the melt pool. This work describes a solution to one of the challenges to continuously imaging inside of the chamber during the EBM process. Here, the utilization of a continuously moving Mylar film canister is described. Results will be presented related to in-situ process monitoring and how this technique results in improved mechanical properties and reliability of the process.

Additive manufacturing↗

CHARACTERIZATION OF SECONDARY PHASES AND OTHER DEFECTS IN CDZNTE

Semiconducting CdZnTe or 'CZT' crystals are very suitable for use as a room temperature-based gamma radiation spectrometer. During the last decade, modifications in growth methods for CZT have significantly improved the quality of the produced crystals however there are material features that can influence the performance of these materials as radiation detectors. For example, various structural heterogeneities within the CZT crystals, such as, pipes, voids, polycrystallinity, and secondary phases (SP) can have a negative impact on the detector performance. In this study, a CZT material was grown by the modified vertical Bridgman growth (MVB) method with zone leveled growth in the absence of excess Te in the melt. Numerous SP were imaged using transmission IR at a volume % of 0.002. Samples from this material were analyzed using various analytical techniques to evaluate its electrical properties, purity and detector performance as radiation spectrometers and to determine the morphology, dimension and elemental /structural composition of one of the SP in this material. This material was found to have a high resistivity and good radiation spectrometer performance. It had SPs that were rich in calcium (Ca), carbon (C) and oxygen (O) (possibly CaCO{sub 3}) or only C and O that were 5 {micro}m or less in diameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗