Search NASA⌕ Search

SEARCH · Search NASA

Results for “image sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

High Energy Micron Scale Pixel Hybrid Detector

The objective of this technology development project has been to fabricate and characterize a new X-ray area image sensor innovation designed for high efficiency detection and imaging of hard X-rays (>20 KeV) with micron scale pixel resolution. A key technology component consists of a monolithic hybrid X-ray detector built by layering an amorphous Selenium X-ray photoconductor film directly deposited on a small pitch (7.8μm) CMOS active pixel readout array. A specific goal of this work is to provide a new detector tool to researchers working with synchrotron light sources, to extend the depth of exploration into nanoscale structures, and do so cost effectively. Early generation X-ray imaging detector tools fail to provide adequate resolving power and efficiency at high energies and our innovation provides a solution. A majority of proposed phase I tasks were completed. Those tasks included, in collaboration with KA Imaging, successful fabrication of specified a-Se layers on a 1Mpixel CMOS readout array to create the direct hybrid X-ray imaging array, packaging of the imaging array, assembly of electronics into a shielded detector box, loading user interface software for camera control and image capture, and performing initial (no X-ray) detector evaluation at Farrier Microengineering facilities. After initial tests, extensive testing using the X-ray beam line 1-BM source at Argonne National Laboratory Advanced Photon Source(ANL-APS) was performed. Imaging performance studies were conducted at multiple X-ray beam energies. Studies included X-ray response vs. X-ray energy, vs. applied detector field strength (HV), response linearity vs. integration time, MTF vs. beam energy, image lag measurements, and micron scale resolution pattern target imaging. This high energy micron scale X-ray detection technology is a first of a kind to be evaluated at the ANL-APS and is supported by Dr. Antonino Miceli, head of the detector physics group. Accomplishments include the first successful demonstration of a 1Mpix amorphous Selenium on CMOS readout direct hybrid X-ray imaging detector at a DOE sponsored National Laboratory. Modeled performance predictions were confirmed, proving micron scale resolution as well as an order of magnitude increase in conversion efficiency over conventional scintillator detector performance. A discovery of evidence of propagation-based phase contrast edge enhancement was unplanned and will be exploited in future experiments. This phase 1 technology demonstration verifies the efficacy of proposed high energy micron scale pixel X-ray hybrid a-Se imaging array products. The new detector products will cost effectively replace early generation detector technologies that currently fail to address increasing demand for tools to study nano structures and physical processes at high X-ray energies above 20keV. For example, current systems for transmission X-ray microscopy have low efficiency and available large pixel (~55µm) direct detectors do not offer sufficient resolution for Bragg fringe imaging at high energies. This detector innovation will solve these inadequacies. The new detector technology will compete in a $50M scientific X-ray detector market, growing at 6%, and will benefit Microtomography(µCT), X-ray diffractometry (XRD), Coherent Diffraction Imaging (CDI) applications. One application specified by Dr. Miceli at ANL is the 3D reconstruction of compact crystals at high energies requires small pixel high efficiency X-ray detectors. Farrier Microengineering, working with colleagues at KA Imaging and the University of Waterloo, successfully achieved the critical objectives of the Phase I proposal. We have proven the technical feasibility of this innovation by building and successfully testing a 1Mpixel a-Se/CMOS hybrid direct X-ray imaging array. Our commercialization roadmap of detector products will be implemented during a phase II project. We will demonstrate a migration of the technology to larger detector array sizes, improved temporal performance with detector layer engineering, and improved environmental and operational stability. Manufacturability and cost effectiveness are key objectives and product designs will leverage current state of the art CMOS wafer fabrication quality and volume manufacturing economics.

36 MATERIALS SCIENCE↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

NWB Sensors Infrared Cloud Imager Data Products from SGP

NWB Sensors is a company which has developed a commercially available Infrared Cloud Imager (ICI). For more information, consult the company's webpage, https://www.nwbsensors.com/infrared-cloud-imager. To validate the radiometric accuracy of the ICI, NWB Sensors deployed it to the ARM SGP User Facility in 2023. The primary motivation of this deployment was to perform an intercomparison between the ICI and the Atmospheric Emitted Radiance Interferometer (AERI). The AERI spectral radiance data product can be integrated across the response function of the ICI and directly compared to the zenith radiance observed by the ICI. In addition, the ICI uses proprietary models of the downwelling clear-sky radiance in its cloud processing algorithms. They are based on surface meteorology and precipitable water vapor (PWV). These models were validated by comparing their predicted radiances to those derived from radiative transfer models of the ARM radiosondes. Finally, PWV observations derived from the ICI's onboard GNSS-based PWV retrieval system were compared against those from the microwave radiometer. This dataset contains the ICI radiance and cloud data products.

Atmosphere↗

Event-to-Video Conversion for Overhead Object Detection

Collecting overhead imagery using an event camera is desirable due to the energy efficiency of the image sensor compared to standard cameras. However, event cameras complicate downstream image processing, especially for complex tasks such as object detection. In this paper, we investigate the viability of event streams for overhead object detection. We demonstrate that across a number of standard modeling approaches, there is a significant gap in performance between dense event representations and corresponding RGB frames. We establish that this gap is, in part, due to a lack of overlap between the event representations and the pre-training data that the object detectors were initially trained on through a number of experiments. Then, apply an off-the-shelf event-to-video conversion tool that converts event streams into gray-scale video to close this gap. We demonstrate that this approach results in a large performance increase, outperforming even event-specific object detection techniques on our overhead target task. These results suggest that better aligning event representations with existing large pre-trained models may result in greater short-term performance gains compared to end-to-end event-specific architectural improvements.

machine learning (ML), computer vision, Neuromorph↗

Super-resolution for scanning light stimulation systems

Super-resolution (SR) is a technique used in digital image processing to overcome the resolution limitation of imaging systems. In this process, a single high resolution image is reconstructed from multiple low resolution images. SR is commonly used for CCD and CMOS (Complementary Metal-Oxide-Semiconductor) sensor images, as well as for medical applications, e.g., magnetic resonance imaging. Here, we demonstrate that super-resolution can be applied with scanning light stimulation (LS) systems, which are common to obtain space-resolved electro-optical parameters of a sample. For our purposes, the Projection Onto Convex Sets (POCS) was chosen and modified to suit the needs of LS systems. To demonstrate the SR adaption, an Optical Beam Induced Current (OBIC) LS system was used. The POCS algorithm was optimized by means of OBIC short circuit current measurements on a multicrystalline solar cell, resulting in a mean square error reduction of up to 61% and improved image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A disposable x-ray camera based on mass produced complementary metal-oxide-semiconductor sensors and single-board computers

We have integrated mass-produced commercial complementary metal-oxide-semiconductor (CMOS) image sensors and off-the-shelf single-board computers into an x-ray camera platform optimized for acquisition of x-ray spectra and radiographs at energies of 2–6 keV. The CMOS sensor and single-board computer are complemented by custom mounting and interface hardware that can be easily acquired from rapid prototyping services. For single-pixel detection events, i.e., events where the deposited energy from one photon is substantially localized in a single pixel, we establish ∼20% quantum efficiency at 2.6 keV with ∼190 eV resolution and a 100 kHz maximum detection rate. The detector platform’s useful intrinsic energy resolution, 5-μm pixel size, ease of use, and obvious potential for parallelization make it a promising candidate for many applications at synchrotron facilities, in laser-heating plasma physics studies, and in laboratory-based x-ray spectrometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Performance of an Image Processing Occupancy Sensor

The design and performance of a novel image-processing occupancy sensor (IPOS) based on production-grade embedded hardware are described. The IPOS overcomes several issues related to traditional passive infrared (PIR) and ultrasonic-based motion sensors. It also provides a rich set of feedback signals that more sophisticated applications can use for occupant-optimized lighting, daylighting,temperature,and ventilation control, as well as with building security systems. The IPOS was tested as part of an integrated system consisting of a building energy management system (EMS) alongside a pair of PIR sensors produced by different manufacturers. IPOS output was fed to the EMS via the building automation and controls network (BACnet) and logged alongside the PIR outputs in an officeenvironment over several days. Tests suggest the IPOS device identifies occupancy events better than two commercial PIR sensors (94.1% accuracy compared to 73.1% on average). Also, IPOS could correctly identify stationary occupants whereas the PIR sensors could not.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methods for estimating photosynthetic characteristics in plant canopies and systems and apparatus related thereto

Methods of determining and characterizing photosynthesis in plant parts of one or more plants includes capturing a plurality of images of the plant parts of the one or more plants with a sensor are provided. Fluorescence of the plant parts of the one or more plants can be measured by storing a sensor image of observed fluorescence. Light absorbed by the plant parts of the one or more plants can be estimated by observing red and/or infrared reflectance of the plant parts. A characteristic of photosynthesis such as linear electron flow in plant parts of the one or more plants can be derived using the measured fluorescence of the plant parts, the reflectance and the light absorbed by the plant parts, and/or the three-dimensional model comprising the plant parts of the one or more plants. Related apparatus and systems are also provided.

54 ENVIRONMENTAL SCIENCES↗

Super resolution for magneto-optical microscopy

Sub-diffraction limited magneto-optical microscopy, such as Kerr or Faraday effect microscopy, provide many advantages to fields of science and technology for measuring, or imaging, the magnetization structures and magnetization domains of materials. Disclosed is a method and system for performing sub-diffraction limited magneto-optic microscopy. The method includes positioning a microlens or microlens layer relative to a surface of a sample to image the surface of the sample, forming a photonic nanojet to probe the surface of the sample, and receiving light reflected by the surface of the sample or transmitted through the sample at an imaging sensor. The methods and associated systems and devices enable sub-diffraction limited imaging of magnetic domains at resolutions 2 to 8 times the classical diffraction limit.

te Velthuis, Suzanne Gabriëlle Everdine↗

Ultrafast image-based dynamic light scattering for nanoparticle sizing

An ultrafast sizing method for nanoparticles is proposed, called as UIDLS (Ultrafast Image-based Dynamic Light Scattering). This method makes use of the intensity fluctuation of scattered light from nanoparticles in Brownian motion, which is similar to the conventional DLS method. The difference in the experimental system is that the scattered light by nanoparticles is received by an image sensor instead of a photomultiplier tube. A novel data processing algorithm is proposed to directly get correlation coefficient between two images at a certain time interval (from microseconds to milliseconds) by employing a two-dimensional image correlation algorithm. This coefficient has been proved to be a monotonic function of the particle diameter. Samples of standard latex particles (79/100/352/482/948 nm) were measured for validation of the proposed method. The measurement accuracy of higher than 90% was found with standard deviations less than 3%. A sample of nanosilver particle with nominal size of 20 ± 2 nm and a sample of polymethyl methacrylate emulsion with unknown size were also tested using UIDLS method. The measured results were 23.2 ± 3.0 nm and 246.1 ± 6.3 nm, respectively, which is substantially consistent with the transmission electron microscope results. Since the time for acquisition of two successive images has been reduced to less than 1 ms and the data processing time in about 10 ms, the total measuring time can be dramatically reduced from hundreds seconds to tens of milliseconds, which provides the potential for real-time and in situ nanoparticle sizing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Artificial illumination identification from an unmanned aerial vehicle

Artificial illumination identification within images is a useful tool for many applications. Performing such identification allows for an estimation of the illumination source spectrum, which in turn can be used for additional applications ranging from spectral detection and exploitation to statistics about nighttime light usage. Illumination identification has been performed in laboratory settings but not from an unmanned aerial vehicle (UAV) platform. Here, we test the feasibility of using a UAV and commercial off-the-shelf multispectral imaging sensor to perform such artificial illumination identification through linear discriminant analysis using nighttime UAV images. The results are very promising, showing source classification accuracies of 83.3%, 92.3%, 100%, and 100% for the incandescent, light-emitting diode, high pressure sodium, and metal halide illumination sources, respectively. We show that the information gained from the source identification can be further used to inform additional analysis, such as spectral identification. The high resolution of UAV imaging techniques combined with the knowledge of the illumination source can lead to better exploitation of such nighttime data for many applications.

42 ENGINEERING↗

Volumetric calibration of a plenoptic camera

Here, the volumetric calibration of a plenoptic camera is explored to correct for inaccuracies due to real-world lens distortions and thin-lens assumptions in current processing methods. Two methods of volumetric calibration based on a polynomial mapping function that does not require knowledge of specific lens parameters are presented and compared to a calibration based on thin-lens assumptions. The first method, volumetric dewarping, is executed by creation of a volumetric representation of a scene using the thin-lens assumptions, which is then corrected in post-processing using a polynomial mapping function. The second method, direct light-field calibration, uses the polynomial mapping in creation of the initial volumetric representation to relate locations in object space directly to image sensor locations. The accuracy and feasibility of these methods is examined experimentally by capturing images of a known dot card at a variety of depths. Results suggest that use of a 3D polynomial mapping function provides a significant increase in reconstruction accuracy and that the achievable accuracy is similar using either polynomial-mapping-based method. Additionally, direct light-field calibration provides significant computational benefits by eliminating some intermediate processing steps found in other methods. Finally, the flexibility of this method is shown for a nonplanar calibration.

47 OTHER INSTRUMENTATION↗

Mutual capacitance of liquid conductors in deformable tactile sensing arrays

Advances in highly deformable electronics are needed in order to enable emerging categories of soft computing devices ranging from wearable electronics, to medical devices, and soft robotic components. The combination of highly elastic substrates with intrinsically stretchable conductors holds the promise of enabling electronic sensors that can conform to curved objects, reconfigurable displays, or soft biological tissues, including the skin. Here, we contribute sensing principles for tactile (mechanical image) sensors based on very low modulus polymer substrates with embedded liquid metal microfluidic arrays. The sensors are fabricated using a single-step casting method that utilizes fine nylon filaments to produce arrays of cylindrical channels on two layers. The liquid metal (gallium indium alloy) conductors that fill these channels readily adopt the shape of the embedding membrane, yielding levels of deformability greater than 400%, due to the use of soft polymer substrates. We modeled the sensor performance using electrostatic theory and continuum mechanics, yielding excellent agreement with experiments. Using a matrix-addressed capacitance measurement technique, we are able to resolve strain distributions with millimeter resolution over areas of several square centimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fringing in MonoCam Y4 filter images

Here, we study the fringing patterns observed in MonoCam, a camera with a single Large Synoptic Survey Telescope (LSST) CCD sensor. Images were taken at the U.S. Naval Observatory in Flagstaff, Arizona (NOFS) employing its 1.3 m telescope and an LSST y4 filter. Fringing occurs due to the reflection of infrared light (700 nm or larger) from the bottom surface of the CCD which constructively or destructively interferes with the incident light to produce a net "fringe" pattern which is superimposed on all images taken. Emission lines from the atmosphere, dominated by hydroxyl (OH) spectra, can change in their relative intensities as the night goes on, producing different fringe patterns in the images taken. We found through several methods that the general shape of the fringe patterns remained constant, though with slight changes in the amplitude and phase of the fringes. Lastly, we also found that a superposition of fringes from two monochromatic lines taken in the lab offered a reasonable description of the sky data.

79 ASTRONOMY AND ASTROPHYSICS↗

Active multispectral imaging system for photodiagnosis and personalized phototherapies

The proposed system has been designed to identify dermatopathologies or to apply personalized phototherapy treatments. The system emits electromagnetic waves in different spectral bands in the range of visible and near infrared to irradiate the target (skin or any other object) to be spectrally characterized. Then, an imaging sensor measures the target response to the stimulus at each spectral band and, after processing, the system displays in real time two images. In one of them the value of each pixel corresponds to the more reflected wavenumber whereas in the other image the pixel value represents the energy absorbed at each band. The diagnosis capability of this system lies in its multispectral design, and the phototherapy treatments are adapted to the patient and his lesion by measuring his absorption capability. This “in situ” absorption measurement allows us to determine the more appropriate duration of the treatment according to the wavelength and recommended dose. The main advantages of this system are its low cost, it does not have moving parts or complex mechanisms, it works in real time, and it is easy to handle. For these reasons its widespread use in dermatologist consultation would facilitate the work of the dermatologist and would improve the efficiency of diagnosis and treatment. In fact the prototype has already been successfully applied to pathologies such as carcinomas, melanomas, keratosis, and nevi.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LumaCam: a novel class of position-sensitive event mode particle detectors using scintillator screens

A new type of position-sensitive detectors is gaining attention in the neutron community. They are scintillator based detectors that detect the scintillation light on an individual photon basis via an image intensifier and a fast image sensor. Their readout operates in event mode i.e. it produces information about individual neutron interactions, reconstructed from the sensor data, thus enabling to achieve superior spatial and temporal resolutions compared to regular detectors. Although the development of current detectors is focused on neutrons, the concept is also applicable to the detection of other particles such as high-energy photons. This document provides a description on how these detectors are built, how they operate, and what their characteristics are. An example of a detector implementation based on a Timepix3 chip is described to illustrate the detector concept. This includes a detailed description of the algorithm that reconstructs the neutron interactions from the sensor data, one of the core components that sets it apart from established scintillator-based imaging detectors. Energy-resolved epithermal neutron radiography was performed at the ISIS EMMA beamline with this detector, illustrating some of the fundamental differences in the data that can be produced with the new type of detector compared to more established types of scintillator based neutron detectors. The term LumaCam is proposed to refer to this new class of position-sensitive event-mode detectors.

47 OTHER INSTRUMENTATION↗

Combined Optical and Radio–Frequency Perspectives on the Time Evolution of Lightning Measured by the FORTE Satellite

We use a cluster feature data set for the Fast On-orbit Recording of Transient Events (FORTE) satellite that combines detections from its pixelated Lightning Locating System (LLS), photodiode detector (PDD) and Radio-Frequency (RF) instrumentation to generate statistics describing the frequency and timing of lightning events detected by each instrument during lightning flashes. Coincident observations from the same vantage point allow us to directly compare flash details that can be resolved by the wide Field of View (FOV) instruments relative to the pixelated LLS—whose design is based on NASA's Lightning Imaging Sensor. We find that both the PDD and RF system typically generate more detections than the lightning imager (mean: 1.5 PDD events per LLS group, 2 RF events per LLS group) from pulses that are either not sufficiently bright in the optical band (in the case of RF) or that lack the optical energy density (in the case of the PDD) required to trigger one of the pixels on the LLS imaging array. This includes additional activity before the first LLS group or after the final LLS group. These FORTE results demonstrate that certain lightning processes would be better resolved by wide-FOV optical and RF instruments than lightning imagers. Current/future space-based missions that use/plan to use similar instruments will improve our understanding of flash evolution by resolving details missed by lightning imagers.

47 OTHER INSTRUMENTATION↗