Search NASA⌕ Search

SEARCH · Search NASA

Results for “image velocimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Doppler Global Velocimetry Measurements for Supersonic Flow Fields

The application of Doppler Global Velocimetry (DGV) to high-speed flows has its origins in the original development of the technology by Komine et al (1991). Komine used a small shop-air driven nozzle to generate a 200 m/s flow. This flow velocity was chosen since it produced a fairly large Doppler shift in the scattered light, resulting in a significant transmission loss as the light passed through the Iodine vapor. This proof-of-concept investigation showed that the technology was capable of measuring flow velocity within a measurement plane defined by a single-frequency laser light sheet. The effort also proved that velocity measurements could be made without resolving individual seed particles as required by other techniques such as Fringe- Type Laser Velocimetry and Particle Image Velocimetry. The promise of making planar velocity measurements with the possibility of using 0.1-micron condensation particles for seeding, Dibble et al (1989), resulted in the investigation of supersonic jet flow fields, Elliott et al (1993) and Smith and Northam (1995) - Mach 2.0 and 1.9 respectively. Meyers (1993) conducted a wind tunnel investigation above an inclined flat plate at Mach 2.5 and above a delta wing at Mach 2.8 and 4.6. Although these measurements were crude from an accuracy viewpoint, they did prove that the technology could be used to study supersonic flows using condensation as the scattering medium. Since then several research groups have studied the technology and developed solutions and methodologies to overcome most of the measurement accuracy limitations:

Meyers, James F.↗

Laser-Induced Thermal Acoustics Theory and Expected Experimental Errors when Applied to a Scramjet Isolator Model

A scramjet isolator model test apparatus is being assembled in the Isolator Dynamics Research Lab (IDRL) at the NASA Langley Research Center in Hampton, Virginia. The test apparatus is designed to support multiple measurement techniques for investigating the flow field in a scramjet isolator model. The test section is 1-inch high by 2-inch wide by 24-inch long and simulates a scramjet isolator with an aspect ratio of two. Unheated, dry air at a constant stagnation pressure and temperature is delivered to the isolator test section through a Mach 2.5 planar nozzle. The isolator test section is mechanically back-pressured to contain the resulting shock train within the 24-inch isolator length and supports temperature, static pressure, and high frequency pressure measurements at the wall. Additionally, nonintrusive methods including laser-induced thermal acoustics (LITA), spontaneous Raman scattering, particle image velocimetry, and schlieren imaging are being incorporated to measure off-wall fluid dynamic, thermodynamic, and transport properties of the flow field. Interchangeable glass and metallic sidewalls and optical access appendages permit making multiple measurements simultaneously. The measurements will be used to calibrate computational fluid dynamics turbulence models and characterize the back-pressured flow of a scramjet isolator. This paper describes the test apparatus, including the optical access appendages; the physics of the LITA method; and estimates of LITA measurement uncertainty for measurements of the speed of sound and temperature.

Middleton, Troy F.↗

CFD Comparisons with Updated NASA Juncture Flow Data

The purpose of the NASA Juncture Flow experiment is to acquire high-quality flowfield details deep in the corner of a wing-body junction specifically for the purpose of CFD validation. A second phase of testing was recently completed, which includes both laser doppler velocimetry and particle image velocimetry measurements. This paper describes the recent experiment and its results. It also makes detailed comparisons between the experimental data and a new version of a widely-used CFD turbulence model for Reynolds-averaged Navier-Stokes, which was recently developed to improve separated corner flow predictions. The CFD results generally produce very good qualitative agreement with the experiment, although they are less accurate inside of the separation region, as expected.

Experimental Data↗

Particle Seeding Method for Small-Scale, High-Pressure Nozzles

NASA tests new launch and reentry vehicle configurations in wind tunnels, where flow visualizations and quantitative flowfield measurements are often desired. Some of these vehicles have rocket motors for propulsion, retro-propulsion, or reaction control. High-pressure air is used to supply these rocket motor plumes. However, it is difficult to make off-body measurements in these regions, for several reasons. First, the plumes themselves lack seeding particles for flow diagnostics, and at the low pressures after expansion, Rayleigh scattering or other molecular techniques yield insufficient signal for flow velocity measurements. Second, the plumes displace particle-seeded tunnel air, preventing measurements in the vicinity of the plume. Third, the plumes force shock waves ahead of the vehicle, which melts the ice crystal fog commonly used for visualization and measurement techniques in certain facilities. In the current work, a novel method for seeding the flow in these small-scale, high-pressure nozzles has been devised and initially demonstrated, potentially enabling quantitative and qualitative measurements with particle-based instruments such as Doppler global velocimetry or particle image velocimetry. The method involves a Venturi contraction to draw the seed liquid out of a reservoir and into the nozzle channel, wherein shearing forces atomize the seed into particles. The concept was tested with a laser sheet visualization, which demonstrated that the flow rate of liquid spray was controllable; a valve could be adjusted to drop the flow rate by up to 65%. This relatively inexpensive and simple technique may prove useful in wind tunnel experiments involving particle-based laser diagnostics and small, high-pressure nozzles.

Aditya S. Acharya↗

Applications of Digital Image Processing 11

A new technique, digital image velocimetry, is proposed for the measurement of instantaneous velocity fields of time dependent flows. A time sequence of single-exposure images of seed particles are captured with a high-speed camera, and a finite number of the single-exposure images are sampled within a prescribed period in time. The sampled images are then digitized on an image processor, enhanced, and superimposed to construct an image which is equivalent to a multiple exposure image used in both laser speckle velocimetry and particle image velocimetry. The superimposed image and a single-exposure Image are digitally Fourier transformed for extraction of information on the velocity field. A great enhancement of the dynamic range of the velocity measurement is accomplished through the new technique by manipulating the Fourier transform of both the single-exposure image and the superimposed image. Also the direction of the velocity vector is unequivocally determined. With the use of a high-speed video camera, the whole process from image acquisition to velocity determination can be carried out electronically; thus this technique can be developed into a real-time capability.

Cho, Y. -C.↗

Fuzzy Logic Particle Tracking

A new all-electronic Particle Image Velocimetry technique that can efficiently map high speed gas flows has been developed in-house at the NASA Lewis Research Center. Particle Image Velocimetry is an optical technique for measuring the instantaneous two component velocity field across a planar region of a seeded flow field. A pulsed laser light sheet is used to illuminate the seed particles entrained in the flow field at two instances in time. One or more charged coupled device (CCD) cameras can be used to record the instantaneous positions of particles. Using the time between light sheet pulses and determining either the individual particle displacements or the average displacement of particles over a small subregion of the recorded image enables the calculation of the fluid velocity. Fuzzy logic minimizes the required operator intervention in identifying particles and computing velocity. Using two cameras that have the same view of the illumination plane yields two single exposure image frames. Two competing techniques that yield unambiguous velocity vector direction information have been widely used for reducing the single-exposure, multiple image frame data: (1) cross-correlation and (2) particle tracking. Correlation techniques yield averaged velocity estimates over subregions of the flow, whereas particle tracking techniques give individual particle velocity estimates. For the correlation technique, the correlation peak corresponding to the average displacement of particles across the subregion must be identified. Noise on the images and particle dropout result in misidentification of the true correlation peak. The subsequent velocity vector maps contain spurious vectors where the displacement peaks have been improperly identified. Typically these spurious vectors are replaced by a weighted average of the neighboring vectors, thereby decreasing the independence of the measurements. In this work, fuzzy logic techniques are used to determine the true correlation displacement peak even when it is not the maximum peak, hence maximizing the information recovery from the correlation operation, maintaining the number of independent measurements, and minimizing the number of spurious velocity vectors. Correlation peaks are correctly identified in both high and low seed density cases. The correlation velocity vector map can then be used as a guide for the particle-tracking operation. Again fuzzy logic techniques are used, this time to identify the correct particle image pairings between exposures to determine particle displacements, and thus the velocity. Combining these two techniques makes use of the higher spatial resolution available from the particle tracking. Particle tracking alone may not be possible in the high seed density images typically required for achieving good results from the correlation technique. This two-staged velocimetric technique can measure particle velocities with high spatial resolution over a broad range of seeding densities.

Source record↗

Evaluation of intracoronary hemodynamics identifies perturbations in vorticity

Coronary artery disease (CAD) is highly prevalent and associated with adverse events. Challenges have emerged in the treatment of intermediate coronary artery stenoses. These lesions are often interrogated with fractional flow reserve (FFR) testing to determine if a stenosis is likely to be causative for ischemia in a cardiac territory. This invasive test requires insertion of a pressure wire into a coronary vessel. Recently computational fluid dynamics (CFD) has been used to noninvasively assess fractional flow reserve in vessels reconstructed from medical imaging data. However, many of these simulations are unable to provide additional information about intravascular hemodynamics, including velocity, endothelial shear stress (ESS), and vorticity. We hypothesized that vorticity, which has demonstrated utility in the assessment of ventricular and aortic diseases, would also be an important hemodynamic factor in CAD. Three-dimensional (3D), patient-specific coronary artery geometries that included all vessels >1 mm in diameter were created from angiography data obtained from 10 patients who underwent diagnostic angiography and FFR testing (n = 9). A massively parallel CFD solver (HARVEY) was used to calculate coronary hemodynamic parameters including pressure, velocity, ESS, and vorticity. These simulations were validated by comparing velocity flow fields from simulation to both velocities derived from in vitro particle image velocimetry and to invasively acquired pressure wire-based data from clinical testing. There was strong agreement between findings from CFD simulations and particle image velocimetry experimental testing (p < 0.01). CFD-FFR was also highly correlated with invasively measured FFR (ρ = 0.77, p = 0.01) with an average error of 5.9 ± 0.1%. CFD-FFR also had a strong inverse correlation with the vorticity (ρ = -0.86, p = 0.001). Simulations to determine the effect of the coronary stenosis on intravascular hemodynamics demonstrated significant differences in velocity and vorticity (both p < 0.05). Further evaluation of an angiographically normal appearing non-FFR coronary vessel in patients with CAD also demonstrated differences in vorticity when compared with FFR vessels (p < 0.05). The use of highly accurate 3D CFD-derived intravascular hemodynamics provides additional information beyond pressure measurements that can be used to calculate FFR. Vorticity is one parameter that is modified by a coronary stenosis and appears to be abnormal in angiographically normal vessels in patients with CAD, highlighting a possible use-case in preventative screening for early coronary disease.

59 BASIC BIOLOGICAL SCIENCES↗

Flow Field Measurement of Mixing Driven by Buoyancy

Mixing driven by buoyancy-induced flows inside a cavity consists of stretching and folding of an interface. Measurement of the flow field using particle imaging velocimetry shows that during stretching the flow field has a single elliptic point, thus dominated by a single vortex. However, global bifurcation that results in folding introduces a hyperbolic point whereby the flow field degenerates to multiple vortex interactions. The short-lived coherent structure observed during mixing which results in the Rayleigh- Taylor morphology is attributed to vortex interactions. The mixing characteristics of non-homogeneous fluids driven by buoyancy are important towards understanding transport phenomenon in a microgravity environment. Mixing consists of stretching and folding of an interface due to a flow field whose intensity depends on the body force. For miscible liquids, the characteristic of the flow field determines whether mass transport is governed by diffusion or bulk stirring which induces mixing. For technologically important processes, transport of mass is governed by the coupling of the body force to scalar gradients such as concentration and or temperature' 2 3 . In order to lend insight into these classes of problems we consider a model experimental system to study mixing driven by buoyancy-induced flows. The characteristics of mixing is addressed from detail measurements of the flow field using particle imaging velocimetry (PIV), and its corresponding interface dynamics using image processing techniques.

Batur, C.↗

Development of Hydroxyl Tagging Velocimetry for Low Velocity Flows

Hydroxyl tagging velocimetry (HTV) is a molecular tagging technique that relies on the photo-dissociation of water vapor into OH radicals and their subsequent tracking using laser induced fluorescence. Velocities are then obtained from time-of-flight calculations. At ambient temperature in air, the OH species lifetime is relatively short (<50 μs), making it suited for high speed flows. Lifetime and radicals formation increases with temperature, which allows HTV to also probe low-velocity, high-temperature flows or reacting flows such as flames. The present work aims at extending the domain of applicability of HTV, particularly towards low-speed (<10 m/s) and moderate (<500 K) temperature flows. Results are compared to particle image velocimetry (PIV) measurements recorded in identical conditions. Single shot and averaged velocity profiles are obtained in an air jet at room temperature. By modestly raising the temperature (100-200 degC) the OH production increases, resulting in an improvement of the signal-to-noise ratio (SNR). Use of nitrogen - a non-reactive gas with minimal collisional quenching - extends the OH species lifetime (to over 500 μs), which allows probing of slower flows or, alternately, increases the measurement precision at the expense of spatial resolution. Instantaneous velocity profiles are resolved in a 100degC nitrogen jet (maximum jet-center velocity of 6.5 m/s) with an uncertainty down to 0.10 m/s (1.5%) at 68% confidence level. MTV measurements are compared with particle image velocimetry and show agreement within 2%.

Andre, Matthieu A.↗

Scale-Dependent Bedform Migration and Deformation in the Physical and Spectral Domains

Multi-scale bathymetries observed in laboratory channels and natural rivers have posed several challenges to the description of bedform geometry and kinematics. To better quantify scale-dependent migration velocity, high resolution spatio-temporal bed evolution data are analyzed using three independent methods: (i) a bedform tracking method that identifies individual bedforms in longitudinal bed elevation profiles, (ii) a cross-correlation based, image matching technique in consecutive bathymetry scans similar to Particle Image Velocimetry, and (iii) two-dimensional frequency-wavenumber spectra marking a dispersion relation between bedform period and length, allowing estimation of Fourier-based, scale-dependent migration velocities. The comparative studies show that the spectral and bedform tracking methods present small differences in the migration velocity of medium-large bedforms. However, significant deviations occur in the small bedforms, mostly due to bedform sheltering or amplified exposure to the flow, which also contribute to their enhanced scale-dependent deformation. The analysis also shows that some form of scale separation is needed to extract the large and slowly migrating bedforms as they are masked by secondary features when several bedform orders coexist. Bathymetric Image Velocimetry reasonably estimates the averaged migration velocity and exhibits potential to study relations between spanwise bed surface velocity and local bedform kinematics.

58 GEOSCIENCES↗

Pseudo-viscous modeling of transport in dense granular flows for thermal energy storage applications

Dense, granular flows were examined to effectively capture and model bulk viscous properties in thin packed beds. A modified Couette cell with particle image velocimetry was used to experimentally determine pseudo-viscosity properties of four particulate media with varying morphologies: (1) iron oxide-coated SiO 2 particles, (2) CARBOBEAD CP30-60 particles, (3) CARBOBEAD CP40-100 particles, and (4) Al 2 O 3 beads. The pseudo-viscosity functions were fitted using a power law to correlate the measured shear stress as a function of measured shear rate. The pseudo-viscous functions were used as inputs to computation fluid dynamics models for a single-phase viscous fluid to predict granular flow profiles. Steady-state free surface velocity profiles at angular velocities <7 rad/s predicted by the model were in good agreement with the experimental particle image velocimetry measurements, resulting in Pearson correlation coefficients of 0.97 for iron-oxide coated SiO 2 particles and 0.95 for CP30-60 particles. As a result, this alternative approach to measuring pseudo-viscous properties under shearing and modeling bulk transport behavior of granular flow using computation fluid dynamics model offered significant reduction in computational load compared to discrete element methods.

14 SOLAR ENERGY↗

Noise Measurements of a Low-Noise Top-Mounted Propulsion Installation for a Supersonic Airliner

A model-scale exhaust system was tested to validate low-noise concepts and noise prediction methods. The tests involved far-field acoustics, translating phased array, and particle image velocimetry; this report covers the far-field acoustic measurements. Data were acquired for a series of nozzles with different chevron designs, both uninstalled and installed on a representative aircraft planform. The impact of the various chevron treatments on the far-field noise was documented, along with the impact of the pylon and planform. For the baseline nozzle, installation produced a 2EPNdB reduction, as assumed in system studies. Chevrons were used to shift noise sources upstream to maximize the installation benefits and to reduce unshielded sources downstream. These resulted in reductions of 4-5EPNdB relative to the uninstalled baseline nozzle. Detailed analysis of spectral directivities behind the integrated EPNL metric gave insight into how well these concepts actually work. When correlated with particle image velocimetry measurements and phased array measurements, reported in companion papers, the explanation of acoustic benefits from top-mounted propulsion is clear as is the path toward optimization of the concept.

Supersonics↗

Active Flow Control Using Sweeping Jet Actuators on a Semi-Span Wing Model

Wind tunnel experiments were performed using active flow control on an unswept semispan wing model with a 30% chord trailing edge flap to aid in the selection of actuators for a planned high Reynolds number experiment. Two sweeping jet actuator sizes were investigated to determine the influence of actuator size on the active flow control system efficiency. Sweeping jet actuators with orifice sizes of 1 mm x 2 mm and 2 mm x 4 mm were selected because of the differences in actuator jet sweep angle. The parameters that were varied include actuator momentum, freestream velocity, and trailing edge flap deflection angle. Steady and unsteady pressure data, Particle Image Velocimetry data, and force and moment data were acquired to assess the performance of the two actuators. In addition to the wind tunnel experiments, benchtop studies of the actuators were performed to characterize the jets produced by each actuator. Benchtop investigations of the smaller actuator reveal that the jet exiting the actuator has a reduced sweep angle compared to published data for larger versions of this type of actuator. The larger actuator produces an oscillating jet that attaches to the external di↵user walls at low supply pressures and produces the expected sweep angles. The AFC results using the smaller actuators show that while the actuators can control flow separation, the selected spacing of 3.3 cm may be too large due to the reduced sweep angle. In comparison, the spacing for the larger actuators, 6.6 cm, appears to be optimal for the Mach numbers investigated. Particle Image Velocimetry results are presented and show how the wall jets produced by the actuators cause the flow to attach to the flap surface.

Melton, LaTunia Pack↗

PIV Measurements of Supersonic Internally-Mixed Dual-Stream Jets

While externally mixed, or separate flow, nozzle systems are most common in high bypass-ratio aircraft, they are not as attractive for use in lower bypass-ratio systems and on aircraft that will fly supersonically. The noise of such propulsion systems is also dominated by jet noise, making the study and noise reduction of these exhaust systems very important, both for military aircraft and future civilian supersonic aircraft. This paper presents particle image velocimetry of internally mixed nozzle with different area ratios between core and bypass, and nozzles that are ideally expanded and convergent. Such configurations independently control the geometry of the internal mixing layer and of the external shock structure. These allow exploration of the impact of shocks on the turbulent mixing layers, the impact of bypass ratio on broadband shock noise and mixing noise, and the impact of temperature on the turbulent flow field. At the 2009 AIAA/CEAS Aeroacoustics Conference the authors presented data and analysis from a series of tests that looked at the acoustics of supersonic jets from internally mixed nozzles. In that paper the broadband shock and mixing noise components of the jet noise were independently manipulated by holding Mach number constant while varying bypass ratio and jet temperature. Significant portions of that analysis was predicated on assumptions regarding the flow fields of these jets, both shock structure and turbulence. In this paper we add to that analysis by presenting particle image velocimetry measurements of the flow fields of many of those jets. In addition, the turbulent velocity data documented here will be very useful for validation of computational flow codes that are being developed to design advanced nozzles for future aircraft.

Bridges, James E.↗

Vortex Rings Generated by a Shrouded Hartmann-Sprenger Tube

The pulsed flow emitted from a shrouded Hartmann-Sprenger tube was sampled with high-frequency pressure transducers and with laser particle imaging velocimetry, and found to consist of a train of vortices. Thrust and mass flow were also monitored using a thrust plate and orifice, respectively. The tube and shroud lengths were altered to give four different operating frequencies. From the data, the radius, velocity, and circulation of the vortex rings was obtained. Each frequency corresponded to a different length to diameter ratio of the pulse of air leaving the driver shroud. Two of the frequencies had length to diameter ratios below the formation number, and two above. The formation number is the value of length to diameter ratio below which the pulse converts to a vortex ring only, and above which the pulse becomes a vortex ring plus a trailing jet. A modified version of the slug model of vortex ring formation was used to compare the observations with calculated values. Because the flow exit area is an annulus, vorticity is shed at both the inner and outer edge of the jet. This results in a reduced circulation compared with the value calculated from slug theory accounting only for the outer edge. If the value of circulation obtained from laser particle imaging velocimetry is used in the slug model calculation of vortex ring velocity, the agreement is quite good. The vortex ring radius, which does not depend on the circulation, agrees well with predictions from the slug model.

DeLoof, Richard L.↗

Turbulence Measurements on a Flap-Edge Model

Turbulence measurements have been made on a flap-edge and leading-edge slat model using hot-wire anemometry, and, later, particle image velocimetry. The properties of hot-wire anemometry were studied using facilities at NASA Ames Research Center. Hot-film probes were used because of their durability, but cross-films were limited by non-linear end effects. As a warm-up exercise, hot-film probes were used to measure velocities in the farfield wake of a cylinder with an airfoil in the near-field wake. The airfoil reduced the drag coefficient of the system by 10%. A single-wire hot-film probe was used to measure velocity profiles over the top of a NACA 63(sub 2)-215 Mod. B wing with a Fowler flap and leading,-edge slat. Results showed the size of slat wake was dependent upon the slat deflection angle. Velocity increased through the slat gap with increased deflection. The acoustically modified slat decreased the chance of separation. Measurements were taken at the flap edge with a single hot-film. Trends in the data indicate velocity and turbulence levels increase at the flap edge. The acoustically modified flap modifies the mean flow near the flap edge. Correlations were made between the hot-film signal and the unsteady pressure transducers on the wing which were published in a NASA CDTM. The principles of Particle Image Velocimetry (PIV) were studied at Florida State University. Spectral PIV was used to measure the spectra of a subsonic jet. Measured frequencies were close to the predicted frequency of jet shedding. Spectral PIV will be used to measure the spectra of the slat flow in the second 7 x lO-ft. wind tunnel test. PIV has an advantage that it can measure velocity and spectra of the entire flowfield instantaneously. However, problems arise when trying, to store this massive amount of PIV data. Support for this research has continued through a NASA Graduate Student Program Fellowship which will end in June 1999. The thesis should be completed by this time.

Moriarty, Patrick↗

The role of photographic parameters in laser speckle or particle image displacement velocimetry

The parameters involved in obtaining the multiple exposure photographs in the laser speckle velocimetry method (to record the light scattering by the seeding particles) were optimized. The effects of the type, concentration, and dimensions of the tracer, the exposure conditions (time between exposures, exposure time, and number of exposures), and the sensitivity and resolution of the film on the quality of the final results were investigated, photographing an experimental flow behind an impulsively started circular cylinder. The velocity data were acquired by digital processing of Young's fringes, produced by point-by-point scanning of a photographic negative. Using the optimal photographing conditions, the errors involved in the estimation of the fringe angle and spacing were of the order of 1 percent for the spacing and +/1 deg for the fringe orientation. The resulting accuracy in the velocity was of the order of 2-3 percent of the maximum velocity in the field.

Lourenco, L.↗