Acquiring and Converting Energy-Discriminated X-ray Image Data.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Purpose: Artifacts arising from the 4D CT acquisition and post-processing methods add systematic uncertainty to the treatment planning process. We propose an alternate cine 4D CT acquisition and post-processing method to consistently reduce artifacts, and explore patient parameters indicative of image quality. Methods: In an IRB-approved protocol, 18 patients with primary thoracic malignancies received a standard cine 4D CT acquisition followed by an oversampling 4D CT that doubled the number of images acquired. A second cohort of 10 patients received the clinical 4D CT plus 3 oversampling scans for intra-fraction reproducibility. The clinical acquisitions were processed by the standard phase sorting method. The oversampling acquisitions were processed using Dijkstras algorithm to optimize an artifact metric over available image data. Image quality was evaluated with a one-way mixed ANOVA model using a correlation-based artifact metric calculated from the final 4D CT image sets. Spearman correlations and a linear mixed model tested the association between breathing parameters, patient characteristics, and image quality. Results: The oversampling 4D CT scans reduced artifact presence significantly by 27% and 28%, for the first cohort and second cohort respectively. From cohort 2, the inter-replicate deviation for the oversampling method was within approximately 13% of the cross scan average at the 0.05 significance level. Artifact presence for both clinical and oversampling methods was significantly correlated with breathing period (ρ=0.407, p-value<0.032 clinical, ρ=0.296, p-value<0.041 oversampling). Artifact presence in the oversampling method was significantly correlated with amount of data acquired, (ρ=-0.335, p-value<0.02) indicating decreased artifact presence with increased breathing cycles per scan location. Conclusion: The 4D CT oversampling acquisition with optimized sorting reduced artifact presence significantly and reproducibly compared to the phase-sorted clinical acquisition.
Purpose: In clinical pencil-beam-scanned (PBS) proton therapy, the advantage of the characteristic sharp dose fall-off after the Bragg Peak (BP) becomes a disadvantage if the BP positions of a plan’s constituent pencil beams are shifted, eg.due to anatomical changes. Thus, for fractionated PBS proton therapy, accurate knowledge of the water equivalent path length (WEPL) of the traversed anatomy is critical. In this work we investigate the feasibility of using 2D proton range maps (proton radiography, PR) with the active-scanning gantry at PSI. Methods: We simulated our approach using Monte Carlo methods (MC) to simulate proton beam interactions in patients using clinical imaging data. We selected six head and neck cases having significant anatomical changes detected in per-treatment CTs.PRs (two at 0°/90°) were generated from MC simulations of low-dose pencil beams at 230MeV. Each beam’s residual depth-dose was propagated through the patient geometry (from CT) and detected on exiting the patient anatomy in an ideal depth-resolved detector (eg. range telescope). Firstly, to validate the technique, proton radiographs were compared to the ground truth, which was the WEPL from ray-tracing in the patient CT at the pencil beam location. Secondly, WEPL difference maps (per-treatment – planning imaging timepoints) were then generated to locate the anatomical changes, both in the CT (ground truth) and in the PRs. Binomial classification was performed to evaluate the efficacy of the technique relative to CT. Results: Over the projections simulated over all six patients, 70%, 79% and 95% of the grid points agreed with the ground truth proton range to within ±0.5%, ±1%, and ±3% respectively. The sensitivity, specificity, precision and accuracy were high (mean±1σ, 83±8%, 87±13%, 95±10%, 83±7% respectively). Conclusion: We show that proton-based radiographic images can accurately monitor patient positioning and in vivo range verification, while providing equivalent WEPL information to a CT scan, with the advantage of a much lower imaging dose.
A system for generating and authenticating remote sensing imagery includes a remote sensing platform. The remote sensing platform includes an imaging sensor and a hardware logic device that is directly coupled to the imaging sensor. The hardware logic device receives image data from the imaging sensor and generates a cryptographic signature based upon the image data. The hardware logic device outputs a signed image that includes the image data and the cryptographic signature. A computing device operated by a downstream user receives the signed image and can determine whether the image data has been modified from its original content based upon the cryptographic signature.
A downhole multi-modality inspection system includes a first imaging device operable to generate first imaging data and a second imaging device operable to generate second imaging data. The first imaging device includes a first source operable to emit energy of a first modality, and a first detector operable to detect returning energy induced by the emitted energy of the first modality. The second imaging device includes a second source operable to emit energy of a second modality, and a second detector operable to detect returning energy induced by the emitted energy of the second modality. The system further includes a processor configured to receive the first imaging data and the second imaging data, and integrate the first imaging data with the second imaging data into an enhanced data stream. The processor correlates the first imaging data and the second imaging data to provide enhanced data for detecting potential wellbore anomalies.
irsi: Infrared Sky Imager visible data
An air-to-air background-oriented Schlieren system and method for measuring and rendering visible density changes in air that cause a refractive index change by an airborne vehicle. A sensor aircraft equipped with a high-speed visible spectrum camera travels at low airspeed on a predetermined route and on a level altitude over a background having consistent contrast and sunlight reflectivity. The target aircraft, traveling on the same predetermined route but at an altitude between the sensor aircraft and the ground (background) passes beneath the sensor aircraft. The camera on the sensor aircraft captures a series of images including a reference image immediately before the target aircraft enters the image frame followed by several data images as the target aircraft passes through the image frame. The data images are processed to calculate density gradients around the target aircraft. These density gradients include shockwaves, vortices, engine exhaust, and wakes. Air density gradients cause a refractive index change in the fluid and a slight distortion in the background pattern of the data image. Image processing that compares the data image to the reference image yields the difference caused by the density gradient.
Images were collected using first of their kind, non-destructive, high-resolution automated minirhizotrons (RhizoSystems, LLC) to assess the response of plant fine-root and fungal mycelium dynamics to elevated temperatures after 4-6 years of whole-ecosystem warming and exposure to elevated carbon dioxide concentrations (e[CO2]) in a peat bog where the SPRUCE (Spruce and Peatland Responses Under Changing Environments) experiment is located. We focused on two SPRUCE experimental plots: Plot 10 has elevated temperature (+9°C) and plot 19 is a control (+0°C). Both have elevated carbon dioxide (e[CO2]). Changes in root and fungal abundance with warming were estimated from a timeseries of landscape-level mosaiced images for each plot by measuring the proportional abundance of five belowground classes: fine roots of vascular plants, ectomycorrhizas, fungal hyphae, fungal rhizomorphs, and fungal sporocarps. To examine root and fungal phenology responses to warming, the length per individual root or fungal structure (except fungal hyphae that did not grow linearly but rather increased in areal coverage) were measured per image area of a set of timeseries patch-level mosaiced images for each plot. The experimental work was conducted in a Picea mariana [black spruce] – Sphagnum spp. bog forest in northern Minnesota, 40 km north of Grand Rapids, in the USDA Forest Service Marcell Experimental Forest (MEF). This ecosystem, which is located at the southern margin of the boreal forest, is considered especially vulnerable to climate change and anticipated to be near its tipping point. These data were used in analyses published in Defrenne et al (2021). This dataset contains 5 data files in comma-separate values (*.csv) format and a compressed folder (*.zip) containing 383 JPEG (*.jpg) images. Data files contain landscape-level assessment of belowground class abundance, patch-level growth phenology, and environmental variables (originally published in Hanson et al., 2016 and Hanson et al 2020). Images were collected with automated minirhizotrons and analyzed for phenology. Additional metadata are provided: 5 data dictionaries and a file-level metadata file in comma-separate values (.csv) format and a user guide in PDF (*.pdf) format.
The Ultrasonic Propagation Imaging (UPI) System is a unique, non-contact, laser-based ultrasonic excitation and measurement system developed for structural health monitoring applications. The UPI system imparts laser-induced ultrasonic excitations at user-defined locations on a structure of interest. The response of these excitations is then measured by piezoelectric transducers. By using appropriate data reconstruction techniques, a time-evolving image of the response can be generated. A representative measurement of a plate might contain 800x800 spatial data measurement locations and each measurement location might be sampled at 500 instances in time. The result is a total of 640,000 measurement locations and 320,000,000 unique measurements. This is clearly a very large set of data to collect, store in memory and process. The value of these ultrasonic response images for structural health monitoring applications makes tackling these challenges worthwhile. Recently compressed sensing has presented itself as a candidate solution for directly collecting relevant information from sparse, high-dimensional measurements. The main idea behind compressed sensing is that by directly collecting a relatively small number of coefficients it is possible to reconstruct the original measurement. The coefficients are obtained from linear combinations of (what would have been the original direct) measurements. Often compressed sensing research is simulated by generating compressed coefficients from conventionally collected measurements. The simulation approach is necessary because the direct collection of compressed coefficients often requires compressed sensing analog front-ends that are currently not commercially available. The ability of the UPI system to make measurements at user-defined locations presents a unique capability on which compressed measurement techniques may be directly applied. The application of compressed sensing techniques on this data holds the potential to reduce the number of required measurement locations, reduce the time to make measurements, reduce the memory required to store the measurements, and possibly reduce the computational burden to classify the measurements. This work considers the appropriate selection of the signal dictionary used for signal reconstruction, and performs an evaluation of compressed sensing technique's ability to reconstruct ultrasonic images using fewer measurements than would be needed using traditional Nyquist-limited data collection techniques.
A method includes placing an imaging device in contact with a sample, irradiating the sample via an illuminator such that radiation scatters off of the structure, and providing the scattered radiation to a detector to generate a digital video signal. A processor then performs various operations including subtracting a sum of a black state value and a user-defined black level clamping value from the digital video signal to create subtracted image data, substituting negative values in the subtracted image data with a reference value to create modified image data, and amplifying the modified image data by a user-defined gain to create contrast enhanced image data.
Image data from a CMOS sensor with 10 bit resolution is reformatted in real time to allow the data to stream through communications equipment that is designed to transport data with 8 bit resolution. The incoming image data has 10 bit resolution. The communication equipment can transport image data with 8 bit resolution. Image data with 10 bit resolution is transmitted in real-time, without a frame delay, through the communication equipment by reformatting the image data.
Harnessing big data, deep data, and smart data from state-of-the-art imaging might accelerate the design and realization of advanced functional materials. Here we discuss new opportunities in materials design enabled by the availability of big data in imaging and data analytics approaches, including their limitations, in material systems of practical interest. We specifically focus on how these tools might help realize new discoveries in a timely manner. Such methodologies are particularly appropriate to explore in light of continued improvements in atomistic imaging, modelling and data analytics methods.