Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Advancing 3D surface imaging: single-axis structured light illumination plenoptic camera with machine learning integration

Structured light illumination (SLI) is a configurable 3D surface imaging modality that can function largely independently of surface texture. At the same time, machine learning (ML) approaches are providing new ways to capture relevant information from SLI patterns, avoiding the need to develop advanced computer vision algorithms. By projecting an optical pattern onto a surface and measuring the apparent distortion of that pattern, one can determine surface topography from a single image. Common realizations of SLI 3D imaging use off-axis SLI to allow for parallax-based determination of depth; however, in constrained geometries, the ability to make single-axis measurements can be of major benefit. While plenoptic imaging (PI) cameras have long been developed for the purpose of single-axis 3D imaging, they are generally reliant on the surface texture of the measured object, thus making them unreliable in certain experimental conditions. Therefore, we present a single-axis 3D SLI plenoptic camera, which combines the single-axis benefits of PI technology while using coaxial SLI to maintain indifference to surface conditions. We also present a study of the camera capabilities paired with the development of several algorithms, including traditional feature tracking methods as well as ML methods, which are found to enhance resolution and range. We report depth sensitivity down to 0.2% $\frac{dz}{z_0}$. The single-axis SLI 3D plenoptic camera demonstrates potential applicability for in-situ topographical measurements under a wide range of conditions including, but not limited to, objects without trackable surface texture, high temperatures, and constrained geometry environments.

Imaging systems↗

Correlative multimodal chemical imaging via machine learning

Machine learning approach can combine mass spectral imaging (MSI) techniques, one with low spatial resolution but intact molecular spectra and the other with nanometer spatial resolution but fragmented molecular signatures, to predict molecular MSI spectra with submicron spatial resolution. The machine learning approach can perform transformations on the spectral image data of the two MSI techniques to reduce dimensionality, and using a correlation technique, find relationships between the transformed spectral image data. The determined relationships can be used to generate MSI spectra of desired resolution.

Ovchinnikova, Olga S.↗

Comparative Assessment of U-Net-Based Deep Learning Models for Segmenting Microfractures and Pore Spaces in Digital Rocks

Segmentation of high-resolution X-ray microcomputed tomography (µCT) images is crucial in digital rock physics (DRP), affecting the characterization and analysis of microscale phenomena in the porous media. The complexity of geological structures and nonideal scanning conditions pose significant challenges to conventional image segmentation approaches. Motivated by the recent increasing popularity of deep learning (DL) techniques in image processing, this work undertakes a comparative study of DL models, specifically U-Net and its variants, for segmenting multiple targets with distinguished features in digital rocks, including discrete fracture networks (DFNs), pore spaces, and solid rock. Particularly, DFNs have a smaller volumetric fraction over others, bringing in a substantial challenge of imbalanced segmentation. The primary focus is to evaluate the architecture and feature enhancement strategies of various DL models, including U-Net, attention U-Net, residual U-Net, U-Net++, and residual U-Net++. The models were designed as 2.5D, utilizing a central 2D image and its two adjacent upper and lower 2D images as input to provide a pseudo-3D context. In addition, because the ground truth of segmentation was unknown for real-world digital rocks, we created a benchmark data set following the inverse operations of segmentation. The data synthesis started from the label images (i.e., solid rock, pore spaces, and DFNs), followed by simulating partial volume blurring, adding random background noise, and introducing ring artifacts to mimic real raw X-ray µCT images. The data set, which included various rock types (i.e., sandstone and artificial data), scanning resolution, and magnitudes of noise and artifacts, was divided into training and testing data sets with a 90% and 10% ratio, respectively. Moreover, in addition to the conventional pixel-wise evaluation metrics, the physics-based metric of the lattice-Boltzmann method (LBM) simulated permeability provided more comprehensive assessments. The results demonstrated that the residual connections, nested architectures, and redesigned skip connections contribute to the model performance and give the residual U-Net++ the highest accuracy. The improvements were mainly on the boundaries and small targets, especially the DFNs, which dominate the interconnectivity and therefore affect the permeability greatly. This study also rigorously evaluated the efficiency and generalization of each model, demonstrating that the sophisticated architectures achieved excellent practicability and maintained robust performance on completely unseen data, ensuring their suitability for diverse and challenging DRP applications.

58 GEOSCIENCES↗

Neutron and x-ray computed tomography of a natural uranium tristructural isotropic (TRISO) fuel compact

A natural uranium-based, unirradiated tristructural isotropic (TRISO) fuel compact was nondestructively imaged using both X-ray (XCT) and neutron computed tomography (nCT). While XCT of compacts can provide information on fuel kernels, imaging artifacts preclude examination of the graphite matrix. In this work, nCT was used for the first time on a TRISO compact to examine the graphite matrix. A crack was clearly resolved within the graphite matrix, proving that nCT is a viable tool for nondestructive volumetric examination of the matrix material in TRISO fuel compacts. The XCT and nCT data were then fused together to create a more comprehensive dataset containing both matrix and fuel kernels.

36 - MATERIALS SCIENCE↗

Pore-scale visualization of natural hydrate-bearing sediments

Accurate modeling of gas hydrate reservoir productivity and geomechanical risks associated with subsurface dissociation of natural gas hydrates (NGH) requires the determination of model parameters through physical testing on natural hydrate-bearing sediments (HBS). This involves investigating the hydro-mechanical behavior of undisturbed hydrate samples from nature under in situ conditions using pressure core characterization and analysis, which provides a unique opportunity for research. By employing state-of-the-art micro computed tomography imagery on cryogenically preserved, hydrate-bearing sediment samples, we can determine hydrate saturation as well as permeability with and without the presence of hydrates in the sediment. Furthermore, utilizing a machine learning based image segmentation technique, it is possible to extract pore space and grain information. Subsections of the entire image volume were used to determine anisotropic permeabilities using a finite-difference method Stokes solver (FDMSS). Additionally, permeability measurements on whole pressure and temperature preserved hydrate-bearing core were analyzed by utilizing the National Energy Technology Laboratory’s (NETL) Pressure Core Characterization and X-ray CT Visualization Tool (PCXT) to manipulate, cut, and analyze pressure preserved sediment. Permeabilities were measured under a broad range of vertical stress states to simulate expected pressure changes during production scenarios, and the results show that permeabilities derived from images are in agreement with those from traditional core derived experiments. The collected stress-dependent permeability, permeability anisotropy, and corresponding gas hydrate saturations provide valuable input into numerical simulations of reservoir productivity. These properties have been proven to be key parameters determining a long-term reservoir response under depressurization.

Liu, Mengwei [Oak Ridge Institute for Science and ↗

Multimodal Defect Imaging of Pure Tungsten Components Fabricated via Electron Beam Powder Bed Fusion

The utilization of additive manufacturing (AM) techniques for refractory materials in high-temperature environments has significantly expanded because of the ability to fabricate geometrically complex components. Electron beam powder bed fusion (EB-PBF), which provides lower residual stress, a cleaner vacuum environment, and better efficiency for high melting point, is one of the best-suited AM methods to produce advanced refractory components. However, the property variation attributed to the heterogeneous microstructure and process-induced defects has hindered the widespread adoption of EB-PBF-produced material like tungsten. While numerous in-situ monitoring and defect detection methods have been demonstrated for EB-PBF, a workflow that compares and evaluates process-induced abnormalities from different imaging perspectives is still limited. This study examines a feature-embedded tungsten component manufactured via the EB-PBF process to demonstrate the defect detection capabilities of a multimodal defect imaging workflow. The predefined and process-induced defects are evaluated by harnessing various imaging techniques, including in-situ electron imaging, layerwise near-infrared (NIR) imaging, post-build high-energy x-ray computed tomography (CT), and conventional destructive metallography. The results highlight the strengths and limitations of distinctive defect imaging techniques concerning specific defect types, sizes, and conditions. It was found that electron imaging can provide more abnormal detection capabilities while maintaining a higher measuring accuracy, against the conventional metallography in this case study, compared with NIR and CT imaging techniques.

36 MATERIALS SCIENCE↗

Zero-Power Analog Optical Processing

The motivation behind this research is the growing challenge of handling the massive amounts of data generated by modern imaging systems. Conventional digital image processing techniques are struggling to keep pace with the demands of high-resolution and high-speed imaging systems for remote sensing due to their high-power consumption and data storage requirements. We present a novel approach based on analog photonics to address this challenge. The proposed system utilizes a silicon-photonics-based image encoder positioned after image formation and initial optical-to-electrical conversion. The photonic encoder compresses image data using a passive disordered photonic structure to perform kernel-type random projections of the raw data. The compressed data is then processed by a back-end neural network, which reconstructs the original image with high fidelity (structural similarity exceeding 90%). Our proposed approach has the potential to compress images with ~ 1000X lower power consumption compared to digital approaches with data rates exceeding 1 terapixel/second.

97 MATHEMATICS AND COMPUTING↗

Power Electronics Materials and Bonded Interfaces - Reliability and Lifetime

The need for reliable bonded interface materials is critical to realize the performance benefits of wide-bandgap devices in power electronic modules, especially in operating temperatures greater than 150 degrees Celsius. In this paper, we investigate the thermomechanical performance of sintered copper (Cu) as a large-area attachment, bonded between Cu baseplates and active-metal-bonded substrates, under accelerated thermal shock (-40 degrees Celsius to 200 degrees Celsius) conditions. In the fabrication phase of the samples, we used different stencil patterns and found out that the grid and stripe patterns resulted in a better outgassing of the residual organics during the sintering process, thereby ensuring a substantially improved bond quality than a full-area print. The paste consisted of Cu microflakes and we performed sintering using a Budatec SP300 sintering press at 275 degrees Celsius with 15 MPa of bonding pressure for 5 minutes in a nitrogen atmosphere. Under accelerated experiments, we monitored the degradation of the sintered Cu bond in the samples through C-mode scanning acoustic microscope (C-SAM) images. To quantify the defect percentage in C-SAM images, we investigated image denoising techniques to exclude the pattern prints. Finally, we cross-sectioned a sample and obtained digital microscope images, which revealed adhesive fracture as the dominant failure mechanism.

ADVANCED PROPULSION SYSTEMS↗

Thermomechanical Degradation of Sintered Copper Under High-Temperature Thermal Shock

The need for reliable bonded interface materials is critical to realize the performance benefits of wide-bandgap devices in power electronics modules, especially in operating temperatures greater than 150 degrees C. In this paper, we investigate the thermomechanical performance of sintered copper (Cu) as a large-area attachment, bonded between Cu baseplates and active-metal-bonded substrates, under accelerated thermal shock (-40 degrees C to 200 degrees C) conditions. In the fabrication phase of the samples, we used different stencil patterns and found that the grid and stripe patterns resulted in a better outgassing of the residual organics during the sintering process, thereby ensuring a substantially improved bond quality compared to a full-area print. The paste consisted of Cu microflakes, and we performed sintering using a Budatec SP300 sintering press at 275 degrees C with 15 MPa of bonding pressure for 5 minutes in a nitrogen atmosphere. Under accelerated experiments, we monitored the degradation of the sintered Cu bond in the samples through C-mode scanning acoustic microscope (C-SAM) images. To quantify the defect percentage in C-SAM images, we investigated image denoising techniques to exclude the pattern prints. Finally, we cross-sectioned a sample and obtained scanning electron microscope images, which revealed adhesive fracture as the dominant failure mechanism.

ADVANCED PROPULSION SYSTEMS,INORGANIC, ORGANIC, PH↗

Probing Plasmonic Near-Fields in Oxide-Modified Aluminum Nanocubes Using Photon-Induced Near-Field Electron Microscopy

Plasmonic nanoparticles generate strong electric fields near their surface upon photoexcitation, enabling applications in sensing, spectroscopy, and photocatalysis. Electron microscopy techniques – such as cathodoluminescence and electron energy loss spectroscopy – have been leveraged to produce nanoscale maps of localized surface plasmon (LSP) modes. More recently, photon-induced near-field electron microscopy (PINEM) has emerged as a powerful technique for imaging evanescent near-fields generated by ultrafast laser excitation. In this work, we employ PINEM within an ultrafast electron microscope, complemented by numerical calculations to investigate how optical polarization, surface modification, and light intensity affect the evanescent fields associated with LSPs on oxide-modified aluminum nanocubes. Polarization control of the incident light field enables spatial mapping of the nanocube’s LSPs at the single particle level. Systematic variation of the oxide layer thickness reveals that increased coating thickness correlates with a stronger PINEM signal and a greater energy gain of probing electrons. Additionally, higher light intensities at fixed polarization and oxide coating further amplify the PINEM signal. These findings demonstrate the utility of PINEM as a high-resolution technique for optical near-field imaging and spectroscopy of single plasmonic nanoparticles. The ability to probe single particle behavior offers new opportunities for advancing the design and characterization of nanophotonic and plasmonic materials.

PINEM↗

Resolving the Electron Plume within a Scanning Electron Microscope

Scanning electron microscopy (SEM), a century-old technique, is today a ubiquitous method of imaging the surface of nanostructures. However, most SEM detectors simply count the number of secondary electrons from a material of interest, and thereby overlook the rich material information contained within them. Here, by simple modifications to a standard SEM tool, we resolve the momentum and energy information on secondary electrons by directly imaging the electron plume generated by the electron beam of the SEM. Leveraging these spectroscopic imaging capabilities, our technique is able to image lateral electric fields across a prototypical silicon p–n junctions and to distinguish differently doped regions, even when buried beyond depths typically accessible by SEM. Intriguingly, the subsurface sensitivity of this technique reveals unexpectedly strong surface band bending within nominally passivated semiconductor structures, providing useful insights for complex layered component designs, in which interfacial dynamics dictate device operation. Further, these capabilities for noninvasive, multimodal probing of complicated electronic components are crucial in today’s electronic manufacturing but is largely inaccessible even with sophisticated techniques. These results show that seemingly simple SEM can be extended to probe complex and useful material properties.

36 MATERIALS SCIENCE↗

Adjustable collimation for dark-field proton radiography contrast enhancement

A dark-field imaging condition established through pre- and post-object beam collimation has been tested for a variety of different settings at the proton radiography facility (pRad) at Los Alamos National Laboratory. This technique facilitates imaging of thin samples and materials with small areal density changes with 800 MeV protons that would otherwise appear nearly transparent for high energy protons. In the configuration that was examined, the pre-object (upstream) collimator is utilized to remove protons with large scattering angles prior to the target object. The post-object collimation entails a combination of a conventional collimator, which eliminates protons with large scattering angles after target interaction, and an inverse collimator. The inverse collimator removes unscattered protons traveling on the beam axis and those with smaller scattering angles up to a desired angle. This establishes a dark-field condition by permitting solely protons that exhibit scattering angles from target interaction within a designated range to contribute to the image. This study explores the potential of combining different sized collimators for pre- and post-object collimation. The objective is to optimize contrast for a range of samples with minimal areal density variations. A series of dark-field conditions are explored employing a remote-controlled collimator wheel and the contrast-to-noise ratio, spatial resolution, and proton transmission are compared for those combinations. It is found that the contrast-to-noise ratio can be substantially enhanced for thin samples and low areal density objects, thereby facilitating capturing high-contrast images of objects that were previously invisible to high energy protons.

43 PARTICLE ACCELERATORS↗

Accurate shear estimation with fourth-order moments

ABSTRACT As imaging surveys progress in exploring the large-scale structure of the Universe through the use of weak gravitational lensing, achieving sub-per cent accuracy in estimating shape distortions caused by lensing, or shear, is imperative for precision cosmology. In this paper, we extend the Fourier power function shapelets (FPFS) shear estimator using fourth-order shapelet moments and combine it with the original second-order shear estimator to reduce galaxy shape noise. We calibrate this novel shear estimator analytically to a sub-per cent level-accuracy using the AnaCal framework. This higher order shear estimator is tested with realistic image simulations, and after analytical correction for the detection/selection bias and noise bias, the multiplicative shear bias $|m|$ is below $3\times 10^{-3}$ (99.7 per cent confidence interval) for both isolated and blended galaxies. Once combined with the second-order FPFS shear estimator, the shape noise is reduced by $\sim 35~{{\ \rm per\ cent}}$ for isolated galaxies in simulations with Hyper Suprime-Cam and Vera C. Rubin Observatory Legacy Survey of Space and Time observational conditions. However, for blended galaxies, the effective number density does not significantly improve with the combination of the two estimators. Based on these results, we recommend exploration of how this framework can further reduce the systematic uncertainties in shear due to point spread function leakage and modelling error, and potentially provide improved precision in shear inference in high-resolution space-based images.

79 ASTRONOMY AND ASTROPHYSICS↗

Chasing ghosts: characterization of artifact generation in coded aperture decoding due to experimental implementation

Coded aperture imaging is a form of lensless aperture imaging that projects multiple overlapping images of the source onto the detector, enhancing signal strength, which is advantageous for low-flux sources or high-resolution imaging. This technique requires decoding of the detector signal to reconstruct the original source, which involves convolving the detector data with the aperture pattern. When the signal is from a centered point source, the reconstructed source image is known as the point spread function (PSF). A clean PSF without artifacts is a Dirac delta function [Appl. Opt. 20, 1858 (1981)]. This paper examines the robustness of the decoding process against variations in experimental tolerances by analyzing artifact growth in the reconstructed PSF. We illustrate the effects of incorrect magnification, rotation, and detector size and find that aperture–detector rotational misalignment about the imaging axis is the most sensitive parameter, with significant artifact generation occurring with angular offsets of less than one degree. We discuss compensation methods for imperfect aperture placement, finding that small detector sizes produce uncompensatable artifact generation, and compare theoretical predictions with experimental PSF measurements of a rank , 6.8 mm thick (less than one mean free path) coded aperture with a 3.5 mm cell size, conducted at the MegaJOuLe Neutron Imaging Radiography dense plasma focus [IEEE Trans. Plasma Sci. 49, 3299 (2021)] using a 2.45 MeV neutron source. Based on our findings, we recommend using magnified coded apertures in the under-sampled regime, which allows for the inclusion of fiducial markers to characterize aperture–detector rotational offsets and the addition of mechanical coupling, where possible, to constrain rotational and magnification offsets.

Selwood, M. P. [Lawrence Livermore National Labora↗

Multitiered computational methodology for extracting three-dimensional rotational diffusion coefficients from x-ray photon correlation spectroscopy data without structural information

X-ray photon correlation spectroscopy (XPCS) is a powerful technique for analyzing particle systems by investigating their dynamics in suspensions across a broad range of temporal and spatial scales. This is done by illuminating samples with coherent x-ray beams and calculating the correlation function of the obtained x-ray scattering images. XPCS is uniquely suited for studying Brownian dynamics, consisting of translational and rotational diffusion. While traditional XPCS image analysis techniques can extract translational diffusion components, they are unable to estimate rotational diffusion coefficients. Here, we introduce a methodology that combines the angular-temporal cross-correlation analysis and a algorithmic framework called Multi-Tiered Estimation for Correlation Spectroscopy in 3D for estimating three-dimensional rotational diffusion coefficients from XPCS images of three-dimensional particle systems. We demonstrate our methodology for extracting rotational diffusion coefficients from XPCS data by applying it to simulated noisy x-ray images of systems of crossing nanotubes and proteins that evolve under translational and rotational Brownian motion for different diffusion rates. Furthermore, our results show that our approach determines rotational diffusion coefficients within a few percent error.

97 MATHEMATICS AND COMPUTING↗

Iterative Reconstruction for Multimodal Neutron Tomography

Here, we describe a unified framework for model-based iterative 3-D reconstruction of multimodal neutron transmission, hydrogen-scatter, and induced-fission images from low resolution data recorded using 14.1-MeV neutrons and the associated-particle imaging (API) technique. The framework, which was developed to facilitate use in challenging field-deployment scenarios, is centered around physics-based system models and a total variation (TV) constrained implementation of the simultaneous iterative reconstruction technique (SIRT). Modified to solve a statistically weighted least squares (WLS) problem, the SIRT algorithm is accelerated using ordered subsets and Nesterov’s momentum for which we derive a near-optimal value of the governing Lipschitz constant. The approach enables the reconstruction of images that are high resolution compared to the acquired data and is robust to both limited statistics and a limited number of projection angles. Moreover, the framework is fast enough to be practical. Example images are provided that demonstrate both the ability to perform fast-neutron imaging of high-atomic-number materials with low radiation dose and the benefit of multimodal neutron imaging to identify key materials.

Hydrogen scatter↗

Ray-tracing image simulations of transparent objects with complex shape and inhomogeneous refractive index

Optical images of transparent three-dimensional objects can be different from a replica of the object’s cross section in the image plane, due to refraction at the surface or in the body of the object. Simulations of the object’s image are thus needed for the visualization and validation of physical models. We report ray tracing image simulations that achieved high physical fidelity, reproducing optical behaviors and image features not rendered in previous studies. We replicated brightfield microscopy images of drops with complex shapes, and images of pressure and shock waves traveling inside them. For high physical fidelity, the simulations must replicate the spatial and angular distribution of illumination rays, and both the experiment and the simulation must be designed for accurate optical modeling. The simulations are highly sensitive to the properties of the drops and can be used to diagnose and refine fluid dynamics models. The simulated images can also be optimized to extract multiple 3D properties from experimental images. Compared to specialized single-shot 3D imaging methods, this approach has the advantage that it preserves the experimental simplicity, the high resolution, and the visual interpretability characteristic to basic optical imaging. The techniques introduced here are directly applicable to optical microscopy, so they can be used in other fields, such as microfluidics and biology, to expand the type and the accuracy of three-dimensional information that can be extracted from basic optical images.

Cavitation↗

Atomic resolution scanning transmission electron microscopy at liquid helium temperatures for quantum materials

Fundamental quantum phenomena in condensed matter, ranging from correlated electron systems to quantum information processors, manifest their emergent characteristics and behaviors predominantly at low temperatures. This necessitates the use of liquid helium (LHe) cooling for experimental observation. Atomic resolution scanning transmission electron microscopy combined with LHe cooling (cryo-STEM) provides a powerful characterization technique to probe local atomic structural modulations and their coupling with charge, spin and orbital degrees-of-freedom in quantum materials. However, achieving atomic resolution in cryo-STEM is exceptionally challenging, primarily due to sample drifts arising from temperature changes and noises associated with LHe bubbling, turbulent gas flow, etc. In this work, we demonstrate atomic resolution cryo-STEM imaging at LHe temperatures using a commercial side-entry LHe cooling holder. Firstly, we examine STEM imaging performance as a function of He gas flow rate, identifying two primary noise sources: He-gas pulsing and He-gas bubbling. Secondly, we propose two strategies to achieve low noise conditions for atomic resolution STEM imaging: either by temporarily suppressing He gas flow rate using the needle valve or by acquiring images during the natural warming process. Lastly, we show the applications of image acquisition methods and image processing techniques in investigating structural phase transitions in Cr 2 Ge 2 Te 6 , CuIr 2 S 4 , and CrCl 3 . In conclusion, our findings represent an advance in the field of atomic resolution electron microscopy imaging for quantum materials and devices at LHe temperatures, which can be applied to other commercial side-entry LHe cooling TEM holders.

36 MATERIALS SCIENCE↗