Search NASA⌕ Search

SEARCH · Search NASA

Results for “impedance spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Bismuth Subcarbonate Decorated Reduced Graphene Oxide Nanocomposite for the Sensitive Stripping Voltammetry Analysis of Pb(II) and Cd(II) in Water

In this paper, bismuth subcarbonate (BiO)2CO3-reduced graphene oxide nanocomposite incorporated in Nafion matrix ((BiO)2CO3-rGO-Nafion) was synthesized and further applied, for the first time, in the sensitive detection of Pb(II) and Cd(II) by square-wave anodic stripping voltammetry (SWASV). The as-synthesized nanocomposites were characterized by energy-dispersive spectroscopy (EDS), Raman spectroscopy, scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). (BiO)2CO3 composite plays a key role in the improvement of the detection sensitivity, which can form multicomponent alloy with cadmium and lead. Additionally, the unique structure of rGO can enlarge the surface area and provide abundant active sites. Moreover, Nafion incorporation in the nanocomposite can effectively increase the adhesion and mechanical strength of the film, and further improve the preconcetration ability due to the cation-exchange capacity of its abundant sulfonate groups. As expected, the (BiO)2CO3-rGO/Nafion nanocomposite-modified glassy carbon electrode ((BiO)2CO3-rGO-Nafion/GCE) achieved low detection limits of 0.24 μg/L for Pb(II) and 0.16 μg/L for Cd(II), in the linear range of 1.0–60 μg/L, and showed some excellent performance, such as high stability, good selectivity, and sensitivity. Finally, synthetic water samples were prepared and further used to verify the practicability of the (BiO)2CO3-rGO-Nafion/GCE with satisfactory results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Corrosion Susceptibility of Cr–Mo Steels and Ferritic Stainless Steels in Biomass-Derived Pyrolysis Oil Constituents

In this work, to better understand and evaluate the corrosion performance of candidate structural steels and ferritic stainless steels for production, transport, and storage of biomass pyrolysis oils, corrosion studies were conducted in selected organic constituents of bio-oils, including catechol, formic acid, and their mixtures as well as lactobionic acid, using electrochemical impedance spectroscopy. R 2 , the resistance against corrosion reaction, was obtained by fitting measured impedance spectra into an equivalent circuit. The values of R 2 were then used to assess corrosion resistance of the steels in each organic constituent and mixture. Type 410 and 430 stainless steels were resistant to corrosion in all tested organic constituents, while 2.25Cr-1Mo steel was not. 9Cr-1Mo steel was corrosion resistant in catechol but not in the other mixtures that contained organic acids. On the basis of the results of this work, it is suggested that the corrosion resistance against organic acids is attributed to formation of a Cr-rich passive film that requires stainless steels with critical Cr levels in excess of approximately 11 wt %. In catechol-only solution, lower levels of Cr intermediate between that of 2.25Cr-1Mo steel and 9Cr-1Mo steel appeared sufficient.

36 MATERIALS SCIENCE↗

Deconvoluting the benefits of porosity distribution in layered electrodes on the electrochemical performance of Li-ion batteries

Thick Lithium Ion Battery (LIB) electrodes suffer from poor rate capability and high ionic impedance due to their thickness and mesostructure. Therefore, optimizing thick electrode architectures becomes crucial. In this work, we report a systematic assessment of the ionic resistance in heterogeneous porous electrodes through the combination of computational simulations using a 4D-resolved model and experimental measurements. The first part of the study is devoted to a general assessment of Electrochemical Impedance Spectroscopy (EIS) spectra, mapping the impact of ionic and electronic resistances on the overall impedances of uncalendered and calendered LiNi 1/3 Mn 1/3 Co 1/3 O 2 , LiFePO 4 and graphite electrodes. In the second part, in silico-generated electrodes with different porosities are used in computational EIS simulations to analyze the impact of the electrode porosity on the ionic impedance. As expected, the results show that a lower porosity leads to a higher ionic impedance because of a higher electrode tortuosity factor. Furthermore, in silico-generated electrodes with different porosities were stacked and assembled to create heterogeneities of porosity along the thickness, and used in computational EIS and galvanostatic discharge simulations. The computational results show that the porosity heterogeneity along the electrode thickness has a significant effect on the ionic impedance and capacity of the electrode. The electrode architecture with progressively decreasing porosity from separator to current collector shows the highest performance, a trend validated by our in house experimental EIS and galvanostatic discharge also reported in this manuscript. Overall, we conclude that the ionic resistance in a thick electrode can be effectively reduced through proper tuning of the porosity heterogeneity. The proposed heterogeneous electrode architectures presented here could enormously help building efficient thick electrodes for LIBs.

25 ENERGY STORAGE↗

Corrosion Behavior of Hydrophobic Coatings in Aqueous CO2 Environments

Internal corrosion is caused by gas impurities such as CO2, moisture, and H2S, leading to material degradation. To combat this, the National Energy Technology Laboratory (NETL) developed a novel hydrophobic coating to reduce surface hydrophobicity and enhance the corrosion resistance of steel. NETL’s approach uses multi-layer hydrophobic coatings, a novel and promising coating that could potentially revolutionize the industry's approach to internal corrosion mitigation. This work aims to investigate the corrosion performance of the hydrophobic coating and determine the water uptake. Electrochemical corrosion experiments were carried out on bare X65 carbon steel without and with coating in 3.5 wt.% NaCl saturated with CO2 at 20 °C to follow the water uptake as a function of exposure time. Linear polarization resistance (LPR) was used to determine the corrosion rate for carbon steel immersed in a NaCl electrolyte saturated with CO2. Electrochemical impedance spectroscopy (EIS) of uncoated and coated bare carbon steel was investigated. The analyses of impedance models and water uptake behaviors of hydrophobic coatings were studied for 200 hours during the corrosion process. The water uptake was estimated using the Brasher and Kingsbury relation. The results showed that the superhydrophobic coating that was developed used innovative nano-based materials to act as protection layers on the surface of metallic parts against mechanical aggressors, corrosion, and fouling agents.

corrosion behavior↗

LiNi x Fe y Al z O 2 , a new cobalt-free layered cathode material for advanced Li-ion batteries

Recently, rapid fluctuations in cobalt prices have created a worsening supply chain constraint that has become a serious cause of concern amidst global battery manufacturers. To address this challenge, we report herein a new class of cobalt-free, nickel-rich layered cathode material termed the NFA class with general formula LiNi x Fe y Al z O 2 (x + y + z = 1). Using co-precipitation reaction in a continuous stirred tank reactor, we synthesized NFA(OH) 2 precursors with the constituent Ni, Fe and Al elements successfully incorporated. The obtained LiNFAO 2 cathode was characterized using X-Ray diffraction, Mössbauer spectroscopy and scanning electron microscopy. Electrochemical behavior was assessed using cyclic voltammetry, galvanostatic charge/discharge, electrochemical impedance spectroscopy and galvanostatic intermittent titration technique at various states of lithiation/delithiation. Electrochemical performance evaluations revealed that our cobalt-free material delivers high capacity of 190 mAh/g at 0.1C. Rate and cycling performance evaluations also indicated good rate capability and cycling stability with 88% capacity retention after 100 cycles at C/3. Using NFA cathodes, we also fabricated a 0.5Ah (C/3) cobalt-free Li-ion battery which demonstrated reasonable cycling stability with ~72% capacity retained after 200 cycles. Overall, our work demonstrates the immense potential of the cobalt-free NFA class cathodes as viable candidates towards development of next generation cost effective lithium ion batteries.

25 ENERGY STORAGE↗

Nafion Inhibits Polysulfide Crossover in Hybrid Nonaqueous Redox Flow Batteries

Here, we report on the effectiveness of sodium-exchanged Nafion membranes for inhibiting polysulfide crossover during redox flow battery operation. The solubility of polysulfides allows them to be used as a high-capacity catholyte for nonaqueous redox flow batteries (NARFB). The NARFB cathode capacity is controlled by the total tank catholyte volume and polysulfide concentration and, as such, is independent of polysulfide adsorption sites on carbon fibers or nanotubes as found within traditional Na or Li–S batteries. However, one of the major barriers to the realization of polysulfide NARFBs is associated with developing a robust membrane that has minimal polysulfide crossover under the operating conditions. We found that sodium-exchanged Nafion membrane separators effectively inhibit polysulfide crossover within a Na–sulfur NARFB. These membranes significantly improve both capacity retention (70%) and Coulombic efficiencies (99%) after 50 cycles. Commercial porous membranes showed a large crossover as detected by UV–vis spectroscopy and resulted in low capacity retention (20%) and Coulombic efficiency (74%) after 45 cycles. Electrochemical impedance spectroscopy (EIS) measurements highlighted the trade-off between innate reactivity and ionic conduction of the membranes. The results show that dense, single ion conducting Nafion enables a long cycle life; however, it reacts with Na metal to form a resistive passivation layer and increases the cell resistance. On the contrary, the open pore structure of Celgard allows for higher current charge/discharge, and its chemical nature is compatible with Na; however, it has a high degree of polysulfide crossover.

25 ENERGY STORAGE↗

The Role of Functionalized Conducting Polymer Binders in Improving Power Density and Cycle Life of Lithium-Sulfur Batteries

Lithium-Sulfur batteries are promising as the next-generation of low-cost, high-energy rechargeable batteries. However, the commercialization of this battery has been limited by poor rate capability and cycle life. To improve the performance of Li-S cells, we have investigated the role of two n-dopable conducting polymers, N2200 and N2200-OE, as binders for the sulfur cathode. The electron and ion transport properties of these polymer binders, along with their strong affinity for polysulfides, results in significantly enhanced performance compared to cells with the traditional insulating PVDF binder. The role of these conducting polymer binders in enhancing the performance of the cells is analyzed using impedance spectroscopy, shuttle current measurements, conductivity measurements, UV–vis spectroscopy, GIWAXS studies and post-cycling analysis of the anodes. The conducting polymer binders reduce the cell impedance by a factor of four leading to a marked improvement in rate capability. The shuttling of the polysulfides and the formation of insoluble sulfides at the anode is curtailed by the interaction of the polysulfides with the backbone of the polymer binders, leading to an impressive capacity retention of 82% after 500 cycles. These studies demonstrate the benefit of tailored polymer binders at the sulfur electrode in addressing the limitations of lithium-sulfur batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-Cost and Portable Biosensor Based on Monitoring Impedance Changes in Aptamer-Functionalized Nanoporous Anodized Aluminum Oxide Membrane

We report a low-cost, portable biosensor composed of an aptamer-functionalized nanoporous anodic aluminum oxide (NAAO) membrane and a commercial microcontroller chip-based impedance reader suitable for electrochemical impedance spectroscopy (EIS)-based sensing. The biosensor consists of two chambers separated by an aptamer-functionalized NAAO membrane, and the impedance reader is utilized to monitor transmembrane impedance changes. The biosensor is utilized to detect amodiaquine molecules using an amodiaquine-binding aptamer (OR7)-functionalized membrane. The aptamer-functionalized membrane is exposed to different concentrations of amodiaquine molecules to characterize the sensitivity of the sensor response. The specificity of the sensor response is characterized by exposure to varying concentrations of chloroquine, which is similar in structure to amodiaquine but does not bind to the OR7 aptamer. A commercial potentiostat is also used to measure the sensor response for amodiaquine and chloroquine. The sensing response measured using both the portable impedance reader and the commercial potentiostat showed a similar dynamic response and detection threshold. The specific and sensitive sensing results for amodiaquine demonstrate the efficacy of the low-cost and portable biosensor.

60 APPLIED LIFE SCIENCES↗

Surface Immobilization of a Re(I) Tricarbonyl Phenanthroline Complex to Si(111) through Sonochemical Hydrosilylation

A sonochemical-based hydrosilylation method was employed to covalently attach a rhenium tricarbonyl phenanthroline complex to silicon(111). fac-Re(5-(p-Styrene)-phen)(CO) 3 Cl (5-(p-styrene)-phen = 5-(4-vinylphenyl)-1,10-phenanthroline) was reacted with hydrogen-terminated silicon(111) in an ultrasonic bath to generate a hybrid photoelectrode. Subsequent reaction with 1-hexene enabled functionalization of remaining atop Si sites. Attenuated total reflectance–Fourier transform infrared spectroscopy confirms attachment of the organometallic complex to silicon without degradation of the organometallic core, supporting hydrosilylation as a strategy for installing coordination complexes that retain their molecular integrity. Detection of Re(I) and nitrogen by X-ray photoelectron spectroscopy (XPS) further support immobilization of fac-Re(5-(p-styrene)-phen)(CO) 3 Cl. Cyclic voltammetry and electrochemical impedance spectroscopy under white light illumination indicate that fac-Re(5-(p-styrene)-phen)(CO) 3 Cl undergoes two electron reductions. Mott–Schottky analysis indicates that the flat band potential is 239 mV more positive for p-Si(111) co-functionalized with both fac-Re(5-(p-styrene)-phen)(CO) 3 Cl and 1-hexene than when functionalized with 1-hexene alone. XPS, ultraviolet photoelectron spectroscopy, and Mott–Schottky analysis show that functionalization with fac-Re(5-(p-styrene)-phen)(CO) 3 Cl and 1-hexene introduces a negative interfacial dipole, facilitating reductive photoelectrochemistry.

X-ray photoelectron spectroscopy↗

Relationship of Chemical Composition and Moisture Sensitivity in LiNi x Mn y Co 1-x-y O 2 for Lithium-Ion Batteries

Chemical composition–moisture sensitivity relationship of LiNi x Mn y Co 1-x-y O 2 (NMC) cathode materials was investigated by exploring crystal structures, surface properties, and electrochemical performance behaviors of various commercial NMC powders: LiNi 1/3 Mn 1/3 Co 1/3 O 2 (NMC111), LiNi 0.5 Mn 0.3 Co 0.2 O 2 (NMC532), LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622), and LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811). The NMC powders were stored in different moisture conditions: moisture-free, humidified air, or immersed in water. Rietveld refinement analysis of X-ray diffraction (XRD) data and scanning electron microscopy (SEM) were used to characterize the crystal structure changes and the evolution of particle surfaces morphologies. The effect of moisture contamination on the electrochemical properties of NMC cathodes was studied by galvanostatic cycling and electrochemical impedance spectroscopy (EIS). The moisture contamination resulted in either structural disorder or unwanted surficial deposition products, which increased a charge-transfer impedance and consequent performance degradation of battery cells. The results showed that NMC’s moisture vulnerability increased with Ni content (x) despite protective coatings on commercial particles, which stressed the necessity of alternative surface passivation strategies of Ni-rich NMC for broad applications such as electric vehicles and electrified aircraft propulsion.

25 ENERGY STORAGE↗

Lowering the Impedance of Lanthanum Strontium Manganite-Based Electrodes with Lanthanum Oxychloride and Lanthanum Scavenging Chloride Salts

The impact of infiltrating chloride salts on the electrochemical behavior of lanthanum strontium manganite-yttria stabilized zirconia (LSM-YSZ) cathodes was investigated under solid oxide fuel cell operation. Infiltrating a lanthanum chloride solution resulted in the formation of a lanthanum oxychloride (LaOCl) phase. A LaOCl phase also formed by infiltrating an ammonium chloride solution; however, lanthanum was scavenged from the LSM phase to form LaOCl. The third infiltrating solution, a combination of zirconium chloride and yttrium nitrate, formed LaOCl by scavenging lanthanum from LSM and produced YSZ nanoparticles. Electrochemical impedance spectroscopy results suggest that LaOCl improves oxygen adsorption kinetics compared to a baseline LSM-YSZ cathode, reducing the low frequency impedance by 30%. In addition, scavenging lanthanum from LSM improved oxygen ion diffusion polarization as indicated by the observed 40% reduction in high frequency impedance and improved serial ohmic resistance by 19%. Finally, YSZ nanoparticles further reduced the high frequency impedance and ohmic resistance by 45% and 23%, respectively. The findings reveal new strategies for lowering the impedance of LSM-YSZ cathodes.

Taylor, Thomas H.↗

Chemical and Electrochemical Characterization of Hot–Pressed Li 6 PS 5 Cl Solid State Electrolyte: Operating Pressure–Invariant High Ionic Conductivity

Sulfide solid state electrolytes (SSE) are among the most promising materials in the effort to replace liquid electrolytes, largely due to their comparable ionic conductivities. Among the sulfide SSEs, Argyrodites (Li 6 PS 5 X, X=Cl, Br, I) further stand out due to their high theoretical ionic conductivity (~1×10 –2 S cm –1 ) and interfacial stability against reactive metal anodes such as lithium. Generally, solid state electrolyte pellets are pressed from powder feedstock at room temperature, however, pellets fabricated by cold pressing consistently result in low bulk density and high porosity, facilitating interfacial degradation reactions and allowing dendrites to propagate through the pores and grain boundaries. Here, we demonstrate the mechanical and electrochemical implications of hot-pressing standalone LPSCl SSE pellets with near-theoretical ionic conductivity, superior cycling performance, and enhanced mechanical stability. X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and x-ray diffraction spectroscopy (XRD) analysis reveal no chemical changes to the Argyrodite surface after hot pressing up to 250°C. Furthermore, we use electrochemical impedance spectroscopy (EIS) to understand mechanical stability of Argyrodite SSE pellets as a function of externally applied pressure, demonstrating for the first time pressed standalone Argyrodite pellets with near-theoretical conductivities at external pressures below 14 MPa.

25 ENERGY STORAGE↗

Designing an impedance-based technique for studying corrosion on cladding materials

In nuclear cladding materials, changes in structure and chemistry over the lifetime of claddings can have a significant impact on fuel and reactor performance. Currently, chemical evolution over the lifetime of the fuel and cladding materials can only be inferred using post-irradiation examination. As an alternative to post-irradiation measurements, electrochemical impedance spectroscopy (EIS) can provide an in-pile measurement of changes in chemistry in oxides and hydrides. The objective of this study is to develop an impedance based sensing technology for measuring spatial- and time-resolved in-pile changes in cladding chemistry in order to understand the mechanisms of hydride formation, hydride dealloying and associated cladding corrosion so that a mitigation strategy and technology can be developed for reactor safe operation. Two prototype impedance-based sensors were designed and assembled using Zr-4 as working electrode and Pt as counter and reference electrode. One sensor is tubular type and the other one is plate-type. These sensors will be tested in static autoclave to investigate the effects of various environmental conditions (including temperature, pressure, and water chemistry) on cladding material corrosion mechanisms. These in-situ EIS sensors would provide corrosion-layer parameters in high-temperature water, such as (1) total layer thickness, (2) the evolution of oxide structures as uniform layer dielectric or sublayer(s), and (3) the possible electrochemistry of the volume corrosion process and the solid/liquid interface, such as the cyclic nature of corrosion of Zr alloys in high-temperature water. This work was focused on electrochemical sensor development, targeting cladding oxides/hydrides under thermodynamic equilibria; characterization of samples using Kelvin probe force microscopy (SKPFM), Raman spectroscopy, and scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) to provide high-resolution co-localized characterization of zirconium oxide and metal/oxide interface.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Local Structural Coherence and Interfacial Charge Transfer in Cu 2 ⁢S/Mo⁢S 2 Heterostructure

Precise control over electronic coupling at nanoscale interfaces is critical for designing materials with tunable charge-transfer behavior and catalytic function. Heterostructures with locally coherent interfaces provide a platform for interrogating interfacial charge redistribution in coupled material systems. Here, we report Cu 2 ⁢S/Mo⁢S 2 heterostructures exhibiting nanoscale crystallographic alignment, which are synthesized through a rapid thermal transformation pathway. We employed electrochemical reduction reactions to probe interfacial charge transfer, revealing shifts in product distribution attributable to modified interfacial energetics, even in the absence of optimized catalytic performance. The observed formate Faradaic efficiency suggests that interfacial electronic modulation in the heterostructure shifts product selectivity towards formate, highlighting how interface-driven electronic modulation can direct reaction pathways and influence product selectivity. Optimizing catalyst loading, architecture, and reactor configuration will be critical for future improvement. Structural and compositional integrity were confirmed through powder x-ray diffraction, x-ray photoelectron spectroscopy, and high-resolution transmission electron microscopy. Electron transfer between Cu 2 ⁢S and Mo⁢S 2 domains was further evaluated by electrochemical impedance spectroscopy, while selected-area electron diffraction revealed local crystallographic alignment consistent with a local epitaxial relationship at the Cu 2 S/Mo⁢S 2 heterointerface. To illustrate the broader applicability of this approach, a Zn⁢S/Mo⁢S 2 heterostructure was also synthesized using the same microwave strategy, confirming the generalizability of interfacial engineering principles across metal sulfide-Mo⁢S 2 systems. Collectively, these findings demonstrate that controlled local epitaxial alignment serves as an effective design principle for tuning interfacial energetics and catalytic reactivity in complex heterostructure materials.

carbon capture & utilization↗

Increasing Multilayer Ceramic Capacitor Lifetime With Bipolar Voltage Cycling

Enhancing the lifetime of multilayer ceramic capacitors (MLCCs) is critical in many aerospace, naval, or electrical grid applications, where device failure could lead to catastrophic consequences. The migration of oxygen vacancies from the ceramic to the electrode interface under constant bias is known to reduce the lifetime of oxide-based MLCCs. Bias cycling presents an opportunity to enhance MLCC lifetime by reducing oxygen vacancy migration. The ideal frequency range is expected to lie between frequencies low enough to avoid self-heating but high enough to avoid interfacial defect formation. However, the impact of low-frequency bipolar voltage cycling (BVC) on MLCC degradation mechanisms has not been well studied. This work investigates the impact of periodic BVC on the degradation of MLCCs through highly accelerated lifetime testing (HALT) on X7R capacitors. HALT tests were conducted at 255 °C and 60 V using different switching frequencies: 0 (dc), 0.1, 2.5, and 10 Hz. BVC was found to improve the lifetime of MLCCs compared to dc test conditions. MLCCs tested at 10-Hz BVC showed a 311% increase in average time to failure compared to the dc case. Impedance spectroscopy shows that BVC decreases the rate of resistance degradation within MLCCs, indicating that oxygen vacancy migration to the electrodes is mitigated. The impedance spectra taken on BVC samples highlight how grain boundaries play a vital role in trapping oxygen vacancies. Periodic cycling causes oxygen vacancies to become trapped at grain boundaries, resulting in oxygen vacancies taking longer to reach the electrode interface and thus increasing MLCC lifetime. This work highlights not only how BVC can be used to increase MLCC lifetime but also how periodically cycling MLCCs could increase lifetime in extreme environments, such as at elevated temperatures and electric fields.

Chuong, Kayla Y.↗

Delineating the kinetic limitations of Mn 2+/3+ redox in LiMn x Fe 1−x PO 4 cathodes for lithium-ion batteries

LiMn x Fe 1−x PO 4 (LMFP) cathodes offer higher energy density than LiFePO 4 due to a higher operating voltage. However, the kinetic limitations of the Mn 2+/3+ redox couple in LMFP restrict its practically achievable capacity and hinder the ability to achieve high energy density. While the shortcomings of Mn 2+/3+ redox are recognized, its behavior and the factors that impact it remain to be fully understood. We present here an in-depth kinetics study of LMFP by utilizing novel techniques, such as chronoamperometry and galvanostatic electrochemical impedance spectroscopy. Compared to moderate-Mn LMFP (40–60% Mn), high-Mn LMFP (80% Mn) experiences reduced capacity, poor rate capability, and heightened impedance during Mn 2+/3+ redox. The oxidation of Mn 2+ to Mn 3+ becomes more resistive during charge due to the formation of Jahn–Teller active Mn 3+ and the increasing charge-transfer insulating behavior of Mn x Fe 1−x PO 4 . However, the impedance associated with Mn 3+ to Mn 2+ reduction remains constant during discharge in the entire region. The protracted Mn2+ oxidation in high-Mn LMFP results in excessive impedance compared to that in moderate-Mn LMFP, even at low C-rates and high cycling temperatures. Despite the promise of high energy density, the extreme kinetic limitations inherent to high-Mn LMFP present a barrier.

25 ENERGY STORAGE↗

Impedance-Based State-of-Health Estimation for Lithium-Ion Battery Management Systems

This paper discusses an impedance-based state-of-health (SOH) estimation for lithium-ion battery management systems. Features obtained from the Nyquist plot of the electrochemical impedance spectroscopy (EIS) are utilized to estimate the SOH. Two commercial lithium-ion batteries were aged (cycled) in the laboratory to collect aging and impedance data. An algorithm for SOH estimation is presented and evaluated. The performance evaluation results show that the SOH features extracted from the Nyquist plot can be utilized for SOH estimation. Estimated SOH values can be then utilized in various battery management systems (BMS) functions such as for calibrating the available capacity, adjusting charging/discharging strategies, and protection.

Al-Smadi, Mohammad↗

Performance of a Novel In-Situ Converted Additive for High Voltage Li-ion Pouch Cells

In search for new classes of additives for high voltage NMC/graphite lithium-ion cells, the precursor additive bis(trimethylsilyl) malonate (bTMSM) is shown to be activated via a spontaneous reaction with LiPF 6 and LiBF 4 salts in carbonate-based electrolyte to form lithium tetrafluoro(malonato)phosphate (LiTFMP), and lithium difluoro(malonato)borate (LiDFMB), respectively. The reaction schemes and rates were studied via NMR spectroscopy and GCMS. The effects of LiTFMP and LiDFMB on high voltage electrochemical performance were then examined up to 4.5 V in Li[Ni 0.4 Mn 0.4 Co 0.16 ]O 2 (NMC442)/graphite and Li[Ni 0.6 Mn 0.4 Co 0.0 ]O 2 (NMC/640)/graphite pouch cells using aggressive voltage-hold cycling, long-term charge/discharge cycling, storage experiments, electrochemical impedance spectroscopy, and gas evolution measurements. While in situ converted additives suffer from gassing issues due to the presence of trimethylfluorosilane (TMSF) gas, a side product of the in situ reaction of bTMSM with LiPF 6 , the cycling and storage capability for the activated additives under study shows competitive performance and controlled impedance when compared to other well-known high voltage additives. Micro X-ray fluorescence spectroscopy (μXRF) confirmed that LiTFMP successfully minimizes the rate of transition metal deposition on the surface of graphite apparently by forming a protective agent at the cathode surface, hence allowing for improved cycling performance at high voltages.

25 ENERGY STORAGE↗