Search NASA⌕ Search

SEARCH · Search NASA

Results for “inlet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Construction of 3D MHD pressure drop correlation and flow characterization in the contraction region of a fusion blanket manifold

Inlet and outlet manifolds are typical components of liquid metal (LM) blanket designs of a fusion power reactor to be used to distribute the LM flow into breeding channels and collect it at the exit of the blanket. High pressure loss in the magnetohydrodynamic (MHD) flows featuring abrupt geometrical changes is one of the main feasibility issues of such designs. Recently, optimization studies were conducted to construct 3D MHD pressure drop correlations for a LM flow in an electrically insulating manifold with gradual expansion. Here, the 3D computational approach developed in that study is applied to the outlet manifold featuring gradual contraction. A systematic analysis was performed with a total number of 135 flow cases computed with COMSOL Multiphysics for Hartmann numbers 1000 < Ha < 10,000, Reynolds numbers 100 < Re < 12,000, and contraction angles 45° < θ < 75° for a fixed contraction ratio of 4. The effects of Ha, Re and θ on the flow recirculation, development length and the total pressure drop were carefully examined. A linear regression analysis was used to determine the power rule of pressure drop coefficient k related to Ha and Re, demonstrating a good match with the Ludford layer theory. Eventually, a correlation for the 3D MHD pressure drop coefficient was constructed as a function of Ha, Re and θ. Further, the results were compared against the inlet manifold. It was found that the flow in the inlet manifold exhibits larger recirculation zones. In the investigated range of Ha, Re and θ, the pressure drop coefficient k of the LM MHD flow in the gradual contraction is only slightly lower (< 8 %) than that in the gradual expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Ball Motion and Near-Field Spray Characteristics of a Gasoline Direct Injection Injector using an X-ray Phase-Contrast Imaging Technique under High-Injection Pressures

Here, the purpose of this study is to visualize the ball (needle) motion and near-field spray characteristics of a gasoline direct injection injector under different injection conditions and analyze the effect of the internal structure of the injector on the ball motion, near-field spray velocity, and post-injection process. The injection pressure is set to 10MPa, 20 MPa, and 30 MPa, and the energization duration is fixed at 1.5 ms. An advanced X-ray technique with high transmittance and low scattering, is used to visualize the internal structure and near-field spray characteristics of the injector, which is impossible with general light sources. The ball is found to tilt to the right in the Y-axial direction during stable motion because the driving force of fuel on the ball is larger on the left side owing to the larger distance of the ball from the left wall. In addition, during stable motion, the near-field velocity of a hole with a smaller inlet angle is significantly higher than that of a hole with a larger inlet angle. The hole with a smaller inlet angle display better atomization characteristics during the post-injection process under all values of injection pressure.

47 OTHER INSTRUMENTATION↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

$\mathrm{REX}$: An analytical tool for reactor operating envelope expansion through fuel-clad thermo-mechanics

Here REX, an analytical reactor design tool for the identification and expansion of reactor operating envelopes, is introduced and detailed. Written in MATLAB, REX takes core geometries and axially discretized detector and depletion output from the Serpent neutron transport code and performs full-core, pin-specific thermal-hydraulic and thermo-mechanical calculations. REX identifies the operating envelopes of advanced, solid-fuel nuclear reactors on the basis of their fuel-cladding, fuel-gas, and coolant-cladding interfacial thermo-mechanics. It iteratively pushes coolant inlet temperatures and modifies fuel pin geometries to induce mechanical failure in their original cladding materials at the fullest extent of their fuel cycle lengths and permissible coolant inlet temperatures. It then attempts to expand their operating envelopes by determining the mechanical responses of alternative cladding materials under the same geometric conditions. The result of the REX calculation sequence is a set of 5-D variables describing the temperatures, pressures, geometries, and mechanics of the core as functions of assembly, fuel pin, axial zone, depletion step, and coolant inlet temperature for each candidate cladding material with the limiting fuel pin geometry for the original material.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Topology optimization of an airfoil fin microchannel heat exchanger using artificial intelligence

High-performance microchannel heat exchangers are needed to supply heat for power conversion for nuclear microreactors. An airfoil fin microchannel design, constructed of Alloy 617 with helium as the working fluid, is analyzed and optimized using a design of experiments with artificial intelligence techniques. The use of airfoil fins offers the potential to reduce pressure drop across the heat exchanger, as compared to other types of channel configurations. A framework for topology optimization of airfoil fin printed circuit heat exchangers (PCHEs) has been developed that can be readily extended to different fin sizes and shapes, as well as different inlet and operating conditions, materials of construction, and working fluids. An optimization procedure is developed that employs computational fluid dynamics for a set of design points identified using Latin hypercube sampling. Computational fluid dynamics is used to analyze a simplified two-channel configuration where five design parameters are varied – inlet angle, fin scale, extent of staggering, transverse and longitudinal pitches. Two methods (a 5D polynomial and a regression neural network) are compared for generating surrogate models and the resulting response surface approximation is input to a genetic algorithm that is used to identify a set of optimal parameters. The optimal geometries are found across six channel Reynolds numbers ranging from 1000 to 5000, since inlet conditions affect flow through the heat exchanger. Additionally, a set of optimal designs that maximizes heat transfer and minimizes pressure drop is identified, and a thermal stress analysis is performed on the optimal design. Correlations for the Nusselt number and Darcy friction factor are developed that can be useful for thermal hydraulic analyses using system codes. Thermal stresses are analyzed and a brief discussion of the status of code cases of PCHEs for nuclear applications is given. Testing and thermomechanical modeling is needed to facilitate future code compliance of PCHEs for high pressure and high temperature applications.

42 ENGINEERING↗

High resolution numerical simulations of methane pool fires using adaptive mesh refinement

The ability to accurately predict the structure and dynamics of pool fires using computational simulations is of great interest in a wide variety of applications, including accidental and wildland fires. However, the presence of physical processes spanning a broad range of spatial and temporal scales poses a significant challenge for simulations of such fires, particularly at conditions near the transition between laminar and turbulent flow. Here, in this study, we examine the transition to turbulence in methane pool fires using high-resolution simulations with multi-step finite rate chemistry, where adaptive mesh refinement (AMR) is used to directly resolve small-scale flow phenomena. We perform three simulations of methane pool fires, each with increasing diameter, corresponding to increasing inlet Reynolds and Richardson numbers. As the diameter increases, the flow transitions from organized vortex roll-up via the puffing instability to much more chaotic mixing associated with finger formation along the shear layer and core collapse near the inlet. These effects combine to create additional mixing close to the inlet, thereby enhancing fuel consumption and causing more rapid acceleration of the fluid above the pool. We also make comparisons between the transition to turbulence and core collapse in the present pool fires and in inert helium plumes, which are often used as surrogates for the study of buoyant reacting flows.

42 ENGINEERING↗

Nondimensional convection numbers modeling thermally stratified storage tanks: Richardson's number and hot-water tanks

Thermally stratified storage tank studies have spanned over 50 years to increase the thermal storage efficiency and accurate prediction of the outlet temperature particularly for solar applications. The studies have reviewed and modeled the jet and plume flow phenomena inside the tank due to the inlet mixing and stratification level. Kelvin–Helmholtz and Rayleigh–Taylor instabilities are the major drivers of the mixing in these tanks. Momentum jets deflecting off walls at the bottom of the tank also create significant mixing. Reviewing Richardson models shows that the categorization was based on the range of Reynolds numbers at the inlet. Unfortunately, the use of superficial velocity in calculating the Richardson number results in critical values in the literature ranging from below 0.25 to 100. The most used length scale associated with these flows is an inertial scale based on the tank height or diameter although the mixing can occur at a relatively smaller scale. The various inlet devices and a large span of flow rates experienced in thermally stratified storage tanks requisite the use of the Reynolds number in combination with a convection number for accurate one dimensional models that predict performance over the long-term. The evaluation of peak shifting of electric loads leveraging renewable sources for applications, including residential hot-water tanks, commercial water tanks, and large-scale chilled water storage tanks, require these models. Finally, this paper is focused on establishing the significance of the convection numbers in conjunction with the Reynolds number for modeling the thermal stratification in storage tanks.

14 SOLAR ENERGY↗

Understanding flow dynamics in membrane distillation: Effects of reactor design on polarization

Optimization and design of full-scale membrane distillation (MD) systems usually require Sherwood and Nusselt correlations that are developed from lab-scale systems. However, entrance effects in lab-scale systems can significantly impact heat, mass and momentum transfer in the reactor, therefore affect the accuracy of the developed experimental Sherwood and Nusselt correlations. Here, Computational Fluid Dynamics (CFD) simulations using OpenFOAM are performed to understand the effects of right-angled bends and inlet design on flow dynamics, temperature and concentration polarization in MD systems. Simulation results show that the presence of right-angled bends and inlets with sudden expansions lead to the formation of Dean vortices. Dean vortices enhance perpendicular mixing in MD systems and reduce both temperature and concentration polarization. Temperature and concentration polarization coefficients in MD systems with right-angled bends and inlets with sudden expansions vary significantly for the same volumetric flow rate. Our studies show that lab-scale systems with the same volumetric flow rate but different designs lead to significantly different Nusselt and Sherwood correlations. Here, this study demonstrates the importance of CFD-informed design of lab-scale systems to minimize entrance effects and suppress Dean vortices for consistent model development and calibration across multiple scales.

42 ENGINEERING↗

Techno-economic comparison of sCO 2 cycles for particle-based CSP at design-point conditions

In this work, we compare the techno-economic performance of supercritical carbon dioxide power cycles integrated in a particle CSP system. We model four core cycle configurations: simple (with optional bypass), recompression (with optional bypass), partial cooling, and turbine split flow, which each demonstrate different benefits in a CSP system, such as high efficiency, low cost, or large HTF temperature differences. We parametrically sweep cycle design variables for each configuration. The set of power cycle performance results are then combined with a design point particle CSP system model which calculates the system specific cost. The simple cycle and turbine split flow cycles have the best performance in the baseline results, with system specific costs of 5,912 and 5,899 $\$$/kWe respectively. In addition to the baseline set of results, we also vary key parameters and costs in a sensitivity study. The cycle designs with the best system performance limit their efficiency to ~45 %, despite demonstrating higher maximum efficiencies, due to the rapid increase in cost of recuperation as efficiencies rise. The simple cycle has strong performance in the analysis and is on average only 1.4 % worse than the optimal configuration. Lowered turbine inlet temperatures from the sensitivity study improve performance by reducing the PHX and turbine cost. Decreasing the inlet temperature from 700 to 625°C results in an >8 % decrease in system specific cost. Future work should expand sensitivity analyses to colder turbine inlet temperatures and calculate system performance by simulating annual performance with off-design solar and cycle component models.

14 SOLAR ENERGY↗

Transient mixing behavior of a supercritical fluid injected into supercritical and subcritical environments

Transient, near-field mixing of a supercritical fluid injected into supercritical and subcritical environments is investigated experimentally. Fuel (propane) from a 100 μm diameter Bosch diesel injector is injected into a high-pressure test rig with a steady flow of heated, low-velocity nitrogen to control the ambient pressure and temperature. The fuel supply pressure is approximately 190 bar, allowing short injections lasting 3–4 ms to be performed in quick succession to acquire statistically significant datasets to represent the unsteady fuel–air mixing. Two test cases with the same ambient density and injector inlet pressure and temperature were chosen in an attempt to isolate effects of mixture phase behavior. Microscopic rainbow Schlieren deflectometry (RSD) is used for visualization and quantitative data acquisition. In the case of the supercritical ambient, the injector inlet and exit and ambient conditions are all supercritical. The RSD analysis reveals a mixing process similar to the single phase fluid mixing, though condensation is also observed locally, and can be explained by the adiabatic mixing theory presented in the paper. For the subcritical ambient case, the injector inlet is supercritical, but the injector exit and ambient conditions are both subcritical. The results show a rapid expansion in the near-field promoting mixing between propane and nitrogen. At downstream locations, significant condensation is also observed as predicted by the adiabatic mixing theory. As a result, the supercritical ambient case exhibited longer and narrower jet penetration compared to the subcritical ambient case.

02 PETROLEUM↗

Large eddy simulation of flow through an axisymmetric sudden expansion

Here, this study aims at investigating the inlet flow conditions of flow through an axisymmetric sudden expansion with an expansion ratio of 2.0. A series of large eddy simulations with the WALE model were conducted for different inlet Reynolds numbers ( Re) and turbulence intensities ($u_{rms}/\bar{U}_m$). The reattachment length, defined as the length measured downstream of the expansion where the flow direction is reversed adjacent to the wall ( Lr), was measured for each case. For widely studied inlet turbulence intensity values (TI), the simulation results are in good agreement with the experimental and numerical results reported in the literature. Parametric studies revealed that turbulence intensity affects the critical Reynolds number, marking the transition between the laminar and transition regions and the reattachment length. The critical Reynolds number was found to decrease with increasing turbulence intensity. A correlation expression is proposed. Additional analysis with proper orthogonal decomposition was performed to enhance the understanding of complex flow structures downstream of the expansion. Finally, an overall correlation expression for the reattachment length was obtained for 500 ≤ Re ≤15 000 and 0.2 ≤ TI (%) ≤ 20. For a given turbulence intensity, the reattachment length can be expressed for laminar and turbulent regions as a function of the Reynolds number. The reattachment length in the transition region can be expressed as a fractional average of reattachment lengths for laminar and turbulent flows.

99 GENERAL AND MISCELLANEOUS↗

HERO WEC V1.0 2024 - WEC-Sim Detailed Simulation Runs and Summary Data

This dataset includes results from simulations of NREL's hydraulic and electric reverse osmosis wave energy converter (HEREO WEC). Simulation runs include 135 wave cases that were based on the updated WEC-Sim model, which is linked below. The data represented in this repository is based on an updated WEC-Sim model using laboratory data to tune and refine the original WEC-Sim model for the V1.0 HERO WEC. The 135 wave cases represent waves with the following wave height and wave period ranges: - Significant Wave Height: 0.25 - 3.75m in 0.25m increments - Wave Period: 5 - 13 sec in 1 sec increments Each run was simulated using a Pierson-Moskowitz irregular wave spectrum with a 100 second ramp time, a total simulation time of 3,100 seconds, and a simulation time-step of 0.005s. A reference table has been included to map each multi condition run (MCR) case with each wave condition. Summary data set includes a spreadsheet and image files with matrices that are associated with data from simulation runs. All matrices cover the same significant wave height and wave periods from the simulation runs, in the same increments. The following matrices are included: - Power Abs: The average absorbed power from the WEC (calculated from anchor reaction force and heave velocity) - Power Hyd: The average hydraulic power output at pump (calculated from pump output flow and pressure) - Power - Hyd ROi: The average hydraulic power measured at the RO system inlet (calculated from RO system pressure and flow (pre-accumulator)) - Flow - Pump out: The average flowrate measured at the pump outlet - Flow - Perm: The average permeate (clean water) production - Flow - RO (pre): The average flowrate measured at the inlet of the RO system before the accumulators - Flow - RO (post): The average flowrate measured after the accumulator bank in the RO system - Pressure - RO: The average pressure measured at the inlet of the RO system This data set has been developed by the National Renewable Energy Laboratory, operated by the Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

Nek5000 developments in support of industry and the NRC

This year, the Nuclear Energy Advanced Modeling Simulation program (NEAMS) thermal-hydraulics verification and validation (V&V) work has focused in three areas of Nek5000 V&V-driven development. First, in a close collaborative effort with the U. S. Nuclear Regulatory Commission (NRC) staff, we have continued V&V efforts for the HYMERES-2 project using the OECD/NEA sponsored testing in the PSI PANDA facility. This year’s focus of ANL-NRC collaboration involves Nek5000 setups and validation for a range of problems relevant to and including the HYMERES-2 benchmark from PSI. The primary outcome of this year efforts is a more efficient geometry and inlet modeling simplification after a careful sensitivity study of the inlet profiles and pipe geometries. The resulting modeling choice of a short recycling/fully-developed turbulent inlet is within the experimental uncertainty estimate. This finding simplifies the next step of the cross-V&V HYMERES-2 project. In addition, the ANL team continue to provide assistance to the NRC staff in the form of Nek5000 application support in general and on the use of the HPC platforms of ALCF and INL in particular. This supports the NRC’s assessment of Nek5000 for use with the NRC Blue CRAB code suite. Second, we have implemented and tested more robust model of URANS, namely the k – τ model, a variant of the k-ω model, along with other improvements to RANS Nek5000 modeling in general. Because of its demonstrated robustness and stability, the k – τ model is the only RANS model that has been implemented in the new GPU version of the Nek5000 code, nekRS. Lastly, we report the initial implementation of Jacobian-free Newton Krylov approach to the direct Newton method for steady fluid solvers aimed at acceleration of RANS modeling and at IC improvement for LES campaigns. Also leveraging the Exascale Computing Project (ECP) ANL/CEED & SMR team’s software development effort to support NEAMS problems at large scale of the advanced computing architectures, NekRS, a GPU variant of Nek5000, built on top of kernels from libParanumal using OCCA for portability, has been successfully run on the full system of Summit (4608 nodes, 27648 GPUs).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Emissions mitigation technology for advanced water-lean solvent-based CO 2 capture processes

This technical final report submitted to DOE/NETL presents all the research activities performed during the entirety of DE-FE0031660 project-Emissions Mitigation Technology for Advanced Water-Lean Solvent-Based CO 2 Capture Processes which spans from October 2018 through March 2022. RTI International has been conducting studies from fundamental and operational aspects to reduce the overall amine emissions from the advanced Water-Lean Solvent (WLS) systems, specifically RTI’s Non-Aqueous Solvent (NAS). This technical final report will highlight the key findings from project which align closely to the project objectives which are: Identify the contribution of vapor loss, entrainment, and aerosols to the overall emissions of water-lean systems; Determine the significance of CO 2 capture system operating parameters to the amine emissions; Develop an emissions model based on critical operating parameters; Evaluate the effectiveness of emissions mitigation devices to reduce the amine emissions to <1 ppm under flue coal-fired flue gas; and, Determine the contribution of the ECTs to the overall CO 2 capture cost. The following are the key findings based on numerous tests using both lab-scale setups and parametric testing performed at RTI’s Bench-scale Gas Absorption System (BsGAS). During the BP1, the aerosol generation system and monitoring equipment were installed at BsGAS to produce and determine the aerosol characteristics during the NAS CO 2 capture process. The aerosol produced by this setup produced aerosols with the peak diameter and concentration of 50 micron and 1.2E10 7 cm -3 , respectively. These particle sizes and concentrations are matched to those observed in the actual coal-fired power plant flue gases and expected to be found at the absorber inlet of the CO 2 capture system. Over 1,300 hours of parametric testing have been conducted to evaluate the impact of the aerosols and operating conditions during the CO 2 capture with NAS on the overall amine emissions in the treated flue gas. At the worse condition tested, the presence of the aerosols in the flue gas could increase the overall emissions by 10X compared to the baseline emissions from NAS’s vapor pressure. CO 2 capture rate was found to be a main factor impacting the overall emissions as well as aerosol size and concentrations in the absorber off-gas. The higher CO 2 capture rate, the higher amine emissions in the treated gas. The temperature difference between the temperature bulge seen in the absorber and the water wash temperature also impacts the particle growth where the larger the temperature difference, the more amine emissions from aerosols in the treated gas. The majority of the aerosols did not grow substantially in the system, and the particle concentrations remained nearly constant between the absorber inlet and wash outlet. Only a small portion of the particles were found to grow significantly. The high efficiency demister with mesh size of 5-10 micron can be installed to remove a portion of the aerosols from the gas stream leaving the water wash. Overall, these results from parametric testing have established the emission baseline and validate our assumption on the need of emission control technologies (ECT) in order to minimize the emissions from the baseline NAS CO 2 capture process. Over 2,000 of BsGAS operating hours was used to investigate a handful of process improvements which led to a selection of the vital few changes that effectively control the amine emissions. These process improvements are lime-coated-filters for absorber gas inlet, advanced demister at the top of the absorber, a second water wash with amine recovery unit were designed, installed, and tested at BsGAS at the end of BP1. The result showed that the NAS CO 2 capture process with these additional emission control devices could lower the amine emission in the treated gas to about 1 ppm using a simulated coal-fire flue gas stream. The main contributor in lowering the amine emission came from the second water wash with amine recovery unit where the amine concentration in the scrubbing water was kept below 2 wt% through a continuous amine removal via an adsorbent bed, resulting in a low amine vapor pressure. The adsorbent bed was regenerated via a direct steam regeneration and the recover amine was returned to the absorber to minimize wastewater and makeup amine. A flue gas generation system was designed and installed during the first half of BP2 to support the emission testing using a real coal-derived flue gas. The system is capable of generating both coal- and natural gas- derived flue gases with the composition of the gaseous species highly resemble to that of the power plant flue gases. The particulates detected in the coal-derived flue gas showed the mean diameter of 1 micron. The CO 2 capture operating was then proceed using the real coal-derived flue gas where the amine emission was controlled to be about 0-3 ppm for the total run time of about 200 hours. Similar testing was conducted with natural gas-derived flue gas and the result showed a highly amine emission of 30 ppm under the total run time of 200 hours. The Principal Component Analysis (PCA) and the Partial Least Squares Projection to Latent Structures (PLS) techniques were applied to the parametric testing data to derive a multivariate statistical model. The model was validated and trained with half of the data collected, and the predictive ability of the model was evaluated using the remaining half of the data. The resulting empirical model was capable of predicting the overall emissions from the NAS process without the ECTs with ±15% accuracy (average absolute deviation, AAD) in BP1. As more emission data were obtained under the real coal-flue gas in the BP2, the model incorporated these new set of data to reflect the final process configuration, operating parameters, and amine emission. This results in the updated empirical model predicting the amine emission from the NAS CO 2 capture process with 84% goodness-of-fit (R 2 ), 85% predictability (Q 2 ), and 15% AAD. The study evaluates the use of RTI’s Non-Aqueous Solvent technology for 90% CO 2 capture from a net 650 MWe pulverized coal power plant, downstream of the flue-gas desulfurization unit. The captured CO 2 has a purity of > 95% CO 2 , and is dried, compressed to 15.3 MPa (2,215 psia), ready for sequestration. The analysis uses Case B12B from the DOE Baseline study on Bituminous Coal, Revision 4 where the Cansolv CO 2 capture plant is replaced by the RTI CO 2 Capture plant. The CO 2 capture plant has been sized to capture >90% CO 2 from flue gas derived from a net 650 MWe supercritical pulverized coal power plant. The CO 2 capture plant is equipped with emission control technologies that limits the amine emissions to < 1 ppm. Two different cases were evaluated for the technoeconomic study. The key difference between the two cases is the regenerator pressure. In Case 1, the regenerator operates at 0.195 MPa (28.3 psia), whereas in Case 2, the regenerator pressure is 0.44 MPa (64 psia) thus removing the need for the first stage of compression of the eight-stage compression train. Results from the TEA are compared against the DOE reference cases for SCPC plant with and without CO 2 Capture (Case B12A and Case B12B of the DOE Baseline study, respectively). Case 2 with CO 2 regeneration at higher pressure results in the lower cost of CO 2 capture. The total capital cost of the capture process has been estimated using 2018 dollars in Aspen Process Economic Analyzer and was estimated to be $579 MM. The capture plant operation leads to a total parasitic power loss rate of 96 MWe, resulting in a decrease in pulverized coal power plant efficiency of 7.8% points. The resulting cost of electric power increases from 64.4 mills/kWh, for no capture, to 97.5 mills/kWh, with 90% capture, an increase of 51% in the COE. The cost of capturing 90% CO 2 was estimated to be $38.2/tonne-CO 2 , and meets the DOE target of $40/t-CO 2 . Emission control technologies (ECT) investigated in this project includes a second water wash with use of activated carbon beds for removal of amine from the wash water prior to recirculation in the water wash. These ECT allow operation of the CO 2 capture plant with < 1 ppm amine emissions with the treated flue gas and contributes to $2.4/t-CO 2 captured. Amine emissions derived from thermal and oxidative degradations were investigated under this project along with the emissions derived from aerosols for the NAS system. The thermally degraded of the lean NAS showed less than 4% decreased of the original total amine content in the NAS at 150 °C while the result obtained at 120 °C showed no drop in total amine content, suggesting that thermal degradation of the NAS is minimal. These results also suggested that the thermally degraded species are not likely formed and contributed to the emissions due to the low regeneration temperature of the NAS at 90-105 °C. The oxidative degradation, on the other hand, could become problematic as some of these oxidative degraded species were observed during the NAS-5 testing at National Carbon Capture Center (NCCC) and SINTEF in our previous project. The rapid screening of selected inhibitors suggested that oxidative degradation of NAS can be suppressed using thiol containing compounds in amounts of at least 1 mol%. The detailed mechanistic degradation pathway was conceived for a specific amine used in NAS formulation during BP2. he reduction of the nitrosamines caused by the NO x present in the flue gas was also examined. The study suggested that the thermo-chemical treatment of the NAS solvent would be a more effective and economically viable compared to removing NO x at the DCC.

01 COAL, LIGNITE, AND PEAT↗

Three-Dimensional CFD Analysis of Construction Design Alternatives for an ERDC Coastal and Hydraulics Laboratory Flow Accelerator

The U.S. Army Engineer Research and Development Center, ERDC, Coastal and Hydraulics Laboratory in Vicksburg Mississippi is planning to build a large flume with a 10-foot-wide flow channel. Three-dimensional Computational Fluid Dynamics (CFD) analysis was used in the design of the flume entry and flow accelerator sections that feed into the 10-foot-wide channel. The design is based on the plans of the existing fiberglass flume inlet at the Turner-Fairbank Highway Research Center (TFHRC) J. Sterling Jones Hydraulics Research Laboratory in McLean Virginia. The TFHRC flume inlet feeds water to a 6-foot-wide flume channel, and therefore a scale up factor of 10/6 in the width of the inlet section of the TFHRC flume would meet the width requirement of the ERDC flume channel. The CFD analysis was performed using STAR-CCM+ commercial CFD software. Additional analysis was done with the open-source CFD software, OpenFOAM, to cross-check the analysis of one of the cases with a code-to-code comparison.

42 ENGINEERING↗

Mechanically-, Thermally, and Chemically-Robust High-Temperature Ceramic Composites

In an effort to lower the levelized cost of electricity generated by Concentrated Solar Power (CSP) plants, the heat-to-electricity conversion efficiency may be increased by operating such plants with higher turbine inlet temperatures using closed Brayton cycles with high-pressure, supercritical carbon dioxide (sCO 2 ) as the working fluid. For example, if the turbine inlet temperature is raised to ≥750°C, in combination with sCO2 closed Brayton cycles, the relative heat-to-electricity efficiency may be raised by more than 20% (compared to subcritical steam Rankine cycles operating with turbine inlet temperatures ≤550°C). The associated reduction in the cost of dispatchable electricity from such CSP plants (utilizing high-temperature thermal energy storage) would be an important breakthrough on the path towards direct competition with fossil-fuel-based plants. A key barrier to achieve such high-temperature efficient operation has been the limited thermomechanical performance of metal alloys used in compact, primary printed circuit- type heat exchangers (PCHEXs) for heat transfer to high-pressure sCO 2 . The maximum allowed stresses for the use of conventional stainless steels and nickel-based superalloys at high sCO 2 pressures (≥20 MPa) decline rapidly at temperatures ≥550°C. This project has been focused on demonstrating the desired high-temperature properties and attractive manufacturing characteristics of mechanically-, thermally-, and chemically-robust ceramic/metal composites (cermets), in order to allow for the use of such composites in primary PCHEXs for heat transfer to sCO 2 at ≥750°C and ≥20 MPa in CSP plants. Prior work with high-temperature, co-continuous carbide/refractory metal cermets, such as ZrC/W composites, has already demonstrated: i) the attractive combination of high-temperature properties exhibited by such materials (e.g., high values of stiffness, failure strength, and thermal conductivity at 800°C), and ii) cost-effective processes for manufacturing PCHEX plates comprised of such cermets with tailorable channel patterns. However, ZrC/W cermets were not found to be inherently corrosion resistant in sCO 2 at 750°C and 20 MPa. While the application of a Cu coating to ZrC/W surfaces, along with a modest addition (50 ppm) of CO to CO 2 , rendered such composites resistant to corrosion for 1000 h in such sCO 2 -based fluids at 750°C, such additional steps would increase the design complexity of such cermet-based components. An alternative approach (the focus of this project) is to develop mechanically-robust, cost- effective cermets that are inherently resistant to high-temperature oxidation in air and CO 2 . The overall goals of this project have been to demonstrate: i) the oxidation resistance of at least one cermet at 750°C in air and in CO 2 (i.e., with a projected annual corrosion ≤30 μm), ii) the mechanically robust nature of at least one cermet at 750°C (i.e., with an average failure strength ≥200 MPa), and iii) that the selected cermet can be manufactured via low-cost forming techniques.

14 SOLAR ENERGY↗