Search NASA⌕ Search

SEARCH · Search NASA

Results for “inline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A round-robin approach provides a detailed assessment of biomolecular small-angle scattering data reproducibility and yields consensus curves for benchmarking

Through an expansive international effort that involved data collection on 12 small-angle X-ray scattering (SAXS) and four small-angle neutron scattering (SANS) instruments, 171 SAXS and 76 SANS measurements for five proteins (ribonuclease A, lysozyme, xylanase, urate oxidase and xylose isomerase) were acquired. From these data, the solvent-subtracted protein scattering profiles were shown to be reproducible, with the caveat that an additive constant adjustment was required to account for small errors in solvent subtraction. Further, the major features of the obtained consensus SAXS data over the q measurement range 0–1 Å −1 are consistent with theoretical prediction. The inherently lower statistical precision for SANS limited the reliably measured q -range to <0.5 Å −1 , but within the limits of experimental uncertainties the major features of the consensus SANS data were also consistent with prediction for all five proteins measured in H 2 O and in D 2 O. Thus, a foundation set of consensus SAS profiles has been obtained for benchmarking scattering-profile prediction from atomic coordinates. Additionally, two sets of SAXS data measured at different facilities to q > 2.2 Å −1 showed good mutual agreement, affirming that this region has interpretable features for structural modelling. SAS measurements with inline size-exclusion chromatography (SEC) proved to be generally superior for eliminating sample heterogeneity, but with unavoidable sample dilution during column elution, while batch SAS data collected at higher concentrations and for longer times provided superior statistical precision. Careful merging of data measured using inline SEC and batch modes, or low- and high-concentration data from batch measurements, was successful in eliminating small amounts of aggregate or interparticle interference from the scattering while providing improved statistical precision overall for the benchmarking data set.

59 BASIC BIOLOGICAL SCIENCES↗

Toward High-Throughput Deposition of III-V Materials and Devices Using Halide Vapor Phase Epitaxy: Preprint

III-V devices are used in countless applications due to their excellent physical properties. They could become more prevalent, especially in area-intensive applications such as solar power, if they can achieve significant cost decreases through increasing scale. The development of high-throughput growth systems can help to achieve this scale, leading to the use of III-V devices in areas where they are not currently economically feasible. Here, we describe a pilot production, pseudo inline HVPE reactor with the potential to greatly increase the throughput of III-V devices. We show computational modeling results that both informed system design and the understanding of the impact of different process parameters on the deposition. We show the throughput possibilities of this reactor with an example solar cell device design but note that this system is agnostic to the device structure and can be used to increase the throughput of lasers, LEDs, transistors, and more III-V devices.

high throughput↗

SU-E-T-119: Dosimetric and Mechanical Characteristics of Elekta Infinity LINAC with Agility MLC

Purpose: Elekta Infinity is the one of the latest generation LINAC with unique features. Two Infinity LINACs are recently commissioned at our institution. The dosimetric and mechanical characteristics of the machines are presented. Methods: Both Infinity LINACs with Agility MLC (160 leaves with 0.5 cm leaf width) are configured with five electron energies (6, 9, 12, 15, and 18 MeV) and two photon energies (6 and 15 MV). One machine has additional photon energy (10 MV). The commissioning was performed by following the manufacturer's specifications and AAPM TG recommendations. Beam data of both electron and photon beams are measured with scanning ion chambers and linear diode array. Machines are adjusted to have the dosimetrically equivalent characteristics. Results: The commissioning of mechanical and imaging system meets the tolerances by TG recommendations. The PDD{sub 10} of various field sizes for 6 and 15 MV shows < 0.5% difference between two machines. For each electron beams, R{sub 80} matches with < 0.4 mm difference. The symmetry and flatness agree within 0.8% and 0.9% differences for photon beams, respectively. For electron beams, the differences of the symmetry and flatness are within 1.2% and 0.8%, respectively. The mean inline penumbras for 6, 10, and 15 MV are respectively 5.1±0.24, 5.6±0.07, and 5.9±0.10 mm for 10x10 cm at 10 cm depth. The crossline penumbras are larger than inline penumbras by 2.2, 1.4, and 1.0 mm, respectively. The MLC transmission factor with interleaf leakage is 0.5 % for all photon energies. Conclusion: The dosimetric and mechanical characteristics of two Infinity LINACs show good agreements between them. Although the Elekta Infinity has been used in many institutions, the detailed characteristics of the machine have not been reported. This study provides invaluable information to understand the Infinity LINAC and to compare the quality of commissioning data for other LINACs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shear-wave anisotropy reveals pore fluid pressure–induced seismicity in the U.S. midcontinent

Seismicity in the U.S. midcontinent has increased by orders of magnitude over the past decade. Spatiotemporal correlations of seismicity to wastewater injection operations have suggested that injection-related pore fluid pressure increases are inducing the earthquakes. We present direct evidence linking earthquake occurrence to pore pressure increase in the U.S. midcontinent through time-lapse shear-wave (S-wave) anisotropy analysis. Since the onset of the observation period in 2010, the orientation of the fast S-wave polarization has flipped from inline with the maximum horizontal stress to inline with the minimum horizontal stress, a change known to be associated with critical pore pressure buildup. The time delay between fast and slow S-wave arrivals exhibits increased variance through time, which is common in critical pore fluid settings. Near-basement borehole fluid pressure measurements indicate pore pressure increase in the region over the earthquake monitoring period.

58 GEOSCIENCES↗

Patterning approach for detecting defect in device manufacturing

Compact handheld devices which were a dream in the past are now a reality; this has been enabled by miniaturization of circuit architectures including power devices. Scaling down of the design feature sizes does come with a price with an increase in systematic defects during chip manufacturing. There are generally two methods of inline defect detection adopted to monitor the semiconductor device fabrication—optical inspection and electron beam inspection. The optical inspection uses ultra-violet and deep ultra-violet (UV/DUV) light to find patterning defects on the wafer. While the electron-beam inspection uses electron charge and discharge measurement to find electrical connection defects, both are a costly procedure in terms of resources and time. The physical limit of feature resolution of the optical source is now making the defect inspection job difficult in miniaturized application specific integrated circuit (ASIC). This study is designed to test the patterning optimization approach on both inspection platforms. Using hotspot analysis weak locations are identified in the full chip design, and then they are verified in the inline wafer inspection. The criterion for hot-spot determination is also discussed in this paper.

36 MATERIALS SCIENCE↗

DEDUPKV: A Space-Efficient and High-Performance Key-Value Store via Fine-Grained Deduplication

Log-Structured Merge Tree (LSM-tree) based key-value stores excel in write-intensive environments but suffer from data duplication, consuming up to 49% of storage space in LSM-tree-based key-value store deployments. Traditional solutions like compression and coarse-grained file system-level deduplication introduce overhead or have limited effectiveness. In this study, we propose DedupKV, a fine-grained deduplication framework tailored for LSM-tree, maximizing data reduction efficiency while minimizing write stalls and read overheads. DedupKV features three key innovations: (1) FLUSH-integrated inline deduplication, which removes duplicates during memory-to-storage writes; (2) WAL file-based offline deduplication, repurposing write-ahead logs to avoid double writes; and (3) elastic execution, dynamically balancing inline and offline deduplication based on memory pressure and workload intensity. Additionally, dynamic granularity management reduces deduplication metadata overhead. We implemented these four ideas in RocksDB for the first time and conducted experiments in a Linux environment. Our evaluation shows that WAL file-based offline deduplication and DedupKV outperform BlobDB by 33% and 23%, respectively, in write-heavy workloads, while reducing write amplification by 1.2 ×, 2 ×, and 1.6 × for real KV datasets.

Jamil, Safdar [Sogang University]↗

Modeling and control of fuel distribution in a dual-fuel internal combustion engine leveraging late intake valve closings

In internal combustion engines, cycle-to-cycle and cylinder-to-cylinder variations of the combustion process have been shown to negatively impact the fuel efficiency of the engine and lead to higher exhaust emissions. The combustion variations are generally tied to differences in the composition and condition of the trapped mass throughout each cycle and across individual cylinders. Thus, advanced engines featuring exhaust gas recirculation, flexible valve actuation systems, advanced fueling strategies, and turbocharging systems are prone to exhibit higher variations in the combustion process. In this study, the cylinder-to-cylinder variations of the combustion process in a dual-fuel internal combustion engine leveraging late intake valve closing are investigated and a model to predict and address one of the root causes for these variations across cylinders is developed. The study is conducted on an inline six-cylinder heavy-duty dual-fuel engine equipped with exhaust gas recirculation, a variable geometry turbocharger, and a fully flexible variable intake valve actuation system. The engine is operated with late intake valve closure timings in a dual-fuel combustion mode in which a high reactivity fuel is directly injected into the cylinders and a low reactivity fuel is port injected into the cylinders. The cylinder-to-cylinder variations observed in the study have been associated with the maldistribution of the port-injected fuel, which is exacerbated at late intake valve timings. The resulting difference in indicated mean effective pressure between the cylinders ranges from 9% at an intake valve closing of 570° after top dead center to 38% at an intake valve closing of 620° after top dead center and indicates an increasingly uneven fuel distribution. The study leverages both experimental and simulation studies to investigate the distribution of the port-injected fuel and its impact on cylinder-to-cylinder variation. The effects of intake valve closing as well as the impact of intake runner length on fuel distribution were quantitatively analyzed, and a model was developed that can be used to accurately predict the fuel distribution of the port-injected fuel at different operating conditions with an average estimation error of 1.5% in cylinder-specific fuel flow. A model-based control strategy is implemented to adjust the fueling at each port and shown to significantly reduce the cylinder-to-cylinder variations in fuel distribution.

Kassa, Mateos↗

Focus enhancement in long schlieren imaging systems using corrector lenses

Long schlieren imaging systems, where the parallel light test section is longer than the focal length of the focusing schlieren optics, have a limited region in the test section in which any occluding object, such as a wind tunnel model, is in focus in the schlieren image. Corrector lenses are introduced here to alter the location in the test section where image focus is achieved. Corrector lenses with focal lengths varying from −1000 to −100mm were studied. Lens-type inline and z -type mirror schlieren systems were experimentally tested with multiple collecting optic focal lengths to characterize the changes in focal position. An automated image processing method was used to determine the plane of best focus from image sequences. The introduction of the corrector lens was observed to move the location of best focus within the schlieren system test section while also causing a decrease in the focal sharpness of the images and altering the magnification. The thin lens equation was found to provide a good estimate of the focal location change in the schlieren imaging systems with the addition of the corrector lens.

Torres, Sivana M.↗

Soladigm DOE Final Scientific/Technical Report

Soladigm's research has produced a fundamental improvement in the technology for dynamic windows by successfully transitioning a low-cost, high-performance dynamic glass fabrication process from a simple 2" research prototype into a full-scale manufacturing environment capable of producing commercial dynamic insulated glass units (IGUs), and developing and optimizing the production process to meet all specifications for mass commercial production. The technology developed under this project is a revolutionary process for fabricating electrochromic glass that today exceeds DOE's 2020 performance and reliability targets at a compelling consumer price point. Before this project, we had demonstrated 2" prototypes using our deposition process that met these performance targets. The goal of this project was to prove that we could transition this lab-scale process to a scalable, "inline" manufacturing process, leveraging existing manufacturing tools capable of achieving a commercially attractive pricepoint in the near-term. Under this project we demonstrated the technical effectiveness of our manufacturing process by achieving or exceeding all of our technical and performance targets for inline fabrication of electrochromic IGUs. These performance specifications exceed DOE's 2020 performance and reliability targets. We also demonstrated the economic feasibility of our manufacturing process by reaching an initial production process that will achieve our target costs, which are compatible with mass adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lucid Energy Inc. In-Conduit Hydropower. Final Research Performance Progress Report

With the goal of commercializing the LucidPipe Power System (LucidPipe) in late 2012, Lucid Energy performed much research and testing of turbines, particularly focusing on understanding and mitigating cavitation and improving performance, as well as to improve data acquisition, monitoring and control of the LucidPipe system. Lucid Energy developed a 24” version of the LucidPipe to complement the 42” system, which had been the primary focus up to that point. Lucid Energy replaced the prototype system in Riverside, California with a new system that included a bypass pipe in order to provide year-round access to the turbine, as well as replacing the temporary “trench box” in which it formerly resided with a poured concrete vault. This system was commissioned in January 2012 and has been operational since that time. This new system was the first LucidPipe version to utilize fiberglass composite blades with an improved blade profile and bolted end connections. Using the accelerated test methodology developed by the Fracture Mechanics and Materials Durability Laboratory at the University of Illinois, Lucid Energy evaluated various composite blade materials and coatings in order to select a material with optimum resistance to cavitation. Various other components have been designed, and Lucid Energy has worked with several suppliers to improve the capabilities of purchased components such as seals, bearings and mechanical brakes. These improvements were primarily to increase the robustness of the LucidPipe systems for use in commercial applications. Lucid Energy performed testing on series inline turbines at the Utah Water Research Laboratory Page 36 of 44 in order to evaluate the performance implications of installing LucidPipe systems consisting of multiple inline turbines in commercial applications. Lucid Energy is currently planning to install a commercial four-turbine, 42” system in Portland, Oregon in the first quarter of 2013 and a three-turbine 24” system at San Antonio Water System in San Antonio, Texas in the second quarter of 2013.

13 HYDRO ENERGY↗

Two-Way Integration of WRF and CCSM for Regional Climate Simulations

Under the support of the DOE award DE-SC0004670, we have successfully developed an integrated climate modeling system by nesting Weather Research and Forecasting (WRF) model within the Community Climate System Model (CCSM) and the ensuing new generation Community Earth System Model (CESM). The integrated WRF/CESM system is intended as one method of global climate modeling with regional simulation capabilities. It allows interactive dynamical regional downscaling in the computational flow of present or future global climate simulations. This capability substantially simplifies the process of dynamical downscaling by avoiding massive intermediate model outputs at high frequency that are typically required for offline regional downscaling. The inline coupling also has the advantage of higher temporal resolution for the interaction between regional and global model components. With the aid of the inline coupling, a capability has also been developed to ingest other global climate simulations (by CESM or other models), which otherwise may not have necessary intermediate outputs for regional downscaling, to realize their embedded regional details. It is accomplished by relaxing the global atmospheric state of the integrated model to that of the source simulations with an appropriate time scale. This capability has the potential to open a new venue for ensemble regional climate simulations using a single modeling system. Furthermore, this new modeling system provides an effective modeling framework for the studies of physical and dynamical feedbacks of regional weather phenomena to the large scale circulation. The projected uses of this capability include the research of up-scaling effect of regional weather system, and its use as an alternative physical representation of sub-scale processes in coarser-resolution climate models.

54 ENVIRONMENTAL SCIENCES↗

Metal Bellows Valve Reliability Testing

Swagelok B ® series metal bellows-sealed valves were tested for their cycle performance longevity to evaluate their use in tritium service. The valves selected differed in the size of their pneumatic actuator and the stem tip material. Valves tested had one of three actuator sizes (1C, 3C, or 5C) and one of two stem tip materials: a cobalt-based metal, Stellite™, and a polyimide material, Vespel ® . An automated valve manifold was constructed, allowing for the simultaneous cycling of a total of 10 valves. Automation controls allowed for user inputs, controlling the number of valve cycles per test and the number of tests per experiment. Valves installed on the valve testing manifold to be cycled following a valve frequency test plan. After a defined number cycles, the valves would undergo leak testing using an inline leak detector. The inline helium leak detector provided qualitative detection of any failing or failed valves. If a valve had failed, a leak rate greater than at 1.0 x 10 -7 std cc He/sec, the valve would be removed from the manifold and quantitative leak rate measurements made. After specific cycling milestones were reached, quantitative valve leak rate measurements were performed to assess the adequacy of the qualitative measurement method. Valve evaluation began with initial leak tests: valve inlet/outlet seat rates and total body leak rate. The as received 1C valves, with PTFE stem tips, passed initial leak tests; however, stem tips replacements with either metal or polyimide stem tips essentially created valves which failed subsequent leak tests and were not subject to valve cycling. The 3C actuated valves had been cycled 150,000 times, resulting in 60% of the Stellite™ and Vespel ® tipped valves still passing the leak rate criteria. Failure analysis on the other 40% has yet to be conducted. Eight of the 5C valves had reached 150,000 cycles with 80% of the valves passing the leak rate criteria: two Vespel ® tipped 5C valves failed leak rate testing after 120,000 cycles.

36 MATERIALS SCIENCE↗

CPAP Ventilators Needed for Rapid Response to COVID-19 by Modification of CPAP Equipment

Early on in the COVID-19 pandemic, potential ventilator shortages were a critical issue identified by national health care providers. Capacity modeling at the time suggested patient demand may exceed ventilator supply. Thus, the challenge became finding an urgent interim solution to meet health care needs. Our initial hypothesis was that CPAP technology could be modified to provide similar functionality to a ventilator, relieving demand and allowing physicians to decide which patients need high end machines, ultimately saving lives. In conjunction with medical experts and pulmonologists, we were able to identify three key thrusts associated with this research problem: (1) modification of CPAP technology to allow for 02 input that would be capable of providing ventilation; (2) development of an alarming function that would provide real-time audible alarms to alert medical personnel to critical conditions, which would be used inline with CPAP technology; and (3) a method of sterilizing expiratory air from such a system in order to protect medical personnel from biohazard, since CPAPs vent to the atmosphere. We were unable to realize results for thrust 1 (CPAP modification for 02); we identified potential safety issues associated with utilizing medical grade oxygen with a common CPAP device. In order to characterize and mitigate these issues, we would need to partner closely with a device manufacturer; such a partnership could not be achieved in the timeframe needed for this rapid response work. However, we determined that some medical grade BiPAP devices do not need this modification and that the significant progress on thrusts 2 and 3 would be sufficient to buy down risk of a massive ventilator shortage. Our team built a prototype alarm system that can be utilized with any assistive respiratory device to alert on all key conditions identified by medical personnel (high pressure, low pressure, apnea, loss of power, low battery). Finally, our team made significant progress in the rapid prototyping and demonstration of an inline UV air purifier device. The device is cost efficient and can be manufactured at scale with both commercially available and additively manufactured parts. Initial tests with SARS-CoV-2 analog bacteriophage MS2 show 99% efficacy at reducing bioburden. Following a successful demonstration of the prototype device with medical personnel, we were able to obtain follow-on (non-LDRD) funding to provide additional device characterization, validation, and production in order to respond to an immediate regional need.

42 ENGINEERING↗

Integrating BISON into VERA-CS and Fuel Temperature Calculations

Approaches to integrating BISON into VERA-CS were identified as: 1) Coupled TIAMAT calculations in which BISON is solved simultaneously with MPACT and CTF via direct coupling, 2) Inline TIAMAT in which BISON calculations are performed as part of the same VERA-CS calculation sequence as coupled MPACT-CTF calculations but there is no feedback from the BISON calculations into the MPACT-CTF calculations, and 3) Stand-alone (“Offline”) BISON calculations in which desired data is parsed from the results of an already-completed MPACT-CTF VERA-CS analysis and BISON calculations are performed afterwards. The current maximum capabilities of these approaches in the latest VERA build are a single ramp-to-power for Coupled TIAMAT, analysis of two subsequent operating cycles for a single pin in Inline TIAMAT, and BISON analysis for every fuel pin in a PWR quarter-core for multiple operating cycles in Stand-alone BISON.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of Intake Air Filter Condition on Light-Duty Gasoline Vehicles

Proper maintenance can help vehicles perform as designed, positively affecting fuel economy, emissions, and the overall drivability. This effort investigates the effect of one maintenance factor, intake air filter replacement, with primary focus on vehicle fuel economy, but also examining emissions and performance. Older studies, dealing with carbureted gasoline vehicles, have indicated that replacing a clogged or dirty air filter can improve vehicle fuel economy and conversely that a dirty air filter can be significantly detrimental to fuel economy. The effect of clogged air filters on the fuel economy, acceleration and emissions of five gasoline fueled vehicles is examined. Four of these were modern vehicles, featuring closed-loop control and ranging in model year from 2003 to 2007. Three vehicles were powered by naturally aspirated, port fuel injection (PFI) engines of differing size and cylinder configuration: an inline 4, a V6 and a V8. A turbocharged inline 4-cylinder gasoline direct injection (GDI) engine powered vehicle was the fourth modern gasoline vehicle tested. A vintage 1972 vehicle equipped with a carburetor (open-loop control) was also examined. Results reveal insignificant fuel economy and emissions sensitivity of modern vehicles to air filter condition, but measureable effects on the 1972 vehicle. All vehicles experienced a measured acceleration performance penalty with clogged intake air filters.

air filters↗

Feedforward Control of Fuel Distribution on Advanced Dual-Fuel Engines with Varying Intake Valve Closing Timings

This study examines the dynamics and control of an engine operated with late intake valve closure (LIVC) timings in a dual-fuel combustion mode. The engine features a fuel delivery system in which diesel is direct-injected and natural gas is port-injected. Despite the benefits of LIVC and dual-fuel strategy, combining these two techniques resulted in efficiency losses due to the variability of the combustion process across cylinders. The difference in power production across cylinders ranges from 9% at an IVC of 570°ATDC* to 38% at an IVC of 620 °ATDC and indicates an increasingly uneven fuel distribution as the intake valve remains open longer in the compression stroke. This paper describes an approach for controlling the amount of fuel injected into each cylinders’ port of an inline six- cylinder heavy-duty dual-fuel engine to minimize the variations in fuel distribution across cylinder. Since measuring the actual fuel reaching each cylinder is not a practical option on stock engines, this study aimed to produce a feedforward control technique. Using a model developed on an engine simulation software, the optimal fuel injection amounts at each cylinder port across 125 operating conditions (consisting of sweeps of five engine speeds, five engine loads, and five IVC timings) were determined by using PI controllers that adjust the amount of fuel injected at each port based on the amount of fuel reaching the cylinders. The results from the PI controller were expressed as a function of the operating condition (engine speed, engine load, and IVC timing); and consequently, could be reproduced without relying on a measurement of the amount of fuel reaching each cylinder. The feedforward control strategy, unlike the PI controller, is easily implementable on a stock engine and significantly reduces the variations in fuel distribution across cylinders.

Kassa, Mateos↗

Thermal analysis of a high energy propulsion system /hydrazine and liquid fluorine/ for a rover class Mars Orbiter

Maintaining cryogenic fluorine at a -189 C during the interplanetary cruise period to Mars is a major thermal problem. At this low temperature the heat rejection by radiation is severely limited and the allowable thermal load to the fluorine tank is less than approximately 8 watts. Previous studies generally constrain the spacecraft to an inline tank configuration which tends to maximize the fluorine tank's view and heat rejection to space. With the Inertial Upper Stage, sufficient stack height may not be available on the Shuttle for an inline tank configuration. Therefore, this study addresses the more thermally constraining side by side tank configuration.

Stultz, J. W.↗

Aerodynamic characteristics at low Reynolds numbers of several heat-exchanger configurations for wind-tunnel use

In response to design requirements of the National Transonic Facility, aerodynamic tests were conducted to determine the pressure-drop, flow-uniformity, and turbulence characteristics of various heat-exchanger configurations as a function of Reynolds number. Data were obtained in air with an indraft flow apparatus operated at ambient temperature and pressure. The unit Reynolds number of the tests varied from about 0.06 x 10 to 6th power to about 1.3 x 10 to 6th power per meter. The test models were designed to represent segments of full-scale tube bundles and included bundles of round tubes with plate fins in both staggered and inline tube arrays, round tubes with spiral fins, elliptical tubes with plate fins, and an inline grouping of tubes with segmented fins.

Johnson, W. G., Jr.↗