Search NASA⌕ Search

SEARCH · Search NASA

Results for “insertion device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The NASA Electronic Parts and Packaging (NEPP) Program: Insertion of New Electronics Technologies

This viewgraph presentation gives an overview of NASA Electronic Parts and Packaging (NEPP) Program's new electronics technology trends. The topics include: 1) The Changing World of Radiation Testing of Memories; 2) Even Application-Specific Tests are Costly!; 3) Hypothetical New Technology Part Qualification Cost; 4) Where we are; 5) Approaching FPGAs as a More Than a "Part" for Reliability; 6) FPGAs Beget Novel Radiation Test Setups; 7) Understanding the Complex Radiation Data; 8) Tracking Packaging Complexity and Reliability for FPGAs; 9) Devices Supporting the FPGA Need to be Considered; 10) Summary of the New Electronic Technologies and Insertion into Flight Programs Workshop; and 11) Highlights of Panel Notes and Comments

LaBel, Kenneth A.↗

Damper reduces effects of resonance on force transducer

Viscous-film damper eliminates response lag of resonance generated noise when inserted into the thrust measuring system. This technique can be applied to automated devices when pulsed force or low order impact is involved, and where signal noise is produced by stopping or reversal of mechanical travel or by water hammer.

Postma, R. W.↗

Estimation of automobile-driver describing function from highway tests using the double steering wheel

The automobile-driver describing function for lateral position control was estimated for three subjects from frequency response analysis of straight road test results. The measurement procedure employed an instrumented full size sedan with known steering response characteristics, and equipped with a lateral lane position measuring device based on video detection of white stripe lane markings. Forcing functions were inserted through a servo driven double steering wheel coupling the driver to the steering system proper. Random appearing, Gaussian, and transient time functions were used. The quasi-linear models fitted to the random appearing input frequency response characterized the driver as compensating for lateral position error in a proportional, derivative, and integral manner. Similar parameters were fitted to the Gabor transformed frequency response of the driver to transient functions. A fourth term corresponding to response to lateral acceleration was determined by matching the time response histories of the model to the experimental results. The time histories show evidence of pulse-like nonlinear behavior during extended response to step transients which appear as high frequency remnant power.

Delp, P.↗

Low power arcjet performance

An experimental investigation was performed to evaluate arc jet operation at low power. A standard, 1 kW, constricted arc jet was run using nozzles with three different constrictor diameters. Each nozzle was run over a range of current and mass flow rates to explore stability and performance in the low power engine. A standard pulse-width modulated power processor was modified to accommodate the high operating voltages required under certain conditions. Stable, reliable operation at power levels below 0.5 kW was obtained at efficiencies between 30 and 40 percent. The operating range was found to be somewhat dependent on constrictor geometry at low mass flow rates. Quasi-periodic voltage fluctuations were observed at the low power end of the operating envelope, The nozzle insert geometry was found to have little effect on the performance of the device. The observed performance levels show that specific impulse levels above 350 seconds can be obtained at the 0.5 kW power level.

Curran, Francis M.↗

Low power arcjet performance

An experimental investigation was performed to evaluate arcjet operation at low power. A standard, 1 kW, constricted arcjet was run using nozzles with three different constrictor diameters. Each nozzle was run over a range of current and mass flow rates to explore stability and performance in the low power regime. A standard pulse-width modulated power processor was modified to accommodate the high operating voltages required under certain conditions. Stable, reliable operation at power levels below 0.5 kW was obtained at efficiencies between 30 and 40 percent. The operating range was found to be somewhat dependent on constrictor geometry at low mass flow rates. Quasi-periodic voltage fluctuations were observed at the low power end of the operating envelope. The nozzle insert geometry was found to have little effect on the performance of the device. The observed performance levels show that specific impulse levels above 350 seconds can be obtained at the 0.5 kW power level.

Curran, Francis M.↗

Pressure Measurements During Flight

The general idea was to record the air pressure on the spot, that is, without intervening tubes, by some simple automatic registering device. This was therefore made in such small dimensions that it could be inserted into the wing between the ribs and stand in direct connection with the pressure openings. The results of different experiments are presented along with the best locations for locating the instruments for recording the pressure.

Proll, A↗

First Materials Science Research Rack Capabilities and Design Features

The first Materials Science Research Rack (MSRR-1) will accommodate dual Experiment Modules (EM's) and provide simultaneous on-orbit processing operations capability. The first international Materials Science Experiment Module for the MSRR-1 is an international cooperative research activity between NASA's Marshall Space Flight Center (MSFC) and the European Space Agency's (ESA) European Space Research and Technology Center. (ESTEC). This International Standard Payload Rack (ISPR) will contain the Materials Science Laboratory (MSL) developed by ESA as an Experiment Module. The MSL Experiment Module will accommodate several on-orbit exchangeable experiment-specific Module Inserts. Module Inserts currently planned are a Quench Module Insert, Low Gradient Furnace, Solidification with Quench Furnace, and Diffusion Module Insert. The second Experiment Module for the MSRR-1 configuration is a commercial device supplied by MSFC's Space Products Department (SPD). It includes capabilities for vapor transport processes and liquid metal sintering. This Experiment Module will be replaced on-orbit with other NASA Materials Science EMs.

Schaefer, D.↗

Miniature Trace Gas Detector Based on Microfabricated Optical Resonators

While a variety of techniques exist to monitor trace gases, methods relying on absorption of laser light are the most commonly used in terrestrial applications. Cavity-enhanced absorption techniques typically use high-reflectivity mirrors to form a resonant cavity, inside of which a sample gas can be analyzed. The effective absorption length is augmented by the cavity's high quality factor, or Q, because the light reflects many times between the mirrors. The sensitivity of such mirror-based sensors scales with size, generally making them somewhat bulky in volume. Also, specialized coatings for the high-reflectivity mirrors have limited bandwidth (typically just a few nanometers), and the delicate mirror surfaces can easily be degraded by dust or chemical films. As a highly sensitive and compact alternative, JPL is developing a novel trace gas sensor based on a monolithic optical resonator structure that has been modified such that a gas sample can be directly injected into the cavity. This device concept combines ultra-high Q optical whispering gallery mode resonators (WGMR) with microfabrication technology used in the semiconductor industry. For direct access to the optical mode inside a resonator, material can be precisely milled from its perimeter, creating an open gap within the WGMR. Within this open notch, the full optical mode of the resonator can be accessed. While this modification may limit the obtainable Q, calculations show that the reduction is not significant enough to outweigh its utility for trace gas detection. The notch can be milled from the high- Q crystalline WGMR with a focused ion beam (FIB) instrument with resolution much finer than an optical wavelength, thereby minimizing scattering losses and preserving the optical quality. Initial experimental demonstrations have shown that these opened cavities still support high-Q whispering gallery modes. This technology could provide ultrasensitive detection of a variety of molecular species in an extremely compact and robust package. With this type of modified WGMR, one can inject a gas sample into the open gap, allowing highly sensitive trace molecule detection within a roughly 1-cm volume. Other critical components of the instrument, such as the detector and a semiconductor laser, could be directly packaged with the resonator so as to not significantly increase the size of the device. Besides its low mass, volume, and power consumption, the monolithic design makes these resonators intrinsically robust devices, capable of handling significant temperature excursions, without moving parts to wear out or delicate coatings that can be easily damaged. A sensor could integrate with microfluidics technology for a chip-scale device. It could be mounted to the end of a deployable arm, or inserted into a borehole. Also, a network of individual sensors could be dispersed to monitor conditions over a wide region

Aveline, David C.↗

Analysis of the Measurement and Modeling of a Digital Inverter Based on a Ferroelectric Transistor

The use of ferroelectric materials for digital memory devices is widely researched and implemented, but ferroelectric devices also possess unique characteristics that make them have interesting and useful properties in digital circuits. Because ferroelectric transistors possess the properties of hysteresis and nonlinearity, a digital inverter containing a FeFET has very different characteristics than one with a traditional FET. This paper characterizes the properties of the measurement and modeling of a FeFET based digital inverter. The circuit was set up using discrete FeFETs. The purpose of this circuit was not to produce a practical integrated circuit that could be inserted directly into existing digital circuits, but to explore the properties and characteristics of such a device and to look at possible future uses. Input and output characteristics are presented, as well as timing measurements. Comparisons are made between the ferroelectric device and the properties of a standard digital inverter. Potential benefits and possible uses of such a device are presented.

MacLeod, Todd C.↗

JSC systems using solid ceramic oxygen electrolyte cells to measure oxygen fugacites in gas-mixing systems

Details are given for the construction and operation of a 101.3 KN/sq meter (1 atmosphere) redox control system. A solid ceramic oxygen electrolyte cell is used to monitor the oxygen fugacity in the furnace. The system consists of a vertical quench gas mixing furnace with heads designed for mounting the electrolyte cell and with facilities for inserting and removing the samples, a simplified version of a gas mixing apparatus, and devices for experiments under controlled rates of change of temperature. A thermogravimetric analysis system employing these techniques of redox control and measurement is also described. The calibration and maintenance of the system are discussed.

Williams, R. J.↗

Jig Aligns Shadow Mask On CCD

Alignment viewed through microscope. Alignment jig positions shadow mask on charge-coupled device (CCD) so metal film deposited on it precisely. Allows CCD package to be inserted and removed without disturbing alignment of mask. Holds CCD packages securely and isolates it electrostatically while providing electrical contact to each of its pins. When alignment jig assembled with CCD, used to move mask under micrometer control.

Matus, Carlos V.↗

Microanalysis of extended-test xenon hollow cathodes

Four hollow cathode electron sources were analyzed via boroscopy, scanning electron microscopy, energy dispersive x ray analysis, and x ray diffraction analysis. These techniques were used to develop a preliminary understanding of the chemistry of the devices that arise from contamination due to inadequate feed-system integrity and improper insert activation. Two hollow cathodes were operated in an ion thruster simulator at an emission current of 23.0 A for approximately 500 hrs. The two tests differed in propellant-feed systems, discharge power supplies, and activation procedures. Tungsten deposition and barium tungstate formation on the internal cathode surfaces occurred during the first test, which were believed to result from oxygen contamination of the propellant feed-system. Consequently, the test facility was upgraded to reduce contamination, and the test was repeated. The second hollow cathode was found to have experienced significantly less tungsten deposition. A second pair of cathodes examined were the discharge and the neutralizer hollow cathodes used in a life-test of a 30-cm ring-cusp ion thruster at a 5.5 kW power level. The cathodes' test history was documented and the post-test microanalyses are described. The most significant change resulting from the life-test was substantial tungsten deposition on the internal cathode surfaces, as well as removal of material from the insert surface. In addition, barium tungstate and molybdate were found on insert surfaces. As a result of the cathode examinations, procedures and approaches were proposed for improved discharge ignition and cathode longevity.

Verhey, Timothy R.↗

Mission Advantages of Constant Power, Variable Isp Electrostatic Thrusters

Electric propulsion has moved from station-keeping capability for spacecraft to primary propulsion with the advent of both the Deep Space One asteroid flyby and geosynchronous spacecraft orbit insertion. In both cases notably more payload was delivered than would have been possible with chemical propulsion. To provide even greater improvements electrostatic thruster performance could be varied in specific impulse, but kept at constant power to provide better payload or trip time performance for different mission phases. Such variable specific impulse mission applications include geosynchronous and low earth orbit spacecraft stationkeeping and orbit insertion, geosynchronous reusable tug missions, and interplanetary probes. The application of variable specific impulse devices is shown to add from 5 to 15% payload for these missions. The challenges to building such devices include variable voltage power supplies and extending fuel throughput capabilities across the specific impulse range.

Oleson, Steven R.↗

A Survey of Power Electronics Applications in Aerospace Technologies

The insertion of power electronics in aerospace technologies is becoming widespread. The application of semiconductor devices and electronic converters, as summarized in this paper, includes the International Space Station, satellite power system, and motor drives in 'more electric' technology applied to aircraft, starter/generators and reusable launch vehicles. Flywheels, servo systems embodying electromechanical actuation, and spacecraft on-board electric propulsion are discussed. Continued inroad by power electronics depends on resolving incompatibility of using variable frequency for 400 Hz-operated aircraft equipment. Dual-use electronic modules should reduce system development cost.

Kankam, M. David↗

Overview of NASA's Microgravity Materials Program

The NASA Microgravity Materials Program currently funds 19 grants involving the development of experiments to be conducted on the International Space Station (ISS). These experiments are designed to utilize facilities built by partner agencies, primarily the European Space Agency. These facilities include furnace inserts to the Materials Science Research Rack, the Electro-Magnetic Levitator, and the Device for the study of Critical Liquids and Crystallization (DECLIC) facility. Projects are funded either through proposals responding to NASA announcements or unsolicited proposals associated with an international collaboration that is partially funded by a partner agency. An overview of the research content of the program, how potential investigations are solicited, reviewed and funded, and the operations of the ISS facilities is provided.

Downey, James Patton↗

Microminiature Monitor for Vital Electrolyte and Metabolite Levels of Astronauts

Ions, such as proton (pH) and potassium, play a crucial role in body fluids to maintain proper basic functioning of cells and tissues. Metabolites, such as glucose, control the energy available to the entire human body in normal as well as stress situations, and before, during, and after meals. These molecules diffuse easily between blood in the capillaries and the interstitial fluid residing between cells and tissues. We have developed and approach to monitoring of critical ions (called electrolytes) and glucose in the interstitial fluid under the human skin. Proton and potassium levels sensed using optode technology that translates the respective ionic concentrations into variable colors of corresponding ionophore/dye/polymeric liquid membranes. Glucose is monitored indirectly, by coupling through immobilized glucose oxidase with local pH that is then detected using a similar color scheme. The monitor consists of a tiny plastic bar, 100-200 microns wide and 1-2 mm long, placed just under the skin, with color changing spots for each analyte as well as blanks. The colors are read and translated into concentration values by a CCD camera. Direct optical coupling between the in vivo sensing bar and the ex vivo detector device requires no power, and thus eliminates the need for wires or optical fibers crossing the skin. The microminiature bar penetrates the skin easily and painlessly, so that astronauts could insert it themselves. The approach is fully compatible with telemetry in space, and thus, in vivo clinical data will be available real time in the Earth based command center once the device is fully developed. The information provided can be used for collecting hitherto unavailable vital data on clinical effects of space travel. Managing clinical emergencies in space with the sensor already in place should also become much more efficient than without a continuous monitor, as is currently the case. Civilian applications may include better glucose control of patients with moderate to severe diabetes: a growing health problem in the US and World-wide.

Tohda, Koji↗

Behavior of Langmuir Probes in Non-Equilibrium Plasmas

Langmuir probes are diagnostic tools used to determine electron temperature, number density, and plasma potential. Irving Langmuir first used an electrostatic probe in the 1920s to find these characteristics in ionized gases. Single, double, and triple Langmuir probes are commonly used in plasma diagnostics because of their relative simplicity. In the single probe, a swept voltage is applied between the probe tip and circuit common to acquire a waveform showing the collected current as a function of applied voltage. A double Langmuir probe consists of two tips, both inserted into the plasma, with a voltage applied between them. As this voltage is swept, a current-voltage characteristic is measured. In a triple probe three probe tips are electrically coupled to each other with constant non-swept voltages applied between each of the tips. The voltages are selected to represent three points on the single Langmuir probe I-V curve. Elimination of the voltage sweep makes it possible to measure time-varying plasma properties in transient plasmas. Triple Langmuir probe measurements have been widely employed for various types of plasmas, including pulsed and time-varying plasmas such as those seen in pulsed plasma thrusters (PPTs), dense plasma focus devices, plasma flows, and fusion experiments. The typical Langmuir probe analysis for determining electron temperature and number density of the plasma (for a single, double, or triple Langmuir probe) includes an assumption that the plasma is in thermal equilibrium. While the this assumption may be justified for some applications, it is unlikely that it is fully justifiable for pulsed and time-varying plasmas or for the entire time a plasma device is in use. In the present work, we model the responses of Langmuir probes as they are inserted into a range of simple equilibrium and non-equilibrium plasmas. We return to basic governing equations of probe current collection and compute the current to the probes for a distribution function consisting of two Maxwellian distributions with different temperatures (the two-temperature Maxwellian). A variation of this method is also employed, where one of the Maxwellians is offset from zero (in velocity space) to add a suprathermal beam of electrons to the tail of the main Maxwellian distribution (the bump-on-the-tail distribution function). For a range of parameters in these non-Maxwellian distributions, we compute the current collection to the probes. Comparing the distribution function that was assumed a priori with the plasma density and temperature one would infer when applying standard probe theory to analyze the collected currents serves to illustrate the effect a non- Maxwellian plasma would have on results interpreted using the equilibrium probe current collection theory, allowing us to state the magnitudes of these deviations as a function of the assumed distribution function properties.

Polzin, Kurt A.↗