Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrument calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Heterogeneous Graph Neural Network for identifying hadronically decayed tau leptons at the High Luminosity LHC

Here, we present a new algorithm that identifies reconstructed jets originating from hadronic decays of tau leptons against those from quarks or gluons. No tau lepton reconstruction algorithm is used. Instead, the algorithm represents jets as heterogeneous graphs with tracks and energy clusters as nodes and trains a Graph Neural Network to identify tau jets from other jets. Different attributed graph representations and different GNN architectures are explored. We propose to use differential track and energy cluster information as node features and a heterogeneous sequentially-biased encoding for the inputs to final graph-level classification.

47 OTHER INSTRUMENTATION↗

Thermochemical Property Measurements of FLiNaK and FLiBe in FY 2020

The technical bases and methods developed at Argonne to measure thermochemical properties of molten salt mixtures are summarized and results provided to show the precision achieved. These methods include measurements of phase transition temperatures and heat capacity at temperatures to approximately 700 °C for eutectic mixture of 46.5-11.5-42.0 mol% LiF-NaF-KF (FLiNAK) and 67-33 mol% LiF-BeF 2 (FLiBe). Details of procedures, calibrations and operation of instruments are discussed and results are compared with values available in the literature. Additional discussions address the sources of error and estimated uncertainties in the reported values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermochemical Property Measurements of FLiNaK and FLiBe in FY 2020

The technical bases and methods developed at Argonne to measure thermochemical properties of molten salt mixtures are summarized and results provided to show the precision achieved. These methods include measurements of phase transition temperatures and heat capacity at temperatures to approximately 700°C for eutectic mixture of 46.5-11.5-42.0 mol% LiF-NaF-KF (FLiNaK) and 67-33 mol% LiF-BeF 2 (FLiBe). Details of procedures, calibrations and operation of instruments are discussed, and results are compared with values available in the literature. Additional discussions address the sources of error and estimated uncertainties in the reported values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Specifications of Cladding Diameter Measurements Conducted at AGHCF

Fuel element diameter data was collected on-site at the Alpha-Gamma Hot Cell Facility (AGHCF) before and after out-of-pile furnace transient tests of fuel elements. Available data records have been collected and preserved in the Out-of-Pile Transient Database (OPTD). This data is used to determine the transient-induced changes in fuel element diameter, or cladding strain, for the Whole Pin Furnace (WPF) tests. Fuel element diameter was measured by contact profilometry along the length of the fuel pin at specified rotational orientations and/or by a manually operated micrometer at several discrete axial locations along the pin. The Alpha-Gamma Hot Cell Facility Operations Manual details the way the facility operated, organizational and oversight responsibilities, and procedures for examination of samples. The working version of the manual at the time of the whole pin furnace tests and the test pin examinations is Doc. No. IPS-2-00-00, dated June 1989. This specification was developed using the operations manual and recovered measurement records in consultation with subject matter experts (SMEs). The measurement methods, format of the available post-test examination (PTE) data, and recommended methods for use and interpretation of that data are summarized. Section 2 describes the available diameter measurement data for the WPF tests with guidance for interpretation and usage, and Section 3 describes the instrument measurement procedures and calibration methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extension of SCALE/Sampler’s sensitivity index for the assessment of cross section, fission yield, and decay data uncertainties

Accurate prediction of nuclide compositions and neutron and gamma sources and spectra for fresh and spent nuclear fuel through computational modeling and simulations is the basis for safeguards instruments design, optimization, and calibration, and for validation of the measured responses. The accuracy of these simulations can be significantly impacted by uncertainties in input parameters to the applied computer code. Input parameters are, for example, dimensions, material compositions, and temperatures of the model. Additionally, important but sometimes neglected input parameters for simulations of nuclear systems are the nuclear data that include nuclear reaction cross sections, fission product yields, and decay data. It has been shown that uncertainties of calculated results are dominated by uncertainties of these nuclear data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Radius of PSR J0740+6620 from NICER with NICER Background Estimates

We report a revised analysis for the radius, mass, and hot surface regions of the massive millisecond pulsar PSR J0740+6620, studied previously with joint fits to NICER and XMM-Newton data by Riley et al. (2021) and Miller et al. (2021). We perform a similar Bayesian estimation for the pulse-profile model parameters, except that instead of fitting simultaneously the XMM-Newton data, we use the best available NICER background estimates to constrain the number of photons detected from the source. This approach eliminates any potential issues in the cross-calibration between these two instruments, providing thus an independent check of the robustness of the analysis. The obtained neutron star parameter constraints are compatible with the already published results, with a slight dependence on how conservative the imposed background limits are. A tighter lower limit causes the inferred radius to increase, and a tighter upper limit causes it to decrease. We also extend the study of the inferred emission geometry to examine the degree of deviation from antipodality of the hot regions. We show that there is a significant offset to an antipodal spot configuration, mainly due to the non-half-cycle azimuthal separation of the two emitting spots. The offset angle from the antipode is inferred to be above 25° with 84% probability. This seems to exclude a centered-dipolar magnetic field in PSR J0740+6620.

79 ASTRONOMY AND ASTROPHYSICS↗

Analyzing the Calibration History of Radiometers for Determining Optimal Calibration Day(s)

This study investigates the effects of calibrating radiometers using one day or multiple cloudless days as recommended by ASTM and ISO standards. The results demonstrate good responsivity agreement with estimated uncertainty error bars over the years for various radiometers under various Broadband Outdoor Radiometer Calibration (BORCAL) events at both the National Renewable Energy Laboratory and the Southern Great Plains facility. The BORCAL method appears to justify the use of a single calibration day with enough data points to attain repeatable calibration results.

BORCAL↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Calibration of the Falcon Solid-state Energetic Electron Detector (SEED)

The Falcon Solid-state Energetic Electron Detector (FalconSEED) is an energetic charged particle sensor that has been developed and tested at the United States Air Force Academy in an effort to monitor electron flux across the energy range of 14 to 145 keV in geosynchronous orbit. This sensor has been developed to complement ongoing efforts by the Air Force Research Laboratory to advance a comprehensive space environment sensor suite, Compact Environmental Anomaly Sensor (CEASE3), for anomaly resolution. In addition, FalconSEED is intended to demonstrate the ability to operate a radiation sensor based on predominantly commercial off the shelf components in the geosynchronous environment. This paper describes the design, development, and calibration of FalconSEED. The electron energy spectrum of interest for the FalconSEED sensor is 14 to 145 keV, and is intended to supplement data acquired from the CEASE3 instrument for anomaly resolution. The calibrations at the Space Atmospheric Research Center at the United States Air Force Academy and Kirtland Air Force Base were used to first establish the conversion between histogram bin number and deposited energy in the sensor, and second have been used to determine the geometric factor as a function of energy. The FalconSEED will be integrated as a science payload on the Space Test Program Satellite-6 which also includes the first flight of the CEASE3 instrument and is scheduled to launch in 2021.

47 OTHER INSTRUMENTATION↗

Comparison of temperature adaptive calibration methods for laser induced fluorescence based fuel-in-oil instrument

Fuel dilution of engine oil (or fuel-in-oil, FiO) is an important issue as multiple and late-cycle fuel injection, integral to many combustion efficiency and emissions improvements (e.g., downsized boosted gasoline engines and catalyst thermal management) increases FiO rate. In addition to causing general wear and corrosion in engine due to decreased oil viscosity and pH buffering, FiO is also believed to cause destructive low speed pre-ignition (or super knock) in boosted SI engines. To understand the effects of engine operating conditions on the FiO rate, an optical diagnostic capable of measuring transient FiO on minute timescales was recently developed and demonstrated on a modified GM Ecotech engine system (Neupane et al., Applied Spectroscopy 2021). The measurement is based on adding a dye to the fuel and monitoring for its presence in oil via laser-induced fluorescence (LIF). The measured LIF signal is related to FiO concentration via pre-determined calibration factors using a multivariate classical least square (CLS) method.Since fluorescence quantum yield is a function of temperature, measured LIF intensity not only depends on FiO concentration but also oil temperature. To expand the applicability of the FiO diagnostic to transient oil-temperature conditions (e.g., cold start in practical engines), this study develops a method to account for oil-temperature variations. The effect of oil temperature (20°C - 95°C) on the LIF spectra of eight FiO samples ranging from ~0.8-15% was investigated. LIF intensities of the FiO samples decreased linearly with increasing temperature; the reductions being more significant at dye peaks. We develop a new calibration model (T-adaptive CLS) incorporating the temperature (T) effects on LIF intensity that enables simultaneous calculation of FiO and oil temperature. The improved FiO diagnostic with T-adaptive calibration is more robust, and applicable to varying oil-temperature conditions. For example, when strategies such as multiple/late fuel injections are applied to overcome cold-start instability due to use of low vaporization bio-based fuels such as ethanol, FiO rate is expected to be very high; the improved T-adaptive FiO diagnostic is hence relevant for engine- and fuel-system calibration and optimization. The diagnostic could also provide validation data for flow-field and spray interaction CFD models, further broadening the diagnostic’s utility for advancing engine technology and efficiency.

Neupane, Sneha↗

Characterization of SimulCam, a standoff Raman system for scientific support of SuperCam operations on Mars

During the development activities of SuperCam Calibration Target, target intended for one of the two first Raman instruments to be deployed on another planetary body, our group developed a laboratory instrument that could simulate to some extent the Raman capabilities of one of such instruments and could provide data with similar quality. The use of this kind of laboratory instruments has demonstrated its utility in the evaluation of potential calibration targets or anticipating the science outcome that an instrument could provide. The present work describes our laboratory setup to support SuperCam, evaluating similarities between both instruments, despite of differences in the hardware. Evaluation of data gathered by SuperCam on Mars and the availability of one replica of SuperCam’s Calibration Target allowed the comparison on the same set of targets, demonstrating how similar Signal-to-Noise Ratio (SNR) could be achieved from both instruments. The higher energy per pulse on SimulCam is compensated by a greater analytical footprint and the use of smaller collection optics. The results show how spectra obtained at representative distances of SuperCam are comparable. Operational principles are also comparable in terms of time resolution, and close in terms of spectral resolution. This similarity has allowed different science support works using SimulCam data, as well as the support to Mars detections using our setup. We provide examples of this support that will be shared with the community in different papers, as well as examples of possible operations activities that could benefit from experiments performed with SimulCam. We show how this setup can complement the two laboratory replicas in Los Alamos and Toulouse in providing support data to different experiments.

47 OTHER INSTRUMENTATION↗

Applications of Alternate Actinide Calibration on Inductively Coupled Plasma Mass Spectrometry (ICPMS) Analysis of H-Canyon Highly Enriched Uranium Legacy Material at the Savannah River Site (SRS)

The Savannah River National Laboratory (SRNL) uses Inductively Coupled Plasma Mass Spectrometry (ICPMS) to support numerous programs at the Savannah River Site (SRS). As part of an objective to prepare high assay low enriched uranium (HALEU), the SRS H-Canyon needed analysis of legacy uranyl nitrate that is stored at its Outside Facilities (HOF). With the application of a standard practice for alternate actinide calibration on ICP-MS, SRNL has successfully demonstrated its capability to characterize the uranium/actinide composition of the HOF tanks that are intended for consolidation prior to preparation of the HALEU. A comparison of the uranium analytical results between recently upgraded SRNL ICP-MS and Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) instrumentation shows the alternate actinide calibration is a valid complementary method when used in conjunction with other analytical techniques (Davies-Gray Potentiometric Titration). The methods, instrumentation, and ongoing developments on ICP-MS at SRNL will be discussed.

Jones, Mark A.↗

Revised astrometric calibration of the Gemini Planet Imager

We present a revision to the astrometric calibration of the Gemini Planet Imager (GPI), an instrument designed to achieve the high contrast at small angular separations necessary to image substellar and planetary-mass companions around nearby, young stars. We identified several issues with the GPI data reduction pipeline (DRP) that significantly affected the determination of the angle of north in reduced GPI images. As well as introducing a small error in position angle measurements for targets observed at small zenith distances, this error led to a significant error in the previous astrometric calibration that has affected all subsequent astrometric measurements. We present a detailed description of these issues and how they were corrected. We reduced GPI observations of calibration binaries taken periodically since the instrument was commissioned in 2014 using an updated version of the DRP. These measurements were compared to observations obtained with the NIRC2 instrument on Keck II, an instrument with an excellent astrometric calibration, allowing us to derive an updated plate scale and north offset angle for GPI. This revised astrometric calibration should be used to calibrate all measurements obtained with GPI for the purposes of precision astrometry.

79 ASTRONOMY AND ASTROPHYSICS↗

SuperCam Calibration Targets: Design and Development

Abstract SuperCam is a highly integrated remote-sensing instrumental suite for NASA’s Mars 2020 mission. It consists of a co-aligned combination of Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), Visible and Infrared Spectroscopy (VISIR), together with sound recording (MIC) and high-magnification imaging techniques (RMI). They provide information on the mineralogy, geochemistry and mineral context around the Perseverance Rover. The calibration of this complex suite is a major challenge. Not only does each technique require its own standards or references, their combination also introduces new requirements to obtain optimal scientific output. Elemental composition, molecular vibrational features, fluorescence, morphology and texture provide a full picture of the sample with spectral information that needs to be co-aligned, correlated, and individually calibrated. The resulting hardware includes different kinds of targets, each one covering different needs of the instrument. Standards for imaging calibration, geological samples for mineral identification and chemometric calculations or spectral references to calibrate and evaluate the health of the instrument, are all included in the SuperCam Calibration Target (SCCT). The system also includes a specifically designed assembly in which the samples are mounted. This hardware allows the targets to survive the harsh environmental conditions of the launch, cruise, landing and operation on Mars during the whole mission. Here we summarize the design, development, integration, verification and functional testing of the SCCT. This work includes some key results obtained to verify the scientific outcome of the SuperCam system.

Manrique, J. A. (ORCID:0000000220532819)↗

INL CRMO XRF Special Report No. 3: INL CRMO XRF Calibration Methods for the Analysis of Ceramics and Brick

This report details the analytical methods used by the Idaho National Laboratory Cultural Resource Management Office to characterize ceramic and brick artifacts using X-ray fluorescence spectrometry. More specifically, this report provides details on instrumentation, analysis times, and matrix-specific calibration protocols for ceramic materials. Calibration curves were developed to adjust raw instrumental output for 13 elements using a suite of reference standards made from historic brick borrowed from the Yale Peabody Museum. Calibration curves were validated by plotting predicted values against published reference values for the calibration set as well as a certified soil reference standard (SRM 2711a).

36 MATERIALS SCIENCE↗

Machine learning for imaging Cherenkov detectors

Imaging Cherenkov detectors are largely used in modern nuclear and particle physics experiments where cutting-edge solutions are needed to face always more growing computing demands. This is a fertile ground for AI-based approaches and at present we are witnessing the onset of new highly efficient and fast applications. This paper presents novel directions with applications to Cherenkov detectors. In particular, recent advances on detector design and calibration, as well as particle identification are presented.

47 OTHER INSTRUMENTATION↗

Quantification of Hydrogen Isotopes Utilizing Raman Spectroscopy Paired with Chemometric Analysis for Application across Multiple Systems

On-line and real-time analysis of a chemical process is a major analytical challenge that can drastically change the way the chemical industry or chemical research operates. With in situ analyses, new and powerful understanding of chemistry can be gained; however, building robust tools for long-term monitoring faces many challenges that include compensating for instrument drift, instrument replacement, and sensor or probe replacement. Accounting for these changes by recollecting calibration data and rebuilding quantification models can be costly and time consuming. Here, in this study, methods to overcome these challenges are demonstrated with an application of Raman spectroscopy to monitoring hydrogen isotopes with varied speciation within dynamic gas streams. Specifically, chemical data science tools such as chemometric modeling are leveraged along with several examples of calibration transfer approaches. Furthermore, the optimization of instrument and sensors cell parameters for targeted gas phase analyses is discussed. While the particular focus on hydrogen is highly beneficial within the nuclear energy sector, mechanisms built and demonstrated here are widely applicable to optical spectroscopy monitoring in numerous other chemical systems that can be leveraged in other hazardous processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-contact velocity measurement instruments and systems, and related methods

Methods for calibration of non-contact velocity measurements and systems for implementing the same are described. Generally, the method comprises inducing a shock wave into a sample at a stress intensity that varies across the sample's elastic limit, which corresponds to the elastic-plastic state transition of the sample. That transition state may be at the sample's Hugoniot elastic limit. The velocity of the sample is measured using a non-contact velocity measurement instrument such as a velocimeter. The measurement may be compared to a predicted velocity or a velocity measurement made by another system to determine calibration parameters.

47 OTHER INSTRUMENTATION↗