Search NASA⌕ Search

SEARCH · Search NASA

Results for “integrated storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

MFRED, 10 second interval real and reactive power for groups of 390 US apartments of varying size and vintage

Abstract Building electricity is a major component of global energy use and its environmental impacts. Detailed data on residential electricity use have many interrelated research applications, from energy conservation to non-intrusive load monitoring, energy storage, integration of renewables, and electric vs. fossil-based heating. The dataset presented here, Multifamily Residential Electricity Dataset (MFRED), contains the electricity use of 390 apartments, ranging from studios to four-bedroom units. All apartments are located in the Northeastern United States (IECC-climate-zone 4 A), but differ in their heating/cooling system and construction year (early to late 20 th century). To adhere to privacy guidelines, data were averaged across 15 apartments each, based on annual electricity use. MFRED includes real and reactive power, at 10-second resolution, for January to December 2019 (246 million data points). The annual average real power per apartment is 343 W (3.27 W/m 2 of floor area), with strong variation between seasons and apartment size. Considering its large number of apartments, high time resolution, real and reactive power, and 12-month duration, MFRED is currently unique for the multifamily-sector.

97 MATHEMATICS AND COMPUTING↗

Device Voltage Stress from Ground Leakage Current in Medium-Voltage Solid-State Transformer

Grounding related issues are critical for safe and reliable operation of solid-state transformer (SST) in medium-voltage (MV) applications, e.g., solar photovoltaic and energy storage integration, date center, electric vehicle fast charging, etc. This article presents for the first time the issue of additional device voltage stress due to grounding-loop current in current-source SST, using the soft-switching solid-state transformer (S4T) as an example. The S4T features single-stage isolated AC-AC, AC-DC, or DC-DC conversion with full-range ZVS, derived from flyback converter or current-source converter (CSC). However, the flyback operation for CSC-based SST means that magnetizing current flows through the reverse-blocking devices on only one side of the medium-frequency transformer (MFT) at a time. Then, the voltages across the devices, especially those on the other side of the MFT, can be influenced by parasitic current. A parasitic model of a modular S4T (M-S4T) prototype is developed from direct measurements and datasheets. Using the developed parasitic model and equivalent circuits, the causes of the voltage stress are analyzed. A voltage-stress mitigation scheme of connecting additional grounding capacitors is proposed. Damping resistors are also installed to damp out the grounding-loop resonance. A robust parameter design of the proposed scheme is given. The existence of the voltage stress issue and the effectiveness of the proposed scheme are verified experimentally on an MV SiC M-S4T prototype with inherent parameter variations among the five modules in the prototype. Here, both single-module and stacked-module operation are demonstrated during steady state and dynamic conditions up to 4 kV peak.

42 ENGINEERING↗

NSDS Nuclear Science Data Solutions [Poster]

NSDS is the adept coordination of Los Alamos National Laboratory's nuclear science data, including the collection, integration, storage and access. The poster highlights historical milestones.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Optimizing Carbon Capture, Transport, and Storage: Overcoming Challenges with Machine Learning and Cost-Benefit Analysis

Carbon Capture, Utilization, and Storage (CCUS) is a critical strategy for reducing CO₂ emissions and mitigating climate change. However, its widespread deployment faces numerous challenges across the capture, transport, and storage phases. These challenges include the technical complexity of predicting subsurface behaviors during CO₂ injection, ensuring long-term storage integrity, optimizing transportation networks, and balancing the economic and environmental trade-offs. Addressing these issues requires an integrated approach combining advanced subsurface modeling with system-level analyses to assess costs, risks, and benefits. This presentation provides an overview of studies conducted by the National Energy Technology Laboratory (NETL) to tackle these challenges. NETL’s efforts encompass cutting-edge research in subsurface fluid behavior machine learning predictions, alongside the development of innovative tools for system optimization and economic evaluation. By bridging technical expertise and strategic analysis, NETL aims to advance the deployment of CCUS technologies to support global decarbonization efforts. Presented at the Carnegie Mellon University CEE IESS Student Seminar October 4, 2024.

Shih, Chung Yan↗

National Aeronautics and Space Administration fundamental research program. Information utilization and evaluation

In the second half of the 1980's NASA can expect to face difficult choices among alternative fundamental and applied research, and development projects that could potentially lead to improvements in the information systems used to manage renewable resources. The working group on information utilization and evaluation believes that effective choices cannot be made without a better understanding of the current and prospective problems and opportunities involved in the application of remote sensing to improve renewable research information systems. A renewable resources information system is defined in a broad context to include a flow of data/information from: acquisition through processing, storage, integration with other data, analysis, graphic presentation, decision making, and assessment of the affects of those decisions.

Estes, J. E.↗

Thermal storage analysis for large manned space platforms

High electrical power and waste heat rejection is projected for future manned low earth orbit space platforms, such as Space Station. The high heat rejection, optical coating degradation, long operating life with minimum maintenance requirements pose a challenging thermal management design problem. System optimization, with respect to radiator area and weight, indicate the requirement for thermal storage. This paper examines the thermal storage benefits, determines the characteristics as applied to different TMS concepts (e.g., centralized, decentralized), and examines the similarities and differences of thermal storage integration with single-phase and two-phase systems for a study baseline 75 kWe low earth orbit platform.

Lehtinen, A. M.↗

A new light on caloric test--what was disclosed by three dimensional analysis of caloric nystagmus?

For better understanding of caloric nystagmus, this phenomenon will be reviewed historically in three stages. 1) The first light on caloric nystagmus was thrown by Barany 1906. Through direct observation of eye movements, Barany established the caloric test as an important tool to determine the side of lesion for vertigo. 2) The second light is shed by electrooculogram (EOG) from the late 1950th. EOG enabled qualitative analysis of caloric nystagmus, and proved Barany's convection theory, but resulted in neglect of vertical and roll eye movements. 3) The third light is gained by 3D recording of eye movements started from the late 1980th. 3D recordings of eye movements enabled us to analyze the spatial orientation of caloric nystagmus, and disclose the close correlation of the nystagmus components in the head vertical and the space vertical planes, suggesting a contribution of the velocity storage integrator. The 3D property of caloric nystagmus will be explained in detail.

Caloric Tests/history↗

Spatial orientation of the vestibular system

1. A simplified three-dimensional state space model of visual vestibular interaction was formulated. Matrix and dynamical system operators representing coupling from the semicircular canals and the visual system to the velocity storage integrator were incorporated into the model. 2. It was postulated that the system matrix for a tilted position was a composition of two linear transformations of the system matrix for the upright position. One transformation modifies the eigenvalues of the system matrix while another rotates the pitch and roll eigenvectors with the head, while maintaining the yaw axis eigenvector approximately spatially invariant. Using this representation, the response characteristics of the pitch, roll, and yaw eye velocity were obtained in terms of the eigenvalues and associated eigenvectors. 3. Using OKAN data obtained from monkeys and comparing to the model predictions, the eigenvalues and eigenvectors of the system matrix were identified as a function of tilt to the side or of tilt to the prone positions, using a modification of the Marquardt algorithm. The yaw eigenvector for right-side-down tilt and for downward pitch cross-coupling was approximately 30 degrees from the spatial vertical. For the prone position, the eigenvector was computed to be approximately 20 degrees relative to the spatial vertical. For both side-down and prone positions, oblique OKN induced along eigenvector directions generated OKAN which decayed to zero along a straight line with approximately a single time constant. This was verified by a spectral analysis of the residual sequence about the straight line fit to the decaying data. The residual sequence was associated with a narrow autocorrelation function and a wide power spectrum. 4. Parameters found using the Marquardt algorithm were incorporated into the model. Diagonal matrices in a head coordinate frame were introduced to represent the direct pathway and the coupling of the visual system to the integrator. Model simulations predicted the behavior of yaw and pitch OKN and OKAN when the animal was upright, as well as the cross-coupling in the tilted position. The trajectories in velocity space were also accurately simulated. 5. There were similarities between the monkey eigenvectors and human perception of the spatial vertical. For side-down tilts and downward eye velocity cross-coupling, there was only an Aubert (A) effect. For upward eye velocity cross-coupling there were both Muller (E) and Aubert (A) effects. The mean of the eigenvectors for upward and downward eye velocities overlay human 1 x g perceptual data.(ABSTRACT TRUNCATED AT 400 WORDS).

NASA Discipline Neuroscience↗

2-kW Solar Dynamic Space Power System Tested in Lewis' Thermal Vacuum Facility

Working together, a NASA/industry team successfully operated and tested a complete solar dynamic space power system in a large thermal vacuum facility with a simulated sun. This NASA Lewis Research Center facility, known as Tank 6 in building 301, accurately simulates the temperatures, high vacuum, and solar flux encountered in low-Earth orbit. The solar dynamic space power system shown in the photo in the Lewis facility, includes the solar concentrator and the solar receiver with thermal energy storage integrated with the power conversion unit. Initial testing in December 1994 resulted in the world's first operation of an integrated solar dynamic system in a relevant environment.

Source record↗

Energy Management Information System Powers NREL's Intelligent Campus

NREL's Intelligent Campus program leverages its own laboratory buildings as research instruments to study renewable energy, energy efficiency, and energy storage, integration, and analysis with real, quantitative measurements. At the heart of NREL's Intelligent Campus program is its Energy Management Information System (EMIS), a family of tools and services used to manage building and campus energy use. NREL's EMIS includes capabilities, such as benchmarking and monthly utility tracking, interval meter analytics, equipment fault detection and diagnostics, condition-based monitoring, and supervisory control, enabling unprecedented energy management capabilities. The system serves as a demonstration project for other federal facilities interested in learning about its design, features, and benefits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy Management Information System Powers NREL's Intelligent Campus

NREL's Intelligent Campus program leverages its own laboratory buildings as research instruments to study renewable energy, energy efficiency, and energy storage, integration, and analysis with real, quantitative measurements. At the heart of NREL's Intelligent Campus program is its Energy Management Information System (EMIS), a family of tools and services used to manage building and campus energy use. NREL's EMIS includes capabilities, such as benchmarking and monthly utility tracking, interval meter analytics, equipment fault detection and diagnostics, condition-based monitoring, and supervisory control, enabling unprecedented energy management capabilities. The system serves as a demonstration project for other federal facilities interested in learning about its design, features, and benefits.

EMIS↗

Zero Boil-Off Methods for Large Scale Liquid Hydrogen Tanks Using Integrated Refrigeration and Storage

NASA has completed a series of tests at the Kennedy Space Center to demonstrate the capability of using integrated refrigeration and storage (IRAS) to remove energy from a liquid hydrogen (LH2) tank and control the state of the propellant. A primary test objective was the keeping and storing of the liquid in a zero boil-off state, so that the total heat leak entering the tank is removed by a cryogenic refrigerator with an internal heat exchanger. The LH2 is therefore stored and kept with zero losses for an indefinite period of time. The LH2 tank is a horizontal cylindrical geometry with a vacuum-jacketed, multi-layer insulation system and a capacity of 125,000 liters. The closed-loop helium refrigeration system was a Linde LR1620 capable of 390W cooling at 20K (without any liquid nitrogen pre-cooling). Three different control methods were used to obtain zero boil-off: temperature control of the helium refrigerant, refrigerator control using the tank pressure sensor, and duty cycling (on/off) of the refrigerator as needed. Summarized are the IRAS design approach, zero boil-off control methods, and results of the series of zero boil-off tests.

ZBO↗

Development of an 400 L Integrated Refrigeration and Storage Cryostat for LNG/LCH4 Research

Research engineers from the Cryogenics Test Laboratory at NASA Kennedy Space Center in Florida have developed a 400 liter Integrated Refrigeration and Storage (IRAS) cryostat to explore advanced techniques for storage, conditioning, and transfer of liquefied natural gas and/or pure methane. A vertical-cylindrical configuration, the vacuum-jacketed apparatus houses a G-M cryocooler to control the state of the fluid, and sample tubes with corresponding temperature sensors fixed at various elevations to allow for sampling of the liquid. Two additional ports were also included for future instrumentation and/or mechanical feed-throughs. A primary goal of this test apparatus will be to study the effect of IRAS on the behavior of LNG during storage; most notably weathering and stratification of the bulk liquid over time. Additionally, in-situ liquefaction of natural gas can be performed, along with zero boil-off control, liquid densification, and slush production.

Swanger, Adam M.↗

Integration of energy storage with diesel generation in remote communities

Highlights Battery energy storage may improve energy efficiency and reliability of hybrid energy systems composed by diesel and solar photovoltaic power generators serving isolated communities. In projects aiming update of power plants serving electrically isolated communities with redundant diesel generation, battery energy storage can improve overall economic performance of power supply system by reducing fuel usage, decreasing capital costs by replacing redundant diesel generation units, and increasing generator system life by shortening yearly runtime. Fast-acting battery energy storage systems with grid-forming inverters might have potential for improving drastically the reliability indices of isolated communities currently supplied by diesel generation. Abstract This paper will highlight unique challenges and opportunities with regard to energy storage utilization in remote, self-sustaining communities. The energy management of such areas has unique concerns. Diesel generation is often the go-to power source in these scenarios, but these systems are not devoid of issues. Without dedicated maintenance crews as in large, interconnected network areas, minor interruptions can be frequent and invasive not only for those who lose power, but also for those in the community that must then correct any faults. Although the immediate financial benefits are perhaps not readily apparent, energy storage could be used to address concerns related to reliability, automation, fuel supply concerns, generator degradation, solar utilization, and, yes, fuel costs to name a few. These ideas are shown through a case study of the Levelock Village of Alaska. Currently, the community is faced with high diesel prices and a difficult supply chain, which makes temporary loss of power very common and reductions in fuel consumption very impactful. This study will investigate the benefits that an energy storage system could bring to the overall system life, fuel costs, and reliability of the power supply. The variable efficiency of the generators, impact of startup/shutdown process, and low-load operation concerns are considered. The technological benefits of the combined system will be explored for various scenarios of future diesel prices and technology maintenance/replacement costs as well as for the avoidance of power interruptions that are so common in the community currently. Graphic abstract Discussion In several cases, energy storage can provide a means to promote energy equity by improving remote communities’ power supply reliability to levels closer to what the average urban consumer experiences at a reduced cost compared to transmission buildout. Furthermore, energy equity represents a hard-to-quantify benefit achieved by the integration of energy storage to isolated power systems of under-served communities, which suggests that the financial aspects of such projects should be questioned as the main performance criterion. To improve battery energy storage system valuation for diesel-based power systems, integration analysis must be holistic and go beyond fuel savings to capture every value stream possible.

25 ENERGY STORAGE↗

Multilevel Analysis, Design, and Modeling of Coupling Advanced Nuclear Reactors and Thermal Energy Storage in an Integrated Energy System

This report discusses the different options for coupling thermal energy storage (TES) systems to advanced nuclear power plants (A-NPPs) in order to enable flexible and hybrid plant operation. An advanced light-water reactor (A LWR), a high-temperature gas-cooled reactor (HTGR) and a liquid-metal fast reactor (LMFR) were selected as the initial use cases for demonstrating a thermally balanced energy storage coupling design for thermal power extraction. The models presented herein showcase several design considerations, focusing on optimal deployment methodologies for achieving steady-state and transient-state operation with minimum disruption to the nuclear power cycle. This first part of the study presents steady-state models developed using Aspen HYSYS®, with the thermal energy bypass for NPP-TES coupling being varied at up to 50%. The various components were sized using the Aspen Process Economic Analyzer (APEA) and Aspen Exchanger Design and Rating (EDR), when applicable. Cost functions from these models were developed using the latest publicly available data obtained from APEA V11. The TES-coupled A-NPP steady-state models and cost functions then provided a baseline for dynamic operation and process optimization by using Idaho National Laboratory (INL)’s Framework for Optimization of Resources and Economics (FORCE) tools. A stochastic optimization of the various energy storage systems coupled to the A-NPPs was then performed using the Risk Analysis Virtual Environment (RAVEN) and its dispatch optimization plugin, the Holistic Energy Resource Optimization Network (HERON). The signal processing and synthetic history capabilities of RAVEN were used to account for the unpredictable behavior of electricity markets. An autoregressive moving average (ARMA) model was used to analyze price signals from the Pennsylvania-New Jersey-Maryland (PJM) market and were applied to the HERON analysis in order to optimize a system with the best economics. Transient modeling evaluation was then performed using Modelica models within the HYBRID repository, which was developed at INL for the Department of Energy Integrated Energy Systems program for the characterization of dynamic integrated system behavior and feedback. This includes evaluation of the TES-coupled A-LWR systems’ impact on physical and thermal system response during imposed system demands. Additional TES-coupled reactor types, coupling approaches, markets, and TES technologies will be evaluated in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Market-Integrated Optimization of Wind-Battery-Hydrogen Hybrids for Peaking Capacity via Storage

As Integrated Energy Systems (IES) combine multiple energy and storage technologies to provide potentially more value and less risk via resource diversification, complementary overbuild, increased flexibility, and revenue-stacking, IES value is dependent on electricity market dispatch and grid interactions should play an important role in IES design and operation. This study hybridizes and retrofits wind and combustion turbine plants to study the impacts of replacing gas generation capacity with wind, battery, PEM electrolysis, hydrogen tanks and hydrogen turbines. The optimized design is co-simulated in a production cost model with different bidding strategies in order to compare performance and highlight the importance of grid-interactions. We analyze the revenue and dispatch changes as well as the price and cost implications of wind-battery-hydrogen IESs.

electrolysis↗

Long-Duration Energy Storage Grid Integration-Valuation Framework and Incentive Gaps

Given these challenges and current modeling gaps on Long Duration Energy Storage (LDES), enhancing the structure and design of existing planning, operations, and organized wholesale markets can better characterize the value of LDES to the power system. To more thoroughly assess the gaps and barriers to LDES investment and readiness for integration into a future grid, we conducted stakeholder outreach through an online survey, interviews with individual independent system operators/regional transmission organizations, and a literature review. Based on this assessment, we identified a set of opportunities for LDES focused development, including a framework to quantify the contributions of LDES on resource adequacy, reliability, and resiliency. Specifically, we identify the potential demand for and benefits of an open-source, LDES-centric evaluation framework that can guide future planning, operations, market design, and policy reforms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simultaneous Design and Operation of a Coal-Fired Hybrid Energy System with Integrated Thermal Energy Storage

This final report describes novel capabilities developed as part of DISPATCHES, Design Integration and Synthesis Platform to Advance Tightly Coupled Hybrid Energy Systems, for designing hybrid energy systems (HES) a.k.a. integrated energy systems (IES) in the context of a larger electricity market. Capabilities are demonstrated on a case study with fossil-based power coupled to a molten salt thermal energy storage system.

20 FOSSIL-FUELED POWER PLANTS↗