Search NASA⌕ Search

SEARCH · Search NASA

Results for “integrating sphere”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Radiation sensitive area detection device and method

A radiation sensitive area detection device for use in conjunction with an X ray, ultraviolet or other radiation source is provided which comprises a phosphor containing film which releases a stored diffraction pattern image in response to incoming light or other electromagnetic wave. A light source such as a helium-neon laser, an optical fiber capable of directing light from the laser source onto the phosphor film and also capable of channelling the fluoresced light from the phosphor film to an integrating sphere which directs the light to a signal processing means including a light receiving means such as a photomultiplier tube. The signal processing means allows translation of the fluoresced light in order to detect the original pattern caused by the diffraction of the radiation by the original sample. The optical fiber is retained directly in front of the phosphor screen by a thin metal holder which moves up and down across the phosphor screen and which features a replaceable pinhole which allows easy adjustment of the resolution of the light projected onto the phosphor film. The device produces near real time images with high spatial resolution and without the distortion that accompanies prior art devices employing photomultiplier tubes. A method is also provided for carrying out radiation area detection using the device of the invention.

Carter, Daniel C.↗

Phosphor Scanner For Imaging X-Ray Diffraction

Improved optoelectronic scanning apparatus generates digitized image of x-ray image recorded in phosphor. Scanning fiber-optic probe supplies laser light stimulating luminescence in areas of phosphor exposed to x rays. Luminescence passes through probe and fiber to integrating sphere and photomultiplier. Sensitivity and resolution exceed previously available scanners. Intended for use in x-ray crystallography, medical radiography, and molecular biology.

Carter, Daniel C.↗

Spacecraft thermal control coatings

The Experiment AO 138-6 was located on the trailing edge of the Long Duration Exposure Facility as part of the French Cooperative Payload (FRECOPA) Experiment. It was purely passive in nature: material specimens 2 x 2 cm, independently mounted in sample-holders, with their surface in the same reference plane, were exposed to space. Thirty samples were set in a vacuum-tight canister which was opened in space a few days after LDEF deployment and closed while still in orbit ten months later; twenty-four samples were directly exposed to space for the total flight duration (preflight handling, shuttle bay environment, separation from shuttle, shuttle environment, LEO environment, docking, descent, transfer to KSC). Materials included paints (conductive or nonconductive), SSM's, polymeric films, surface coatings, composite materials, and metals. After sample retrieving, inspection and measurements were carried out in atmospheric laboratory conditions on each sample: observation with binocular lenses and scanning electron microscopy, spectral relectance and transmittance using an integrating sphere in the wavelength range 280-2300 nm, emissivity by the means of a Gier & Dunkle portable reflectometer, electron spectroscopy for chemical analysis-x-ray photoelectron spectroscopy (ESCA-XPS), and Rutherford backscattering spectroscopy (RBS) measurements on some selected samples. The results obtained from flight were compared to laboratory data obtained in UV-irradiation tests when these data were available. As a general statement a good spectral concordance is observed for all samples not in the canister so long as air recoveries are taken into account. For one material, the degradation is more important for the sample in the canister than for those of the same material mounted at the surface of the tray; for most samples in the canister the degradation is slightly higher than the one which can be predicted from laboratory standard irradiations. Contamination problems having been ruled out, the higher temperature experience by the samples on the inside of canister probably explains these phenomena.

Guillaumon, Jean-Claude↗

Radiometric properties of the NS001 Thematic Mapper Simulator aircraft multispectral scanner

Laboratory tests of the NS001 TM are described emphasizing absolute calibration to determine the radiometry of the simulator's reflective channels. In-flight calibration of the data is accomplished with the NS001 internal integrating-sphere source because instabilities in the source can limit the absolute calibration. The data from 1987-89 indicate uncertainties of up to 25 percent with an apparent average uncertainty of about 15 percent. Also identified are dark current drift and sensitivity changes along the scan line, random noise, and nonlinearity which contribute errors of 1-2 percent. Uncertainties similar to hysteresis are also noted especially in the 2.08-2.35-micron range which can reduce sensitivity and cause errors. The NS001 TM Simulator demonstrates a polarization sensitivity that can generate errors of up to about 10 percent depending on the wavelength.

Markham, Brian L.↗

Next generation optical instruments and space experiment based on the LDEF thermal control surfaces experiment (S0069)

The Thermal Control Surfaces Experiment (TCSE) was a successful experiment to study the effects of the space environment on thermal control surfaces using in-space optical properties measurements combined with post-flight analyses. The TCSE reflectometer performed well on the LDEF mission demonstrating that a portable compact integrating sphere spectroreflectometer can be built that is rugged and space rated. Since the retrieval of the TCSE package from space, several other instruments have evolved from its pioneering technologies. These are the Optical Properties Monitor (OPM), the Laboratory Portable SpectroReflectometer (LPSR), and the Space Portable SpectroReflectometer (SPSR). These instruments and experiment packages are described.

Wilkes, Donald R.↗

Radiometric calibration of an airborne multispectral scanner

The absolute radiometric calibration of the NS001 Thematic Mapper Simulator reflective channels was examined based on laboratory tests and in-flight comparisons to ground measurements. The NS001 data are calibrated in-flight by reference to the NS001 internal integrating sphere source. This source's power supply or monitoring circuitry exhibited greater instability in-flight during 1988-1989 than in the laboratory. Extrapolating laboratory behavior to in-flight data resulted in 7-20 percent radiance errors relative to ground measurements and atmospheric modeling. Assuming constancy in the source's output between laboraotry and in-flight resulted in generally smaller errors. Upgrades to the source's power supply and monitoring circuitry in 1990 improved its in-flight stability, though in-flight ground reflectance based calibration tests have not yet been performed.

Markham, Brian L.↗

In-flight radiometry of an airborne multispectral sensor

The in-flight radiometric behavior of the NS001 Landsat Thematic Mapper simulator is being reexamined. The absolute radiometric calibration and polarization sensitivity are being analyzed based on data collected in 1990 and 1991. The NS001 has continuously variable gain settings controlled by the aircraft operator. As such, the of in-flight calibration source, an integrating sphere in the solar reflective spectrum, is the only means for calibrating this instrument. Upgrades to the power supply and monitoring circuitry in 1990 improved the in-flight stability. Preliminary results in-flight calibrations of the NS001 indicate no improvement in radiometric accuracy. Laboratory tests have also shown that the NS001 shows strong sensitivity to the degree of polarization and state of the incoming radiations. Simulation studies for typical in-flight conditions have shown that for the NS001 scanning in the principal plane of the sun over a vegetated target, radiance errors reached +/-10 percent in the 0.45-0.52-micron channel and varied with scan angle.

Markham, Brian L.↗

An almost 'perfectly' diffuse, 'perfect' reflector for far-infrared reflectance calibration

Specular and diffuse reflectance measurements made near normal incidence of two very rough, solid aluminum surfaces are presented for the wavelength range from 2.2 to 512 microns. The diffuse measurements made at nonspecular angles by two different detectors indicate that between 33 and 201 microns the reflectance of one surface is nearly Lambertian (isotropic) with a bidirectional reflectance distribution function (BRDF) value within 32 percent of the theoretical value of (1/pi)/sr for a perfectly diffuse, perfect reflector. Photometric reflectance spectra at the specular angle show that between 6.9 and 100 microns the specular BRDF of these surfaces is within 5 percent of the theoretical value of (1/pi)/sr. At longer wavelengths of 235, 320, and 512 microns the specular reflectance rapidly departs from that of a perfectly diffuse, perfect reflector. The two samples studied have rms surface roughnesses of 44 and 60 microns. A durable metal surface with these near perfect reflectance characteristics can be advantageously used in the FIR as a black-body source, the interior surface of an integrating sphere, and most especially as an absolute calibration standard. BRDF measurements at 40 deg incidence, though still highly diffuse, show a significant departure from Lambertian reflectance.

Smith, Sheldon M.↗

MODIS airborne simulator visible and near-infrared calibration, 1992 ASTEX field experiment. Calibration version: ASTEX King 1.0

Calibration of the visible and near-infrared (near-IR) channels of the MODIS Airborne Simulator (MAS) is derived from observations of a calibrated light source. For the 1992 Atlantic Stratocumulus Transition Experiment (ASTEX) field deployment, the calibrated light source was the NASA Goddard 48-inch integrating hemisphere. Tests during the ASTEX deployment were conducted to calibrate the hemisphere and then the MAS. This report summarizes the ASTEX hemisphere calibration, and then describes how the MAS was calibrated from the hemisphere data. All MAS calibration measurements are presented and determination of the MAS calibration coefficients (raw counts to radiance conversion) is discussed. In addition, comparisons to an independent MAS calibration by Ames personnel using their 30-inch integrating sphere is discussed.

Arnold, G. Thomas↗

MODIS airborne simulator visible and near-infrared calibration, 1991 FIRE-Cirrus field experiment. Calibration version: FIRE King 1.1

Calibration of the visible and near-infrared channels of the MODIS Airborne Simulator (MAS) is derived from observations of a calibrated light source. For the 1991 FIRE-Cirrus field experiment, the calibrated light source was the NASA Goddard 48-inch integrating hemisphere. Laboratory tests during the FIRE Cirrus field experiment were conducted to calibrate the hemisphere and from the hemisphere to the MAS. The purpose of this report is to summarize the FIRE-Cirrus hemisphere calibration, and then describe how the MAS was calibrated from observations of the hemisphere data. All MAS calibration measurements are presented, and determination of the MAS calibration coefficients (raw counts to radiance conversion) is discussed. Thermal sensitivity of the MAS visible and near-infrared calibration is also discussed. Typically, the MAS in-flight is 30 to 60 degrees C colder than the room temperature laboratory calibration. Results from in-flight temperature measurements and tests of the MAS in a cold chamber are given, and from these, equations are derived to adjust the MAS in-flight data to what the value would be at laboratory conditions. For FIRE-Cirrus data, only channels 3 through 6 were found to be temperature sensitive. The final section of this report describes comparisons to an independent MAS (room temperature) calibration by Ames personnel using their 30-inch integrating sphere.

Arnold, G. Thomas↗

SeaWiFS technical report series. Volume 16: The second SeaWiFS Intercalibration Round-Robin Experiment, SIRREX-2, June 1993

The results of the second Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-2), which was held at the Center for Hydro-Optics and Remote Sensing (CHORS) at San Diego State University on 14-25 Jun. 1993 are presented. SeaWiFS is an ocean color radiometer that is scheduled for launch in 1994. The SIRREXs are part of the SeaWiFS Calibration and Validation Program that includes the GSFC, CHORS, NIST, and several other laboratories. GSFC maintains the radiometric scales (spectral radiance and irradiance) for the SeaWiFS program using spectral irradiance standards lamps, which are calibrated by NIST. The purpose of each SIRREX is to assure that the radiometric scales which are realized by the laboratories who participate in the SeaWiFS Calibration and Validation Program are correct; that is, the uncertainties of the radiometric scales are such that measurements of normalized water-leaving radiance using oceanographic radiometers have uncertainties of 5%. SIRREX-1 demonstrated, from the internal consistency of the results, that the program goals would not be met without improvements to the instrumentation. The results of SIRREX-2 demonstrate that spectral irradiance scales realized using the GSFC standard irradiance lamp (F269) are consistent with the program goals, as the uncertainty of these measurements is assessed to be about 1%. However, this is not true for the spectral radiance scales, where again the internal consistency of the results is used to assess the uncertainty. This is attributed to inadequate performance and characterization of the instrumentation. For example, spatial nonuniformities, spectral features, and sensitivity to illumination configuration were observed in some of the integrating sphere sources. The results of SIRREX-2 clearly indicate the direction for future work, with the main emphasis on instrument characterization and the assessment of the measurement uncertainties so that the results may be stated in a more definitive manner.

Hooker, Stanford B.↗

Surface characterization and contamination analysis

The research activity for this first year has focussed on three distinct activities: (1) the use of an integrating sphere to improve upon the gathering of spectral data from a variety of surfaces; (2) the use of optical fiber spectrometry to determine levels of contamination from tape residues on critical bonding surfaces; and (3) an exploratory activity in the use of spectroscopic ellipsometry for the analysis of thin films of contaminants on critical surfaces has also begun.

Workman, Gary L.↗

Application of a two-stream radiative transfer model for leaf lignin and cellulose concentrations from spectral reflectance measurements, part 1

Lignin and nitrogen contents of leaves constitute the primary rate-limiting parameters for the decomposition of forest litter, and are determinants of nutrient- and carbon-cyclic rates in forest ecosystems (Melillo et al., 1982). Wessman et al. (1988a) developed empirical multivariate relationships between forest canopy lignin amount and the (first-difference) AIS spectral response in three bands spread over the wavelength interval 1256-1555 nm. Wessman et al. (1988b) and McLellan et al. (1991) developed similar regression relationships from laboratory reflectance measurements on dried samples prepared in a standard fashion. They used four to six infrared bands for analysis of nitrogen, lignin and cellulose content of foliage in forest and prairie species. In the present article (Parts 1 and 2) the feasibility of compositional determinations is explored using positions of composite absorption bands that originate from mixtures of lignin, cellulose, and possibly other chemical constituents in the spectral reflectance of green leaves. To carry out this program, we employ full-spectral-resolution single-leaf diffuse reflectance measurements made with a laboratory spectrometer and integrating sphere. The leaf and other chemical reflectance data compiled by Elvidge (1990) have also been utilized extensively.

Conel, James E.↗

Leaf absorbance and photosynthesis

The absorption spectrum of a leaf is often thought to contain some clues to the photosynthetic action spectrum of chlorophyll. Of course, absorption of photons is needed for photosynthesis, but the reverse, photosynthesis when there is absorption, is not necessarily true. As a check on the existence of absorption limits we measured spectra for a few different leaves. Two techniques for measuring absorption have been used, viz. the separate determination of the diffuse reflectance and the diffuse transmittance with the leaf at a port of an integrating sphere and the direct determination of the non-absorbed fraction with the leaf in the sphere. In a cross-check both methods yielded the same results for the absorption spectrum. The spectrum of a Fuchsia leaf, covering the short-wave region from 350 to 2500 nm, shows a high absorption in UV, blue and red, the well known dip in the green and a steep fall-off at 700 nm. Absorption drops to virtually zero in the near infrared, with subsequent absorptions, corresponding to the water absorption bands. In more detailed spectra, taken at 5 nm intervals with a 5 nm bandwidth, differences in chlorophyll content show in the different depths of the dip around 550 nm and in a small shift of the absorption edge at 700 nm. Spectra for Geranium (Pelargonium zonale) and Hibiscus (with a higher chlorophyll content) show that the upper limit for photosynthesis can not be much above 700 nm. No evidence, however, is to be seen of a lower limit for photosynthesis and, in fact, some experiments down to 300 nm still did not show a decrease of the absorption although it is well recognized that no photosynthesis results with 300 nm wavelengths.

Schurer, Kees↗

SeaWiFs Technical Report Series. Volume 34: The Third SeaWiFS Intercalibration Round-Robin Experiment (SIRREX-3), 19-30 September 1994

This report presents results of the third Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round- Robin Experiment (SIRREX-3), which was held at the San Diego State University (SDSU) Center for Hydro-Optics and Remote Sensing (CHORS) on 19-30 September 1994. Spectral irradiances of FEL lamps belonging to each participant were intercompared by reference to the National Institute of Standards and Technology (NIST) scale of spectral irradiance using secondary standard lamps F268, F269, and F182, with a Type A uncertainty between 1.1-1.5%. This level of uncertainty was achieved despite difficulties with lamp F269. The average spectral irradiances of FEL lamps, compared in both SIRREX-2 and SIRREX-3, differed between the two experiments by 1.5%, which probably indicates that the values assigned to the secondary standard lamp at the time of SIRREX-2 were in error. With two exceptions, spectral radiance values of integrating sphere sources were measured during SIRREX-3 with uncertainties in temporal stability of less than 0.3% and absolute uncertainties of 1.5-2.0%. This is a significant improvement over similar intercomparisons in SIRREX- I and SIRREX-2. Plaque reflectances were intercompared with an uncertainty of about 1-2%, but the absolute uncertainty is undefined. Although this is an improvement over results of previous SIRREXS, the sources and magnitude of uncertainty associated with transfers of spectral radiance using plaques requires further evaluation in future experiments.

Hooker, Stanford B.↗

GOME Calibration and Validation Using Backscatter UV Techniques

GOME radiance, irradiance, and ozone products were validated by NASA Goddard Space Flight Center through three tasks which included, pre-launch calibration comparisons with SBUV and TOMS radiometric standards, validation of GOME Level-1 irradiance and radiance and Level 2 total ozone data products using SBUV/2 and TOMS algorithms and data, and studies of GOME data using the Goddard radiative transfer code. The prelaunch calibration using the NASA large aperture integrating sphere was checked against that provided by TPD. Agreement in the calibration constants, derived in air, between the Goddard and TPD system were better than 3%. Validation of Level-1 irradiance data included comparison of GOME and SSBUV and the UARS solar irradiances measurements. Large wavelength dependent differences, as high as 10%, were noted between GOME and the US instruments. This discrepancy has now been attributed to radiometric sensitivity changes experienced by GOME when operating in a vacuum. GOME Earth radiance data were then compared to the NOAA-14 SBUV/2 radiances. These results show that between 340 and 400 nm the differences in GOME and SBUV/2 data are less than 5% with some wavelength dependence. At wavelengths shorter than 300 nm, differences are of the order of 10% or more where the GOME radiances are larger. To test GOME DOAS retrieved total ozone values, these values were compared with ozone amounts retrieved using GOME radiances in the TOMS version-7 algorithm. The differences showed a solar zenith angle dependence ranging from 0 to 10% where the TOMS algorithm values were higher. GOME radiances below 300 nm were further validated by selecting radiances at wavelengths normally used by SBUV and processing them through the SBUV ozone profile algorithm and then compared to climatological values. The GOME ozone profiles ranged from 10-30% lower over altitude compared to climatological values. This is consistent with the offsets detected in the SBUV/2 radiance comparisons at wavelengths shorter than 300 nm.

Hilsenrath, E.↗

Study of SRM Critical Surfaces Using Near Infrared Optical Fiber Spectrometry

The measurement and control of cleanliness for critical surfaces during manufacturing and in service operations provides a unique challenge in the current thrust for environmentally benign processes. Of particular interest has been work performed in maintaining quality in the production of bondline surfaces in propulsion systems and the identification of possible contaminants which are detrimental to the integrity of the bondline. This work requires an in-depth study of the possible sources of contamination, methodologies to identify contaminants, discrimination between contaminants and chemical species caused by environment, and the effect of particular contaminants on the bondline integrity of the critical surfaces. This paper will provide an introduction to the use of Near Infrared (NIR) optical fiber spectrometry in a nondestructive measurement system for process monitoring and how it can be used to help clarify issues concerning surface chemistry. In a previous conference, experimental results for quantitative measurement of silicone and Conoco HD2 greases, and tape residues on solid rocket motor surfaces were presented. This paper will present data for metal hydroxides and discuss the use of the integrating sphere to minimize the effects of physical properties of the surfaces (such as surface roughness) on the results obtained from the chemometric methods used for quantitative analysis.

Workman, G. L.↗

SeaWiFS Postlaunch Technical Report Series: The 1997 Prelaunch Radiometric Calibration of SeaWiFS - Volume 4

The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) was originally calibrated by the instrument's manufacturer, Santa Barbara Research Center (SBRC), in November 1993. In preparation for an August 1997 launch, the SeaWiFS Project and the National Institute of Standards and Technology (NIST) undertook a second calibration of SeaWiFS in January and April 1997 at the facility of the spacecraft integrator, Orbital Sciences Corporation (OSC). This calibration occurred in two phases, the first after the final thermal vacuum test, and the second after the final vibration test of the spacecraft. For the calibration, SeaWiFS observed an integrating sphere from the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) at four radiance levels. The spectral radiance of the sphere at these radiance levels was also measured by the SeaWiFS Transfer Radiometer (SXR). In addition, during the calibration, SeaWiFS and the SXR observed the sphere at 16 radiance levels to determine the linearity of the SeaWiFS response. As part of the calibration analysis, the GSFC sphere was also characterized using a GSFC spectroradiometer. The 1997 calibration agrees with the initial 1993 calibration to within +/- 4%. The new calibration coefficients, computed before and after the vibration test, agree to within 0.5%. The response of the SeaWiFS channels in each band is linear to better than 1%. In order to compare to previous and current methods, the SeaWiFS radiometric responses are presented in two ways: using the nominal center wave-lengths for the eight bands; and using band-averaged spectral radiances. The band-averaged values are used in the flight calibration table. An uncertainty analysis for the calibration coefficients is also presented.

Hooker, Stanford B.↗