Spin Squeezing with Itinerant Magnetic Dipoles

Entanglement can improve the measurement precision of quantum sensors beyond the shot noise limit. Neutral atoms, the basis of some of the most precise and accurate optical clocks and interferometers, do not naturally exhibit the all-to-all interactions traditionally used to generate such entangled states. On the other hand, these systems exhibit exceedingly high degrees of experimental control over parameters such as temperature, spatial entropy, and itinerancy. In this work, we investigate spin squeezing in a highly coherent itinerant system of neutral atoms with magnetic dipole-dipole interactions. We achieve 7.1 dB of metrologically useful squeezing using finite-range spin-exchange interactions in an erbium quantum gas microscope, and we demonstrate that introducing atomic motion, realizing a dipolar 𝑡−𝐽 model, protects the spin sector coherence at low fillings, significantly improving the achievable spin squeezing in a 2D dipolar system. This work’s protocol can be implemented with most neutral atoms, opening the door to quantum-enhanced metrology in other itinerant dipolar systems, such as molecules or optical lattice clocks, and serves as a novel method for studying itinerant quantum magnetism with long-range interactions.

Atomic, optical & lattice clocks↗

Detecting gravitational signatures of dark matter with atom gradiometers

We study the purely gravitational signatures of dark matter from the ultralight to the ultraheavy mass range in proposed long-baseline atom gradiometers, focusing on terrestrial designs, such as AION-km and MAGIS-km, as well as space-based concepts, such as MAGIS-space, AEDGE and AEDGE+. Due to its exceptional acceleration sensitivity and depending on astrophysical backgrounds, a detector similar to AEDGE+ could detect a dark matter subcomponent which constitutes 𝒪⁡(10%) of the local dark matter energy density and is populated by compact clumps of mass between 10 6 kg and 10 10 kg (10 −25 ⁢𝑀⊙ ≲ 𝑀 ≲10 −21⁢ 𝑀⊙) in an otherwise unexplored region of dark matter model space. Furthermore, because the gravitational observable depends on the relative gravitational time delay measured by spatially separated atomic clouds, we find that atom gradiometers are parametrically more sensitive than laser interferometers, such as LIGO and LISA, to fast-oscillating spacetime perturbations sourced by energy density and pressure fluctuations of ultralight dark matter. Depending on astrophysical backgrounds, a detector akin to AEDGE+ could probe a DM overdensity of 𝒪⁡(10) times the local dark matter energy density for masses 𝑚 ≲10 −17 eV.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling and Validation of Offset Cancellation for Hybrid Photonic-Electronic Transimpedance Amplifier Using All-Electronic Circuits

Hybrid photonic-electronic circuits involving crossdomain feedback signals are difficult to validate and troubleshoot. This paper describes an approach to model and validate an offset-cancellation loop for a hybrid transimpedance amplifier (TIA) using all-electronic circuits. An equivalent electrical model is developed for the tunable interferometer attenuators used for offset trimming, and it includes test features to extract the system performance. The stability analysis of the system shows 75 ◦ of phase margin and 102 dB of gain margin. Measurement results demonstrate good agreement with analysis and successful TIA offset cancellation.

Marchant, Jared↗

Terrestrial Very-Long-Baseline Atom Interferometry: summary of the second workshop

This summary of the second Terrestrial Very-Long-Baseline Atom Interferometry (TVLBAI) Workshop provides a comprehensive overview of our meeting held in London in April 2024 (Second Terrestrial Very-Long-Baseline Atom Interferometry Workshop, Imperial College, April 2024), building on the initial discussions during the inaugural workshop held at CERN in March 2023 (First Terrestrial Very-Long-Baseline Atom Interferometry Workshop, CERN, March 2023). Like the summary of the first workshop (Abend et al. in AVS Quantum Sci. 6:024701, 2024), this document records a critical milestone for the international atom interferometry community. It documents our concerted efforts to evaluate progress, address emerging challenges, and refine strategic directions for future large-scale atom interferometry projects. Our commitment to collaboration is manifested by the integration of diverse expertise and the coordination of international resources, all aimed at advancing the frontiers of atom interferometry physics and technology, as set out in a Memorandum of Understanding signed by over 50 institutions (Memorandum of Understanding for the Terrestrial Very Long Baseline Atom Interferometer Study).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicting ptychography probe positions using single-shot phase retrieval neural network

Ptychography is a powerful imaging technique that is used in a variety of fields, including materials science, biology, and nanotechnology. However, the accuracy of the reconstructed ptychography image is highly dependent on the accuracy of the recorded probe positions which often contain errors. These errors are typically corrected jointly with phase retrieval through numerical optimization approaches. When the error accumulates along the scan path or when the error magnitude is large, these approaches may not converge with satisfactory result. We propose a fundamentally new approach for ptychography probe position prediction for data with large position errors, where a neural network is used to make single-shot phase retrieval on individual diffraction patterns, yielding the object image at each scan point. The pairwise offsets among these images are then found using a robust image registration method, and the results are combined to yield the complete scan path by constructing and solving a linear equation. We show that our method can achieve good position prediction accuracy for data with large and accumulating errors on the order of 10 2 pixels, a magnitude that often makes optimization-based algorithms fail to converge. For ptychography instruments without sophisticated position control equipment such as interferometers, our method is of significant practical potential.

47 OTHER INSTRUMENTATION↗

Broadband rapid-scanning phase-modulated Fourier transform electronic spectroscopy

We present a phase-modulated approach for ultrabroadband Fourier transform electronic spectroscopy. To overcome the bandwidth limitations and spatial chirp introduced by acousto-optic modulators (AOMs), pulses from a 1 µm laser are modulated using AOMs prior to continuum generation. This phase modulation is transferred to the continuum generated in a yttrium aluminum garnet crystal. Separately generated phase-modulated continua in two arms of a Mach-Zehnder interferometer interfere with the difference of their modulation frequencies, enabling physical under-sampling of the signal and the suppression of low-frequency noise. By interferometrically tracking the relative time delay of the continua, we perform continuous, rapid-scanning Fourier transform electronic spectroscopy with a high signal-to-noise ratio and spectral resolution. As proof of principle, we measure the linear absorption and fluorescence excitation spectra of a laser dye and various biological samples.

Javed, Ariba↗

Automated tuning of a ring-assisted MZI-based interleaver for Kerr frequency combs

We demonstrate a compact ring-assisted Mach–Zehnder interferometer (RAMZI)-based silicon photonic interleaver with a 400 GHz free spectral range (FSR), featuring flat passbands exceeding a spectral range of 50 nm. Additionally, we introduce a novel, to the best of our knowledge, add-on structure and tuning method enabling automated compensation for fabrication imperfections, precise shaping of the RAMZI flat-top passbands, and alignment with Kerr comb lines. Experimental results have shown successful interleaving of eight channels of distributed-feedback (DFB) lasers as well as a 200 GHz Kerr comb, both achieving an extinction ratio of approximately 20 dB.

Wang, Songli (ORCID:0009000626380795)↗

Single-shot spatiotemporal plasma density measurements with a chirped probe pulse

In this work, we present the development and demonstration of a diagnostic for the measurement of the spatial and temporal evolution of plasma density in a single shot. Single-shot Advanced Plasma Probe HolographIc REconstruction (SAPPHIRE) utilizes a chirped probe pulse, a diffractive optical element, a self-referenced interferometer, and an interference bandpass filter to achieve high-fidelity electron density measurements suitable for underdense plasmas that exhibit cylindrical symmetry. The method overcomes limitations in conventional diagnostics, such as reliance on shot-to-shot reproducibility, while capturing plasma dynamics on picosecond timescales with micron-level spatial resolution. The capabilities of SAPPHIRE are demonstrated through measurements of laser-driven plasma channels in helium–nitrogen gas jets. SAPPHIRE demonstrates the formation and expansion of plasma channels in a single shot and the propagation of supersonic ionization fronts while revealing shot-to-shot variations in the plasma profiles. Experimental results are validated against theoretical models and scaling laws, underscoring the robustness and accuracy of this technique. By enabling ultrafast, high-resolution plasma diagnostics in a single exposure, SAPPHIRE represents a transformative advancement in plasma measurement technology.

Grace, Elizabeth S. [Lawrence Livermore National L↗

Towards Cluster State Generation with Spatial Modes

We leverage spatial modes to generate multipartite entangled states in a cross-coupled SU(1,1) interferometer with intensity-difference squeezing of 4.2 dB. Theoretical analysis shows that the generated state can be converted to a cluster state.

Leger, Zacharie [ORNL] (ORCID:0000000179044775)↗

Pilot-Scale Validation of Distributed Optical Fiber Sensors for Underground Pipeline Monitoring

Monitoring parameters such as hoop strain, pressure, and acoustic vibrations is key to detecting potential leaks, intrusions, or structural issues. Distributed optical fiber sensor (DOFS) systems provide a compelling solution for continuous, real-time monitoring over long distances. This paper details the development and pilot-scale implementation of DOFS systems for underground pipeline monitoring, evolving from a proof-of-concept stage. Multiple custom-designed DOFS interrogator units—such as optical frequency-domain reflectometry (OFDR), Brillouin optical time-domain analysis (BOTDA), and multimodal interferometer-based fiber acoustic sensor systems were tested to measure the key parameters, such as hoop strain, pipe pressure, surrounding soil temperature, and acoustic vibrations. The underground product pipeline’s outer diameter is 30 inches, the wall thickness is 1.28 inches, and 3 feet deep from the surface. The fiber deployment strategies and sensing data acquisition methods for these systems are discussed. The results demonstrate the effectiveness of DOFS in detecting hoop strain, temperature changes, and acoustic vibrations, showcasing their potential for real-time monitoring and enhancing pipeline safety. These findings from pilot-scale testing offer valuable insights into advancing pipeline monitoring technologies and improving the reliability of underground pipeline systems.

fiber optic sensors↗

Frequency-Selectable Laser Source (FLS) Calibrator for CMB Bandpass Characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from our detector bandpass calibration. Uncertainties in bandpass can severely limit our measurements by limiting foreground removal and spectral fitting, which is particularly important for high-$\ell$ observations like cluster science using the Sunyaev-Zeldovich (SZ) effect. Currently, CMB experiments typically use a Fourier Transform Spectrometer (FTS) to measure the detector bandpasses. However, the resolution of the FTS is dependent on the length of the interferometer arms, leading to a need for increasingly large FTS instruments as CMB experiments require tighter constraints on detector bandpasses. Additionally, systematic effects like shifts in bandpass shape from uneven illumination from the FTS further limit the calibration uncertainties. As a complement to the FTS, we have developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency housed in a calibrator that allows for varying degrees of laser power attenuation. We present several tests used to characterize the first prototype design of the FLS calibrator, as well as the improvements to the calibrator design currently underway.

Saunders, Lauren [Fermilab]↗

Infrared Cloud Imager Instrument Intercomparison Report

The Infrared Cloud Imager Instrument Intercomparison was a guest instrument deployment by NWB Sensors to the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) User Facility observatory on the Southern Great Plains (SGP) between May 18 and December 12, 2023. NWB Sensors is a company that has developed a commercially available infrared cloud imager (ICI). The ICI provides radiometrically calibrated, full-sky images of the downwelling infrared radiance in the 7.3-14 µm band. In addition, it provides cloud radiance as the residual between the observed radiance and the modeled cloud-free radiance as well as derived cloud products. The instrument is used in applications that require consistent detection of clouds across day and night. For more information, consult the instrument's webpage. The primary goal of the deployment was to validate the radiometric accuracy of the ICI. The ICI uses a proprietary calibration method to convert the raw data from its infrared camera into downwelling radiance. Unlike similar instruments, the system does not have an onboard blackbody calibration standard. Instead, NWB Sensors characterizes each ICI camera individually in an environmental chamber while looking at a blackbody standard. The resulting (proprietary) calibration is used operationally in the instrument and has been demonstrated to be stable over long periods. To validate the radiometric products from the ICI, an intercomparison between the ICI data products and those from ARM’s atmospheric emitted radiance interferometer (AERI) was made. The AERI is a best-in-class instrument for measuring downwelling infrared radiance (Gero et al. 2025). A weighted integration of the AERI’s spectral radiances across the ICI’s camera response was performed. The resulting radiance (herein called the AERI radiance) was directly compared to the zenith radiance concurrently observed by the ICI. The results of these comparisons are reported in the next section of this report.

54 ENVIRONMENTAL SCIENCES↗

Southern Hemisphere Polar Infrared Radiation Experiment (SHIRE) Field Campaign Report

An extended-range atmospheric emitted radiance interferometer (AERI) instrument to be deployed to Scott Base (78 S, 166 E) in McMurdo Sound, Antarctica for the purpose of synergizing with the National Aeronautics and Space Administration (NASA) Polar Radiant Energy in the Far-InfraRed Experiment (PREFIRE) satellite mission (https://prefire.ssec.wisc.edu/), examining the closure of atmospheric thermal emission, and providing validation for PREFIRE. The PREFIRE mission is the first satellite mission to map Earth’s spectrally resolved thermal emission, from 5 to 50 microns, over seasonal to annual timescales. These new observations represent the beginning of an intensive examination of the nature of thermal emission from Earth (emission from both the surface and atmosphere). A primary requirement of the PREFIRE mission is to provide validation of the retrieved variables. Numerous field sites in the Arctic (such as the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) North Slope of Alaska observatory and Summit Station, Greenland) have existing instrumentation to facilitate validation, leaving an observational gap in Antarctica. Through SHIRE, we propose to establish a temporary, intensive measurement site in Antarctica to ensure that both poles are suitably represented, and benefit from this state-of-the art science. This will also allow Arctic and Antarctic atmospheric radiative states to be compared and contrasted. For SHIRE specifically, we also propose further objectives to examine the spectrally resolved thermal radiative closure of the polar atmosphere and the historical changes in Antarctic radiative forcing, using previous Antarctic field campaigns, such as the ARM West Antarctic Radiation Experiment (AWARE).

54 ENVIRONMENTAL SCIENCES↗

Planetary Boundary-Layer Height (PBLHT) Value-Added Product: Remote-Sensing Retrievals

The planetary boundary layer (PBL) is fundamental to numerous atmospheric processes, including aerosol mixing and transport, cloud evolution, and precipitation formation. A critical parameter in these studies is the PBL height (PBLHT). This vertical depth is essential for characterizing PBL structures in numerical simulations and serves as a primary metric for estimating flux exchanges between the Earth’s surface and the atmosphere. Radiosonde (SONDE) observations provide high-vertical-resolution measurements of temperature and moisture profiles and are widely used to estimate PBLHT (Liu and Liang 2010, Seidel et al. 2010). The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s PBLHT value-added product (VAP) for radiosonde measurements, known as PBLHTSONDE, applies three commonly used methods—the Heffter (1980) method, the Liu and Liang (2010) method, and the bulk Richardson number approach (Seibert et al. 2000)—to derive PBLHT. The PBLHTSONDE VAP operates routinely at ARM observatories and mobile facilities, with data available from the ARM Data Center shortly after sounding observations are collected (Sivaraman et al. 2013). However, radiosonde observations are limited by their low temporal resolution. Most stations launch soundings only twice daily, which constrains the ability to investigate and characterize the temporal evolution of the PBL using radiosonde data alone. The use of continuous remote-sensing observations provides high temporal resolution of PBLHT estimates. These observations include aerosol lidars (Dang et al. 2019, Su et al. 2020), Doppler lidar (DL; Tucker et al. 2009, Krishnamurthy et al. 2021), and water vapor and/or temperature lidars and radiometers (Turner et al. 2014). These observations provide valuable data on the PBL’s thermodynamic properties (e.g., water vapor and/or temperature lidars and radiometers), dynamic properties (e.g., DL), and distribution of tracer substances (e.g., aerosol lidars), all of which can be used to estimate PBLHT. ARM developed PBLHT estimates from the micropulse lidar (MPL; PBLHTMPL), Doppler lidar (PBLHTDL), and combined Raman lidar (RL)/atmospheric emitted radiance interferometer (AERI) thermodynamic profiles (PBLHTTHERMO). Each estimate captures different physical characteristics of the boundary layer—aerosol tracers, vertical velocity turbulence, and thermodynamic structure—and exhibits distinct strengths and limitations depending on the PBL regime and time of day. In addition, the ARM ceilometer (CEIL) provides three potential PBLHT candidates derived from the vendor's built-in algorithm. Building on these individual retrievals, ARM developed the PBLHTBEML VAP, which combines the four remote-sensing-based estimates with ancillary meteorological variables using the machine learning approach of Zhang et al. (2025) to produce a best-estimate PBLHT at 10-minute resolution.

54 ENVIRONMENTAL SCIENCES↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

Magnetic Mapping of MAGIS-100 Tubes to Guide Experimental Redesign

The MAGIS-100 atom interferometer requires an exceptionally uniform, low-magnetic-field environment along its 100-meter baseline. While characterization of the raw structural tubes established a clean baseline, the original surrounding experimental design proved overly complex, ultimately introducing complications that degraded data precision. To resolve these systemic issues, a comprehensive redesign of the surrounding apparatus is underway. This poster details our magnetometry data collection efforts on the baseline tubes and highlights how these measurements are being used to guide a streamlined external design. By leveraging this background data, the new configuration aims to eliminate the complexities of the initial setup and ensure the environmental stability required for high-precision quantum sensing.

Savoia Cooley, Patricia [North Central Coll.]↗