Search NASA⌕ Search

SEARCH · Search NASA

Results for “interferometer calibrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Three-dimensional measurements of plasma parameters in an inductively coupled plasma processing chamber

Inductively coupled plasmas (ICPs) are extensively used for materials processing and microelectronics fabrication. However, their electromagnetic properties have not been fully characterized. In this regard, we have performed fully three dimensional (3D), time dependent measurements of the magnetic field, electron density, and electron temperature for an ICP sustained in argon in an industrial reactor designed for plasma etching in microelectronics fabrication. These measurements were compared to modeling results. The plasma was generated using pulsed power delivered at 2 MHz by a planar coil. The magnetic field was measured using a three axis magnetic probe at 15 366 locations throughout the plasma volume during the H-mode portion of the pulse at temporal intervals of 2 ns. A swept Langmuir probe was used to measure plasma parameters at the same locations. The plasma density measurement was calibrated with line-integrated densities obtained using a 96 GHz interferometer. During a single radio frequency (RF) cycle, the 3D current density [derived from B(r→,t)]is initially maximum just below the coil and moves downward toward the center of the chamber. Isosurfaces of current are nearly symmetric toroids. The total electric field, space charge field, and inductive electric field were derived and used to calculate the dissipated power, plasma current, and Poynting flux. Computer modeling of the experiment reproduces the phase dependent behavior. Animations showing the time dependent 3D measurements are presented in the supplementary material.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Overview of Broadband Laser Ranging (BLR) Architecture and Measurement Considerations

Broadband Laser Ranging (BLR) is a developmental diagnostic intended to measure the position of rapidly moving surfaces in combination with optical velocimetry. Design and employment of a BLR diagnostic on dynamic experiments requires consideration for both the inherent measurement system tradeoffs as well as architectural choices appropriate to the nature of investigation. The diagnostic uses spectral interferometry to measure distance by mapping femtosecond laser pulses to the time domain via chromatic dispersion within the fiber-optic architecture. The system parameters and governing equations that describe measurement range, resolution, and Doppler sensitivity will be discussed. We will also briefly review the impact of diagnostic architectural choices including: nature of interferometer, Interferometric dispersion matching, optical amplification, integration of optical velocimetry, BLR calibration, and field operability. To summarize we will present the architectural and operational approach currently being pursued by NSTec within an on-going collaboration between NSTec, Lawrence Livermore and Los Alamos National Labs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibrating Droplet Generator for Pressurized Testing Vessel

Device helps to aline laser for droplet-sizing interferometer. Monodispersing Droplet Generator creates uniformly sized droplets. Laser source and receiver of interferometer alined and focused on droplets. MDG mounted in high-pressure flange on tank. Line extensions pass through flange to outside. Flange allows MDG to operate at high injector back pressures used for tests.

Defever, G. J.↗

REDUNDANT ARRAY CONFIGURATIONS FOR 21 cm COSMOLOGY

Realizing the potential of 21 cm tomography to statistically probe the intergalactic medium before and during the Epoch of Reionization requires large telescopes and precise control of systematics. Next-generation telescopes are now being designed and built to meet these challenges, drawing lessons from first-generation experiments that showed the benefits of densely packed, highly redundant arrays—in which the same mode on the sky is sampled by many antenna pairs—for achieving high sensitivity, precise calibration, and robust foreground mitigation. In this work, we focus on the Hydrogen Epoch of Reionization Array (HERA) as an interferometer with a dense, redundant core designed following these lessons to be optimized for 21 cm cosmology. We show how modestly supplementing or modifying a compact design like HERA’s can still deliver high sensitivity while enhancing strategies for calibration and foreground mitigation. In particular, we compare the imaging capability of several array configurations, both instantaneously (to address instrumental and ionospheric effects) and with rotation synthesis (for foreground removal). We also examine the effects that configuration has on calibratability using instantaneous redundancy. We find that improved imaging with sub-aperture sampling via “off-grid” antennas and increased angular resolution via far-flung “outrigger” antennas is possible with a redundantly calibratable array configuration.

79 ASTRONOMY AND ASTROPHYSICS↗

Shear/Defocus Sensitivity of the Mid Infrared Channel (MIR) of the Composite Infrared Spectrometer (CIRS) for the Cassini Mission to Saturn

The Composite Infrared Spectrometer (CIRS) of the Cassini mission to Saturn has two interferometers covering the far infrared and mid infrared wavelength region. The mid infrared wavelength interferometer has a focal plane consisting of a germanium focus lens and HgCdTe array. System level calibration of the CIRS Flight Unit indicated a discrepancy between the expected and actual signal levels. Testing on the CIRS breadboard and Engineering Unit indicated that defocus of the germanium lens could significantly reduce the modulation efficiency of the interferometer in the presence of a moderate degree of wavefront shear. Defocus of the lens in the focal plane was of concern because of the temperature dependence of the index of refraction of germanium and our nominal operation temperature of 170 K. The shear/defocus interaction was extensively investigated and correlated to a newly developed analytical model, It was eventually determined that the CIRS instrument was in focus, had no appreciable wavefront shear and was operating near theoretical limits. The shear/defocus effect is however, of considerable interest, since it has not been described in previous literature on interferometers.

Martino, Anthony J.↗

Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 10{sup 11}–10{sup 13} cm{sup −3} and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called “frequency sweep” method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Resolution Wavenumber Standards for the Infrared. (IUPAC Recommendations 1995)

The calibration of high resolution infrared spectra is generally more precise than accurate even when they are recorded with Fourier interferometers. In order to improve the consistency of the spectral measurements, an IUPAC project has been undertaken. Its aim was to recommend a selection of spectral lines as wavenumber standards for absolute calibration in the infrared. This paper will report the final recommendations in the spectral range extending from about 4 to about 7000 cm(be).

High Resolution Wavenumber Standards↗

A Short-Range Distance Sensor with Exceptional Linearity

A sensor has been demonstrated that can measure distance over a total range of about 300 microns to an accuracy of about 0.1 nm (resolution of about 0.01 nm). This represents an exceptionally large dynamic range of operation - over 1,000,000. The sensor is optical in nature, and requires the attachment of a mirror to the object whose distance is being measured. This work resulted from actively developing a white light interferometric system to be used to measure the depths of defects in the Space Shuttle Orbiter windows. The concept was then applied to measuring distance. The concept later expanded to include spectrometer calibration. In summary, broadband (i.e., white) light is launched into a Michelson interferometer, one mirror of which is fixed and one of which is attached to the object whose distance is to be measured. The light emerging from the interferometer has traveled one of two distances: either the distance to the fixed mirror and back, or the distance to the moving mirror and back. These two light beams mix and produce an interference pattern where some wavelengths interfere constructively and some destructively. Sending this light into a spectrometer allows this interference pattern to be analyzed, yielding the net distance difference between the two paths. The unique feature of this distance sensor is its ability to measure accurately distance over a dynamic range of more than one million, the ratio of its range (about 300 microns) to its accuracy (about 0.1 nanometer). Such a large linear operating range is rare and arises here because both amplitude and phase-matching algorithms contribute to the performance. The sensor is limited by the need to attach a mirror of some kind to the object being tracked, and by the fairly small total range, but the exceptional dynamic range should make it of interest.

Simmons, Steven↗

High Resolution Wavenumber Standards for the Infrared. (IUPAC Recommendations 1995)

The calibration of high resolution infrared spectra is generally more precise than accurate. This is the case even when they are recorded with Fourier transform interferometers. This presentation aims at improving the accuracy of wavenumber measurements in the infrared by recommending a selection of spectral lines as wavenumber standards for absolute calibration.

Interferometers Infrared Spectra Wavenumbers Fouri↗

An Interferometry Imaging Beauty Contest

We present a formal comparison of the performance of algorithms used for synthesis imaging with optical/infrared long-baseline interferometers. Six different algorithms are evaluated based on their performance with simulated test data. Each set of test data is formated in the interferometry Data Exchange Standard and is designed to simulate a specific problem relevant to long-baseline imaging. The data are calibrated power spectra and bispectra measured with a ctitious array, intended to be typical of existing imaging interferometers. The strengths and limitations of each algorithm are discussed.

aperture synthesis↗

Implementation of RF Circuitry for Real-Time Digital Beam-Forming SAR Calibration Schemes

The SweepSAR architecture for space-borne remote sensing applications is an enabling technology for reducing the temporal baseline of repeat-pass interferometers while maintaining near-global coverage. As part of this architecture, real-time digital beam-forming would be performed on the radar return signals across multiple channels. Preserving the accuracy of the combined return data requires real-time calibration of the transmit and receive RF paths on each channel. This paper covers several of the design considerations necessary to produce a practical implementation of this concept.

calibration↗

CONSTRAINING POLARIZED FOREGROUNDS FOR EoR EXPERIMENTS. I. 2D POWER SPECTRA FROM THE PAPER-32 IMAGING ARRAY

Current generation low-frequency interferometers constructed with the objective of detecting the high-redshift 21 cm background aim to generate power spectra of the brightness temperature contrast of neutral hydrogen in primordial intergalactic medium. Two-dimensional (2D) power spectra (power in Fourier modes parallel and perpendicular to the line of sight) that formed from interferometric visibilities have been shown to delineate a boundary between spectrally smooth foregrounds (known as the wedge ) and spectrally structured 21 cm background emission (the EoR window ). However, polarized foregrounds are known to possess spectral structure due to Faraday rotation, which can leak into the EoR window. In this work we create and analyze 2D power spectra from the PAPER-32 imaging array in Stokes I, Q, U, and V. These allow us to observe and diagnose systematic effects in our calibration at high signal-to-noise within the Fourier space most relevant to EoR experiments. We observe well-defined windows in the Stokes visibilities, with Stokes Q, U, and V power spectra sharing a similar wedge shape to that seen in Stokes I. With modest polarization calibration, we see no evidence that polarization calibration errors move power outside the wedge in any Stokes visibility to the noise levels attained. Deeper integrations will be required to confirm that this behavior persists to the depth required for EoR detection.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-axis Heterodyne Interferometry at MHz Frequencies: a Short-Arm Measurement Demonstration for LISA with Off-The-Shelf Hardware

We report the design, construction, and operation of a multi-axis heterodyne interferometry (MAHI) system operating at MHz heterodyne frequencies, which provides a testbed for technologies to be used in the Laser Interferometer Space Antenna (LISA) space-based gravitational wave mission. The system was calibrated for measurement of the piston, pitch, and yaw of a three-axis piezo-actuated mirror, giving measured calibration values that closely match those predicted by a simulation based on Gaussian beam tracing. The piston sensitivity of the MAHI system in the LISA band was measured to be below 10pmHz 1/2 10pmHz1/2 for frequencies above 4 mHz and below 1pmHz 1/2 1pmHz1/2 for frequencies above 35 mHz. The sensitivity is limited above 2 Hz by the mechanical vibrations of the apparatus and below 1 mHz by dimensional changes caused by temperature fluctuations. Evidence points towards scattered light as the limiting noise source at intermediate frequencies. The angular sensitivity of the MAHI system was measured to be close to or below 10nradHz 1/2 10nradHz1/2 for frequencies above 4 mHz and below 1nradHz 1/2 1nradHz1/2 for frequencies above 100 mHz. Noise budgets for both length and angle were determined, indicating the areas in which improvements must be made in order to reach increased sensitivity. The current operating sensitivity already provides a useful testbed for LISA technologies and a potential blueprint for future ground segment equipment.

Fulda, P.↗

Evaluating the World Infrared Standard Group Field Campaign Report

The standard to which broadband infrared irradiance radiometers (pyrgeometers) are compared is called the World Infrared Standard Group (WISG), maintained in Davos, Switzerland, at the World Radiation Center. WISG consists of four pyrgeometers that were calibrated using the absolute sky-scanning radiometer (ASR; Philipona 2001). The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) user facility has recently adopted this as its standard and all Eppley precision infrared radiometer (PIR) pyrgeometers in ARM are currently being calibrated by transfer calibrations from WISG. Subsequently, the ASR has fallen out of operation, Julian Gröbner (2012) developed the infrared integrating sphere (IRIS) radiometer, and Ibrahim Reda (2012) developed the absolute cavity pyrgeometer (ACP). The IRIS and ACP make absolute measurements of broadband downwelling infrared irradiance using different approaches. These two instruments have been compared to each other and to the WISG (Gröbner et al. 2014). The two newer instruments agreed within about 1 Wm-2 with each other, but not with the WISG, which was 2-5 Wm-2 lower depending on the column water vapor loading. Consequently, a case for changing the current WISG has been made by Gröbner and Reda, basing their suggestion on a total of nine hours of simultaneous IRIS and ACP comparison data as well as data from 177 clear-sky nights between the IRIS and WISG radiometers from October 2009 to December 2013 (Gröbner et al. 2014). These findings were later confirmed during the second International Pyrgeometer Comparison (IPgC-II) held in September/October 2015 at Physikalisch-Meteorologisches Observatorium Davos (PMOD)/World Radiation Center (WRC), bringing the total to about 20 hours of simultaneous ACP and IRIS measurements spread across two years and five days, in the mountainous environment of Davos. For this campaign, the WISG evaluation team deployed several instruments for absolute infrared radiation measurements and pyrgeometers that have been tied to the original standard (ASR) to ARM’s Southern Great Plains (SGP) atmospheric observatory in the fall of 2017. The experiment was carried out in two phases in order to increase the probability of collecting measurements at a range of water vapor column values, to which the measurements have shown some dependence. Phase 1 of the deployment ran from October 15 to 28, and Phase 2 ran from November 26 to December 9. Four redundant IRIS and two redundant ACP made coincident measurements during this time (the ASR no longer being available for comparison). The link to the WISG was provided by two pyrgeometers calibrated relative to the WISG prior to the campaign at SGP and also measuring coincidently with the two absolute radiometers. In addition, three of the original pyrgeometers directly tied to the original ASR were deployed. (See Figure 1 for instrument setup.) The experiment took place in the fall when water vapor columns were expected to range below and above the 1-cm level that is crucial for ferreting out the water vapor dependence of these measurements that has been noted in Gröbner et al. 2014 and other measurements. An additional source of longwave radiation flux observations was provided by the atmospheric emitted radiance interferometer (AERI). The AERI measures downwelling spectral radiance from 3.3 to 19 μm with a calibration that is better than 1% of the ambient radiance (Knuteson et al. 2004), and so serves as a potential source of evaluation for the WISG. The AERI’s field of view is 2 degrees, and is directed towards zenith. Earlier ARM projects led by Tony Clough as part of the Broadband Heating Rate Profile (BBHRP) effort demonstrated how to derive longwave flux from these zenith radiance observations.

AERI, instrument calibration, Southern Great Plain↗

Design and first plasma measurements of the ITER-ECE prototype radiometer

On ITER, second harmonic optically thick electron cyclotron emission (ECE) in the range of 220-340 GHz will supply the electron temperature (T{sub e}). To investigate the requirements and capabilities prescribed for the ITER system, a prototype radiometer covering this frequency range has been developed by Virginia Diodes, Inc. The first plasma measurements with this instrument have been carried out on the DIII-D tokamak, with lab bench tests and measurements of third through fifth harmonic ECE from high T{sub e} plasmas. At DIII-D the instrument shares the transmission line of the Michelson interferometer and can simultaneously acquire data. Comparison of the ECE radiation temperature from the absolutely calibrated Michelson and the prototype receiver shows that the ITER radiometer provides accurate measurements of the millimeter radiation across the instrument band.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗