At least 127 records · Page 7

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Directionally asymmetric nonlinear optics in ferrorotational MnTiO 3

Ferrorotationally ordered materials possess a planar chiral lattice of electric dipoles that are a promising platform for exhibiting directionally asymmetric response functions. A key characteristic of such order is that enantiomorph conversion occurs when the solid is flipped by 180° about an in-plane axis. Using second-harmonic interferometry, we show here that when circularly polarized light is incident on MnTiO 3 , the generated harmonic intensity depends on whether the incident light is parallel or antiparallel to the ferrorotational axis. For a particular photon helicity, constructive interference occurs in one direction while destructive interference occurs in the other. Here, our observations represent a fundamentally new optical effect, associated with circularly polarized light in ferrorotational solids, that is distinct from conventional optical activity observed in three-dimensional chiral and Faraday media.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Benchmarking of hydrodynamic plasma waveguides for multi-GeV laser-driven electron acceleration

Hydrodynamic plasma waveguides initiated by optical field ionization have recently become a key component of multi-GeV laser wakefield accelerators. Here, we present the most complete and accurate experimental and simulation-based characterization to date, applicable to current multi-GeV experiments and future 100 GeV-scale laser plasma accelerators. Crucial to the simulations is the correct modeling of intense Bessel beam interaction with meter-scale gas targets, the results of which are used as initial conditions for hydrodynamic simulations. The simulations are in good agreement with our experiments measuring evolving plasma and neutral hydrogen density profiles using two-color short pulse interferometry, enabling realistic determination of the guided mode structure for application to laser-driven plasma accelerator design. Published by the American Physical Society 2024

Physics↗

New Method for the Astrometric Direct Detection of Ultralight Dark Matter

Ultralight dark matter induces time-dependent perturbations in the spacetime metric, enabling its . In this Letter, we propose using astrometry to detect dark matter. After reviewing the calculation of the metric in the presence of scalar dark matter, we study the influence of the perturbations on the apparent motion of astrophysical bodies. We apply our results to angular position measurements of quasars, whose vast distances from Earth present an opportunity to discover subcomponent dark matter with a mass as low as 10 − 33 eV . We explore the prospects of very long baseline interferometry and optical astrometric survey measurements for detecting ultralight relics, finding that for the smallest masses, current astrometric surveys can detect dark matter moving locally with a velocity of 10 − 3 with energy density as low as 3 × 10 − 11 GeV / cm 3 . Published by the American Physical Society 2025

Dror, Jeff A. (ORCID:0000000301106184)↗

Reductive quantum phase estimation

Estimating a quantum phase is a necessary task in a wide range of fields of quantum science. To accomplish this task, two well-known methods have been developed in distinct contexts, namely, Ramsey interferometry (RI) in atomic and molecular physics and quantum phase estimation (QPE) in quantum computing. We demonstrate that these canonical examples are instances of a larger class of phase estimation protocols, which we call reductive quantum phase estimation (RQPE) circuits. Here, we present an explicit algorithm that allows one to create an RQPE circuit. This circuit distinguishes an arbitrary set of phases with a smaller number of qubits and unitary applications, thereby solving a general class of quantum hypothesis testing to which RI and QPE belong. We further demonstrate a tradeoff between measurement precision and phase distinguishability, which allows one to tune the circuit to be optimal for a specific application. Published by the American Physical Society 2024

Papadopoulos, Nicholas J. C. (ORCID:00000002635700↗

Quantum Frequency Combs with Path Identity for Quantum Remote Sensing

Quantum sensing promises to revolutionize sensing applications by employing quantum states of light or matter as sensing probes. Photons are the clear choice as quantum probes for remote sensing because they can travel to and interact with a distant target. Existing schemes are mainly based on the quantum illumination framework, which requires quantum memory to store a single photon of an initially entangled pair until its twin reflects off a target and returns for final correlation measurements. Existing demonstrations are limited to tabletop experiments, and expanding the sensing range faces various roadblocks, including long-time quantum storage and photon loss and noise when transmitting quantum signals over long distances. We propose a novel quantum sensing framework that addresses these challenges using quantum frequency combs with path identity for remote sensing of signatures (“qCOMBPASS”). The combination of one key quantum phenomenon and two quantum resources—namely, quantum-induced coherence by path identity, quantum frequency combs, and two-mode squeezed light—allows for quantum remote sensing without requiring quantum memory. The proposed scheme is akin to a quantum radar based on entangled frequency-comb pairs that uses path identity to detect, range, or sense a remote target of interest by measuring pulses of one comb in the pair that never traveled to the target but that contains target information “teleported” by quantum-induced coherence by path identity from the other comb in the pair that traveled to the target but is not detected. We develop the basic qCOMBPASS theory, analyze the properties of the qCOMBPASS transceiver, and introduce the qCOMBPASS equation—a quantum analog of the well-known LIDAR equation in classical remote sensing. We also describe an experimental scheme to demonstrate the concept using two-mode squeezed quantum combs. qCOMBPASS can strongly impact various applications in remote quantum sensing, imaging, metrology, and communications. These applications include detection and ranging of low-reflectivity objects, measurement of small displacements of a remote target with precision beyond the standard quantum limit (SQL), standoff hyperspectral quantum imaging, discreet surveillance from space with low detection probability (detect without being detected), very-long-baseline interferometry, quantum Doppler sensing, quantum clock synchronization, and networks of distributed quantum sensors. Published by the American Physical Society 2024

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Collinear Three-Photon Excitation of a Strongly Forbidden Optical Clock Transition

The 1 𝑆 0 − 3 𝑃 0 clock transition in strontium serves as the foundation for the world’s best atomic clocks and for gravitational wave detector concepts in clock atom interferometry. This transition is weakly allowed in the fermionic isotope 87 Sr but strongly forbidden in bosonic isotopes. Here, we demonstrate coherent excitation of the clock transition in bosonic 88 Sr using a novel collinear three-photon process in a weak magnetic field. We observe Rabi oscillations with frequencies of up to 50 kHz using W/cm 2 laser intensities and Gauss-level magnetic field amplitudes. The absence of nuclear spin in bosonic isotopes offers decreased sensitivity to magnetic fields and optical lattice light shifts, enabling atomic clocks with reduced systematic errors. The collinear propagation of the laser fields permits the interrogation of spatially separated atomic ensembles with common laser pulses, a key requirement for dark matter searches and gravitational wave detection with next-generation quantum sensors.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-Power Clock Laser Spectrally Tailored for High-Fidelity Quantum State Engineering

Highly frequency-stable lasers are ubiquitous tools for optical-frequency metrology, precision interferometry, and quantum information science. While making a universally applicable laser is unrealistic, spectral noise can be tailored for specific applications. Here we report a high-power 698-nm clock laser with a maximum output of 4W and minimized frequency noise up to a few kHz Fourier frequency, together with long-term instability of 3.5 × 10 −17 at one to thousands of seconds. The laser-frequency noise is precisely characterized with atom-based spectral analysis that employs a pulse sequence designed to suppress sensitivity to intensity noise. This method provides universally applicable tunability of the spectral response and analysis of quantum sensors over a wide frequency range. With the optimized laser system characterized by this technique, we achieve an average single-qubit Clifford gate fidelity of up to 𝐹$^2_1$ = 0.999⁢64⁢(3) when simultaneously driving 3000 optical qubits with a homogeneous Rabi frequency ranging from 10 Hz to 1 kHz. This result represents the highest single optical-qubit-gate fidelity for a large number of atoms.

atomic gases↗

Evidence of Chiral Fermion Edge Modes through Geometric Engineering of Thermal Hall Effect in 𝛼−RuCl 3

The experimental observation of half-integer-quantized thermal Hall conductivity in the Kitaev candidate material α-RuCl 3 has served as a signature of non-Abelian anyons through an associated chiral Majorana edge mode. However, both the reproducibility of the quantized thermal Hall conductivity and the fundamental nature of the associated heat carriers, whether bosonic or fermionic, are subjects of ongoing and vigorous debate. In a recent theoretical work, it was proposed that varying the sample geometry through creating constrictions can distinguish between different origins of the thermal Hall effect in magnetic insulators. Here, in this study, we provide experimental evidence of chiral fermion edge modes by comparing the thermal Hall effect of a geometrically constricted α-RuCl 3 sample with that of an unconstricted sample. In contrast to the unconstricted crystals where the thermal Hall signal fades below 5 K, the constricted crystals display a significant thermal Hall signal that remains measurable even at 2 K. This sharp difference agrees well with the theoretical prediction and provides compelling evidence for the contribution of chiral fermion edge modes to the thermal Hall effect in α-RuCl 3 . More broadly, this work confirms that the geometry dependence of the thermal Hall effect can help identify chiral spin liquids in candidate materials like α-RuCl 3 and paves the way for the experimental realization of thermal anyon interferometry.

Zhang, Heda [Oak Ridge National Laboratory (ORNL),↗

Coherence-mediated quantum thermometry in a hybrid circuit quantum electrodynamics architecture

Quantum thermometry plays a critical role in the development of low-temperature sensors and quantum information platforms. Here, in this work, we propose and analyze a hybrid circuit quantum electrodynamics architecture in which a superconducting qubit is dispersively coupled to two distinct bosonic modes: one initialized in a weak coherent state as a phase reference and information buffer and the other coupled to a thermal environment. We show that the qubit serves as a sensitive readout of the probe mode, mapping the interplay between thermal and coherent photon-number fluctuations onto measurable dephasing. This coherence-mediated mechanism enables improved sensitivity to thermal energy fluctuations in the sub-millikelvin regime through Ramsey interferometry. We derive analytic expressions for the probe coherence envelope, compute the quantum Fisher information for temperature estimation, and demonstrate numerically that the presence of a coherent reference enhances the qubit's sensitivity to small changes in thermal photon occupancy. Our results establish a coherence-enabled approach to thermometry and provide a scalable platform for future calorimetric sensing in high-energy physics and quantum metrology.

Zhu, Shaojiang [Fermi National Accelerator Laborat↗

Geometric invariants of quantum metrology

Here, we establish a conservation law for the Quantum Fisher Information Matrix (QFIM) expressed as follows; when the QFIM is constructed from a set of observables closed under commutation, i.e., a Lie algebra, the spectrum of the QFIM is invariant under unitary dynamics generated by these same operators. Each Lie algebra therefore endows any quantum state with a fixed “budget” of metrological sensitivity—an intrinsic resource that we show, like optical squeezing in interferometry, cannot be amplified by symmetry-preserving operations. The Uhlmann curvature tensor naturally inherits the same symmetry group, and so quantum incompatibility is similarly fixed. As a result, a metrological analog to Liouville's theorem appears; statistical distances, volumes, and curvatures are invariant under the evolution generated by the Lie algebra. We discuss this as it relates to the quantum analogs of classical optimality criteria. This enables one to efficiently classify useful classes of quantum states at the level of Lie algebras through geometric invariants.

Wilson, Christopher [University of Colorado, Bould↗

Generation of scalable genuine multipartite Gaussian entanglement with a parametric amplifier network

Genuine multipartite entanglement is a valuable resource in quantum information science, as it exhibits inseparability across all possible bipartitions of a multimode quantum state. The large degree of quantum correlations can be exploited in various quantum information protocols, such as teleportation, dense coding, and quantum interferometry. Here, in this study, we propose a scheme to generate scalable genuine multipartite continuous-variable entangled states of light using a parametric amplifier network. We verify the presence of genuine quadripartite, hexapartite, and octapartite entanglement through a violation of the positive partial transpose criteria. Additionally, we use 𝛼-entanglement of formation to demonstrate the scalability of our approach to an arbitrary number of 2⁢𝑁 genuinely entangled parties by taking advantage of the symmetries present in our scheme.

Kim, Saesun [Univ. of Oklahoma, Norman, OK (United↗

Fabrication and characterization of a full-size ultra-precise lamellar grating for the Cosmic beamline at ALS-U

We have developed a new process for the production of ultra-precise variable line spacing (VLS) lamellar diffraction gratings through nanofabrication. The process enables the fabrication of full-size X-ray gratings with sub-nanometre accuracy in groove depth, an optimal land-to-groove ratio, and uniform groove depth across the entire grating area. We also established a method for evaluating VLS groove density variation using stitched Fizeau interferometry. The measurements confirmed the exceptionally high accuracy of the VLS groove density in the fabricated gratings, which is well within the specification tolerances while the residual groove density errors are vanishingly small. The gold-coated grating demonstrated near-theoretical diffraction efficiency across the energy range of 100–1200 eV.

36 MATERIALS SCIENCE↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Momentum-exchange interactions in a Bragg atom interferometer suppress Doppler dephasing

Large ensembles of laser-cooled atoms interacting through infinite-range photon-mediated interactions are powerful platforms for quantum simulation and sensing. Here we realize momentum-exchange interactions in which pairs of atoms exchange their momentum states by collective emission and absorption of photons from a common cavity mode, a process equivalent to a spin-exchange or XX collective Heisenberg interaction. The momentum-exchange interaction leads to an observed all-to-all Ising-like interaction in a matter-wave interferometer. A many-body energy gap also emerges, effectively binding interferometer matter-wave packets together to suppress Doppler dephasing in analogy to Mössbauer spectroscopy. The tunable momentum-exchange interaction expands the capabilities of quantum interaction–enhanced matter-wave interferometry and may enable the realization of exotic behaviors, including simulations of superconductors and dynamical gauge fields.

Science & Technology - Other Topics↗

Stochastic frequency fluctuation super-resolution imaging

The inherent non-linearity of intensity correlation functions can be used to spatially distinguish identical emitters beyond the diffraction limit, as achieved, for example, in super-resolution optical fluctuation imaging (SOFI). Here, we propose a complementary concept based on spectral correlation functions, termed spectral fluctuation super-resolution (SFSR) imaging. Through theoretical and computational analysis, we show that spatially resolving time-frequency correlation functions in the image plane can improve the imaging resolution by a factor of $\sqrt2$ in most cases and up to twofold for strictly two emitters. This improvement is achieved by quantifying the degree of correlation in spectral fluctuations across the spatial domain. Experimentally, SFSR can be implemented using a combination of interferometry and photon-correlation measurements. The method works for non-blinking emitters and stochastic spectral fluctuations with arbitrary temporal statistics. This suggests its utility in super-resolution microscopy of quantum emitters at low temperatures, where spectral diffusion is often more pronounced than emitter blinking.

47 OTHER INSTRUMENTATION↗

Rapidly tunable ultrabroadband flying focus using adaptive optics and an axiparabola

A programmable ultrabroadband flying focus was produced using adaptive optics and an axiparabola with a continuous wave superluminescent diode. A deformable mirror and spatial light modulator were used to add a programmable amount of radial group delay, and an axiparabola was used to create an extended focus by imparting spherical aberration. Three different flying focus trajectories were measured using spectral interferometry, two with uniform velocity and one with an accelerating velocity. Here, the temporal response function width of the flying focus optics alone was calculated to be 52 ± 6 fs, and the focal spot size was measured to be (1.2 ± 0.1) × larger than the diffraction-limited spot size through the extended focus.

Markland, H. S. [University of Rochester, NY (Unit↗

Ultrafast temporal phase-resolved nonlinear optical spectroscopy in the molecular frame

In an ultrafast nonlinear optical interaction, the electric field of the emitted nonlinear signal provides direct access to the induced nonlinear transient polarization or transient currents and thus carries signatures of ultrafast dynamics in a medium. Measurement of the electric field of such signals offers sensitive observables to track ultrafast electron dynamics in various systems. In this work, we resolve the real-time phase of the electric field of a femtosecond third-order nonlinear optical signal in the molecular frame. The electric field emitted from impulsively pre-aligned gas-phase molecules at room temperature, in a degenerate four-wave mixing scheme, is measured using a spectral interferometry technique. The nonlinear signal is measured around a rotational revival to extract its molecular-frame angle dependence from pump-probe time-delay scans. By comparing these measurements for two linear molecules, carbon dioxide and nitrogen, we show that the measured second-order phase parameter (temporal chirp) of the signal is sensitive to the valence electronic symmetry of the molecules, whereas the amplitude of the signal does not show such sensitivity. We compare measurements to theoretical calculations of the chirp observable in the molecular frame. This work is an important step towards using electric field measurements in nonlinear optical spectroscopy to study ultrafast dynamics of electronically excited molecules in the molecular frame.

47 OTHER INSTRUMENTATION↗