Search NASA⌕ Search

SEARCH · Search NASA

Results for “intrusion detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Increased Interpretability for Model-Driven Deception: MARS LDRD Project

Machine learning has been proposed as a solution to several cybersecurity solutions and one of the most promising applications is for digital twins for intrusion detection and driving deceptive defense. However, machine learning techniques often result in a black-box function that is difficult for end users to interpret which for deception limits their ability to effectively define decoys. In this report, an approach to validate the equations learned are accurate is provided and demonstrated. Following, begins the process of addressing this issue for a model-driven deception technology that produces equations representing the physical process controlled by operation technology devices. This research was performed by applying subject matter expert context to machine learned models.

97 MATHEMATICS AND COMPUTING↗

Enabling Cybersecurity, Situational Awareness and Resilience in Distribution Grids with High Penetration of Photovoltaics (CARE-PV) (Final Report)

Since legacy distribution systems have very limited visibility beyond the substation, high penetration of PV at the grid edge presents some unique operational challenges. One approach to address these challenges is to use information from advanced metering infrastructure (AMI) and µPMUs. However, exploiting this information is impacted by a number of factors, including multi-timescale measurements, volume of data generated, communication network impairments (e.g., information loss and latency) and susceptibility to cyber-attacks. Therefore, one of the critical tasks involved in the management of a distribution grid is to develop complete situational awareness by integrating cyber-security mechanisms with state estimation strategies and leveraging this situational awareness to assure energy services at strategic locations while exploiting AMI/PV inverter/ µPMU data. This CARE-PV project addresses the fundamental challenges in situational awareness and resilience to cyber and physical vectors by exploiting the synergy between innovative modeling, estimation, data analytics, testing and validation using smart PV inverters designed at K-State and facilities at NREL. Specifically, the project involved the development, testing and validation of the following novel enabling technologies: (Thrust 1) Resilience to cyber vectors that impact data integrity was addressed via a two-level defense strategy that combines cyber intrusion detection using self-learning, cooperative smart PV inverters, and a novel moving target defense framework to combat data integrity attacks. (Thrust 2) Resilience to cyber-physical vectors that impact situational awareness by limiting data availability was addressed via novel centralized and decentralized, sparsity-based static and dynamic state estimation approaches that enhance observability even when the underlying system is unobservable. (Thrust 3) Leveraging a unique probabilistic sensitivity analysis approach accompanied by one-of-a-kind dominant influencer set computation, the vulnerability of critical infrastructure at strategic locations was evaluated so that proactive PV-based control strategies can be used to support operations under normal/outage scenarios. These CARE-PV project innovations were demonstrated on both small-scale IEEE and larger utility-scale testbeds (Thrust 4). Feedback from Industry Advisory Board members was used to formulate a commercialization pathway for a subset of CARE-PV technologies. These CARE-PV technologies will ultimately lead to reliable and secure, large-scale integration of renewable energy and mitigate the risk of energy disruption resulting from cyber incidents and other emerging threats within the energy environment.

14 SOLAR ENERGY↗

Multilevel Cybersecurity for Photovoltaic Systems

The motivation behind this project is to protect critical infrastructure in electric power generation pertaining to solar photovoltaic (PV) systems. This growing renewable energy resource is becoming a more vital part of the nation’s energy portfolio, particularly since it has achieved grid-parity to existing generation methods in terms of cost. It is thus vital that steps be taken to ensure the cybersecurity of these assets. The project goal was to devise a multilevel cybersecurity solution to address PV security gaps at the inverter and system levels, and field test the solution under the supervision and review of a US-based solar inverter manufacturer and PV installer/operator. A two-level cyberattack defense approach was formulated whereby the first level, the solar inverter level, hardens individual devices and achieves a deeply cyber-secure inverter. The inverter level security involves a multi-layer defense-in-depth approach for securing the inverter while also providing data for the system level algorithms. The second level, the system level, addresses intrusion detection and restoration involving an ensemble of inverters and relevant systems.

14 SOLAR ENERGY↗

PLC Vulnerabilities and Mitigations

Programmable Logic Controllers (PLCs) are used extensively in many high-importance industrial and nonindustrial settings including controlling elevators, manufacturing machines, and utility facilities such as power and natural gas, however cybersecurity protection for them has been neglected. Within recent years, PLCs have been put under more security scrutiny and experts have advocated for changes from the addition of protocol encryption and network segmentation to intrusion detection systems on the PLCs themselves. While PLC security is critical, a large portion of the PLCs available today will never receive these changes due to being legacy or the difficulty of overhauling the security on existing systems. Due to the infeasibility of applying many recommended security measures towards currently available machines, we aim to provide realistic and affordable best practices for hardening PLCs. We will first conduct security analysis and consider attack vectors within our target PLC. Once we’ve analyzed the device’s security, we will evaluate a variety of mitigation methods and create guidelines to effectively reduce the threat posed by PLC attacks with minimal disruption to operations.

42 ENGINEERING↗

An Advanced Cyber-Physical System Security Testbed for Substation Automation

A Cyber-Physical System (CPS) testbed serves as a powerful platform for testing and validating cyber intrusion detection and mitigation strategies in substations. This study presents the design and development of a CPS testbed that can effectively assess the real-time dynamics of a substation. Cyber attacks exploiting IEC 61850-based SV and GOOSE protocols are demonstrated using the testbed, along with an analysis on attack detection. Realistic timing measurements are obtained, and the time frames for deploying detection and mitigation strategies are evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Feasibility Study of Millimeter Wave Radars For Safeguards Applications

Containment and surveillance are fundamental measures in nuclear safeguards. Techniques such as video surveillance and laser curtain for containment provide effective monitoring in areas where maintaining continuity of knowledge is required. These systems, however, can be susceptible to loss of monitoring capabilities under certain environmental conditions such as poor visibility (i.e. low light conditions, smoke, fog, etc.) or extended power loss past the duration that the backup power system is designed for. Brookhaven National Laboratory has been investigating the feasibility of millimeter waves (mmWave) as a new perimeter seal in which radio frequency waves in the range of 60-64 GHz are used to detect and monitor objects of interest. Signals in this frequency range are not susceptible to environmental conditions. For proof-of-concept tests, mmWave sensors from Texas Instruments (TI), specificallyIWR6843, are used in a test bed at BNL's Waste Management facility to simulate the operations at nuclear facilities. The unique design of TI mmWave sensors requires less memory and power consumption compared to counterpart systems. These devices are capable of exporting 3D point-cloud data, which is visualized graphically and compared to videos recorded at the same time to validate the performance of the mmWave sensor. A set of experiments were planned to test the feasibility of the mmWave in this application, including monitoring static containers in a storage area and detecting intrusions at the boundaries of the area. In addition, the experiments also identify potential blind spots relative to sensor position and utilize multiple operating sensors simultaneously to reduce or eliminate such blind spots. The optimal positioning of multiple sensors was determined for the experimental room configuration. In this paper, we will discuss the details of this novel perimeter sealing concept and present the test results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

MSU IETC ML for Modbus (AN EDGE)

This study explores machine learning for decoding Modbus RTU data using K-Nearest Neighbors (KNN) models. An initial KNN model trained on 8,000 packets achieved 95.15% accuracy. Although ML improves generalization, accuracy still falls short of deterministic methods. These findings have implications for Modbus traffic analysis, intrusion detection in industrial networks, and adaptive error correction in real-time monitoring systems. By refining ML-based decoding, future work could enable more efficient anomaly detection and predictive maintenance in industrial automation and cybersecurity applications.

Communication Protocol↗

Digital Assurance Checklist for Homeowners and Installers

This document provides a comprehensive Digital Assurance Checklist for securing behind-the-meter energy assets, focusing on both installers and homeowners. As distributed energy resources (DERs) such as solar PV and battery storage become integral to residential energy systems, cybersecurity emerges as a critical component of reliability and safety. The guide outlines actionable steps for installers during pre-installation, commissioning, and post-installation phases, emphasizing practices like network segmentation, credential management, firmware validation, and homeowner education. For homeowners, the document introduces a tiered approach to cyber hygiene—from essential measures like strong Wi-Fi credentials and automatic updates to advanced strategies such as network segmentation, DNS filtering, and intrusion detection. By adopting these practices, stakeholders can mitigate cyber risks, safeguard energy infrastructure, and ensure resilient, secure operation of DER systems. Additional resources and references to industry standards are included to support implementation.

99 - GENERAL AND MISCELLANEOUS↗

Advanced Transmission Technologies –GETs and HPCs Session 3: HPCs and Building Actions Plans to Digital Assurance Risks

The third session of the Idaho National Laboratory’s (INL) Technical Assistance for Digital Assurance (TADA) program, held on November 11, 2025, centered on High Performance Conductors (HPCs) and the formulation of action plans to address digital assurance risks associated with Grid-Enhancing Technologies (GETs). This session convened experts from utilities, vendors, and government agencies to examine the technical, operational, and cybersecurity aspects of HPC deployment. Discussions highlighted the benefits of HPCs, such as their ability to rapidly increase transmission capacity using existing corridors, improve grid resilience, reduce system losses, and align with FERC Orders 2023 and 1920. Participants evaluated supply chain and digital assurance risks, including reliance on imported materials, limited domestic manufacturing capacity, workforce shortages, and traceability issues. The session also emphasized the importance of digital trust, integration-layer cybersecurity, and unified risk frameworks, introducing tools like intrusion detection systems, encryption, zero trust networking, and firmware integrity. Recaps of earlier workshops on Dynamic Line Ratings (DLRs), Advanced Power Flow Control (APFC), and Transmission Topology Optimization (TTO) underscored institutional barriers and integration challenges. Action plans were proposed to mitigate issues such as inconsistent cybersecurity practices, SBOM usage, supply chain visibility, operator trust, and misaligned incentives. Additionally, INL presented its supply chain risk management tools and Cyber-Informed Engineering (CIE) principles to support secure procurement and system design. The session concluded with a commitment to share key takeaways, incorporate cohort feedback into future policy development, and continue collaborative engagement through upcoming pilot activities. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Digital Assurance Checklist for Homeowners and Installers

This document provides a comprehensive Digital Assurance Checklist for securing behind-the-meter energy assets, focusing on both installers and homeowners. As distributed energy resources (DERs) such as solar PV and battery storage become integral to residential energy systems, cybersecurity emerges as a critical component of reliability and safety. The guide outlines actionable steps for installers during pre-installation, commissioning, and post-installation phases, emphasizing practices like network segmentation, credential management, firmware validation, and homeowner education. For homeowners, the document introduces a tiered approach to cyber hygiene—from essential measures like strong Wi-Fi credentials and automatic updates to advanced strategies such as network segmentation, DNS filtering, and intrusion detection. By adopting these practices, stakeholders can mitigate cyber risks, safeguard energy infrastructure, and ensure resilient, secure operation of DER systems. Additional resources and references to industry standards are included to support implementation.

99 - GENERAL AND MISCELLANEOUS↗

Detecting the Presence of Intrusive Drilling in Secure Transport Containers Using Non-Contact Millimeter-Wave Radar

We employ a 77–81 GHz frequency-modulated continuous-wave (FMCW) millimeter-wave radar to sense anomalous vibrations during vehicle transport at highway speeds for the first time. Secure metallic containers can be breached during transport by means of drilling into their sidewalls but detecting a drilling signature is difficult because the large vibrations of transport drown out the small vibrations of drilling. For the first time, we demonstrate that it is possible to use a non-contact millimeter-wave radar sensor to detect this micron-scale intrusive drilling while highway-speed vehicle movement shakes the container. With the millimeter-wave radar monitoring the microdoppler signature of the container’s vibrating walls, we create a novel signal-processing pipeline consisting of range–angle tracking, time–frequency analysis, horizontal stripe image convolution, and principal component analysis to create a robust and powerful detection statistic to alarm if drilling is present. To support this pipeline, we develop a statistical model combining the vibrating container and the random vibrations induced by vehicle movement to explore the robustness of the sensor’s detection capabilities. The presented results strongly support the inclusion of a millimeter-wave radar vibration sensor into a transport security system.

Wagner, Samuel↗

EV SALaD 2023 Demonstration: Best Practices and Mitigations for Protecting EVSE Infrastructure

The Electric Vehicle Secure Architecture Laboratory Demonstration (EV SALaD) program is a demonstration of cybersecurity best practices for high-power electric vehicle (EV) charging infrastructure led by Idaho National Laboratory (INL), in collaboration with other DOE National Laboratories participating in the EVs at Scale Consortium.a Sandia National Laboratories (SNL) and Pacific Northwest National Laboratory (PNNL) participated in the first 2-year (FY22-23) demonstration cycle for EV SALaD. This report documents the FY23 demonstration, the second in a series of demonstrations and collaborations in deploying and operating cybersecure EV charging infrastructure. It includes a summary of improvements from the FY22 demonstration, technical analysis of the FY23 demonstration, how the research demonstrates cyber-physical and cybersecurity best practices for high-power EV charging infrastructure, and related impacts to national and energy security. For EV SALaD, the FY22 demonstration focused on the detection, ranking, and prioritization of anomalous events for high-power EV charging. The FY23 demonstration additionally included the demonstration of cybersecurity best practices, which included protection and mitigation solutions to prevent, respond, and recover from anomalous events. During the demonstrations, the multi-lab EV SALaD team conducted a Test Effect Payload (TEP)b evaluation on extreme fast charger (XFC) hardware equipped with Cerberus, a detection and response solution, to demonstrate anomaly detection and mitigation cybersecurity best practices against cyber-enabled events.

33 ADVANCED PROPULSION SYSTEMS↗

General-Purpose Unsupervised Cyber Anomaly Detection via Non-Negative Tensor Factorization

Distinguishing malicious anomalous activities from unusual but benign activities is a fundamental challenge for cyber defenders. Prior studies have shown that statistical user behavior analysis yields accurate detections by learning behavior profiles from observed user activity. These unsupervised models are able to generalize to unseen types of attacks by detecting deviations from normal behavior, without knowledge of specific attack signatures. However, approaches proposed to date based on probabilistic matrix factorization are limited by the information conveyed in a two-dimensional space. Non-negative tensor factorization, on the other hand, is a powerful unsupervised machine learning method that naturally models multi-dimensional data, capturing complex and multi-faceted details of behavior profiles. Herein, our new unsupervised statistical anomaly detection methodology matches or surpasses state-of-the-art supervised learning baselines across several challenging and diverse cyber application areas, including detection of compromised user credentials, botnets, spam e-mails, and fraudulent credit card transactions.

97 MATHEMATICS AND COMPUTING↗

Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations

Integration of Information and Communication Technology (ICT) in modern smart grids (SGs) offers many advantages including the use of renewables and an effective way to protect, control and monitor the energy transmission and distribution. To reach an optimal operation of future energy systems, availability, integrity and confidentiality of data should be guaranteed. Research on the cyber-physical security of electrical substations based on IEC 61850 is still at an early stage. In the present work, we first model the network traffic data in electrical substations, then, we present a statistical Anomaly Detection (AD) method to detect Denial of Service (DoS) attacks against the Generic Object Oriented Substation Event (GOOSE) network communication. According to interpretations on the self-similarity and the Long-Range Dependency (LRD) of the data, an Auto-Regressive Fractionally Integrated Moving Average (ARFIMA) model was shown to describe well the GOOSE communication in the substation process network. Based on this ARFIMA-model and in view of cyber-physical security, an effective model-based AD method is developed and analyzed. Two variants of the statistical AD considering statistical hypothesis testing based on the Generalized Likelihood Ratio Test (GLRT) and the cumulative sum (CUSUM) are presented to detect flooding attacks that might affect the availability of the data. Our work presents a novel AD method, with two different variants, tailored to the specific features of the GOOSE traffic in IEC 61850 substations. The statistical AD is capable of detecting anomalies at unknown change times under the realistic assumption of unknown model parameters. The performance of both variants of the AD method is validated and assessed using data collected from a simulation case study. We perform several Monte-Carlo simulations under different noise variances. The detection delay is provided for each detector and it represents the number of discrete time samples after which an anomaly is detected. In fact, our statistical AD method with both variants (CUSUM and GLRT) has around half the false positive rate and a smaller detection delay when compared with two of the closest works found in the literature. Our AD approach based on the GLRT detector has the smallest false positive rate among all considered approaches. Whereas, our AD approach based on the CUSUM test has the lowest false negative rate thus the best detection rate. Depending on the requirements as well as the costs of false alarms or missed anomalies, both variants of our statistical detection method can be used and are further analyzed using composite detection metrics.

IEC 61850 electrical substations↗

Enhancing grid reliability and resilience through novel DER control, total situational awareness and integrated distribution-transmission representation

High penetration of distributed energy resources (DERs) can lead to overvoltage and thermal violations, miscoordination of protection devices and potential adverse control interactions. The challenges are exacerbated by a lack of operator situational awareness of behind-the-meter DERs, and T&D interactions. Furthermore, the large attack surface of a DER environment creates significant cyber security challenges. The motivation is to address these barriers. The main goal is to enable extreme levels of DERs in distribution systems while simultaneously enhancing their reliability and resiliency. This is achieved by a data-driven approach for operation, planning and control of distribution systems with total situational awareness and real-time DER control enabled by a network of edge intelligent devices, a cloud-based analytical platform, and secure communications.

14 SOLAR ENERGY↗

On the Limits of EM Based Detection of Control Logic Injection Attacks In Noisy Environments

The difficulty in applying traditional security mechanisms in Industrial Control System (ICS) environments makes a large portion of these mission-critical assets vulnerable to cyber attacks. Therefore, there is a dire need for the development of novel security mechanisms specifically designed to protect such critical systems. Recently a lot of attention has been given to mechanisms that exploit the EM emanations of devices for defense purposes. Such practices may lead to the development of robust external and non-intrusive anomaly detection systems. Nevertheless, the majority of current work in the area neglects to consider the implications of real-life environments, particularly environmental noise. In this work, we explore the limits of EM-based anomaly detection towards identifying injection attacks in control logic software in noisy environments. Our study conducted upon both synthetically generated and real signals identified that indeed environmental noise might significantly degrade the accuracy of the anomaly detection process. Experiments done upon synthetic data indicated that assuming that signals are captured with high sampling rates, even minor code injections can be detected with above-90% accuracy in noisy environments where SNR is up to -2dB. This is true even if naive detection methods are considered. Moreover, experiments done using a real-life testbed attest that even single-instruction injections can be detected with near-perfect accuracy in relatively clean environments. Finally, noise-elimination techniques can drastically improve the reliability of the detection mechanism even in noisy environments.

97 MATHEMATICS AND COMPUTING↗

Threat Hunt Guide for BESS Environments

The rapid digitalization of the electric grid - driven by the integration of inverter-based resources (IBRs), battery energy storage systems (BESS), and advanced grid control platforms - has significantly enhanced grid efficiency, visibility, and flexibility. However, this evolution also introduces new cybersecurity risks, particularly through supply chain dependencies and operational blind spots at the grid edge. To address these challenges, Idaho National Laboratory (INL), through the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) Rapid Risk initiative, conducted a series of rapid risk assessment engagements with energy organizations across the United States. Drawing on lessons learned from these engagements, INL developed the following threat hunting guide for asset owners and operators (AOOs) to enhance their cybersecurity visibility within BESS and IBR systems. The guide demonstrates how to use passive network monitoring to baseline device behavior, detect adversarial activity, and investigate anomalies without disrupting operations. By implementing these practices, energy sector stakeholders can improve coordination between cybersecurity and operations teams and strengthen the resilience of distributed energy resources (DERs) within the modern power grid. Prior to implementing any network monitoring, packet capture, or threat hunting activity described in this guide, AOOs are strongly advised to review applicable governance frameworks, legal requirements, and organizational policies. This guide is intended for informational and educational purposes only. It does not replace compliance with any federal, state, or local cybersecurity mandates or industry standards. Implementation of described configurations, technologies, or analytic workflows is performed at the discretion and responsibility of the asset owner and operator.

25 - ENERGY STORAGE↗