Laboratory chamber experiments exploring the potential use of artificially ionized layers of gas as a Bragg reflector for over-the-horizon signals

A set of parallel plasma layers is generated by two intersecting microwave pulses in a chamber containing dry air at a pressure comparable to the upper atmosphere. The dependence of the breakdown conditions on the pressure and pulse length is examined. The results are shown to be consistent with the appearance of tail erosion of microwave pulse caused by air breakdown. Bragg scattering experiments, using the plasma layers as a Bragg reflector are then performed. Both time domain and frequency domain measurements of wave scattering are conducted. The experimental results are found to agree very well with the theory. Moreover, the time domain measurement of wave scattering provides an unambiguous way for determining the temporal evolution of electron density during the first 100-microsec period.

Kuo, S. P.↗

Optical observations of the beam-plasma discharge phenomenon

Spectroscopic observations of optical emissions from the beam-plasma discharge (BPD) phenomenon were made with NASA's vacuum chamber facility, at the Johnson Space Center, configured to simulate the physical conditions of magnetospheric electron beam injection into the ionospheric/upper-atmospheric environment. Nonlinear N2 and N2(+) optical emission growth rates (with respect to incremental electron beam current values) were observed from the chamber gas during transition to the BPD state. For electron-beam currents (I) near the BPD transition value (I(sub c)), the band emissions from the chamber gas produced by relatively low energy (less than or equal to 50 eV) electrons interacting with N2 were anomalously more intense than those requiring higher energy (greater than 100 eV) electrons to excite them. For I more greater than I(sub c), the optical emissions increased linearly with I (as was the case for I less than I(sub c)) and their ratios decreased significantly from the peak values attained when I approximately equals I(sub c). These observations suggest that during BPD some of the energy of the primary electron beam is efficiently transferred, via wave-particle interactions, to local electrons produced through ionization of the chamber gas; the resulting suprathermal electrons provide an additional source of excitation for the relatively low energy states (A, B and C) of N2. Such nonlinear excitation of upper atmospheric gas may occur in certain auroral events wherein the current due to the precipitating electrons approaches a value close to I(sub c).

Sivjee, G. G.↗

Single grid accelerator for an ion thrustor

A single grid accelerator system for an ion thrustor is discussed. A layer of dielectric material is interposed between this metal grid and the chamber containing an ionized propellant for protecting the grid against sputtering erosion.

Margosian, P. M.↗

A balloon-borne ionization spectrometer with very large aperture for the detection of high energy cosmic rays

A balloon experiment which was used to determine the chemical composition of very high-energy cosmic rays up to and beyond 100 GeV/nucleon is described. The detector had a geometric factor of 1 sq m sr and a total weight on the balloon of 2100 kg. The apparatus consisted of an ionization spectrometer, spark chambers, and plastic scintillation and Cherenkov counters. It was calibrated at CERN up to 24 GeV/c protons and at DESY up to 7 GeV/c electrons. In October 1972 it was flown successfully on a stratospheric balloon.

Atallah, K.↗

Testing Electronic Devices for Single-Event Upset

Report prepared describes equipment and summarizes both pretest and onsite procedures for testing of digital electronic devices for susceptibility to single-event upset. Term "single-event upset" denotes variety of temporary or permanent bit flips or latchup induced by single particles of ionizing radiation. Vacuum chamber houses device under test while exposed to ion beam. Vacuum chamber and associated equipment must be brought to ion-beam facility for test.

Nichols, D. K.↗

Laser Induced Fluorescence Spectroscopy of Neutral and Ionized Polycyclic Aromatic Hydrocarbons in the Cosmic Simulation Chamber

Polycyclic aromatic hydrocarbon (PAH) molecules are considered the best carriers to account for the ubiquitous infrared emission bands. PAHs have also been proposed as candidates to explain the diffuse interstellar bands (DIBs), a series of absorption features seen on the interstellar extinction curve and are plausible carriers for the extended red emission (ERE), a photoluminescent process associated with a wide variety of interstellar environments. Extensive efforts have been devoted over the past two decades to characterize the physical and chemical properties of PAH molecules and ions in space. Absorption spectra of PAH molecules and ions trapped in solid matrices have been compared to the DIBs. Absorption spectra of several cold, isolated gas-phase PAHs have also been measured under experimental conditions that mimic the interstellar conditions. The purpose of this study is to provide a new dimension to the existing spectroscopic database of neutral and single ionized PAHs that is largely based on absorption spectra by adding emission spectroscopy data. The measurements are based on the laser induced fluorescence (LIF) technique and are performed with the Pulsed Discharge Nozzle (PDN) of the COSmIC laboratory facility at NASA Ames laboratory. The PDN generates a plasma in a free supersonic jet expansion to simulate the physical and the chemical conditions in interstellar environments. We focus, here, on the fluorescence spectra of large neutral PAHs and their cations where there is a lack of fluorescence spectroscopy data. The astronomical implications of the data (e.g., ERE) are examined.

Laboratory↗

Reactively-sputtered zinc semiconductor films of high conductivity for heterojunction devices

A high conductivity, n-doped semiconductor film is produced from zinc, or Zn and Cd, and group VI elements selected from Se, S and Te in a reactive magnetron sputtering system having a chamber with one or two targets, a substrate holder, means for heating the substrate holder, and an electric field for ionizing gases in the chamber. Zinc or a compound of Zn and Cd is placed in the position of one of the two targets and doping material in the position of the other of the two targets. Zn and Cd may be placed in separate targets while a dopant is placed in the third target. Another possibility is to place an alloy of Zn and dopant, or Zn, Cd and dopant in one target, thus using only one target. A flow of the inert gas is ionized and directed toward said targets, while a flow of a reactant gas consisting of hydrides of the group VI elements is directed toward a substrate on the holder. The targets are biased to attract negatively ionized inert gas. The desired stochiometry for high conductivity is achieved by controlling the temperature of the substrate, and partial pressures of the gases, and the target power and total pressure of the gases in the chamber.

Stirn, Richard J.↗

A measurement of the relativistic rise in xenon-filled ionisation chambers for cosmic ray iron

The relativistic rise of ionization in a pair of xenon-filled pulse ion chambers was measured for primary iron nuclei during a recent balloon flight. Energy calibration over the range 21.5-60 GeV/n was made with a Freon-12 gas Cerenkov detector. This allowed a comparison with recent calculations of the relativistic rise in xenon counters and an estimate of the ion chamber resolution above 21.5 GeV/n to be made.

Gregory, J. C.↗

Nuclear Science Symposium, 4th, and Nuclear Power Systems Symposium, 9th, San Francisco, Calif., October 19-21, 1977, Proceedings

Consideration is given to the following types of high energy physics instrumentation: drift chambers, multiwire proportional chambers, calorimeters, optical detectors, ionization and scintillation detectors, solid state detectors, and electronic and digital subsystems. Attention is also paid to reactor instrumentation, nuclear medicine instrumentation, data acquisition systems for nuclear instrumentation, microprocessor applications in nuclear science, environmental instrumentation, control and instrumentation of nuclear power generating stations, and radiation monitoring. Papers are also presented on instrumentation for the High Energy Astronomy Observatory.

Source record↗

Gas flow analysis during thermal vacuum test of a spacecraft

The self-contamination of the IMP-H spacecraft, while it was undergoing thermal and solar vacuum tests, has been investigated in conjunction with the outgassing evaluation and detection of molecular flow anomalies occurring in the test chamber. The pressures indicated by two tubulated ionization gauges were used to calculate flow kinetics in the vacuum chamber. The fluxes of emitted molecules and chamber wall reflected molecules were monitored during the entire test. Representative equations and graphs are presented. Test results indicate that from 3 to 9 of every 100 emitted molecules returned to the spacecraft surface; that self-contamination by noncondensable gases was more severe than that by condensable gases; and that outgassing of the spacecraft was approximately 1.18 x 0.01 g/s after 10 hours and 1.18 x 0.001 after 90 hours of vacuum exposure. Testing deficiencies have been identified, and the type and location of instruments required to measure the outgassing, the degree of contamination, and return flow are discussed.

Scialdone, J. J.↗

Ion thruster diagnostics using spectral line amplitudes

The optical radiation from the plasma discharge of an electron bombardment mercury ion thrustor was investigated. Using the measured ratio of the Hg I line amplitude at 3655 A to that at 3650 A, a theory incorporating a bimodal electron distribution (Maxwell electrons plus primary electrons) was used to obtain the average electron temperature and primary electron fraction in the thruster ion chamber. The electron temperature ranged from about 1.2 eV to 6.6 eV; whereas the primary electron fraction varied from zero percent to about 5 percent. These values depended upon the discharge voltage and the radial location of the measurement. The percentage of doubly ionized mercury produced in the chamber was also determined as a function of discharge voltage.

Milder, N. L.↗

Ion thruster diagnostics using spectral line amplitudes.

The optical radiation from the plasma discharge of an electron bombardment mercury ion thruster was investigated. This work extends and refines earlier measurements, correcting certain ambiguities that arose in the analysis of line amplitudes. Using the measured ratio of the Hg I line amplitude at 3655 A to that at 3650 A, a theory incorporating a bimodal electron distribution (Maxwell electrons plus primary electrons) was used to obtain the average electron temperature and primary electron fraction in the thruster ion chamber. The electron temperature ranged from about 1.2 eV to 6.6 eV; whereas the primary electron fraction varied from zero percent to about 5 percent. These values depended upon the discharge voltage and the radial location of the measurement. The percentage of doubly ionized mercury produced in the chamber was also determined as a function of discharge voltage.

Milder, N. L.↗

Sensing circuits for multiwire proportional chambers

Integrated sensing circuits were designed, fabricated, and packaged for use in determining the direction and fluence of ionizing radiation passing through a multiwire proportional chamber. CMOS on sapphire was selected because of its high speed and low power capabilities. The design of the proposed circuits is described and the results of computer simulations are presented. The fabrication processes for the CMOS on sapphire sensing circuits and hybrid substrates are outlined. Several design options are described and the cost implications of each discussed. To be most effective, each chip should handle not more than 32 inputs, and should be mounted on its own hybrid substrate.

Peterson, H. T.↗

Precision capacitor has improved temperature and operational stability

Vacuum dielectric capacitor is fabricated from materials with very low temperature coefficients of expansion. This precision capacitor in the 1000-2000 picofarad range has a near-zero temperature coefficient of capacitance, eliminates ion chamber action caused by air ionization in the dielectric, and minimizes electromagnetic field charging effects.

Brookshier, W. K.↗

Measurements of Nitric Acid and Aerosol Species Aboard the NASA DC-8 Aircraft During the SASS Ozone and Nitrogen Oxide Experiment (SONEX)

The SASS Ozone and Nitrogen Oxides Experiment (SONEX) over the North Atlantic during October/November 1997 offered an excellent opportunity to examine the budget of total reactive nitrogen (NO(sub y)) in the upper troposphere (8 - 12 km altitude). The median measured NO(sub y) mixing ratio was 425 parts per trillion by volume (pptv). Two different methods were used to measure HNO3: (1) the mist chamber technique and, (2) chemical ionization mass spectrometry. Two merged data sets using these HNO3 measurements were used to calculate NO(sub y) by summing the reactive nitrogen species (a combination of measured plus modeled results) and comparing the resultant values to measured NO(sub y) (gold catalytic reduction method). Both comparisons showed good agreement in the two quantities (slope > 0.9 and r(exp 2) > 0.9). Thus, the total reactive nitrogen budget in the upper troposphere over the North Atlantic can be explained in a general manner as a simple mixture of NO(sub x). (NO + NO2), HNO3, and PAN. Median values of NO(sub x)/NO(sub y) were approximately equal to 0.25, HNO3/NO(sub y) were approximately equal to 0.35 and Peroxyacetyl Nitrate (PAN)/NO(sub y) were approximately equal to 0. 17. Particulate NO3 and alkyl nitrates together composed <10 % of NO(sub y), while model estimated HNO4 averaged 12%.

Talbot, Robert W.↗

Measurements of Nitric Acid and Aerosol Species Aboard the NASA DC-8 Aircraft During the SASS OZone and Nitrogen Oxide Experiment (SONEX)

The SASS Ozone and Nitrogen Oxides Experiment (SONEX) over the north Atlantic during October/November 1997 offered an excellent opportunity to examine the budget of total reactive nitrogen (NO(y)) in the upper troposphere (8 - 12 km altitude). The median measured NO(y) mixing ratio was 425 parts per trillion by volume (pptv). Two different methods were used to measure HNO3: (1) the mist chamber technique and, (2) chemical ionization mass spectrometry. Two merged data sets using these HNO3 measurements were used to calculate NO(y) by summing the reactive nitrogen species (a combination of measured plus modeled results) and comparing the resultant values to measured NO(y) (gold catalytic reduction method). Both comparisons showed good agreement in the two quantities (slope greater than 0.9 and r(sup 2) greater than 0.9). Thus, the total reactive nitrogen budget in the upper troposphere over the North Atlantic can be explained in a general manner as a simple mixture of NO(x). (NO + NO2), HNO3, and PAN. Median values of NO(x)/NO(y) were approx. = 0.25, HNO3/NO(y) approx. = 0.35 and PAN/NO(y) approx. = 0.17. Particulate NO3 and alkyl nitrates together composed less than 10% of NO(y), while model estimated HNO4 averaged 12%.

Talbot, Robert W.↗

Accelerator system and method of accelerating particles

An accelerator system and method that utilize dust as the primary mass flux for generating thrust are provided. The accelerator system can include an accelerator capable of operating in a self-neutralizing mode and having a discharge chamber and at least one ionizer capable of charging dust particles. The system can also include a dust particle feeder that is capable of introducing the dust particles into the accelerator. By applying a pulsed positive and negative charge voltage to the accelerator, the charged dust particles can be accelerated thereby generating thrust and neutralizing the accelerator system.

Wirz, Richard E.↗