Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser based measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Recent Progress in U-10Mo Mechanical and Thermophysical Property Characterization -- Poster

Results are presented on the mechanical and thermophysical property characterization of U-10Mo as part of the MP-1 qualification campaign. The thermal diffusivity, specific heat and thermal conductivity of as fabricated U-10Mo fuel foils and plates were measured using the thermal conductivity microscope (TCM), differential scanning calorimeter (DSC) and laser flash analyzer (LFA) all of which located in a shielded glove box – thermal property cell (TPC). A novel inverse method based on finite element analysis was developed to evaluate the thermal diffusivity of composite/layered materials via the LFA technique such as the 5-lyered U-10Mo monolithic fuel mini-plates.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Data-Driven Framework for Direct Local Tensile Property Prediction of Laser Powder Bed Fusion Parts

This article proposes a generalizable, data-driven framework for qualifying laser powder bed fusion additively manufactured parts using part-specific in situ data, including powder bed imaging, machine health sensors, and laser scan paths. To achieve part qualification without relying solely on statistical processes or feedstock control, a sequence of machine learning models was trained on 6299 tensile specimens to locally predict the tensile properties of stainless-steel parts based on fused multi-modal in situ sensor data and a priori information. A cyberphysical infrastructure enabled the robust spatial tracking of individual specimens, and computer vision techniques registered the ground truth tensile measurements to the in situ data. The co-registered 230 GB dataset used in this work has been publicly released and is available as a set of HDF5 files. The extensive training data requirements and wide range of size scales were addressed by combining deep learning, machine learning, and feature engineering algorithms in a relay. The trained models demonstrated a 61% error reduction in ultimate tensile strength predictions relative to estimates made without any in situ information. Lessons learned and potential improvements to the sensors and mechanical testing procedure are discussed.

36 MATERIALS SCIENCE↗

Optical diagnostics of laser-produced plasmas

Laser-produced plasmas (LPPs) engulf exotic and complex conditions ranging in temperature, density, pressure, magnetic and electric fields, charge states, charged particle kinetics, and gas-phase reactions, based on the irradiation conditions, target geometries, and the background cover gas. The application potential of the LPP is so diverse that it generates considerable interest for both basic and applied research areas. The fundamental research on LPPs can be traced back to the early 1960s, immediately after the invention of the laser. In the 1970s, the laser was identified as a tool to pursue inertial confinement fusion, and since then, several other technologies emerged out of LPPs. These applications prompted the development and adaptation of innovative diagnostic tools for understanding the fundamental nature and spatiotemporal properties of these complex systems. Although most of the traditional characterization techniques developed for other plasma sources can be used to characterize the LPPs, care must be taken to interpret the results because of their small size, transient nature, and inhomogeneities. The existence of the large spatiotemporal density and temperature gradients often necessitates non-uniform weighted averaging over distance and time. Among the various plasma characterization tools, optical-based diagnostic tools play a key role in the accurate measurements of LPP parameters. The optical toolbox contains optical spectroscopy (emission, absorption, and fluorescence), passive and active imaging and optical probing methods (shadowgraphy, Schlieren, interferometry, Thomson scattering, deflectometry, and velocimetry). Each technique is useful for measuring a specific property, and its use is limited to a certain time span during the LPP evolution because of the sensitivity issues related to the selected measuring tool. Therefore, multiple diagnostic tools are essential for a comprehensive insight into the entire plasma behavior. In recent times, the improvements in performance in the lasers and detector systems expanded the capability of the aforementioned passive and active diagnostics tools. Furthermore, this review provides an overview of optical diagnostic tools frequently employed for the characterization of the LPPs and emphasizes techniques, associated assumptions, and challenges. Considering most of the industrial and other applications of the LPP belong to low to moderate laser intensities (10 8 – 10 15 Wcm –2 ), this review focuses on diagnostic tools pertaining to this regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Damage Tolerance Assessment of Laser Clad Repairs of Coarse Grain Ti-6Al-4V

Background: Laser cladding offers a promising approach to repairing aviation components, with the ability to restore the geometric shape and the static and fatigue strength. Objective: The damage tolerance of a coarse grain Ti-6Al-4 V material is assessed via three sets of samples: (i) baseline, (ii) laser clad repaired, and (iii) laser cladding followed by heat treatment. Method: The specimens were subjected to fatigue loading using a marker band technique, in which cracks initiated from pre-defined laser slots and the small crack growth rates were measured by quantitative fractography. Additional characterization was performed on these samples, including hardness measurements, microstructure analysis, and multimodal residual stress analyses. Results: The region of the specimen undergoing laser cladding exhibited higher hardness values and a compressive residual stress, based on the slitting method. The samples subjected to heat treatment after cladding displayed negligible differences in grain size and minimal residual stress relaxation. Conclusions: The results demonstrated significant variability, with data demonstrating that cracks in the laser clad region (exhibiting the largest compressive residual stress) grew faster than cracks in the substrate region of the sample or in the baseline cases. Finally, these counterintuitive results are rationalized with additional analyses from synchrotron-based energy dispersive X-ray diffraction and high energy X-ray diffraction, demonstrating significant spatial variability in the residual elastic strains in the millimeter-sized prior β grains within the material.

36 MATERIALS SCIENCE↗

Laser ultrasonic imaging of subsurface defects with the linear sampling method

Laser ultrasonics is a remote nondestructive evaluation technique suitable for real-time monitoring of fabrication processes in semiconductor metrology, advanced manufacturing, and other applications where non-contact, high fidelity measurements are required. Here we investigate laser ultrasonic data processing approaches to reconstruct images of subsurface side drilled holes in aluminum alloy specimens. We demonstrate through simulation that the model-based linear sampling method (LSM) can perform accurate shape reconstruction of single and multiple holes and produce images with well-defined boundaries. We experimentally confirm that LSM produces images that represent the internal geometric features of an object, some of which may be missed by conventional imaging.

42 ENGINEERING↗

Coupling of a single tin-vacancy center to a photonic crystal cavity in diamond

In this work, we demonstrate optical coupling between a single tin-vacancy (SnV) center in diamond and a free-standing photonic crystal nanobeam cavity. The cavities are fabricated using quasi-isotropic etching and feature experimentally measured quality factors as high as ~11000. We investigate the dependence of a single SnV center's emission by controlling the cavity wavelength using a laser-induced gas desorption technique. Under resonance conditions, we observe an intensity enhancement of the SnV emission by a factor of 12 and a 16-fold reduction of the SnV lifetime. Based on the large enhancement of the SnV emission rate inside the cavity, we estimate the Purcell factor for the SnV zero-phonon line to be 37 and the coupling efficiency of the SnV center to the cavity, the β factor, to be 95%. Our work paves the way for the realization of quantum photonic devices and systems based on efficient photonic interfaces using the SnV color center in diamond.

42 ENGINEERING↗

Modeling and characterizing the elastodynamic response of octet-truss lattice structures using resonance techniques

Characterization of additively manufactured materials and structures is an ongoing effort for the advanced manufacturing community. This article will investigate an approach using resonant spectral ultrasound (RUS) to measure the effective elastic constants of an Octet Truss lattice and apply the results to continuum bases models representing the lattice regions in different structures. The study is focused on simple lattices structures fabricated from Ti5553 using a laser powder bed fusion process (LBPF). Solid and lattice samples are measured to determine RUS estimates for the elastic properties of the bulk material and the effective elastic properties of the lattice structure. The estimated elastic properties are then incorporated into 3d finite element models using a continuum approximation of the physical AM parts. Comparisons show good agreement between the experimentally measured eigen frequencies of the Ti5553 LBPF parts and the eigen frequencies calculated using the continuum approximations based on the effective RUS elastic properties. The current results suggest there is additional physics and geometrical effects that are accounted for in the RUS continuum approximation of the lattice that are not captured in the full 3d finite element model of the parts utilizing only the base material properties.

36 MATERIALS SCIENCE↗

Laser-induced fluorescence measurements of ion fluctuations in electron and ion presheaths

Electrostatic flow-driven instabilities have been predicted in the presheath region of low-temperature plasmas for both ion and electron rich sheaths. The ion-acoustic fluctuations that arise from these instabilities can influence transport through an enhanced collision rate. In this work, ion fluctuation spectra were measured using laser-induced fluorescence (LIF) in the presheath region for both sheath polarities. Furthermore, the non-invasive nature of LIF compared to that of probes is particularly valuable for these measurements because the sheath and presheath around a probe may generate their own flow-driven instabilities, which obscure the measurement. Measurements were made using a recently implemented field programmable gate array-based system able to measure ion fluctuation spectra up to 1 MHz using a two-point correlation function technique. Narrow bandwidth ion fluctuations were observed near 0:46 f pi (460 kHz) for both sheath polarities, where f pi is the ion plasma frequency. The observed fluctuations were significantly stronger in the electron sheath case and were observed over a larger volume of plasma. Fluctuations were measured in the ion sheath case at locations far enough from the sheath that linear theory predicts stability, suggesting that ion-acoustic instabilities generated in the relatively small unstable region near the boundary reflect from the sheath and perturb a much larger volume of the plasma. This is expected to affect probes with both ion and electron rich sheaths, meaning any dc biased probe may effectively act as an ion-acoustic wave antenna. These measurements are consistent with the recent theory and particle-in-cell results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra-Fast 4H-SiC LGAD With Etched Termination and Field Plate

The design, fabrication, and demonstration of a novel Silicon Carbide Low Gain Avalanche Detector (4HSiC LGAD), exhibiting an ultra-fast time response and excellent time resolution, are reported. Here, the use of field plates is proposed to suppress the high electric field caused by the negative bevel-etched angle in 4H-SiC LGADs based on TCAD simulations. Experimental measurements confirm that the field plate significantly increases the breakdown voltage of the 4H-SiC LGADs. Gain and time resolution are measured by using the ultraviolet transient current technique (UV-TCT) showing that 4H-SiC LGADs possess excellent timing performance, with a time resolution better than 35 ps for the injected laser signal with single minimum ionizing particle (MIP) charges generation at room temperature. Additionally, the gain suppression effect in a 4H-SiC LGAD is observed for the first time.

43 PARTICLE ACCELERATORS↗

Detection limits for laser absorption spectroscopy of Li in laser ablation plumes

A high-sensitivity laser absorption spectroscopy (LAS) method is demonstrated for rapid and non-contact analysis of Li in solids. Glass samples with Li concentrations ranging from 1-500 ppm by mass are ablated in 5 Torr air, and time-resolved Li atomic absorption is measured using a tunable laser near 671 nm. Significant improvements in analytical performance over prior laser-induced breakdown techniques are demonstrated. Here, a single-shot limit of detection (LOD) of 180 ppb is shown for fixed wavelength operation, improving to 6 ppb with averaging over 1000 ablation shots (100 s acquisition time). Isotope-resolved Li absorption spectra are measured with a 17 ppb LOD in 40 s. Methods for optimizing LOD based on noise/averaging properties of LAS experiments in LA plumes are discussed.

(020.3260) Isotope shifts↗

Laser-Induced Photoreduction of Iron(III) Oxide Nanoparticles Enhanced by the Presence of Organic Chromophores

Light-induced electron transfer between chromophoric organic matter and Fe(III)-oxides lies at the heart of aqueous Fe(II) fluxes in the photic zone of natural systems. Understanding this photoreductive dissolution process is also essential for developing water purification techniques based on this class of materials. Previously, optical transient absorption spectroscopy (TAS) measurements revealed that sub-picosecond relaxation times of photo-excited rhodamine B (RhB) dye increased when sorbed onto hematite nanoparticles (HNPs), consistent with electron transfer to the oxide. Here, in the present study, we exploit time-resolved X-ray absorption spectroscopy (XAS) at the Fe K-edge to follow the Fe oxidation state for this same process to (i) confirm that RhB photoexcitation leads to interfacial electron transfer and Fe reduction; and (ii) quantify the lifetime of injected electrons as a function of solution conditions. Regardless of RhB dye availability and pH, direct band gap photoexcitation of HNPs yields an Fe(II)-like small polaronic absorption signature with a lifetime of ~ 1 ns, an order of magnitude longer than previously reported. However, when RhB is present at low pH under conditions where dye favorably interacts with the positively charged hematite surface, a second relaxation process approaching microsecond timescales is observed that likely represents back-reaction with the photoexcited adsorbed dye. At pH above neutral, the efficiency of the interfacial electron transfer is diminished by weaker interaction between sorbed dye and particle surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Reaction of Atomic Hydrogen with an Imine: Direct Kinetic Measurements and Computational Studies

Imines are of interest in the combustion modeling of nitrogen-based fuels such as ammonia, as intermediates in atmospheric oxidation of amines, and may offer a new class of environmentally benign substitutes for perhalogenated reagents. Elementary gas-phase rate constants for the consumption of H atoms by 1,1,1,3,3,3-hexafluoro-2-propanimine were measured over 294–736 K using the laser flash photolysis/atomic resonance fluorescence technique. The results are summarized as 3.0 × 10 –11 exp(−14.5 kJ mol –1 /RT) cm 3 molecule –1 s –1 with a confidence interval of ±13%. These are the first temperature-dependent kinetic experiments on an imine of the form R 2 C═NH and thereby provide the only validation of transition-state modeling for such systems. Several pathways are feasible; comparison of theory and experiment suggests the dominant channel is addition of H atoms to the nitrogen atom. On this basis, the observations are rationalized quantitatively. Computations also yield the thermochemistry of (CF 3 ) 2 CNH, with Δ f H 298 = −1232 kJ mol –1 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plasma Mirrors For High Power Lasers: A new approach for high repetition rates combined with realistic PIC simulations

We describe a research program to develop high quality plasma mirrors for use with high repetition rate, high power laser facilities to greatly facilitate experiments in high energy density physics, particularly when using solid density targets. A system delivering ultrathin, free standing liquid crystal films that could handle PW class laser pulses was developed that preserved the laser beam image quality and improved pulse contrast by over two orders of magnitude. The pulse contrast improvement was measured using a high dynamic range cross-correlation. The system operated at a repetition rate of several PMs formed in situ per minute. Extension to 1 Hz repetition rates should be possible. As a practical application, a PM system was used to separate laser accelerated electrons from the ultrashort pulse drive laser so that the electron beam emittance could be directly measured. The 20 nm thick PMs did not contribute significantly to emittance degradation. It was also demonstrated that the films could operate in the difficult plasma and laser environment present for GeV laser based electron acceleration. PM operation is still not well understood and much work with PMs is done empirically. Accordingly, we also demonstrated a particle-in-cell based simulation technique that would model PM operation, tracking the PM operation from cold, neutral atoms to a hot dense plasma by accounting for multiphoton ionization, plasma collisionality, and the dynamically changing index of refraction. Simulations in 3D were compared to a 2D based approach that was comparable. Finally, we developed a simpler model that can predict the intensity at which a plasma mirror will have its peak reflectivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fiber-Coupled Multipass NIR Sensor for In Situ, Real-Time Water Vapor Outgassing Monitoring

This work presents the recent development of a fiber-coupled multipass near-infrared (NIR) gas sensor used to monitor water vapor desorption of small material coupons. The gas sensor design employs a White cell topology to maximize the optical path length over a compact, hand-size footprint. Water vapor concentrations are quantified over a large dynamic range by simultaneously applying wavelength modulation and tunable diode laser absorption spectroscopy techniques. A custom headspace optimized for material desorption experiments is assembled using commercially available vacuum chamber components. We provide in situ measurements of water vapor desorption from two geometries of the industrially important silicone elastomer Sylgard-184 as a case study for sensor viability. To corroborate the results, the gas sensor data are compared to numerical simulations based on a triple-mode diffusion–sorption model, consisting of Henry, Langmuir, and Pooling modes.

gas sensor↗

Predicting Local Material Thickness from Steady-State Ultrasonic Wavefield Measurements Using a Convolutional Neural Network

Acoustic steady-state excitation spatial spectroscopy (ASSESS) is a full-field, ultrasonic non-destructive evaluation (NDE) technique used to locate and characterize defects in plate-like structures. ASSESS generates a steady-state, single-tone ultrasonic excitation in a structure and a scanning laser Doppler Vibrometer (LDV) measures the resulting full-field surface velocity response. Traditional processing techniques for ASSESS data rely on wavenumber domain analysis. This paper presents the alternative use of a convolutional neural network (CNN), trained using simulated ASSESS data, to predict the local plate thickness at every pixel in the wavefield measurement directly. The defect detection accuracy of CNN-based thickness predictions are shown to improve for defects of greater size, and for defects with higher thickness reductions. The CNN demonstrates the ability to predict thickness accurately in regions where Lamb wave dispersion relations are complex or unknown, such as near the boundaries of a test specimen, so long as the CNN is trained on data that accounts for these regions. The CNN also shows generalizability to ASSESS experimental data, despite an entirely simulated training dataset.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Smooth trends in fermium charge radii and the impact of shell effects

The quantum-mechanical nuclear-shell structure determines the stability and limits of the existence of the heaviest nuclides with large proton numbers Z ≳ 100. Shell effects also affect the sizes and shapes of atomic nuclei, as shown by laser spectroscopy studies in lighter nuclides. However, experimental information on the charge radii and the nuclear moments of the heavy actinide elements, which link the heaviest naturally abundant nuclides with artificially produced superheavy elements, is sparse. Here we present laser spectroscopy measurements along the fermium (Z = 100) isotopic chain and an extension of data in the nobelium isotopic chain (Z = 102) across a key region. Multiple production schemes and different advanced techniques were applied to determine the isotope shifts in atomic transitions, from which changes in the nuclear mean-square charge radii were extracted. A range of nuclear models based on energy density functionals reproduce well the observed smooth evolution of the nuclear size. Both the remarkable consistency of model prediction and the similarity of predictions for different isotopes suggest a transition to a regime in which shell effects have a diminished effect on the size compared with lighter nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Standoff Infrared Measurements of Chemical Plume Dynamics in Complex Terrain Using a Combination of Active Swept-ECQCL Laser Spectroscopy with Passive Hyperspectral Imaging

Chemical plume detection and modeling in complex terrain present numerous challenges. We present experimental results from outdoor releases of two chemical tracers (sulfur hexafluoride and Freon-152a) from different locations in mountainous terrain. Chemical plumes were detected using two standoff instruments collocated at a distance of 1.5 km from the plume releases. A passive long-wave infrared hyperspectral imaging system was used to show time- and space-resolved plume transport in regions near the source. An active infrared swept-wavelength external cavity quantum cascade laser system was used in a standoff configuration to measure quantitative chemical column densities with high time resolution and high sensitivity along a single measurement path. Both instruments provided chemical-specific detection of the plumes and provided complementary information over different temporal and spatial scales. The results show highly variable plume propagation dynamics near the release points, strongly dependent on the local topography and winds. Effects of plume stagnation, plume splitting, and plume mixing were all observed and are explained based on local topographic and wind conditions. Measured plume column densities at distances ~100 m from the release point show temporal fluctuations over ~1 s time scales and spatial variations over ~1 m length scales. The results highlight the need for high-speed and spatially resolved measurement techniques to provide validation data at the relevant spatial and temporal scales required for high-fidelity terrain-aware microscale plume propagation models.

47 OTHER INSTRUMENTATION↗

Polyvinyl acetate-based polymer host for optical and far-infrared spectroscopy of individualized nanoparticles

Preparation techniques for producing films of individualized solution-dispersed nanoparticles (NPs) for optical spectroscopy are frequently technically challenging and tailored for a specific NP system. In this work, we present a rapid, easy, and economical technique for producing polyvinyl acetate (PVAc)-based NP-polymer films on the order of 100’s of micrometers thick that exhibit high uniformity, low aggregation, excellent optical transparency, and low terahertz absorption. In addition, we find that these films are robust at cryogenic temperatures and have a high laser damage threshold of 0.3 TW cm –2 , which make them suitable for pulsed laser measurements. We show that free-standing, flexible, PVAc films can incorporate both one-dimensional single-wall carbon nanotubes (SWCNTs) and zero-dimensional Au NPs. Using absorbance, Raman scattering, and photoluminescence excitation spectroscopy, we observe that SWCNT individualization is maintained, and minimized polymer strain imposed, when the nanotubes are transitioned from the solution to the polymer host. This PVAc-based polymer host presents researchers with a straightforward method for producing free-standing and flexible NP films with low aggregation.

36 MATERIALS SCIENCE↗