TORONE: Total Characterisation by Remote Observation of Nuclear Environments - 20591

This paper describes the autonomous robotic systems developed in the TORONE project (Total Characterisation by Remote Observation of Nuclear Environments) for combined characterisation by remote techniques in nuclear environments. There are four main components to the system. Firstly, robot operation which uses a Robot Operating System (ROS) allowing ease of communication between hardware and software alongside robot vision systems such as Lidar and/or photogrammetry. Secondly, radiation detection instrumentation for gamma and neutron sources which is also collimated for spatial resolution. Thirdly, photonic characterisation instrumentation for remote material identification by means of Raman spectroscopy and Laser induced breakdown spectroscopy (LIBS). Finally, a data management system is described which contains the TORONE characterisation data with the ability to overlay material characterisation information onto 3D maps of the nuclear environment. Preliminary results are described alongside discussion of some of the synergies of the combined approach. There are many applications of such an autonomous system in nuclear decommissioning, waste management and asset management. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Overview of the Hybrid Illinois Device for Research and Applications Material Analysis Test-stand (HIDRA-MAT)

The Hybrid Illinois Device for Research and Applications (HIDRA) at the University of Illinois at Urbana-Champaign is a toroidal plasma device that enables fusion plasma-material interaction testing with both stellarator and tokamak plasmas. HIDRA’s long-pulse steady state stellarator plasmas provide a testbed for plasma facing component (PFC) plasma exposures. The HIDRA Material Analysis Test-stand (HIDRA-MAT) is a material characterization module attached to HIDRA that is being designed and fabricated to include thermal desorption spectroscopy and laser induced breakdown spectroscopy systems for in-vacuo PFC characterization. A specialized rotatable sample holder positions the sample for liquid metal droplet application from a liquid metal droplet injector on HIDRA-MAT. Early experiments look to investigate the effect liquid lithium has on porous tungsten samples’ retention of H, D, and He after plasma exposure. Preliminary results from a dual residual gas analyzer system show the ability to differentiate D2 and He in HIDRA-MAT. Finally, this work aims to advance the understanding of liquid metal PFCs and further the design and development of new fusion PFCs and technologies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Spectroscopic Tools for Nuclear Forensics Signatures Development

Diversion of nuclear materialsfrom legitimate commercial processes for use by nefarious actors is a frightening and surreptitious problem. Smuggled nuclear material can be used to manufacture a simple radiological dispersion device (RDD) and potentially incorporated into the development of a nuclear weapon. With some frequency, smuggled nuclear material is interdicted in foreign countries as actors cross border checkpoints. Nuclear material interdicted in this way can be analyzed using a variety of tools. Plutonium-239 is commonly used as the fissile material in nuclear weapon production as an alternative to uranium-235. Plutonium in a production, refining, or finishing facility will exist in many forms including oxide precursors (PuF4, PuF3, Pu oxalate, etc.), oxide, and metal. The ability to identify plutonium in each of these forms and determine properties, characteristics, or history of these materials is crucial for determining if the processes occurring in a nuclear facility are legitimate or not. This presentation will focus on the development and application ofspectroscopic tools developed at SRNL using doubled-walled cells (DWC) to characterize Pu-bearing compounds. Advances in the use of vibrational spectroscopy techniques (Raman and IR), UV-VIS-SWIR diffuse reflectance spectroscopy, gamma emission spectroscopy, luminescence spectroscopy, laser-induced breakdown spectroscopy in conjunction with XRD and SEM in the characterization of Pu-bearing compounds will be presented with emphasis in material processing history.

Villa-Aleman, Eliel↗

Composition and Density Stratification Observed by SuperCam in the First 300 Sols in Jezero Crater

The Perseverance rover has traveled > 2.5 km since leaving its Octavia Butler landing site in Jezero crater ~300 sols ago. The SuperCam remote sensing instrument suite has made > 1000 observations of bedrock along the traverse to provide a comprehensive picture of Jezero crater floor’s chemistry and mineralogy. SuperCam combines high resolution imaging, visible and near-infrared (VISIR) reflectance spectroscopy (0.4-0.85, 1.3-2.6 µm), remote time-resolved green-laser Raman and fluorescence spectroscopy, laser-induced breakdown spectroscopy (LIBS), and acoustic sensing into a single co-boresighted package [1, 2]. Derivation of the major element abundances as oxide wt% for this part of the mission is presented in [3], while calibration of the VIS and IR spectrometers are given in [4-7].

R.C. Wiens↗

Optical Spectroscopy of Venus Aerosol Analogs and Substrate Survivability

Aerosol Rapid Analysis Combined Entry Probe/Sonde Technology (AERACEPT) is a dual descent probe and in-situ sampler of cloud and aerosol particles, used as part of the Nephele mission concept to study Venus cloud layers. Various optical spectroscopic characterization methods, including Raman spectroscopy and Surface Enhanced Raman Spectroscopy (SERS), Laser induced Breakdown Spectroscopy (LIBS), and absorbance and fluorescence spectroscopy are being assessed for viability for compatibility with AERACEPT. Specifically, the detection limits, sensitivity, specificity, and analysis cadence of these techniques for a set of Venus aerosol analogs and their mixtures are tested. We report on preliminary optical spectroscopy results of the Venus aerosol analogs, as well as optical substrate survivability in heated and acidic conditions, substrate physical robustness, and analyte wettability on substrates.

Venus↗

Double-walled containment cell

Double-walled containment cells are described as may be used for storage, transport, and examination of a sample held within the cell by use of optical analysis techniques. A double-walled containment cell can include multiple types of windows that can be located as desired on the containment cells and thereby provide for optical access to a sample for multiple optical analysis techniques. Disclosed containment cells can be sized and designed for use with existing optical analysis systems, e.g., laser ablation, X-ray diffraction, spectral analysis (e.g., Raman spectroscopy, infrared spectroscopy, laser-induced breakdown spectroscopy, etc.), imaging analysis, etc.

Villa-Aleman, Eliel↗

LIBS Applications to Liquids and Solids in Liquids

In this chapter, LIBS instrumentation and data collection system used for the analysis of liquids and solids in liquids are discussed. LIBS measurements of bulk liquid samples and solids submerged in aqueous media, measurements made by focusing laser pulses on liquid surfaces, and measurements of liquids after various sample treatments are presented. In addition, the working mechanism of NETL‐developed field‐deployable LIBS sensor and its preliminary performance in field measurements are also reported.

atomic emission spectroscopy↗

Exploration of a Combined LIBS and LA-ICP-MS Approach for Apatite Characterisation

A combined laser‐induced breakdown spectroscopy (LIBS) and laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) method is demonstrated for comprehensive apatite analysis. These measurements provide elemental imaging that can be used as a screening technique for chemical selection of grains for subsequent analysis (e.g., U‐Pb geochronology) or can be used to understand elemental distributions within a single grain that would have direct textural‐chemical implications (e.g., zoning patterns). Adding LIBS as a simultaneous measurement, to LA‐ICP‐MS U‐Pb geochronology, allowed for the direct determination of F (H and O show promise for future applications) in addition to major and trace elements of interest. Here, the quantitative measurements were validated against a series of apatites with known values and used to characterise a wide range of samples. Fluorine detection limits were determined to be as low as 70 μg g ‐1 F (broadband CMOS detector) and 4.2 μg g ‐1 F (ICCD detector). U‐Pb age dating was simultaneously collected by LA‐ICP‐MS with the quantitative elemental data from LIBS, providing a comprehensive method for geochronology.

Apatite↗

Sodium tracer measurements of an expanded dense aluminum plasma from e-beam isochoric heating

Spatially and temporally resolved visible absorption spectroscopy is performed on sodium D-lines present as surface contaminants on an expanded dense aluminum plasma plume. An 80-ns FWHM, intense, relativistic electron beam deposits 5.4 J into a 100- μ m-thick Al foil, which isochorically heats and subsequently hydrodynamically expands the material through the warm dense matter state and into a classical-like plasma state, with a coupling parameter of approximately 0.2 and a degeneracy parameter of approximately 270. The Na contamination, carried along with the expanding plume, shows saturated absorption features in the dense Al continuum for λ > 450 nm. X-ray photoelectron spectroscopy and laser-induced breakdown spectroscopy confirm Na is a surface contaminant with an atomic concentration of ~ 0.1 % when interrogating identical foil samples. Additioanlly, a spectroscopic-quality radiation transport model is used to post-process 2D hydrodynamic simulations to interpret the plasma conditions based on the measured Na 3p-3s doublet line profiles. A sodium number density of 3 × 10 15 cm -3 best matches the experimental spectra, which originate from a dense surface plasma with n e = 3.0 ± 0.8 × 10 18 cm -3 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of ambient gas on self-reversal in Li transitions relevant to isotopic analysis

Laser induced breakdown spectroscopy is a promising, rapid analysis method for the detection and quantification of Li and its isotopes needed in geochemical, nuclear, and energy storage applications. However, spectral broadening in laser produced plasmas, presence of fine and hyperfine structures, and self-reversal effects make Li isotopic analysis via laser induced breakdown spectroscopy challenging. The present study explores the influence of Ar, N 2 , and He ambient gases over the pressure range of 0.05 - 100 Torr on line broadening and self-reversal of the Li I transition with the greatest isotopic shift in the VIS spectral region (i.e., ≈670.8 nm, ≈15.8 pm isotopic shift). We perform spatially and temporally resolved optical emission spectroscopy of plasmas produced via laser ablation of LiAlO 2 substrates. Our results show that the self-reversal and linewidth is reduced at lower pressures for all gases, and using optimized plasma conditions with chemometric methods, the 6 Li/ 7 Li isotopic ratios can be predicted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatiotemporal Plasma-Particle Characterization of Dry Aerosols Using Nanosecond, Femtosecond, and Filament Laser-Produced Plasmas

The ability to rapidly characterize dry aerosols in air using laser-induced breakdown spectroscopy (LIBS) with femtosecond laser pulses promises advancement towards real-time atmospheric sampling and standoff capabilities. Of particular interest is the ability to apply LIBS in the context of low-particle loaded environments where discrete particle interactions must be observed within the sampling volume of the laser-produced plasma (LPP). In this study, dry nanoparticles in suspension are generated from a standard solution and sampled in air using Q-switched nanosecond (ns-) pulses, short-focus (SF) femtosecond (fs-) pulses, and filaments. Short time-gated plasma images are captured to observe spatially and temporally varying discrete plasma-particle interactions, which is shown to influence early air breakdown behavior and subsequent plasma evolution. Along with images, photo-multiplier tube (PMT) measurements are conducted where strong spatiotemporal dependencies are exhibited by the collected emission signal on particle proximity and plasma expansion behavior. Finally, conditional analysis is performed on LIBS measurements to determine associated sampling probabilities and filter out spectra with poor or absent emission peaks with an adaptive threshold algorithm.

42 ENGINEERING↗

Spectroscopic signatures and oxidation characteristics of nanosecond laser-induced cerium plasmas

Improving technologies related to the wide area environmental sampling of nuclear materials supports the nuclear nonproliferation mission of preventing the proliferation of nuclear weapons by monitoring nuclear weapons tests and detecting undeclared nuclear fuel cycle activities. Standoff, laser-based detection techniques such as laser-induced breakdown spectroscopy have the potential to offer robust, field-deployable methods that provide rapid element-specific and phase identifiable measurements over a wide range of materials. This work aims to elucidate the effects of atmospheric conditions and oxidation reactions on the highly complex and transient spectroscopic signatures of laser-induced plutonium surrogate plasmas. Time-resolved spectra of nanosecond laser ablation cerium plasmas were measured using laser-induced breakdown spectroscopy in a range of atmospheres containing low to high concentrations of oxygen. Here, the growth of strong CeO molecular emission bands was observed in the visible spectrum, where it was shown that the persistence of CeO is reduced from around 60 μs to 50 μs in oxygen rich atmospheric environments. To further investigate the growth and depletion of CeO in the laser-produced plasma, ratios of CeO-to-Ce emission were generated using integrated intensities corresponding to the Q-branch of the CeO D 1 -X 1 transitions and numerous strong atomic Ce peaks. It was determined that the fastest rate of formation of CeO in argon occurred for moderate oxygen mass fractions between 0.10 and 0.15 while the ratios were reduced at higher oxygen mass fractions (i.e., Y O 2 = 0.20) due to competing oxidation reactions and lower plasma temperatures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Expansion dynamics and chemistry evolution in ultrafast laser filament produced plasmas

Laser ablation in conjunction with optical emission spectroscopy is a potential non-contact, standoff detection method for all elements in the periodic table and certain isotopes such as radionuclides. Currently, significant development efforts are on-going to use ultrafast laser filaments for remote sensing. The application of filaments is of particular interest in extending the range of stand-off capability associated with elemental and isotopic detection via laser-induced breakdown spectroscopy. In this study, we characterize the expansion dynamics and chemical evolution of filament-produced uranium (U) plasmas. Laser filaments are generated in the laboratory by loosely focusing 35 femtosecond (fs), 6 milli Joule (mJ) pulses in air. Two-dimensional spectrally-integrated and time-resolved imaging was performed to study hydrodynamics and evolution of U atomic and UO molecular emission in filament-produced U plasmas. Our results highlight that filament ablation of U plasmas gives a cylindrical plasma plume morphology with an appearance of plume splitting into slow and fast moving components at later times of its evolution. Emission from the slow-moving region shows no distinct spectral features (i.e. broadband-like) and is contributed in part by nanoparticles generated during ultrafast laser ablation. Additionally, we find U atoms and U oxide molecules (i.e. UO, UxOy) co-exist in the filament produced plasma, which can be attributed to the generation of low-temperature plasma conditions during filament ablation

(140.3440) Laser-induced breakdown, (280.5395) Pla↗

Evaluating Optical Techniques to Characterize Solid State Samples for the Pu-238 Supply Program

This report documents steps that have been taken to establish advanced characterization capabilities for solid-state samples to support the 238 Pu Supply Program. The program has already invested significantly in spectroscopy and online monitoring development for liquid processes. Many of the data, analytical methods, and equipment could also be leveraged for the analysis of Np/Pu oxides and Np pellets to help classify material properties and link them to operations. The techniques described in this work include diffuse reflectance spectroscopy (DRS), Raman spectroscopy, and laser-induced breakdown spectroscopy (LIBS). Each technique is sensitive to various chemical and/or elemental species and can provide complimentary information to more standard methods such as powder x-ray diffraction and scanning electron microscopy. These options are remotely deployable via fiber-optic cables. DRS and Raman spectroscopy are already approved for glove box and hot cell work, but LIBS requires US Department of Energy approval for incorporation. Raman spectroscopy does require laser shielding, which means that DRS is the easiest method to implement. However, each technique provides complimentary data, and the most robust sample characterization could be achieved when all three, among other methods, are harnessed together. This report documents some of the progress made testing these capabilities, some of the challenges, and next steps to optimize the technology and integration strategies.

07 ISOTOPE AND RADIATION SOURCES↗

Online monitoring of lanthanide species with combined spectroscopy in flowing aqueous aerosol systems

Combined spectroscopic analysis through absorption and laser-induced breakdown spectroscopy (LIBS) was used to monitor Nd and Pr concentrations in a flowing aqueous system. A unique, online sampling approach was employed that allowed for an approximately closed analysis loop of liquids from a reservoir. Absorption spectroscopy was performed with an optical flow cell, and LIBS was performed on an aerosol stream. Multivariate calibrations based on combined absorption and LIBS signals were built for Nd and Pr and then used to monitor concentrations in mixed solutions in a series of spiking tests. In these tests, the concentrations of Nd and Pr in solution were intermittently changed while spectroscopic signals were monitored in real-time. The combined spectroscopic signals and multivariate models were successful in monitoring changing concentrations of lanthanide species with high accuracy and minimal latency. Root-mean squared error of predictions were 0.015 mol L −1 and 0.019 mol L −1 for Nd and Pr respectively, and these lanthanides were able to be monitored to an accuracy of < 0.2 wt%. This work demonstrates both the capabilities of a sampling system for online analysis of liquids and the capabilities of multimodal spectroscopic characterization for real-time, continuous tracking of species in potentially hazardous liquid systems.

absorbance spectroscopy↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Elemental analysis of air-sensitive frozen molten salt samples using an inert transfer chamber for LIBS/LA-ICP-TOF-MS analysis

A novel inert sample transfer system was developed and employed to enable, for the first time, the analysis of air-sensitive salt samples in a two-volume ablation cell using simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA)-inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) analysis. Molten salts are of growing interest as a medium for advanced nuclear reactors and nuclear fuel reprocessing technologies continue to be developed around their use. However, compositional analysis of molten salt samples can be challenging because of their air-sensitive nature and varying solubilities leading to inaccurate measurements when digested. LA-based analysis provides an alternate method to digestion and can provide rapid elemental information with little sample preparation. In this study, LIBS and LA-ICP-TOF-MS were used to analyze the Ce content in frozen salt samples taken from a series of electrochemical experiments. Calibrations were built for each technique, and the resulting limits of detection for Ce were estimated to be 107 and 58 µg g −1 for LIBS and LA-ICP-TOF-MS, respectively. Test samples from the electrochemical experiments were analyzed using these calibrations. The results matched bulk digestion-based ICP-optical emission spectroscopy values, and daily trends in Ce concentration changes were identified. Additionally, the LIBS and LA-ICP-TOF-MS analysis was demonstrated for identifying microgram per gram levels of components and detecting trace contaminants. The impurities detected by LIBS included Al, Mg, Ca, and Na. The impurities detected by LA-ICP-TOF-MS included W, Ag, Al, Fe, Ni, Mo, Nd, Sm, Th, and U.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Method and apparatus for chemical and topographical microanalysis

A scanning probe microscope is combined with a laser induced breakdown spectrometer to provide spatially resolved chemical analysis of the surface correlated with the surface topography. Topographical analysis is achieved by scanning a sharp probe across the sample at constant distance from the surface. Chemical analysis is achieved by the means of laser induced breakdown spectroscopy by delivering pulsed laser radiation to the sample surface through the same sharp probe, and consequent collection and analysis of emission spectra from plasma generated on the sample by the laser radiation. The method comprises performing microtopographical analysis of the sample with a scanning probe, selecting a scanned topological site on the sample, generating a plasma plume at the selected scanned topological site, and measuring a spectrum of optical emission from the plasma at the selected scanned topological site. The apparatus comprises a scanning probe, a pulsed laser optically coupled to the probe, an optical spectrometer, and a controller coupled to the scanner, laser and spectrometer for controlling the operation of the scanner, laser and spectrometer. The probe and scanner are used for topographical profiling the sample. The probe is also used for laser radiation delivery to the sample for generating a plasma plume from the sample. Optical emission from the plasma plume is collected and delivered to the optical spectrometer so that analysis of emission spectrum by the optical spectrometer allows for identification of chemical composition of the sample at user selected sites.

Kossakovski, Dmitri A.↗