Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Resonance ionization mass spectrometry for isotopic abundance measurements

Resonance ionization mass spectrometry (RIMS) is a relatively new laser-based technique for the determination of isotopic abundances. The resonance ionization process depends upon the stepwise absorption of photons from the laser, promoting atoms of the element of interest through progressively higher electronic states until an ion is formed. Sensitivity arises from the efficiency of the resonant absorption process when coupled with the power available from commercial laser sources. Selectivity derives naturally from the distinct electronic structure of different elements. This isobaric discrimination has provided the major impetus for development of the technique. Resonance ionization mass spectrometry was used for analysis of the isotopic abundances of the rare earth lutetium. Isobaric interferences from ytterbium severely effect the ability to measure small amounts of the neutron-deficient Lu isotopes by conventional mass spectrometric techniques. Resonance ionization for lutetium is performed using a continuous-wave laser operating at 452 nm, through a sequential two-photon process, with one photon exciting the intermediate resonance and the second photon causing ionization. Ion yields for microgram-sized quantities of lutetium lie between 10(6) and 10(7) ions per second, at overall ionization efficiencies approaching 10(-4). Discrimination factors against ytterbium greater than 10(6) have been measured. Resonance ionization for technetium is also being explored, again in response to an isobaric interference, molybdenum. Because of the relatively high ionization potential for Tc, three-photon, two-color RIMS processes are being developed.

Miller, C. M.↗

In Situ Geochemical Analysis and Age Dating of Rocks Using Laser Ablation-Miniature Mass Spectrometer

A miniaturized instrument for performing chemical and isotopic analysis of rocks has been developed. The rock sample is ablated by a laser and the neutral species produced are analyzed using the JPL-invented miniature mass spectrometer. The direct sampling of neutral ablated material and the simultaneous measurement of all the elemental and isotopic species are the novelties of this method. In this laser ablation-miniature mass spectrometer (LA-MMS) method, the ablated neutral atoms are led into the electron impact ionization source of the MMS, where they are ionized by a 70-eV electron beam. This results in a secondary ion pulse typically 10-100 microsecond wide, compared to the original 5-10-nanosecond laser pulse duration. Ions of different masses are then spatially dispersed along the focal plane of the magnetic sector of the miniature mass spectrometer and measured in parallel by a modified CCD (charge-coupled device) array detector capable of detecting ions directly. Compared to conventional scanning techniques, simultaneous measurement of the ion pulse along the focal plane effectively offers a 100% duty cycle over a wide mass range. LAMMS offers a more quantitative assessment of elemental composition than techniques that detect laser-ionized species produced directly in the ablation process because the latter can be strongly influenced by matrix effects that vary with the structure and geometry of the surface, the laser beam, and the ionization energies of the elements. The measurement of high-precision isotopic ratios and elemental composition of different rock minerals by LAMMS method has been demonstrated. The LA-MMS can be applied for the absolute age determination of rocks. There is no such instrument available presently in a miniaturized version that can be used for NASA space missions. Work is in progress in the laboratory for geochronology of rocks using LA-MMS that is based on K-Ar radiogenic dating technique.

Sinha, Mahadeva P.↗

Versatile tape-drive target for high-repetition-rate laser-driven proton acceleration

We present the development and characterization of a high-stability, multi-material, multi-thickness tape-drive target for laser-driven acceleration at repetition rates of up to 100 Hz. The tape surface position was measured to be stable on the sub-micrometre scale, compatible with the high-numerical aperture focusing geometries required to achieve relativistic intensity interactions with the pulse energy available in current multi-Hz and near-future higher repetition-rate lasers ( > kHz). Long-term drift was characterized at 100 Hz demonstrating suitability for operation over extended periods. The target was continuously operated at up to 5 Hz in a recent experiment for 70,000 shots without intervention by the experimental team, with the exception of tape replacement, producing the largest data-set of relativistically intense laser–solid foil measurements to date. This tape drive provides robust targetry for the generation and study of high-repetition-rate ion beams using next-generation high-power laser systems, also enabling wider applications of laser-driven proton sources.

47 OTHER INSTRUMENTATION↗

Imaging broadband soft X-ray transmission-grating spectrograph for a wavelength range λ > 111 Å

A family of aperiodic Mo/Be multilayer mirrors was designed for maximum uniform reflectivity in the ranges 111 – 138, 111 – 150, 111 – 200 and 111 – 222 Å at normal radiation incidence. The simulations took into account the existence of Mo-on-Be and Be-on-Mo transition layers. It was shown that the reflectivity may be as high as 10% in an octave wavelength range of 111 – 222 Å. We demonstrate the operation of an imaging transmission-grating spectrograph with a broadband Mo/Be multilayer mirror with a uniform reflectivity in the wavelength range 111 – 138 Å synthesised at the Institute for the Physics of Microstructures, RAS. The spectrograph was used to record the line spectra of multiply charged fluorine and magnesium ions from a laser-produced plasma. The role of the grating support structure in the formation of spectral source images is discussed. The spatial resolution of 50 μm is demonstrated. (laser applications and other topics in quantum electronics)

36 MATERIALS SCIENCE↗

Multi-Probe 24A: Post shot Data and Analysis

The Multi-Probe 24A experiments took place on the Omega EP laser in November 2023. The experiments consisted of shots alternating between Omega EP’s two short-pulse laser beams to generate proton and deuteron ion beams from a range of film thicknesses, and x-ray sources from the established CPC+Ta wire targets. The backlighter was used for ion acceleration in the pitcher series, in which deuteron and proton beams characterized as a function of CD film thickness to develop a pitcher for a pitcher-catcher neutron radiographic source, while also characterizing electrons and x-rays emitted perpendicular to the target (i.e. Crosstalk for sidelighter-driven x-ray beams). The sidelighter was used for electron acceleration in the x-ray series, in which the electron acceleration and subsequent x-rays was characterized from the CPC+Ta wire targets and radiography was conducted with and without electro-magnetic electron defection. For the pitcher series, we found that at 500 J and 0.7 ps the 700-800 nm CD films yielded the greatest number and highest energy for both protons and deuterons. For the x-ray series, results demonstrated: a significant number of <100 keV x-rays are produced within the glue that fills the CPC cone, on-axis electron signal from the x-ray targets produce electrons resolvable up to ~10 MeV, and electron deflection (using MIFEDS) has a notable effect radiograph on noise reduction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tunable far infrared laser spectrometers

The state of the art in far infrared (FIR) spectroscopy is reviewed. The development of tunable, coherent FIR radiation sources is discussed. Applications of tunable FIR laser spectrometers for measurement of rotational spectra and dipole moments of molecular ions and free radicals, vibration-rotation-tunneling spectra of weakly bound complexes, and vibration-rotation spectra of linear carbon clusters are presented. A detailed description of the Berkeley tunable FIR laser spectrometers is presented.

Blake, G. A.↗

Measurements of soot formation and hydroxyl concentration in near critical equivalence ratio premixed ethylene flame

The testing and development of existing global and detailed chemical kinetic models for soot formation requires measurements of soot and radical concentrations in flames. A clearer understanding of soot particle inception relies upon the evaluation and refinement of these models in comparison with such measurements. We present measurements of soot formation and hydroxyl (OH) concentration in sequences of flat premixed atmospheric-pressure C2H4/O2/N2 flames and 80-torr C2H4/O2 flames for a unique range of equivalence ratios bracketting the critical equivalence ratio (phi(sub c)) and extending to more heavily sooting conditions. Soot volume fraction and number density profiles are measured using a laser scattering-extinction apparatus capable of resolving a 0.1 percent absorption. Hydroxyl number density profiles are measured using laser-induced fluorescence (LIF) with broadband detection. Temperature profiles are obtained from Rayleigh scattering measurements. The relative volume fraction and number density profiles of the richer sooting flames exhibit the expected trends in soot formation. In near-phi(sub c) visibility sooting flames, particle scattering and extinction are not detected, but an LIF signal due to polycyclic aromatic hydrocarbons (PAH's) can be detected upon excitation with an argon-ion laser. A linear correlation between the argon-ion LIF and the soot volume fraction implies a common mechanistic source for the growth of PAH's and soot particles. The peak OH number density in both the atmospheric and 80-torr flames declines with increasing equivalence ratio, but the profile shape remains unchanged in the transition to sooting, implying that the primary reaction pathways for OH remain unchanged over this transition. Chemical kinetic modeling is demonstrated by comparing predictions using two current reaction mechanisms with the atmospheric flame data. The measured and predicted OH number density profiles show good agreement. The predicted benzene number density profiles correlate with the measured trends in soot formation, although anomalies in the benzene profiles for the richer and cooler sooting flames suggest a need for the inclusion of benzene oxidation reactions.

Inbody, Michael Andrew↗

Generation Of 369.4-Nanometers Second Harmonic From A Diode Laser

Experimental laser system features polarization feedback scheme maintaining frequency lock. Generates light at wavelength of 369.4 nanometers by second-harmonic generation from 738.8-nanometers laser diode. System prototype of source of 369.4-nanometers radiation used to optically pump 2S1/2 ' 2P1/2 transition in 171Yb+ ions in lightweight, low-power trapped-ion frequency-standard apparatus.

Williams, Angelyn P.↗

OzMALDI: A Gas-Phase, In-Source Ozonolysis Reaction for Efficient Double-Bond Assignment in Mass Spectrometry Imaging with Matrix-Assisted Laser Desorption/Ionization

Lipids make up an important class of biomolecules with diverse structures and varied chemical functions. This diversity is a major challenge in chemical analysis and limits our understanding of biological functions and regulation. A major way lipid isomers differ is by double-bond (db) position, and analyzing db-isomers is especially challenging for mass spectrometry imaging (MSI). Ozonolysis can be used to determine the dbposition and has been paired with MSI before. However, previous techniques require increased analysis time to allow for gas-phase reactions within an ion trap or ion mobility cell or additional sample preparation time to allow for offline ozonation. Here, we introduce a new ozonolysis method inside the matrix-assisted laser desorption-ionization (MALDI) source, termed OzMALDI, that simultaneously produces ozonides from all unsaturated lipids. This allows us to determine db-positions without adding additional reaction time while maintaining the high mass resolution provided by Orbitrap MS. This new technique is especially effective at determining multiple db-positions in lipids containing polyunsaturated fatty acids, which is a limitation of many previous techniques. OzMALDI-MSI was applied to the analysis of rat brain and genetically engineered Camelina and soybean seed samples, demonstrating the utility of this method and uncovering novel biological information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-yield and high-angular-fluence neutron generation from deuterons accelerated by laser-driven collisionless shock

Since a bright collimated neutron source is an essential tool for global security missions and fundamental scientific research. In this paper, we study a compact high-yield and high-angular-fluence neutron source particularly suitable for high-energy neutron applications utilizing the breakup reaction of laser-driven deuterons in a 9 Be converter. The neutron generation scaling from such a reaction is used to guide the choice and optimization of the acceleration process for bulk ions in a low density CD 2 foam. In particular, the collisionless shock acceleration mechanism is exploited with proper choice in the laser and target parameter space to accelerate these ions toward energies above the temperature of the distribution. Particle-in-cell and Monte Carlo simulations are coupled here to investigate this concept and possible adverse effects as well as the contribution from the surface ions accelerated and the optimal converter design. The simulation results indicated that our design can be a practical approach to increase both the neutron yield and angular fluence of laser-driven neutron sources, reaching >10 11 neutron/pulse (or >10 8 neutron/J) and >10 11 neutron/sr (or >10 8 neutron/sr/J) with present-day kJ-class high-power lasers. Such developments will advance fundamental neutron science, high precision radiography, and other global security applications with laser-driven sources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling of a spatially resolved ion temperature diagnostic for inertial confinement fusion

Here, the performance of modern laser-driven inertial confinement fusion (ICF) experiments is degraded by contamination of the deuterium–tritium (DT) fuel with high-Z material during compression. Simulations suggest that this mix can be described by the ion temperature distribution of the implosion, given that such contaminants deviate in temperature from the surrounding DT plasma. However, existing neutron time-of-flight (nTOF) diagnostics only measure the spatially integrated ion temperature. This paper describes the techniques and forward modeling used to develop a novel diagnostic imaging system to measure the spatially resolved ion temperature of an ICF implosion for the first time. The technique combines methods in neutron imaging and nTOF diagnostics to measure the ion temperature along one spatial dimension at yields currently achievable on the OMEGA laser. A detailed forward model of the source and imaging system was developed to guide instrument design. The model leverages neutron imaging reconstruction algorithms, radiation hydrodynamics and Monte Carlo simulations, optical ray tracing, and more. The results of the forward model agree with the data collected on OMEGA using the completed diagnostic. The analysis of the experimental data is still ongoing and will be discussed in a separate publication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delivery of H - / H + Beams to Area A

We explore the relative merits of transporting the beam from the H + ion source and from the H - ion source to Area-A for low current applications. Transporting the H - beam to Area-A using the laser neutralization approach has some risk associated with it and will require some development. Alternative method of delivering H - beam to Area-A includes replacing LDBM00 bending magnet with kicker for sharing beam between Line D and modified Line A. Transporting the H + beam to Area-A will have significant impact on the operation the IPF facility and maintaining high pulse rate to IPF will require major modifications to the transition region of the accelerator and Drift Tube Linac.

43 PARTICLE ACCELERATORS↗

Modeling noise in global Mølmer-Sørensen interactions applied to quantum approximate optimization

Many-qubit Mølmer-Sørensen (MS) interactions applied to trapped ions offer unique capabilities for quantum information processing, with applications including quantum simulation and the quantum approximate optimization algorithm (QAOA). Here, we develop a physical model to describe many-qubit MS interactions under four sources of experimental noise: vibrational mode frequency fluctuations, laser power fluctuations, thermal initial vibrational states, and state preparation and measurement errors. The model parametrizes these errors from simple experimental measurements, without free parameters. Herein, we validate the model in comparison with experiments that implement sequences of MS interactions on two 171 Yb + ions. The model shows reasonable agreement after several MS interactions as quantified by the reduced chi-squared statistic $χ^{2}_{red}$≈2. As an application we examine MaxCut QAOA experiments on three and six ions. The experimental performance is quantified by approximation ratios that are 91% and 83% of the optimal theoretical values. Our model predicts $0.93^{+0.03}_{-0.02}$ and $0.95^{+0.04}_{-0.03}$, respectively, with disagreement in the latter value attributable to secondary noise sources beyond those considered in our analysis. With realistic experimental improvements to reduce measurement error and radial trap frequency variations, the model achieves approximation ratios that are 99% of the optimal. Incorporating these improvements into future experiments is expected to reveal new aspects of noise for future modeling and experimental improvements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High power density soft x-ray GaAs photodiodes with tailored spectral response

GaAs photodiode arrays have been designed for non-destructive monitoring of x-ray beam position in soft coherent beamline front ends in synchrotron light sources. A shallow p-on-n junction was employed to reduce the device photocurrent density to optimize the operation with beam power densities up to 20 W mm -2 , mainly coming from hard x-rays. With this approach, the photocurrent is primarily defined by the excess carriers generated by low-energy x-ray photons absorbed near the detector surface. The p–n junction structures were grown by molecular beam epitaxy and processed into 64-element linear photodiode arrays. The devices were characterized first in the visible range with a high-power Ar-ion laser and then tested in the soft and hard x-ray regions up to 10 keV at two beamlines of the National Synchrotron Light Source II. The responsivity was measured to be 0.16 A W -1 at 0.7 keV and 0.05 A W -1 at 6 keV in agreement with modeling. At higher x-ray energies the measured responsivity was lower than predicted in the framework of the carrier diffusion model; a possible explanation is discussed.

36 MATERIALS SCIENCE↗

Vapor phase diamond growth technology

Ion beam deposition chambers used for carbon film generation were designed and constructed. Features of the developed equipment include: (1) carbon ion energies down to approx. 50 eV; (2) in suit surface monitoring with HEED; (3) provision for flooding the surface with ultraviolet radiation; (4) infrared laser heating of substrate; (5) residual gas monitoring; (6) provision for several source gases, including diborane for doping studies; and (7) growth from either hydrocarbon source gases or from carbon/argon arc sources. Various analytical techniques for characterization of from carbon/argon arc sources. Various analytical techniques for characterization of the ion deposited carbon films used to establish the nature of the chemical bonding and crystallographic structure of the films are discussed. These include: H2204/HN03 etch; resistance measurements; hardness tests; Fourier transform infrared spectroscopy; scanning auger microscopy; electron spectroscopy for chemical analysis; electron diffraction and energy dispersive X-ray analysis; electron energy loss spectroscopy; density measurements; secondary ion mass spectroscopy; high energy electron diffraction; and electron spin resonance. Results of the tests are summarized.

Angus, J. C.↗

A localized view on molecular dissociation via electron-ion partial covariance

Inner-shell photoelectron spectroscopy provides an element-specific probe of molecular structure, as core-electron binding energies are sensitive to the chemical environment. Short-wavelength femtosecond light sources, such as Free-Electron Lasers (FELs), even enable time-resolved site-specific investigations of molecular photochemistry. Here, we study the ultraviolet photodissociation of the prototypical chiral molecule 1-iodo-2-methylbutane, probed by extreme-ultraviolet (XUV) pulses from the Free-electron LASer in Hamburg (FLASH) through the ultrafast evolution of the iodine 4d binding energy. Methodologically, we employ electron-ion partial covariance imaging as a technique to isolate otherwise elusive features in a two-dimensional photoelectron spectrum arising from different photofragmentation pathways. The experimental and theoretical results for the time-resolved electron spectra of the 4d 3/2 and 4d 5/2 atomic and molecular levels that are disentangled by this method provide a key step towards studying structural and chemical changes from a specific spectator site.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dielectronic satellite emission from a solid-density Mg plasma: Relationship to models of ionization potential depression

Here, we report on experiments where solid-density Mg plasmas are created by heating with the focused output of the Linac Coherent Light Source x-ray free-electron laser. We study the K-shell emission from the helium- and lithium-like ions using Bragg crystal spectroscopy. Observation of the dielectronic satellites in lithium-like ions confirms that the M-shell electrons appear bound for these high charge states. An analysis of the intensity of these satellites indicates that when modeled with an atomic-kinetics code, the ionization potential depression model employed needs to produce depressions for these ions which lie between those predicted by the well known Stewart-Pyatt and Ecker-Kroll models. These results are largely consistent with recent density functional theory calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Infrared upconversion for astronomical applications

The performance of an upconversion system is examined for observation of astronomical sources in the low to middle infrared spectral range. Theoretical values for the performance parameters of an upconversion system for astronomical observations are evaluated in view of the conversion efficiencies, spectral resolution, field of view, minimum detectable source brightness and source flux. Experimental results of blackbody measurements and molecular absorption spectrum measurements using a lithium niobate upconverter with an argon-ion laser as the pump are presented. Estimates of the expected optimum sensitivity of an upconversion device which may be built with the presently available components are given.

Abbas, M. M.↗