Search NASA⌕ Search

SEARCH · Search NASA

Results for “limiting techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Single Hit Energy-resolved Laue Diffraction

In situ white light Laue diffraction has been successfully used to interrogate the structure of single crystal materials undergoing rapid (nanosecond) dynamic compression up to megabar pressures. However, information on strain state accessible via this technique is limited, reducing its applicability for a range of applications. Here, we present an extension to the existing Laue diffraction platform in which we record the photon energy of a subset of diffraction peaks. This allows for a measurement of the longitudinal and transverse strains in situ during compression. Consequently, we demonstrate measurement of volumetric compression of the unit cell, in addition to the limited aspect ratio information accessible in conventional white light Laue. We present preliminary results for silicon, where only an elastic strain is observed. VISAR measurements show the presence of a two wave structure and measurements show that material downstream of the second wave does not contribute to the observed diffraction peaks, supporting the idea that this material may be highly disordered, or has undergone large scale rotation.

47 OTHER INSTRUMENTATION↗

Applicability and Limitations of Reliability Allocation Methods

Reliability allocation process may be described as the process of assigning reliability requirements to individual components within a system to attain the specified system reliability. For large systems, the allocation process is often performed at different stages of system design. The allocation process often begins at the conceptual stage. As the system design develops, more information about components and the operating environment becomes available, different allocation methods can be considered. Reliability allocation methods are usually divided into two categories: weighting factors and optimal reliability allocation. When properly applied, these methods can produce reasonable approximations. Reliability allocation techniques have limitations and implied assumptions that need to be understood by system engineers. Applying reliability allocation techniques without understanding their limitations and assumptions can produce unrealistic results. This report addresses weighting factors, optimal reliability allocation techniques, and identifies the applicability and limitations of each reliability allocation technique.

Reliability allocation↗

R and D toward a compact high-brilliance X-ray source based on channeling radiation

X-rays have been valuable to a large number of fields including Science, Medicine, and Security. Yet, the availability of a compact high-spectral brilliance X-ray sources is limited. A technique to produce X-rays with spectral brilliance B{approx} 10{sup 12} photons.(mm-mrd){sup -2}. (0.1% BW){sup -1}.s{sup -1} is discussed. The method is based on the generation and acceleration of a low-emittance field-emitted electron bunches. The bunches are then focused on a diamond crystal thereby producing channeling radiation. In this paper, after presenting the overarching concept, we discuss the generation, acceleration and transport of the low-emittance bunches with parameters consistent with the production of high-brilliance X-rays through channeling radiation. We especially consider the example of the Advanced Superconducting Test Accelerator (ASTA) currently in construction at Fermilab where a proof-of-principle experiment is in preparation.

43 PARTICLE ACCELERATORS↗

Linear variable differential transformer (LVDT)-based elongation measurements in Advanced Test Reactor high temperature irradiation testing

New materials are being considered for fuel, cladding and structures in next generation and existing nuclear reactors. These materials can undergo significant dimensional and physical changes during high temperature irradiations. Currently, such changes are determined by repeatedly irradiating a specimen for a specified period of time in the Advanced Test Reactor (ATR) and then removing it from the reactor for evaluation. The labor and time to remove, examine and return irradiated samples for each measurement make this approach very expensive. In addition, such techniques provide limited data and may disturb the phenomena of interest. To resolve these issues, an instrumented creep testing capability is being developed for specimens irradiated under pressurized water reactor coolant conditions in the ATR at the Idaho National Laboratory (INL). This paper reports the status of INL efforts to develop this testing capability. In addition to providing an overview of in-pile creep test capabilities available at other test reactors, this paper focuses on efforts to design and evaluate a prototype test rig in an autoclave at INL’s High Temperature Test Laboratory.

99 GENERAL AND MISCELLANEOUS↗

Non-target RNA depletion strategy to improve sensitivity of next-generation sequencing for the detection of RNA viruses in poultry

PCR-based assays have become the benchmark for detecting pathogens of poultry and other livestock; however, these techniques are limited in their ability to detect multiple infecting agents, provide limited genetic information on the pathogen, and, for RNA viruses, must be reviewed frequently to assure high sensitivity and specificity. In contrast, untargeted, high-throughput sequencing can rapidly detect all infecting agents in a sample while providing genomic sequence information to allow more in-depth characterization of viruses. Although next-generation sequencing (NGS) offers many advantages, one of its primary limitations is low sensitivity to pathogens given the abundance of host and other non-target sequences in sequencing libraries. We explored methods for improving the sensitivity of NGS to detect respiratory and enteric viruses in poultry from RNA extracts of swab samples. We employed commercial and custom-designed negative enrichment strategies to selectively deplete the most abundant rRNA reads from the host and non-target bacteria; host RNA was diminished from up to 40% of total reads to as low as 3%, and the total number of reads assigned to abundant bacterial classes were reduced greatly. Our treatment resulted in up to a 700-fold increase in the number of viral reads, detection of a greater number of viral agents, and higher average genome coverage for pathogens. Depletion assays added only 2 h to the NGS library preparation workflow. Custom depletion probe design offered significant cost savings (US$7–12 per sample) compared to commercial kits (US$30–50 per sample).

Parris, D. Joshua↗

Conservation Voltage Reduction (CVR) via Two-Timescale Control in Unbalanced Power Distribution Systems

Voltage control devices are employed in power distribution systems to reduce the power consumption by operating the system closer to the lower acceptable voltage limits; this technique is called conservation voltage reduction (CVR). The different modes of operation for system’s legacy devices (with binary control) and new devices (e.g. smart inverters with continuous control) coupled with variable photovoltaic (PV) generation results in voltage fluctuations which makes it challenging to achieve CVR objective. This paper presents a two-timescale control of feeder’s voltage control devices to achieve CVR that includes (1)a centralized controller operating in a slower time-scale to coordinate voltage control devices across the feeder and (2) local controllers operating in a faster timescale to mitigate voltage fluctuations due to PV variability. The centralized controller utilizes a three-phase optimal power flow model to obtain the decision variables for both legacy devices and smart inverters. The local controllers operate smart inverters to minimize voltage fluctuations and restore nodal voltages to their reference values by adjusting the reactive power support. The proposed approach is validated using the IEEE-123 bus (medium-size) and R3-12.47-2 (large-size) feeders. It is demonstrated that the proposed approach is effective in achieving the CVR objective for unbalanced distribution systems.

optimal control, distributed generation, fluctuati↗

In situ and operando force-based atomic force microscopy for probing local functionality in energy storage materials

Electrochemical energy storage is the key enabling component of electric vehicles and solar-/wind-based energy technologies. The enhancement of energy stored requires the detailed understanding of charge storage mechanisms and local electrochemical and electromechanical phenomena over a variety of length scales from atoms to full cells. Classical electrochemical techniques, such as voltammetry, represent the macroscopic electrochemical properties, and consequently do not allow to extract important information about local electrochemical reactions, ions adsorption, intercalations, and transport. Understanding, controlling, and tuning the local electrochemical functionalities in functional energy materials require in situ/operando techniques which limit the use of structural and functional characterization techniques that provide local information. Here, force-based atomic force microscopies (AFMs) have provided novel insights into locally probing electrochemical mechanisms on tens of nanometer and even molecular length scales and provide a viable pathway to probe electrochemical processes in situ/operando. In this review, we highlight the contributions in the development and application of force-based AFM methods to elucidate the local charge storage mechanism in a variety of energy-related materials. We will focus in particular on methods or AFM modalities in a liquid electrolyte environment.

25 ENERGY STORAGE↗

Potential and limitations of microanalysis SEM techniques to characterize borides in brazed Ni-based superalloys

Brazed Ni-based superalloys containing complex phases of different Boron contents remain difficult to characterize at the micrometer scale. Indeed Boron is a light element difficult to measure precisely. The state-of-the-art microanalysis systems have been tested on a single crystal MC2 based metal brazed with BNi-2 alloy to identify boride precipitates. Effort has been made to evaluate the accuracy in Boron quantitation. Energy-dispersive and wavelength-dispersive X-ray spectroscopy attached to a Scanning Electron Microscope have first been used to determine the elemental composition of Boron-free phases, and then applied to various types of borides. Results have been compared to the ones obtained using a dedicated electron probe microanalysis, considered here as the reference technique. The most accurate method to quantify Boron using EDS is definitely by composition difference. A precision of 5 at.% could be achieved with optimized data acquisition and post-processing schemes. Attempts that aimed at directly quantifying Boron with various standards using EDS or coupled EDS/WDS gave less accurate results. Ultimately, Electron Backscatter Diffraction combined with localized EDS analysis has proved invaluable in conclusively identifying micrometer sized boride precipitates; thus further improving the characterization of brazed Ni-based superalloys. - Highlights: • We attempt to accurately identify Boron-rich phases in Ni-based superalloys. • EDS, WDS, EBSD systems are tested for accurate identification of these borides. • Results are compared with those obtained by electron probe microanalysis. • Boron was measured with EDS by composition difference with a precision of 5 at. %. • Additional EBSD in phase identification mode conclusively identifies the borides.

36 MATERIALS SCIENCE↗

Scientific applications of frequency-stabilized laser technology in space

A synoptic investigation of the uses of frequency-stabilized lasers for scientific applications in space is presented. It begins by summarizing properties of lasers, characterizing their frequency stability, and describing limitations and techniques to achieve certain levels of frequency stability. Limits to precision set by laser frequency stability for various kinds of measurements are investigated and compared with other sources of error. These other sources include photon-counting statistics, scattered laser light, fluctuations in laser power, and intensity distribution across the beam, propagation effects, mechanical and thermal noise, and radiation pressure. Methods are explored to improve the sensitivity of laser-based interferometric and range-rate measurements. Several specific types of science experiments that rely on highly precise measurements made with lasers are analyzed, and anticipated errors and overall performance are discussed. Qualitative descriptions are given of a number of other possible science applications involving frequency-stabilized lasers and related laser technology in space. These applications will warrant more careful analysis as technology develops.

Schumaker, Bonny L.↗

Non-contact Creep Resistance Measurement for Ultra-high temperature Materials

Continuing pressures for higher performance and efficiency in propulsion are driving ever more demanding needs for high-temperature materials. Some immediate applications in spaceflight include combustion chambers for advanced chemical rockets and turbomachinery for jet engines and power conversion in nuclear-electric propulsion. In the case of rockets, the combination of high stresses and high temperatures make the characterization of creep properties very important. Creep is even more important in the turbomachinery, where a long service life is an additional constraint. Some very high-temperature materials are being developed, including platinum group metals, carbides, borides, and silicides. But the measurement of creep properties at very high temperatures is itself problematic, because the testing instrument must operate at such high temperatures. Conventional techniques are limited to about 1700 C. A new, containerless technique for measuring creep deformation has been developed. This technique is based on electrostatic levitation (ESL) of a spherical sample, which is heated to the measurement temperature and rotated at a rate such that the centrifugal acceleration causes creep deformation. Creep of samples has been demonstrated at up to 2300 C in the ESL facility at NASA MSFC, while ESL itself has been applied at over 3000 C, and has no theoretical maximum temperature. The preliminary results and future directions of this NASA-funded research collaboration will be presented.

Hyers, Robert W.↗

Shot noise limited detection of OH using the technique of laser induced fluorescence

Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluorescence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the shot-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.

Bakalyar, D. M.↗

Risk Assessment of Radiation Exposure using Molecular Biodosimetry

Current cytogenetic biodosimetry methods would be difficult to adapt to spaceflight operations, because they require toxic chemicals and a substantial amount of time to perform. In addition, current biodosimetry techniques are limited to whole body doses over about 10cGy. Development of new techniques that assess radiation exposure response at the molecular level could overcome these limitations and have important implications in the advancement of biodosimetry. Recent technical advances include expression profiling at the transcript and protein level to assess multiple biomarkers of exposure, which may lead to the development of a radiation biomarker panel revealing possible fingerprints of individual radiation sensitivity. So far, many biomarkers of interest have been examined in their response to ionizing radiation, such as cytokines and members of the DNA repair pathway. New technology, such as the Luminex system can analyze many biomarkers simultaneously in one sample.

Elliott, Todd F.↗

Defect Characterization of Monocrystalline Silicon Solar Cells with Polysilicon Passivated Contact Using Electrically-Detected Magnetic Resonance (EDMR) Spectroscopy

As the c-Si based solar cell efficiencies are approaching over 26%, it is becoming critical to characterize the low concentrations of the defects – as low as 10^10-10^11 cm-3 (for e.g., iron contamination in high-lifetime Ga-doped wafers3 and n-type wafers), and further reduce them. Also, atomistic level understanding of the mechanisms of the low concentration process-induced-defects and reliability limiting defects (such as light and elevated temperature induced degradation, surface passivation degradation) is needed to design the mitigation strategies. The conventional characterization techniques are limited due to their detection limitations. Some of the techniques based on lifetime spectroscopies can still be used for low concentration characterization however, they are based on estimations and theoretical models and hence, indirect and cannot fully reveal information about the microscopic mechanism of the defects. Thus, we present the application of an ultrasensitive magnetic resonance-based technique for the direct spectroscopic detection of the defects in Si PV - electrically detected magnetic resonance (EDMR). In this work, we aim to focus on establishing a process flow for fabrication of minicells with (miniature replica of the larger-area cells) and setting up the routine for EDMR measurements on them with the EDMR instrumentation capability at NREL. For the EDMR measurements, sample size is limited by the dimensions of sample holder tube (width less than 3.2 mm, active area - 20 mm). Thus, we have designed c-Si based minicells with polysilicon (poly-Si) passivated contacts same as the larger-area cells that we fabricate in our group at NREL. We also modified our minicell process flow for fabricating the textured minicells for preserving the texture during processing and taking care of the laser-ablation edge damage which can significantly affect the performance of such small devices. We have achieved comparable performance on these newly fabricated minicells as that of our 4 cm2 devices with same structure (comparable VOC, JSC, FF). We also conducted EDMR measurements on the minicells and observed a distinct EDMR signal at g-value ~2.005 at temperatures 30K and above, as shown in Fig. 2. We associate this signal to the presence of silicon dangling bonds based on the g-value. We also observed an EDMR signal at g-value ~1.998 at temperature ~5K. The origin of this signal is still being investigated. Thus, we show the proof of concept of minicells and EDMR measurements with which we now aim to study some of the unknown defects in silicon solar cell devices.

EDMR↗

Shot noise limited detection of OH using the technique of laser-induced fluorescence

Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluoresence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the short-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.

Bakalyar, D. M.↗