Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Dual-Photoelastic-Modulator-Based Polarimetric Imaging Concept for Aerosol Remote Sensing

A dual-photoelastic-modulator- (PEM-) based spectropolarimetric camera concept is presented as an approach for global aerosol monitoring from space. The most challenging performance objective is to measure degree of linear polarization (DOLP) with an uncertainty of less than 0.5% in multiple spectral bands, at moderately high spatial resolution, over a wide field of view, and for the duration of a multiyear mission. To achieve this, the tandem PEMs are operated as an electro-optic circular retardance modulator within a high-performance reflective imaging system. Operating the PEMs at slightly different resonant frequencies generates a beat signal that modulates the polarized component of the incident light at a much lower heterodyne frequency. The Stokes parameter ratio q = Q/I is obtained from measurements acquired from each pixel during a single frame, providing insensitivity to pixel responsivity drift and minimizing polarization artifacts that conventionally arise when this quantity is derived from differences in the signals from separate detectors. Similarly, u = U/I is obtained from a different pixel; q and u are then combined to form the DOLP. A detailed accuracy and tolerance analysis for this polarimeter is presented.

spectropolarimetric imaging↗

A comparison of two photogrammetric algorithms for the measurement of model deformation in the National Transonic Facility

A comparison was made of two photogrammetric measurement techniques which can be used for the determination of the spatial loctions of targets. One technique is known as the Direct Linear Transformation (DLT), and the other is referred to as the Bundle method. Each technique utilizes triangulation of image data from two or more cameras, but they differ in their method of determining camera parameters. While the study was performed with simulated data, the geometries, image data accuracies and other parameters were set to simulate conditions for a two-camera, photogrammetric system which will be used at the National Transonic Facility at the NASA's Langley Research Center. For the conditions studied the Bundle technique was found to have smaller errors. Both methods were sensitive to the spatial distribution of control-point targets, but this effected the accuracy of the Bundle algorithm less than that of the DLT algorithm.

Monteith, J. H.↗

Use of Photoelastic Modulators for High-accuracy Spectropolarimetric Imaging of Aerosols

Passive multiangular, multispectral, and polarimetric sensing approaches each have unique strengths for the measurement of tropospheric aerosol column abundances and microphysical properties. Current spaceborne multispectral and multiangular aerosols sensors operate at approximately 1 km resolution. Under NASA's Instrument Incubator Program, we are developing an electro-optic imaging approach that will enable adding high-accuracy polarimetry to such observations. To achieve a degree of linear polarization (DOLP) uncertainty of 0.5%, our approach temporally modulates the linear-polarization component of incoming light at a rapid rate, enabling each detector within a focal-plane array, combined with polarization analyzers, to measure the relative proportions of the linear Stokes components Q or U to the total intensity. Our system uses tandem photoelastic modulators (PEMs) within a high-reflectance, low diattenuation camera design. The two PEMs vibrate at slightly different resonant frequencies, leading to modulation of the polarized light at a heterodyne frequency of ~25 Hz. High-speed (1 kHz) readout of the detector arrays samples the output waveforms from which Q/I and U/I are derived. We report on experimental and theoretical analyses of PEM and optical system performance, along with plans for developing ruggedized PEMs capable of withstanding launch and on-orbit stresses.

photoelastics↗

Using Computational Flow Imaging to Optimize Filtered Rayleigh Scattering Measurements of an Isolator Shock Train

Filtered Rayleigh scattering (FRS) is a laser diagnostic where the intensity of elastically scattered light is measured after it passes through a molecular absorption filter. The filter removes background interference that overwhelms the relatively weak scattering from the gas molecules. However, with a filter, the measured light intensity depends on many of the scattering gas properties, including pressure, density, temperature, and velocity. In this work, CFD simulations of an isolator shock train flow field are input into a physics-based model to predict the values of FRS intensity measurements in a proposed experiment. The goal is to evaluate if a simplistic FRS setup (that utilizes one camera, laser, and absorption filter) can be used to accurately quantify number density despite the fact that the scattered light intensity also depends on other gas properties. It is found that the experimental setup can be optimized such that a linear relationship describes the number density with an average prediction error of 2%. The vast majority of the flow exhibits prediction errors of less than 3%, but small regions of the flow reach up to 11% error. A sensitivity analysis shows that the prediction error increases with the central wavelength of the incident laser light and decreases with the angle between the camera and laser propagation directions. The optimal experimental parameters are chosen based on a compromise between the prediction error, spatial resolution, and the amount of unfiltered light. In the future, the proposed FRS setup will be implemented to acquire new and valuable information on an isolator shock train, a flow field that has been traditionally studied using wall static pressure measurements and path-integrated visualization techniques, such as schlieren and shadowgraphy.

Hunt, Robin L.↗

X-ray topographic observations of magnetic domains in Czochralski-grown nickel single crystals in anomalous transmission geometry

The anomalous transmission effect has been observed in nickel single crystals grown by the Czochralski technique. Sample crystals prepared for X-ray topography are 1.5 to 2.5 cm in diameter and thicker than 0.4 mm; the product of the ordinary linear absorption coefficient and thickness ranges from 17 to 45 for Cu K-alpha radiation. Topographs taken with an asymmetric-crystal-topographic (ACT) camera have revealed extremely straight line images and rectangular arrangements of short line-segment images, along with the images of crystal imperfections. The line images change their arrangement upon application of magnetic fields. These images are attributed to magnetic domains in the interior of crystals. The formation of domain walls near the crystal surface is also observed and distinguished clearly from magnetic domains in the bulk with the use of the ACT camera.

Kuriyama, M.↗

Support Routines for In Situ Image Processing

This software consists of a set of application programs that support ground-based image processing for in situ missions. These programs represent a collection of utility routines that perform miscellaneous functions in the context of the ground data system. Each one fulfills some specific need as determined via operational experience. The most unique aspect to these programs is that they are integrated into the large, in situ image processing system via the PIG (Planetary Image Geometry) library. They work directly with space in situ data, understanding the appropriate image meta-data fields and updating them properly. The programs themselves are completely multimission; all mission dependencies are handled by PIG. This suite of programs consists of: (1)marscahv: Generates a linearized, epi-polar aligned image given a stereo pair of images. These images are optimized for 1-D stereo correlations, (2) marscheckcm: Compares the camera model in an image label with one derived via kinematics modeling on the ground, (3) marschkovl: Checks the overlaps between a list of images in order to determine which might be stereo pairs. This is useful for non-traditional stereo images like long-baseline or those from an articulating arm camera, (4) marscoordtrans: Translates mosaic coordinates from one form into another, (5) marsdispcompare: Checks a Left Right stereo disparity image against a Right Left disparity image to ensure they are consistent with each other, (6) marsdispwarp: Takes one image of a stereo pair and warps it through a disparity map to create a synthetic opposite- eye image. For example, a right eye image could be transformed to look like it was taken from the left eye via this program, (7) marsfidfinder: Finds fiducial markers in an image by projecting their approximate location and then using correlation to locate the markers to subpixel accuracy. These fiducial markets are small targets attached to the spacecraft surface. This helps verify, or improve, the pointing of in situ cameras, (8) marsinvrange: Inverse of marsrange . given a range file, re-computes an XYZ file that closely matches the original. . marsproj: Projects an XYZ coordinate through the camera model, and reports the line/sample coordinates of the point in the image, (9) marsprojfid: Given the output of marsfidfinder, projects the XYZ locations and compares them to the found locations, creating a report showing the fiducial errors in each image. marsrad: Radiometrically corrects an image, (10) marsrelabel: Updates coordinate system or camera model labels in an image, (11) marstiexyz: Given a stereo pair, allows the user to interactively pick a point in each image and reports the XYZ value corresponding to that pair of locations. marsunmosaic: Extracts a single frame from a mosaic, which will be created such that it could have been an input to the original mosaic. Useful for creating simulated input frames using different camera models than the original mosaic used, and (12) merinverter: Uses an inverse lookup table to convert 8-bit telemetered data to its 12-bit original form. Can be used in other missions despite the name.

Deen, Robert G.↗

A Numerical and Experimental Study of Coflow Laminar Diffusion Flames: Effects of Gravity and Inlet Velocity

In this work, the influence of gravity, fuel dilution, and inlet velocity on the structure, stabilization, and sooting behavior of laminar coflow methane-air diffusion flames was investigated both computationally and experimentally. A series of flames measured in the Structure and Liftoff in Combustion Experiment (SLICE) was assessed numerically under microgravity and normal gravity conditions with the fuel stream CH4 mole fraction ranging from 0.4 to 1.0. Computationally, the MC-Smooth vorticity-velocity formulation of the governing equations was employed to describe the reactive gaseous mixture; the soot evolution process was considered as a classical aerosol dynamics problem and was represented by the sectional aerosol equations. Since each flame is axisymmetric, a two-dimensional computational domain was employed, where the grid on the axisymmetric domain was a nonuniform tensor product mesh. The governing equations and boundary conditions were discretized on the mesh by a nine-point finite difference stencil, with the convective terms approximated by a monotonic upwind scheme and all other derivatives approximated by centered differences. The resulting set of fully coupled, strongly nonlinear equations was solved simultaneously using a damped, modified Newton's method and a nested Bi-CGSTAB linear algebra solver. Experimentally, the flame shape, size, lift-off height, and soot temperature were determined by flame emission images recorded by a digital camera, and the soot volume fraction was quantified through an absolute light calibration using a thermocouple. For a broad spectrum of flames in microgravity and normal gravity, the computed and measured flame quantities (e.g., temperature profile, flame shape, lift-off height, and soot volume fraction) were first compared to assess the accuracy of the numerical model. After its validity was established, the influence of gravity, fuel dilution, and inlet velocity on the structure, stabilization, and sooting tendency of laminar coflow methane-air diffusion flames was explored further by examining quantities derived from the computational results.

microgravity↗

Wavenumber-frequency Spectra of Pressure Fluctuations on a Generic Space Vehicle Measured via Unsteady Pressure-Sensitive Paint

Time histories of pressure fluctuations on a generic, hammerhead space vehicle model were measured using unsteady Pressure-Sensitive Paint (uPSP). The test was conducted in the 11-foot transonic wind tunnel of NASA Ames Research Center over a Mach number range of 0.6 M 1.2, and angles of attack of -4 4. The model was coated with a porous binder and PtTFPP-based porous polymer paint. An elaborate system of four high-speed cameras, and forty LED lamps was used for image acquisition. Various steps for image registration, reduction of shot noise, photogrammetry procedure to map images from the four cameras on a grid for the model, and finally a calibration procedure to convert the measured fluctuations in light intensity to fluctuating pressure, are discussed in the paper. The calibration process using a set of unsteady pressure sensors mounted on the model, was found to overcome some of the inherent problems of the fast response paint, such as rapid photo-degradation, non-linearity in pressure response, and significant temperature sensitivity. Comparison of spectra of pressure fluctuations between UPSP and pressure sensors demonstrated the ability of the paint to faithfully follow fluctuations up to 10 kHz, the maximum attempted. It was also found that the camera bit-depth and the illumination level limited the lowest measurable levels of pressure fluctuations to around 140dB. The large data set exposed various critical transonic flow physics not seen before, such as a coupling of the shock motion on the Payload Fairing (PF) with the separated flow region on the upper stage of the launch vehicle, and upstream convection of pressure fluctuation on PF at certain Mach numbers. The data also confirmed the expectation of a general lowering of the coefficient of pressure fluctuation with Mach number. The availability of the data set on a dense, regularly-spaced, surface grid allowed for the calculation of wavenumber-frequency (k-) spectra via straightforward applications of Fourier transform. The k- spectra were compared for the separated flow regions on the Second Stage, and the shock-boundary layer interactions on PF. The former showed self-similarity with Mach number while the latter was distinctly different, and confirmed the upstream propagation of pressure fluctuations. The k- spectra were dominated by the convected fluctuations; the acoustic domain was not discernable. These data, valuable for the vibro-acoustics analysis of aerospace vehicles, are believed to be the first obtained for the transonic flight regime, and pave the path for application on production models of aerospace vehicles.

buffet↗

International Halley Watch: Discipline specialists for photometry and polarimetry

The last of the 75 sets of standard filters were distributed, including re-allocation of several sets from north to south at the beginning of 1986. Observations of the photometric standard stars from several observatories were collected and synthesized into a standard system of magnitudes. Transformation equations were derived to yield absolute fluxes in various cometary emission bands and in the continuum. These transformations turned out to vary with the comet's radial velocity for some filters and with the filter's temperature for some filters, and from one set of filters to another, all effects were quantitatively assessed. Non-linearities in the extinction, observed through the OH filter, were modelled and techniques for linearizing the extinction were developed. Although not among the official goals of the IHW, NASA Headquarters chose to work through the IHW to develop two CCD camera systems. Two iterations of an archive format were performed and a third is in the works.

Ahearn, M. F.↗

Polarization of the solar corona.

A method of obtaining polarized photographs of the solar corona during total eclipse is described. The required equipment is a reflex viewing type camera with a lens of adequate focal length to give an image of the corona a few millimeters in diameter at the focal plane. A sheet of linear polarizing filter material is placed directly in front of the lens. The filter is mounted in such a way so as to permit a set of four exposures of equal length to be taken after totality begins. Since the light of the corona is highly polarized, the resultant set of photographs will show marked differences in the shape of the corona.

Feibelman, W. A.↗

Wind dynamic range video camera

A television camera apparatus is disclosed in which bright objects are attenuated to fit within the dynamic range of the system, while dim objects are not. The apparatus receives linearly polarized light from an object scene, the light being passed by a beam splitter and focused on the output plane of a liquid crystal light valve. The light valve is oriented such that, with no excitation from the cathode ray tube, all light is rotated 90 deg and focused on the input plane of the video sensor. The light is then converted to an electrical signal, which is amplified and used to excite the CRT. The resulting image is collected and focused by a lens onto the light valve which rotates the polarization vector of the light to an extent proportional to the light intensity from the CRT. The overall effect is to selectively attenuate the image pattern focused on the sensor.

Craig, G. D.↗

Simultaneous Luminescence Pressure and Temperature Mapping

A simultaneous luminescence pressure and temperature mapping system is developed including improved dye application techniques for surface temperature and pressure measurements from 5 torr to 1000 torr with possible upgrade to from 0.5 torr to several atmospheres with improved camera resolution. Adsorbed perylene dye on slip-cast silica is pressure (oxygen) sensitive and reusable to relatively high temperatures (-150 C). Adsorbed luminescence has an approximately linear color shift with temperature, which can be used for independent temperature mapping and brightness pressure calibration with temperature.

Buck, Gregory M.↗

Orion Optical Navigation Progress Toward Exploration Mission 1

Optical navigation of human spacecraft was proposed on Gemini and implemented successfully on Apollo as a means of autonomously operating the vehicle in the event of lost communication with controllers on Earth. The Orion emergency return system utilizing optical navigation has matured in design over the last several years, and is currently undergoing the final implementation and test phase in preparation for Exploration Mission 1 (EM-1) in 2019. The software development is past its Critical Design Review, and is progressing through test and certification for human rating. The filter architecture uses a square-root-free UDU covariance factorization. Linear Covariance Analysis (LinCov) was used to analyze the measurement models and the measurement error models on a representative EM-1 trajectory. The Orion EM-1 flight camera was calibrated at the Johnson Space Center (JSC) electro-optics lab. To permanently stake the focal length of the camera a 500 mm focal length refractive collimator was used. Two Engineering Design Unit (EDU) cameras and an EDU star tracker were used for a live-sky test in Denver. In-space imagery with high-fidelity truth metadata is rare so these live-sky tests provide one of the closest real-world analogs to operational use. A hardware-in-the-loop test rig was developed in the Johnson Space Center Electro-Optics Lab to exercise the OpNav system prior to integrated testing on the Orion vehicle. The software is verified with synthetic images. Several hundred off-nominal images are also used to analyze robustness and fault detection in the software. These include effects such as stray light, excess radiation damage, and specular reflections, and are used to help verify the tuning parameters chosen for the algorithms such as earth atmosphere bias, minimum pixel intensity, and star detection thresholds.

Holt, Greg N.↗

Coded-aperture imaging in nuclear medicine

Coded-aperture imaging is a technique for imaging sources that emit high-energy radiation. This type of imaging involves shadow casting and not reflection or refraction. High-energy sources exist in x ray and gamma-ray astronomy, nuclear reactor fuel-rod imaging, and nuclear medicine. Of these three areas nuclear medicine is perhaps the most challenging because of the limited amount of radiation available and because a three-dimensional source distribution is to be determined. In nuclear medicine a radioactive pharmaceutical is administered to a patient. The pharmaceutical is designed to be taken up by a particular organ of interest, and its distribution provides clinical information about the function of the organ, or the presence of lesions within the organ. This distribution is determined from spatial measurements of the radiation emitted by the radiopharmaceutical. The principles of imaging radiopharmaceutical distributions with coded apertures are reviewed. Included is a discussion of linear shift-variant projection operators and the associated inverse problem. A system developed at the University of Arizona in Tucson consisting of small modular gamma-ray cameras fitted with coded apertures is described.

Smith, Warren E.↗

Simultaneous Luminescence Pressure and Temperature Mapping System

A simultaneous luminescence pressure and temperature mapping system is developed including improved dye application techniques for surface temperature and pressure measurements from 5 torr to 1000 torr with possible upgrade to from 0.5 torr to several atmospheres with improved camera resolution. Adsorbed perylene dye on slip-cast silica is pressure (oxygen) sensitive and reusable to relatively high temperatures (approximately 150 C). Adsorbed luminescence has an approximately linear color shift with temperature, which can be used for independent temperature mapping and brightness pressure calibration with temperature.

Buck, Gregory M.↗

A laboratory verification sensor

The use of a variant of the Hartmann test is described to sense the coalignment of the 36 primary mirror segments of the Keck 10-meter Telescope. The Shack-Hartmann alignment camera is a surface-tilt-error-sensing device, operable with high sensitivity over a wide range of tilt errors. An interferometer, on the other hand, is a surface-height-error-sensing device. In general, if the surface height error exceeds a few wavelengths of the incident illumination, an interferogram is difficult to interpret and loses utility. The Shack-Hartmann aligment camera is, therefore, likely to be attractive as a development tool for segmented mirror telescopes, particularly at early stages of development in which the surface quality of developmental segments may be too poor to justify interferometric testing. The constraints are examined which would define the first-order properties of a Shack-Hartmann alignment camera and the precision and range of measurement one could expect to achieve with it are investigated. Fundamental constraints do arise, however, from consideration of geometrical imaging, diffraction, and the density of sampling of images at the detector array. Geometrical imagining determines the linear size of the image, and depends on the primary mirror diameter and the f-number of a lenslet. Diffraction is another constraint; it depends on the lenslet aperture. Finally, the sampling density at the detector array is important since the number of pixels in the image determines how accurately the centroid of the image can be measured. When these factors are considered under realistic assumptions it is apparent that the first order design of a Shack-Hartmann alignment camera is completely determined by the first-order constraints considered, and that in the case of a 20-meter telescope with seeing-limited imaging, such a camera, used with a suitable detector array, will achieve useful precision.

Vaughan, Arthur H.↗

Video System Highlights Hydrogen Fires

Video system combines images from visible spectrum and from three bands in infrared spectrum to produce color-coded display in which hydrogen fires distinguished from other sources of heat. Includes linear array of 64 discrete lead selenide mid-infrared detectors operating at room temperature. Images overlaid on black and white image of same scene from standard commercial video camera. In final image, hydrogen fires appear red; carbon-based fires, blue; and other hot objects, mainly green and combinations of green and red. Where no thermal source present, image remains in black and white. System enables high degree of discrimination between hydrogen flames and other thermal emitters.

Youngquist, Robert C.↗

High Spatial Resolution Investigations of Microchannel Plate Imaging Properties for UV Detectors

Microchannel plate (MCP) photon counting detectors are currently being used with great success on many of the recent NASA/ESA ultraviolet (UV) astrophysics missions that make observations in the 1OO A - 1600 A range. These include HUT, the Wide Field Camera on ROSAT, EUVE, ALEXIS, ORFEUS, and SOHO. These devices have also been chosen to fly on future UV astrophysics missions such as FUSE, FUVITA, IMAGE, and both the HST STIS and Advanced Camera instruments. During the period of this award we have fabricated a dual-chamber vacuum test facility to carry out laboratory testing of detector resolution, image stability and linearity, and flat field performance to enable us to characterize the performance of MCPs and their associated read-out architectures. We have also fabricated and tested a laboratory 'test-bed' delay line detector, which can accommodate MCP's with a wide range of formats and run at high data rates, to continue our studies of MCP image fixed pattern noise, and particularly for new small pore MCP's which have recently come onto the market. These tests were mainly focussed on the assessment of cross delay-line (XDL) and double delay line (DDL) anode read-out schemes, with particular attention being focussed on flat-field and spatial resolution performance.

Siegmund, Oswald↗