Search NASA⌕ Search

SEARCH · Search NASA

Results for “load following”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

High energy efficiency and high power density proton exchange membrane fuel cells: Electrode kinetics and mass transport

The development of proton exchange membrane (PEM) fuel cell power plants with high energy efficiencies and high power densities is gaining momentum because of the vital need of such high levels of performance for extraterrestrial (space, underwater) and terrestrial (power source for electric vehicles) applications. Since 1987, considerable progress has been made in achieving energy efficiencies of about 60 percent at a current density of 200 mA/sq cm and high power densities (greater than 1 W/sq cm) in PEM fuel cells with high (4 mg/sq cm) or low (0.4 mg/sq cm) platinum loadings in electrodes. The following areas are discussed: (1) methods to obtain these high levels of performance with low Pt loading electrodes - by proton conductor impregnation into electrodes, localization of Pt near front surface; (2) a novel microelectrode technique which yields electrode kinetic parameters for oxygen reduction and mass transport parameters; (3) demonstration of lack of water transport from anode to cathode; (4) modeling analysis of PEM fuel cell for comparison with experimental results and predicting further improvements in performance; and (5) recommendations of needed research and development for achieving the above goals.

Supramaniam Srinivasan↗

Vibration and local instability of thermally stressed plates

The vibration and buckling of a double wedge square cantilever plate has been investigated. It is shown that the free vibration modes, which occur at Delta T ref = 0, transition into the buckled modes which occur at Delta T ref = Delta T ref-cr for the respective mode. Delta T ref-cr for a particular mode is defined as the magnitude of thermal load at which the frequency of the particular mode vanishes. The analysis yields the same number of buckling eigenvalues and buckling modes as there are vibration eigenvalues and vibration modes. Gradual application of the load in the analysis permits the change in each vibration frequency of interest and its associated mode to be followed up to the load at which the frequency of the mode becomes zero. This constitutes the limit of linear theory. As the load is increased, the thin edges of the plate begin to deform during vibration. This local deformation, which begins in the vibration mode, is shown to transition into the phenomena of local edge buckling at Delta T ref-cr for the mode.

Bailey, C. D.↗

Structural load control during construction

The topics are presented in viewgraph form and include the following: examples of high transient loadings on large space structures; energy absorbing/load limiting strut research objectives; scope of research on energy absorbing struts to date; energy characteristics of cantilevered trusses with a tip load; ten bay long resilient truss example; stored energy characteristics of one meter deep truss; energy absorbing potential for 10-bay 5-meter deep truss; schematic of energy absorbing strut; linear load and motion control actuator; rigid body response of a solar array to the shuttle thruster pressure impingement; solar array piecewise linear response; solar array characteristics; solar array tip deflection and required actuator stroke; solar array response from finite element analysis; 12 bay energy absorbing test bed dynamics; and new AERO-Lab with 12-bay test beam.

Mikulas, Martin↗

Overview of Structural Response: Probabilistic Structural Analysis

Advanced analysis methods are required to predict accurately the structural response (static, transient, cyclic, etc.) and accompanying local stresses in space propulsion system components operating in a fatigue environment consisting of complex thermal and mechanical load spectra. The probabilistic approach to structural response consists of the following program elements: (1) composite load spectra, (2) probabilistic structural analysis methods development, (3) probabilitic finite element theory, (4) probabilistic structural analysis application, (5) structural tailoring of turbopump blades, (6) unified theory of dynamic creep buckling/ratcheting, (7) creep buckling/ratcheting analyzer, and (8) nonlinear COBSTRAN development. Research activities on all of these program elements (except the creep buckling/ratcheting analyzer) are under way.

Chamis, C. C.↗

Prestressing Shock Resistant Mechanical Components and Mechanisms Made from Hard, Superelastic Materials

A method and an apparatus confer full superelastic properties to the active surface of a mechanical component constructed of a superelastic material prior to service. A compressive load is applied to the active surface of the mechanical component followed by removing the compressive load from the active surface whereby substantially all load strain is recoverable after applying and removing of subsequent compressive loads.

DellaCorte, Christopher↗

Loads and aeroelasticity division research and technology accomplishments for FY 1982 and plans for FY 1983

Accomplishments of the past year and plans for the coming year are highlighted as they relate to five year plans and the objectives of the following technical areas: aerothermal loads; multidisciplinary analysis and optimization; unsteady aerodynamics; and configuration aeroelasticity. Areas of interest include thermal protection system concepts, active control, nonlinear aeroelastic analysis, aircraft aeroelasticity, and rotorcraft aeroelasticity and vibrations.

Gardner, J. E.↗

Graded Compression Stockings Prevent Post-spaceflight Orthostatic Hypotension

Post-spaceflight orthostatic intolerance is characterized by hypotension and presyncope in 20-30% of returning astronauts. Previous data from our laboratory suggests that this is largely a result of decreased venous return. Currently, NASA astronauts wear an anti-gravity suit (AGS) which consists of inflatable air bladders over the calves, thighs and abdomen, which are typically pressurized from 0.5 to 1.5 PSI (~27 to 78 mmHg). ISS crew members sometimes wear Russian Kentavr suits which consist of laced compression shorts and gaiters, providing ~30 mmHg nominally. While these garments are effective during reentry, there are a number of drawbacks that make them impractical for postflight use. We studied the ability of commercially available, custom fit, graded compression stockings (Jobst, 55 mmHg at ankle to 6 mmHg at top of thigh, 25 mmHg mean compression) to prevent postflight orthostatic intolerance, hypothesizing that these garments would prevent orthostatic intolerance following short duration space flight. Crew members from a single Space Shuttle flight were tilted to 80 degrees for 10 min while wearing the stockings (n=5 males) upon arrival at the clinic (~2 hrs after landing). Hemodynamic data were compared to data from all crewmembers tilted (without countermeasures) since return to flight (n=9). Two-way, repeated measures ANOVA, using the entire tilt time curve (0-10 min) show that systolic blood pressure (SBP, group effect p=0.008), stroke volume (SV, group effect p=0.003), and cardiac output (CO, group effect p=0.004) were higher in crewmembers who wore the Jobst stockings. A one-way ANOVA comparing the last minute standing also showed that SV (p=0.001) and CO (p less than 0.001) were higher and SBP tended to be higher (p=0.06) in Jobst subjects compared to controls. Control subjects had a higher rate of presyncope than Jobst subjects (3/9 vs 0/5) during the tilt on landing day. Orthostatic hypotension continues to present following spaceflight, despite fluid loading and other countermeasures. This preliminary study shows that commercially available compression stockings may ameliorate this problem. These stockings are readily available, inexpensive, and can be worn for days following landing. We have observed similar protection against orthostatic intolerance in ground-based studies of hypovolemic test subjects. Further refinements to the design and compression of the stockings are in progress.

Platts, S. H.↗

Analysis of unswept and swept wing chordwise pressure data from an oscillating NACA 0012 airfoil experiment. Volume 2: Data report

The analysis of the chordwise load distribution and its sensitivity to the various system parameters represents the next phase of the overall study and is the subject of the present two volume report. The present volume is a compilation of all of the time history response data obtained during the test program previously described. The data have been tabulated in the form of Fourier coefficients for reasons of compactness and for ease by the user to reproduce the unsteady component of the individual pressures and the complete (unsteady plus steady state components) integrated load results. This data volume contains the individual pressure response time histories along the chord followed by the corresponding integrated load results. A further description of these data tables can be found in the text that follows.

St.hilaire, A. O.↗

On the Response of a Nonlinear Structure to High Kurtosis Non-Gaussian Random Loadings

This paper is a follow-on to recent work by the authors in which the response and high-cycle fatigue of a nonlinear structure subject to non-Gaussian loadings was found to vary markedly depending on the nature of the loading. There it was found that a non-Gaussian loading having a steady rate of short-duration, high-excursion peaks produced essentially the same response as would have been incurred by a Gaussian loading. In contrast, a non-Gaussian loading having the same kurtosis, but with bursts of high-excursion peaks was found to elicit a much greater response. This work is meant to answer the question of when consideration of a loading probability distribution other than Gaussian is important. The approach entailed nonlinear numerical simulation of a beam structure under Gaussian and non-Gaussian random excitations. Whether the structure responded in a Gaussian or non-Gaussian manner was determined by adherence to, or violations of, the Central Limit Theorem. Over a practical range of damping, it was found that the linear response to a non-Gaussian loading was Gaussian when the period of the system impulse response is much greater than the rate of peaks in the loading. Lower damping reduced the kurtosis, but only when the linear response was non-Gaussian. In the nonlinear regime, the response was found to be non-Gaussian for all loadings. The effect of a spring-hardening type of nonlinearity was found to limit extreme values and thereby lower the kurtosis relative to the linear response regime. In this case, lower damping gave rise to greater nonlinearity, resulting in lower kurtosis than a higher level of damping.

Rizzi, Stephen A.↗

Calculation of design load for the MOD-5A 7.3 mW wind turbine system

Design loads are presented for the General Electric MOD-SA wind turbine. The MOD-SA system consists of a 400 ft. diameter, upwind, two-bladed, teetered rotor connected to a 7.3 mW variable-speed generator. Fatigue loads are specified in the form of histograms for the 30 year life of the machine, while limit (or maximum) loads have been derived from transient dynamic analysis at critical operating conditions. Loads prediction was accomplished using state of the art aeroelastic analyses developed at General Electric. Features of the primary predictive tool - the Transient Rotor Analysis Code (TRAC) are described in the paper. Key to the load predictions are the following wind models: (1) yearly mean wind distribution; (2) mean wind variations during operation; (3) number of start/shutdown cycles; (4) spatially large gusts; and (5) spatially small gusts (local turbulence). The methods used to develop statistical distributions from load calculations represent an extension of procedures used in past wind programs and are believed to be a significant contribution to Wind Turbine Generator analysis. Test/theory correlations are presented to demonstrate code load predictive capability and to support the wind models used in the analysis. In addition MOD-5A loads are compared with those of existing machines. The MOD-5A design was performed by the General Electric Company, Advanced Energy Program Department, under Contract DEN3-153 with NASA Lewis Research Center and sponsored by the Department of Energy.

Mirandy, L.↗

A Numerical Solution Routine for Investigating Oxidation-Induced Strength Degradation Mechanisms in SiC/SiC Composites

The stress rupture strength of silicon carbide fiber-reinforced silicon carbide (SiCSiC) composites with a boron nitride (BN) fiber coating decreases with time within the intermediate temperature range of 700-950 C. Various theories have been proposed to explain the cause of the time dependent stress rupture strength. Some previous authors have suggested that the observed composite strength behavior is due to the inherent time dependent strength of the fibers, which is caused by the slow growth of flaws within the fibers. Flaw growth is supposedly enabled by oxidation of free carbon at the grain boundaries. The objective of this paper is to investigate the relative significance of the various theories for the time-dependent strength of SiCSiC composites. This is achieved through the development of a numerically-based progressive failure analysis routine and through the application of the routine to simulate the composite stress rupture tests. The progressive failure routine is a time marching routine with an iterative loop between a probability of fiber survival equation and a force equilibrium equation within each time step. Failure of the composite is assumed to initiate near a matrix crack and the progression of fiber failures occurs by global load sharing. The probability of survival equation is derived from consideration of the strength of ceramic fibers with randomly occurring and slow growing flaws as well as the mechanical interaction between the fibers and matrix near a matrix crack. The force equilibrium equation follows from the global load sharing presumption. The results of progressive failure analyses of the composite tests suggest that the relationship between time and stress-rupture strength is attributed almost entirely to the slow flaw growth within the fibers. Although other mechanisms may be present, they appear to have only a minor influence on the observed time dependent behavior.

degradation↗

Time-Dependent Stress Rupture Strength Degradation of Hi-Nicalon Fiber-Reinforced Silicon Carbide Composites at Intermediate Temperatures

The stress rupture strength of silicon carbide fiber-reinforced silicon carbide composites with a boron nitride fiber coating decreases with time within the intermediate temperature range of 700 to 950 degree Celsius. Various theories have been proposed to explain the cause of the time-dependent stress rupture strength. The objective of this paper is to investigate the relative significance of the various theories for the time-dependent strength of silicon carbide fiber-reinforced silicon carbide composites. This is achieved through the development of a numerically based progressive failure analysis routine and through the application of the routine to simulate the composite stress rupture tests. The progressive failure routine is a time-marching routine with an iterative loop between a probability of fiber survival equation and a force equilibrium equation within each time step. Failure of the composite is assumed to initiate near a matrix crack and the progression of fiber failures occurs by global load sharing. The probability of survival equation is derived from consideration of the strength of ceramic fibers with randomly occurring and slow growing flaws as well as the mechanical interaction between the fibers and matrix near a matrix crack. The force equilibrium equation follows from the global load sharing presumption. The results of progressive failure analyses of the composite tests suggest that the relationship between time and stress-rupture strength is attributed almost entirely to the slow flaw growth within the fibers. Although other mechanisms may be present, they appear to have only a minor influence on the observed time-dependent behavior.

Progressive Failure Analysis↗

Composite Progressive Delamination Analysis of Thin Ply Buckling

The NASA Advanced Composites Project is a multi-year consortium of government, industry and academia to develop and validate technology that will reduce development and certification of advanced composite materials for aircraft structures. One of its tasks is to simulate and predict composite damage progression accurately through high fidelity finite element models. It included a subtask to verify an approach based on the Virtual Crack Closure Technology (VCCT) as well as Floating Node Method (FNM). This paper discusses predicted damage onset and growth in a thin-ply buckling problem. Sensitivity of the simulations to various initial crack length is studied. The compressive load-displacement curves are plotted and the crack growth critical load is predicted. Overall, the crack progression follows simulation benchmarks well. However, the critical-load overshoot phenomenon is observed in both VCCT and FNM, suggesting further investigation may be worth pursuing.

damage progression↗

A kinematically driven anisotropic viscoelastic constitutive model applied to tires

Aircraft tires are composite structures manufactured with viscoelastic materials such as carbon black filled rubber and nylon cords. When loaded they experience large deflections and moderately large strains. Detailed structural models of tires require the use of either nonlinear shell or nonlinear three dimensional solid finite elements. Computational predictions of the dynamic response of tires must consider the composite viscoelastic material behavior in a realistic fashion. We describe a modification to a nonlinear anisotropic shell finite element so it can be used to model viscoelastic stresses during general deformations. The model is developed by introducing internal variables of the type used to model elastic strain energy. The internal variables are strains, curvatures, and transverse shear angles which are in a one-to-one correspondence with the generalized coordinates used to model the elastic strain energy for nonlinear response. A difference-relaxation equation is used to relate changes in the observable strain field to changes in the internal strain field. The internal stress state is introduced into the equilibrium equations by converting it to nodal loads associated with the element's displacement degrees of freedom. In this form the tangent matrix in the Newton-Raphson solution algorithm is not modified from its form for the nonlinear statics problem. Only the gradient vector is modified and the modification is not computationally costly. The existing finite element model for the Space Shuttle nose gear tire is used to provide examples of the algorithm. In the first example, the tire's rim is displaced at a constant rate up to a fixed value. In the second example, the tire's rim is enforced to follow a saw tooth load and unload curve to generate hysteresis loops.

Johnson, Arthur R.↗

Waters Loads on the XJL-1 Hull as Obtained in Langley Impact Basin, TED No. NACA 2413.3

An investigation was conducted in the Langley impact basin of the water loads on a half scale model of the XJL-1 hull whose forebody has a vee bottom with exaggerated chine flare. The impact loads, moments, and pressures were determined for a range of landing conditions. A normal full-scale landing speed of 86 miles per hour was represented with effective flight paths ranging from 0.6deg to 11.6deg. Landings were made with both fixed trim and free-to-trim mounting of the float over a trim range of -15deg to 12deg into smooth water and into waves having equivalent full-scale length. of 120 feet and heights ranging from 1 to 4 feet. All data and results presented in this report are given in terms of equivalent full-scale values. Summary tables and illustrative plots are used in presenting the material. The following maximum values of load and pressure are those which are apropos for effective flight paths less than 6.5deg which was the maximum value obtained in tests with the XJL-1 hull model representing full-scale landings with vertical velocity of 4.5 feet per second into 4-foot waves. The maximum local pressure on the flat portion of the bottom is 130 pounds per square inch which was measured on a 2-inch-diameter circular area near the step. The maximum local pressure obtained in the curved area near the chines is 200 pounds per square inch. This pressure was also measured near the step.

Steiner, Margaret F.↗

Effects of Hypergravity Exposure on Prolactin Levels in Pre-parturient , Parturient and Lactating Rat Dams

We analyzed the effects of 2.0-g, 1.75-g and 1.5-g hypergravity exposure on plasma concentrations of the lactotrophic hormone, prolactin (PRL), in female rats on pre-parturient (Gestation Day 20), parturient (Post-natal day 0) and lactating (P10) days. PRL levels have been found to be reduced in rat dams around the time of birth following exposure to gravitational loads varying from 2.16 to 3.14-g (Megory et. al., Aviation, Space and Environs 1129-1135, 1984). It has also been reported that at these high gravitational loads, neonatal mortality has been extremely high, suggesting a possible interaction between dam PRL concentration and neonatal outcome. We have previously reported no significant differences in PRL levels of parturient (PO) and lactating (P6 & P 15) dams when exposed to 1.5-g hypergravity, but did observe a slight elevation of PRL on PO and P 15, with a decrease on P6. In the present study, time-bred pregnant dams were exposed to either continuous 2.0-g, 1.75-g or 1.5-g centrifugation, beginning on Gestational day (G) 11 of the rats' 22-day pregnancy. We observed no significant differences in PRL concentrations between SC and any of the HG conditions. On G20 and PO, PRL concentrations of the 2.0-g and 1.5-g groups were slightly elevated as compared to SC. Similar to what we previously reported. PRL secretion was elevated in both HG and SC conditions on the day of birth relative to later during lactation, but on P10 it appeared to be reduced in HG relative to SC dams. These findings suggests that hypergravity slightly elevates plasma concentration of PRL in pre-parturient and lactating rat dams, with effects most pronounced during the periparturitional period and in a direction opposite to that observed following microgravity exposure.

Baer. Lisa A.↗

Full scale GLARE fuselage panel tests

A GLARE fuselage panel, representative of the crown section of the Fokker 100 fuselage in front of the wing, was tested. The panels were loaded by air pressure resulting in tangential stress in the panel by axial loading, representative of both the cabin pressure and the fuselage bending due to taxiing and gust loading. A fatigue test, simulating 180000 flights, followed by static tests were performed. The panel was loaded to failure at 1.32 ultimate load. The test set-up, the uniform strain distribution of the panel, and the fatigue loads applied at high test frequency are described. The use of GLARE leads to a substantial weight reduction without affecting the fatigue static strength.

Vercammen, Roland W. A.↗

Space environmental effects and the solar power satellite

Some preliminary findings regarding the interactions between the space plasma at GEO and the Marshall Space Flight Center January 1978 baseline Satellite Power Systems (SPS) design are summarized. These include the following: (1) the parasitic load will be dominated by photoelectrons and will amount to about 34 MW; (2) material of higher conductivity than kapton should be used for the solar reflector substrate and the solar cell blanket support material; (3) the satellite structure and solar reflector should be tied electrically to midpoint voltage of each solar cell array; and (4) tests should be run on the proposed solar cell cover glass material (synthetic sapphire) to determine if breakdown is expected.

Freeman, J. W.↗