Search NASA⌕ Search

SEARCH · Search NASA

Results for “load shifting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Characterization of solid particle candidates for application in thermal energy storage and concentrating solar power systems

Thermal energy storage (TES) enables concentrating solar power to remain competitive in the renewable energy mix by firming up intermittent solar resource and providing grid services such as load shifting. Free from siting constraints, stand-alone TES systems show promise as a low-cost alternative to traditional pumped-storage hydropower or compressed air energy storage. At the core of all TES technologies is a storage medium, the selection of which governs many aspects of system design and operation. Although the majority of commercial installations utilize molten salts, solid particles can demonstrate stability over wider temperature ranges. This amounts to increased energy storage densities and corresponding reductions in system cost which is essential in achieving low-cost energy storage. In this work, eight solid particle candidates are systematically identified and screened for application in a specific particle-TES system. The five most promising candidates (CARBO CP and HSP, calcined flint clay (CFC), brown fused alumina (BFA), and silica sand) are further characterized by size and morphology for fluidization suitability, flowability for particle transport, and thermal stability. Calcined flint clay and brown fused alumina are eventually down-selected due to thermal instability at the target operational temperature of 1200 °C. Although the physical characteristics of CARBO outperform silica sand in all categories examined, the marginal performance gains are considered insufficient to justify the additional media cost so silica sand is selected as the leading candidate. Within the silica sand (α-quartz) space, the high end of Geldart Group B particles is identified to satisfy the target fluidization regime for the application of interest without compromising particle flowability. Here, in focused testing, Silica 460 is shown to exhibit sufficient stability through long-duration (500-hour) thermal and cyclic testing (1200 °C), 10-hour testing at 1400 °C, and in contact with candidate refractory containment materials. Finally, an average heat capacity of 1.1 J/g∙ °C is measured over 300-1200 °C with a quartz inversion enthalpy (ΔH α-β ) of 10.7J/g.

14 SOLAR ENERGY↗

Thermal Stability of Silica for Application in Thermal Energy Storage

Thermal energy storage (TES) systems have enabled concentrating solar power (CSP) to remain competitive in the modern energy mix by providing economical load shifting grid services and firming up intermittent solar resource. Free from siting constraints, TES also shows promise as an economical alternative to traditional pumped-storage hydropower (PSH) and compressed air energy storage (CAES). As potential thermal energy storage media, some solid particles demonstrate stability over wide temperature ranges which allows for increased sensible energy storage density and is essential in achieving low-cost storage. Silica sand, in the form of a-quartz, is one such candidate. This work presents a brief review of relevant silica thermophysical properties and further investigates the thermal stability of silica particles as a candidate TES media by subjecting them to two different thermal tests: (1) a 500-hour thermal treatment at 1200 degrees C under varied atmospheres; and (2) cycling 25, 50, and 100 times between 300 degrees C and 1200 degrees C. For both tests, particle stability is examined by means of pre- and post-treatment Mie scattering. An additional XRD analysis is conducted for the 500-hour treatment in air. Results indicate limited changes in both particle distribution and crystallographic structure which is promising for the application as solid particle media for thermal energy storage.

concentrating solar power↗

Informing the planning of rotating power outages in heat waves through data analytics of connected smart thermostats for residential buildings

Abstract With climate change, heat waves have become more frequent and intense. Rotating power outages happen when the power supply is unable to meet the cooling demand increase resulting from extreme high temperatures. Power outages during heat waves expose residents to high risks of overheating. In this study, we propose a novel data-driven inverse modelling approach to inform decision makers and grid operators on planning rotating power outages. We first infer the building thermal characteristics using the connected smart thermostat data, and used the estimated thermal dynamics to simulate the thermal resilience during a heat wave event. Our proposed method was tested for the California power outage in August 2020 by using the open source Ecobee Donate Your Data dataset. We found in California the power outage should not last more than two hours during heat waves to avoid overheating risks. Informing the residents in advance so they can prepare for it through pre-cooling is a simple but effective strategy to expand the acceptable power outage duration. In addition to assisting power outage planning, the proposed method can be used for other applications, such as to evaluate a building energy efficiency policy, to examine fuel poverty, and to estimate the load shifting potential of building stocks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hierarchical Transactive Control of Flexible Building Loads Under Distribution LMP

With grid modernization efforts, future distribution networks, which consist of various distributed generators and flexible loads, will be more flexible and active. All new network components of distributed energy resources (DERs) drive and enable the transition towards a market-based distribution net-work that seeks the optimal allocation of all DERs. To address challenges associated with DERs, one promising solution is to utilize demand-side flexibility of building loads facilitated by demand response (DR) programs and provide ancillary grid services through distribution-level markets. Under this new paradigm, this paper proposes an efficient DR management strategy incorporating emerging price signals of distribution markets, i.e., distribution locational marginal price (DLMP), based on a hierarchical transactive control approach. The proposed approach establishes a two-layer decision-making framework; the upper layer formulates a bilevel model to obtain an optimal demand response (ODR) under DLMP, and the lower layer employs model-free control to dispatch the (aggregated) ODR to individual end users. Numerical case studies using a modified IEEE 33 test network are performed to verify the effectiveness of the proposed approach; load shifting and peak shaving for the distribution system operator and payments’ reduction for end users while maintaining their comfort.

Park, Byungkwon↗

Sizing Considerations for EV Dynamic Wireless Charging Systems with Integrated Energy Storage

Roadways with dynamic wireless charging systems (DWCS) enable charge-sustaining in-motion EV charging, which can reduce charging idle time while increasing range capabilities. Spatially distributed transmitter coils are controlled in response to traffic load that varies significantly minute to minute with high power levels, very short charging time, and low system utilization like wind turbine power. Traffic load estimation and localized analysis may guide effective sizing and topology adoption for feasible and scalable DWCS deployment. DWCS traffic load approximation is reviewed with measured Automated Traffic Recorder (ATR) data and statistical distributions being used to create a synthetic load analyzed using proposed metrics quantifying system utilization over time. Lumped coil section segmentation is compared between second-based distance and spatial density analysis methods, offering 17-27% greater system utilization. A peak load shifting method is proposed for traffic redirection across two tracks with optional BESS integration increasing system utilization by 50-60% depending on time-based and power reserve-based sizing and control.

Lewis, Donovin D.↗

Experimental Analysis of Salt Hydrate Latent Heat Thermal Energy Storage System With Porous Aluminum Fabric and Salt Hydrate as Phase Change Material With Enhanced Stability and Supercooling

Phase change materials (PCMs), especially salt hydrates possess high volumetric energy storage capacity in their transition temperature range. These materials are used in applications where it is necessary to store thermal energy due to temporary load shift between demand and availability. Thus, possible applications are HVAC, recovery of waste heat, and defense thermal management. Despite salt hydrates potential, the practical feasibility of latent heat storage with salt hydrates is limited due to low power rating, supercooling, phase segregation, and long-term stability. Its low power rating and long-term stability limits its application in most applications. This work experimentally validates the stability and thermal performance of a compact heat exchanger charged with salt hydrate during melting and freezing. The compact heat exchanger was designed with fins on both the heat transfer fluid (HTF) and salt hydrate PCM side. The thermal performance of the latent heat thermal energy storage system (LHTESS) was evaluated for various operating conditions. The results show that LHTESS could achieve an average heat transfer coefficient of 124 and 87 W/(m2 K) during melting and solidification, respectively. The stability of the system in suppressing supercooling was validated over 800 cycles with nucleating agent and active homogenous nucleation techniques. The supercooling was reduced to 3 °C with zinc hydroxyl nitrate as nucleating agent and less than 1 °C with the active homogenous nucleation technique. The LHTESS showed less than 6% degradation in energy storage capacity over 800 cycles.

42 ENGINEERING↗

Effect of Thermal Expansion Coefficient, Viscosity and Melting Range in Simulation of PCM Embedded Heat Exchangers With and Without Fins

Phase change material heat exchangers (PCMHX) have an important role in integrating renewable energy systems. PCMHX can offer high storage density at various temperatures of interest and can be used for grid load shifting purposes. Numerical models enable engineers to estimate PCMHX performance for different design parameters and operating conditions. Modeling phase change phenomena is challenging due to the complex time-dependent nature of the process. The accuracy of models is highly sensitive to PCM thermo-physical properties. Thermal expansion coefficient (β), viscosity (μ) and melting temperature range (MR) of a PCM are important properties, especially when natural convection is not negligible. In PCMHX modeling, using less than accurate values for these properties can have significant impact on the simulation outcomes. These properties and discussions thereof are not readily available in the literature. This paper presents a brief review of the literature and a numerical study investigating the model sensitivity to the above-mentioned properties for PCMHX with and without fins. CFD is used to evaluate the charging (melting) phenomena. The study quantifies the impact of uncertainty in these properties on the melting rate and temperature profile. Constant wall temperature was considered as heat source with no heat loss to ambient. Here, the results show that β and μ has significant effect on the melting rate and evolution of the melting front. For a non-finned domain when comparing results for different published values of β and μ, the deviation in melting time can be up to 12.9% and 57.6% respectively. For high wall temperatures, change in melting range did not impact melting time. But when the wall temperature is reduced, up to 9.8% deviation in melting time is observed.

CFD↗

Ontologies at Work: Analyzing Information Requirements for Model Predictive Control in Buildings

Model Predictive Control (MPC) has shown significant potential for improving energy efficiency, indoor air quality and occupant comfort of buildings. MPC-based control algorithms have also shown the ability to shift loads and optimize for multiple objectives, including but not limited to reducing the green-house gas emissions, energy costs and peak demand. However, one of the main implementation challenges of these control algorithms is the integration and configuration effort needed to deploy a supervisory MPC controller in a building. By assigning standardized references to information sources and control points in buildings, existing studies have shown that semantic ontologies and corresponding queries have the potential to ease the deployment of such controllers. Yet, the use of semantic information to ease the deployment processes of MPC controllers is still limited. In this paper, we review three MPC experiments and synthesize the information requirements of these optimization problems. We then turn to existing and upcoming semantic ontologies such as Brick, SAREF and ASHRAE Standard 223 to represent these requirements, evaluating their potential to support the implementation of an MPC controller. This investigation concludes with a discussion of existing opportunities and open questions that the community should explore to support more streamlined MPC implementations.

Prakash, Anand Krishnan↗

EmissionsFlexibility

Software to calculate the how changes in electricity consumption change the generator which provides the electricity. This is applied to find how load shifting (e.g. data centers) impact the carbon emissions of the power grid.

Rhodes, Noah↗

HP-FLEX: Field demonstration of the semantics-driven configuration of a Model Predictive Control system to make heat pumps flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

Cost targets to achieve commercially viable thermal storage in buildings

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. In this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. Lastly, the economic value implied by different types of deferred peak power plants were reviewed. The full value of TES to the entire society consists of value to the utility, OEMs, facility installers, and other stakeholders. This report focuses on the value to the utility with emphasis on the deferred capital of peak power plant. The value from the deferred capital of peak power plant is manifested to the customer in the form of demand reduction program and Time-of-Use utility rate program. In this report, an initial proxy of the value of TES is made by assuming the deferred capital cost of power plant is the full value to reduce peak demand. Three levels of financial value of TES systems were assessed. Two are currently available to some residential customers: (1) the benefit from TOU pricing alone and (2) the benefit from TOU pricing in combination with DR incentive programs. The third level was computed as the full cost of deferred capital cost of peaking power plants. This represents the potential value that could be gained by the utilities or conceivably be offered to consumers.

25 ENERGY STORAGE↗

Models and Strategies for Optimal Demand Side Management in the Chemical Industries

Deregulation and the increase of renewable electricity generation from wind and solar photovoltaics have transformed the U.S. electricity market. Economic and environmental benefits notwithstanding, the presence of renewables has increased variability and uncertainty on the supply side of the grid. Managing demand, rather than generation – a strategy referred to as “demand response (DR)” – is an attractive approach for mitigating this imbalance. DR efforts aim to reduce electricity usage during peak demand times, lessening stress on the grid. Industrial users are particularly attractive entities for DR participation since they present large, localized loads that can provide significant relief on grid demand and –unlike other large loads, such as buildings – are minimally dependent on human needs and preferences. In this project, we accomplished three main objectives. (1) We developed data-driven low-order DR scheduling-relevant dynamic models of chemical processes. Concurrently, we studied the formulation and solution of the associated optimal DR production scheduling problems. (a) A prototype air separation unit (ASU) model was used to generate simulated operating data for initial modeling efforts, which enabled the later use of industrial data for data-driven modeling. (b) We utilized Hammerstein-Wiener (HW) and Finite Step Response (FSR) models to represent nonlinear plant dynamics. (c) The HW models were linearized using exact linearization so they could potentially be embedded in power system models, which are formulated as mixed integer linear programs (MILPs). (d) We solved DR optimization problems under uncertainty and found that even naïve predictions of electricity price and product demand led to significant cost savings benefits. (2) Our DR scheduling optimization problem formulations are amenable to real-time solution. (a) We utilized Lagrangian Relaxation (LR) to efficiently solve the optimization problem by decoupling subproblems linked by complicating constraints. (b) We have achieved computation times for the 3-day DR scheduling problem of an ASU as low as 1.88 minutes. (3) Our representations of the DR behavior of chemical process as grid-level batteries were embedded in power system models. (a) For a small-scale grid, we found that incorporating the dynamics of the chemical plant in the optimal power flow calculations resulted in better resource management leading to up to 15% and 46% cost reduction for the grid and chemical plant operations, respectively, during periods of power line congestion. We have published several works dedicated to modeling and solving DR optimization problems from the user side. These were published in top peer-reviewed journals and are summarized in this report. The most recent work (and papers in preparation) considers DR scheduling from the grid side. Future efforts will consider networked plants (e.g., air separation units operating on a common pipeline) for DR participation, which is expected to amplify the capabilities of industrial DR participants to perform load-shifting. Our consideration of uncertainty in DR has inspired future directions in this area as well: we plan to develop multistage methods to fully account for the effects of uncertainty in DR scheduling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploration of Domain Aware Machine Learning for Grid Analytics: Transfer-Learnt Energy Models to Assist Buildings Control with Sparse Field Data

Buildings are a primary consumer of energy in the United States and are also increasingly being perceived as providers of grid services such as load shifting, shedding and modulation. High fidelity models of building energy consumption are needed to set appropriate baselines for measurement and verification (M&V) of controllers designed for energy efficient operation of buildings and to enable buildings to provide grid services via. participation in demand response programs. State-of-the-art building energy modeling techniques either rely on Physics based models, or extensive instrumentation of the building envelope to gather “big” data to train machine learning based models such as deep neural networks. While Physics based models are often limited by their accuracy, it is not always feasible to gather a significant amount of field data required to train machine learning based models with sufficient accuracy. In this paper, we explore the use of transfer learning-based strategies to address unsatisfactory accuracy of models for estimating building energy consumption when available field data for training is sparse or of unacceptable quality. In particular, we transfer knowledge in the form of data and parameters, from Physics based simulation frameworks to the field to improve the model accuracy, thus resulting in a Physics-informed Machine Learning framework. We evaluated the efficacy of our approach on field data collected from six commercial buildings and our results indicate that the proposed transfer learning based models provide comparative (and in some cases better) accuracy than state-of-the-art machine learning and deep learning solutions, with just one month of field data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nodal Capacity Expansion Modeling with ReEDS: A Case Study of the RTS-GMLC Test System

Test systems play an important role in power systems analysis and are used extensively for a wide range of purposes like reliability analysis, production cost modeling, studying the impacts of load shifting, and many more. These test systems have continued to evolve over the years to keep pace with changing system compositions due to technology and policy changes. In this work, we apply the Regional Energy Deployment System (ReEDS) model, a large-scale capacity expansion model (CEM), on the nodal RTS-GMLC system to perform capacity expansion of the bus-level test system. This work both demonstrates that a large-scale CEM can successfully be applied to nodal systems, and that the CEM can allow a test system to be evolved to meet desired criteria. The process allowed the coupling of CEM data not available in the test system (such as capital costs) with test system data to provide plausible system evolutions in line with scenario specifications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Measure Documentation: Dispatch Schedule Generation for Demand Flexibility Measures

This supplemental document describes the methodology used for determining the dispatch timing of various EUSS demand flexibility measures. Demand flexibility measures are designed to reduce/dispatch electricity demand in buildings during especially beneficial/critical times. The method used in this work utilizes predictions of building loads to generate a schedule that reflects the periods when the building's daily peak load occurs to support decision making in demand flexibility measures. The dispatch schedule generation method described in this document creates an hourly schedule that includes a load dispatch (peak) window for each day for a whole year based on load prediction, with options using different prediction methods: perfect prediction, bin-sampling method, fixed schedule, and outdoor air temperature (OAT)-based prediction method. The perfect prediction method performs a simulation to obtain the annual load profile as predicted load, representing the scenario of perfect load prediction. The bin-sampling method (1) categorizes days into representative bins by temperature characteristics, (2) performs simulations on sample days from each of those bins to create representative (or predicted) load, and (3) assigns representative loads for all days in a year based on the bin categorization. The fixed schedule method defines uniform start and end time of peak window with assumed fixed daily peak time, for all days in a season or a year. The OAT-based prediction method uses the statistics of OAT (minimum and maximum) as the indicators of peak load, with specified delay response time from building loads to temperature. Given the load prediction, daily peak periods are determined as a time window with specified length in each day that include the predicted daily peak load and with a secondary rule such as maximizing energy saving potential. The dispatch schedule generation method is not a standalone measure and is intended to be combined with other demand flexibility measures that could leverage the peak schedule and apply demand controls on specific systems or devices for demand response, such as measures described in "Measure Documentation - Thermostat Control for Load Shedding" and "Measure Documentation - Thermostat Control for Load Shifting".

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

Glauber’s Salt Composites for HVAC Applications: A Study on the Use of the T-History Method with a Modified Data Evaluation Methodology

Phase change materials (PCMs) can be utilized in buildings for peak load shifting in air conditioning systems, and the use of salt hydrate-based PCMs can reduce the cost of thermal energy storage devices. Glauber’s salt is an economical salt hydrate PCM with a melting point of around 32 °C. However, the desired melting range typically falls between 18 and 22 °C for building air conditioning applications. Although many researchers have characterized Glauber’s salt and its composites with modified melting points, enthalpy–temperature curves for composites of Glauber’s salt and NaCl are unavailable. In this study, we report the melting and solidification enthalpy–temperature curves for two different composites of Glauber’s salt and NaCl with a melting point of 21 °C obtained by the T-history method. Both composites contain NaCl to suppress the melting point, borax to reduce supercooling, and sodium polyacrylate as a thickener to enhance cyclic stability. The first composite with 12 wt.% NaCl demonstrated 139 kJ·kg−1 of latent heat of fusion, and the second composite with 9 wt.% NaCl demonstrated 171 kJ·kg−1. Both the composites have high volumetric energy densities compared to their organic counterparts with similar melting points.

Chemistry↗