Search NASA⌕ Search

SEARCH · Search NASA

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

UNCERTAINTIES FOR IN-REACTOR TESTING OF TRITIUM LOADED GETTERS WITH TEMPERATURE CONTROL

The fourth experiment in TPBAR Materials Irradiation Separate-Effects Test (TMIST) series (TMIST-4) is planned to experimentally determine the effect of neutron irradiation on the equilibrium vapor pressure of tritium over a tritium loaded Nickel-Plated Zirconium (NPZ) getter in a simulated TPBAR service environment. This pressure will be used to estimate the tritium permeation rate. In the thermal design in the TMIST-4, two evaluations are required. 1) The cladding temperature is calculated to estimate the feasibility of detecting potential irradiation enhancement of the partial pressure for an NPZ getter. This work is required to obtain a precise cladding temperature for measurement of a low tritium partial pressure. This work has been completed and indicated that the required/target cladding temperatures based on the TMIST-4 test plan can be satisfied under the test condition range by modifying the capsule component shapes and inserting a thermally conductive metal sleeve. 2) The evaluation of uncertainties associated with the test design and operation is performed. This includes fabrication tolerances, and power and nuclear operating conditions. These factors will impact the component temperatures inside capsules and resulting the tritium partial pressure. The tritium permeation rate is a function of temperature and tritium partial pressure. The prediction of tritium permeation rates affects the feasibility of obtaining measurement resolutions required to reach reasonable conclusion for potential irradiation enhanced performance. This work will investigate the uncertainties.

TTP, TPBAR, TMIST-4, TPBAR Materials Irradiation S↗

A Methodology for Loading the Advanced Test Reactor Driver Core for Experiment Analysis

In support of experiments in the ATR, a new methodology was devised for loading the ATR Driver Core. This methodology will replace the existing methodology used by the INL Neutronic Analysis group to analyze experiments. Studied in this paper was the as-run analysis for ATR Cycle 152B, specifically comparing measured lobe powers and eigenvalue calculations.

42 ENGINEERING↗

High Powered Tests of Dielectric Loaded High Pressure RF Cavities for Use in Muon Cooling Channels

Bright muon sources require six dimensional cooling to achieve acceptable luminosities. Ionization cooling is the only known method able to do so within the muon lifetime. One proposed cooling channel, the Helical Cooling Channel, utilizes gas filled radio frequency cavities to both mitigate RF breakdown in the presence of strong, external magnetic fields, and provide the cooling medium. Engineering constraints on the diameter of the magnets within which these cavities operate dictate the radius of the cavities be decreased at their nominal operating frequency. To accomplish this, one may load the cavities with a larger dielectric material. Alumina of purities ranging from 96 to 99.8% was tested in a high pressure RF test cell at the MuCool Test Area at Fermilab. The results of breakdown studies with pure nitrogen gas, and oxygen-doped nitrogen gas indicate the peak surface electric field on the alumina ranges between 10 and 15 MV/m. How these results affect the design of a prototype cooling channel cavity will be discussed.

43 PARTICLE ACCELERATORS↗

ASME AG-1 Section FC Qualified HEPA Filters; a Particle Loading Comparison - 13435

High Efficiency Particulate Air (HEPA) Filters used to protect personnel, the public and the environment from airborne radioactive materials are designed, manufactured and qualified in accordance with ASME AG-1 Code section FC (HEPA Filters) [1]. The qualification process requires that filters manufactured in accordance with this ASME AG-1 code section must meet several performance requirements. These requirements include performance specifications for resistance to airflow, aerosol penetration, resistance to rough handling, resistance to pressure (includes high humidity and water droplet exposure), resistance to heated air, spot flame resistance and a visual/dimensional inspection. None of these requirements evaluate the particle loading capacity of a HEPA filter design. Concerns, over the particle loading capacity, of the different designs included within the ASME AG-1 section FC code[1], have been voiced in the recent past. Additionally, the ability of a filter to maintain its integrity, if subjected to severe operating conditions such as elevated relative humidity, fog conditions or elevated temperature, after loading in use over long service intervals is also a major concern. Although currently qualified HEPA filter media are likely to have similar loading characteristics when evaluated independently, filter pleat geometry can have a significant impact on the in-situ particle loading capacity of filter packs. Aerosol particle characteristics, such as size and composition, may also have a significant impact on filter loading capacity. Test results comparing filter loading capacities for three different aerosol particles and three different filter pack configurations are reviewed. The information presented represents an empirical performance comparison among the filter designs tested. The results may serve as a basis for further discussion toward the possible development of a particle loading test to be included in the qualification requirements of ASME AG-1 Code sections FC and FK[1]. (authors)

42 ENGINEERING↗

Evaluation of Dynamic Mechanical Loading as an Accelerated Test Method for Ribbon Fatigue

Dynamic Mechanical Loading (DML) of photovoltaic modules is explored as a route to quickly fatigue copper interconnect ribbons. Results indicate that most of the interconnect ribbons may be strained through module mechanical loading to a level that will result in failure in a few hundred to thousands of cycles. Considering the speed at which DML may be applied, this translates into a few hours o testing. To evaluate the equivalence of DML to thermal cycling, parallel tests were conducted with thermal cycling. Preliminary analysis suggests that one +/-1 kPa DML cycle is roughly equivalent to one standard accelerated thermal cycle and approximately 175 of these cycles are equivalent to a 25-year exposure in Golden Colorado for the mechanism of module ribbon fatigue.

14 SOLAR ENERGY↗

Evaluation of Dynamic Mechanical Loading as an Accelerated Test Method for Ribbon Fatigue

Dynamic Mechanical Loading (DML) of photovoltaic modules is explored as a route to quickly fatigue copper interconnect ribbons. Results indicate that most of the interconnect ribbons may be strained through module mechanical loading to a level that will result in failure in a few hundred to thousands of cycles. Considering the speed at which DML may be applied, this translates into a few hours of testing. To evaluate the equivalence of DML to thermal cycling, parallel tests were conducted with thermal cycling. Preliminary analysis suggests that one +/-1 kPa DML cycle is roughly equivalent to one standard accelerated thermal cycle and approximately 175 of these cycles are equivalent to a 25-year exposure in Golden Colorado for the mechanism of module ribbon fatigue.

14 SOLAR ENERGY↗

Assessment of bearing capacity of axially loaded monopiles based on centrifuge tests

The monopile has been widely used to support offshore and coastal structures. A series of centrifuge tests has been performed to investigate the bearing capacity of large diameter monopiles in sandy soil. Both static tests and cyclic tests have been conducted for open-ended and close-ended model piles, and the effects of influence factors, such as loading rates, embedment depths, and loading histories are considered. The piles are then loaded by a sequence of compressive-tensile loadings to estimate the tension capacity, from which the shaft friction is derived. The cyclic load tests are performed with five varying load intensities, and the accumulated settlement is assessed. The centrifuge tests indicate that the pile bearing capacity tends to increase with the initial penetration depth, and the stress state of soil greatly influences the pile behavior. The tensile shaft friction is smaller compared to the compression test. The capacities of the piles reduce significantly under the axial cyclic load, and the maximum cyclic load intensity should be limited to 75% of the ultimate bearing capacity. The API design method is used to calibrate with the centrifuge test results. The method overestimates the bearing capacity at larger depths, and a conservative reduction factor is required.

17 WIND ENERGY↗

LANL Phase 3 Test Plan For Container Loading to Support the Fire-Induced Pressure Response and Failure Characterization of PCV/SCV/3013 Containers

Fire testing of 3013 containers loaded with surrogate materials and water will be conducted to determine the response of 3013 containers stored in K-Area Complex (KAC) to a facility fire. Based on the proposal for the test configuration and loading, the objectives of the fire test are as follows: 1. “To increase understanding about the pressure and temperature conditions at which failure occurs; 2. To determine the allowable moisture for which failure will not occur under specified fire conditions, and 3. To increase understanding regarding the effects of salts on the pressurization, corrosion, and potential failure of the container.” Surrogate materials will be prepared at Los Alamos National Laboratory (LANL) and loaded in the 3013 containers. The containers will then be welded at LANL and shipped to Savannah River Site (SRS) for the installation of fittings and leak testing.

42 ENGINEERING↗

A Methodology for Loading the Advanced Test Reactor Driver Core for Experiment Analysis

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) is one of the premier irradiation facilities in the world. The ATR hosts experiments from a variety of laboratories, companies, and disciplines. Because of its flexibility in providing customized irradiation conditions to experiments, such as coolant chemistry, temperature, and reactor power, analysis for experiments, both from a programmatic and safety perspective, can be a challenging endeavor. Because of these experiment variables, there is always an effort to improve upon the existing analysis methodology in order to provide the sponsor of any given experiment with the most accurate predictions possible. The paper discusses the effort to improve upon the methodology for loading the ATR driver core for experiment analysis. Experiment analysis at INL is generally broken up into three separate disciplines: neutronics, thermal-hydraulics, and structural. The focus of this paper is neutronics analysis. After the experiment has a preliminary design, the neutronics analyst will create a model in the Monte Carlo N-Particle (MCNP) transport code to calculate fuel and material heating rates from MCNP tallies and provide those to the thermal-hydraulics analyst, and calculate reactivity worths, perturbation on the axial fission profile of the ATR driver core by the experiment, void worths, and experiment backup worths. Also, there are usually several programmatic parameters that the experiment sponsor requests that the neutronics analyst calculates. These can include heat generation rates, burnup and displacements per atom (DPA). In order to accurately analyze these parameters, an important input into the physics analyst's MCNP model is the loading of the ATR driver core. The ATR driver core consists of 40, 19-plate highly-enriched uranium (HEU) fuel elements, arranged in a serpentine shape, as pictured in Figure 1. The ATR driver core is responsible for the vast majority of the thermal power of the reactor and the nuclear interactions with the experiments being irradiated in ATR. A unique feature of ATR is the 'power tilt' across the reactor. A power tilt means that the Northwest, Northeast, Southwest, and Southeast Lobes of ATR frequently operate at different powers, providing different irradiation conditions for the experiments in and around the lobes of the reactor. In order to achieve lobe power splits, different fuel elements for each of the 40 positions are chosen by ATR Reactor Engineering so that lobe power splits can be maintained during an operating cycle. A typical fuel loading for an ATR cycle consists of 14 to 18 new fuel elements and 2 to 26 depleted fuel elements. These loadings are typically chosen from three different types of fuel elements. All three ATR fuel element types share a common design, spelled out in Chapter 4 of the ATR Safety Analysis Report (SAR). The fuel element meat is HEU UAlx dispersion fuel sandwiched between aluminum cladding with a length of 121.92 cm (4 ft), with 19 plates per fuel element. The three variations of this common design are designated by the first two letters in their serial numbers: XA, YA, and NB. XA elements are most commonly used. These elements have nominally 1075 g of uranium-235 and 0.66 g of boron-10. The NB elements have the same uranium-235 loading as the XA elements, but no boron in any plates. These elements are used when excess reactivity is needed. The YA elements have the same loading as the XA elements, except that the outermost plate (Plate 19) has no boron or uranium. These elements are used to mitigate aged reflector damage. In order to accurately model the ATR driver core, all three types of fuel elements must be accounted for in the MCNP model. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computational Methods to Characterize Panel Loading Conditions for Accelerated Testing

Panel cracking and degradation due to wind loading are known to have a detrimental effect on power output. Recreating these damaging conditions in a controlled experimental setting requires an understanding of the loads being generated at the panel surface as a function of both wind speed, wind direction, and panel orientation. To better understand these relationships, a computational fluid dynamics (CFD) simulation package was constructed using an open-source Python library for solving partial differential equations with the finite element method. This CFD package allows the simulated wind speed and panel orientation of a multi-panel array to be easily changed and provides the capability to measure the traction forces at discrete points along the sun-facing and ground-facing surface of an interior panel residing in the wake of one or more upstream panels. A parameter exploration was performed in which the panel angle was varied in even increments from -70 deg to 70 deg and the wind speed was varied from 2 to 30 m/s. During post processing, the measured traction along the panel surface was averaged spatially and interpreted as a time-varying signal, where further processing of this signal yielded the root mean square amplitude and a characteristic frequency associated with the loading. This study found that higher wind speeds are generally associated with increased amplitude of loading and that the panel orientation angle can significantly exacerbate or mitigate this loading. These outcomes are presented along with current work on higher-fidelity verification simulations and recommendations for performing accelerated experimental testing.

loading↗

Measured Performance of Residential Dehumidifiers Under Cyclic Operation

Residential construction practices are progressing toward higher levels of energy efficiency. A proven strategy to save energy is to simultaneously increase building insulation levels and reduce outdoor air infiltration. Overall, this strategy results in a shift in the mix of latent and sensible space conditioning loads, requiring proportionally more moisture to be removed compared to standard homes. In this project, researchers at the National Renewable Energy Laboratory (NREL) developed steady state performance maps to predict dehumidifier performance at a variety of indoor conditions. However, installed heating, ventilating, and air-conditioning (HVAC) equipment rarely operates at steady state. Part load performance testing of residential dehumidifiers is not mandated by current test standards. Therefore, the team tested the part load performance of four residential dehumidifiers in NREL’s Advanced HVAC Systems Laboratory . The part load efficiency of each dehumidifier was measured under 13 cycling scenarios, and combined with NREL field data to develop part load fraction (PLF) performance curves under realistic cycling scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗