Search NASA⌕ Search

SEARCH · Search NASA

Results for “local control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Stereotactic Radiosurgery of the Postoperative Resection Cavity for Brain Metastases

Purpose: The purpose of this study was to analyze results of adjuvant stereotactic radiosurgery (SRS) targeted at resection cavities of brain metastases without whole-brain irradiation (WBI). Methods and Materials: Patients who underwent SRS to the tumor bed, deferring WBI after resection of a brain metastasis, were retrospectively identified. Results: Seventy-two patients with 76 cavities treated from 1998 to 2006 met inclusion criteria. The SRS was delivered to a median marginal dose of 18.6 Gy (range, 15-30 Gy) targeting an average tumor volume of 9.8 cm{sup 3} (range, 0.1-66.8 cm{sup 3}). With a median follow-up of 8.1 months (range, 0.1-80.5 months), 65 patients had follow-up imaging assessable for control analyses. Actuarial local control rates at 6 and 12 months were 88% and 79%, respectively. On univariate analysis, increasing values of conformality indices were the only treatment variables that correlated significantly with improved local control; local control was 100% for the least conformal quartile compared with 63% for the remaining quartiles. Target volume, dose, and number of sessions were not statistically significant. Conclusions: In this retrospective series, SRS administered to the resection cavity of brain metastases resulted in a 79% local control rate at 12 months. This value compares favorably with historic results with observation alone (54%) and postoperative WBI (80-90%). Given the improved local control seen with less conformal plans, we recommend inclusion of a 2-mm margin around the resection cavity when using this technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Matched-Pair Analysis Comparing Whole-Brain Radiotherapy Plus Stereotactic Radiosurgery Versus Surgery Plus Whole-Brain Radiotherapy and a Boost to the Metastatic Site for One or Two Brain Metastases

Purpose: To compare the results of whole-brain radiotherapy plus stereotactic radiosurgery (WBRT+SRS) with those of surgery plus whole-brain radiotherapy and a boost to the metastatic site (OP+WBRT+boost) for patients with one or two brain metastases. Methods and Materials: Survival, intracerebral control, and local control of the treated metastases were retrospectively evaluated. To reduce the risk of selection bias, a matched-pair analysis was performed. The outcomes of 47 patients who received WBRT+SRS were compared with those of a second cohort of 47 patients who received OP+WBRT+boost. The two treatment groups were matched for the following potential prognostic factors: WBRT schedule, age, gender, performance status, tumor type, number of brain metastases, extracerebral metastases, recursive partitioning analysis class, and interval from tumor diagnosis to WBRT. Results: The 1-year survival rates were 65% after WBRT+SRS and 63% after OP+WBRT+boost (p = 0.19). The 1-year intracerebral control rates were 70% and 78% (p = 0.39), respectively. The 1-year local control rates were 84% and 83% (p = 0.87), respectively. On multivariate analyses, improved survival was significantly associated with better performance status (p = 0.009), no extracerebral metastases (p = 0.004), recursive partitioning analysis Class 1 (p = 0.004), and interval from tumor diagnosis to WBRT (p = 0.001). Intracerebral control was not significantly associated with any of the potential prognostic factors. Improved local control was significantly associated with no extracerebral metastases (p = 0.037). Conclusions: Treatment outcomes were not significantly different after WBRT+SRS compared with OP+WBRT+boost. However, WBRT+SRS is less invasive than OP+WBRT+boost and may be preferable for patients with one or two brain metastases. The results should be confirmed by randomized t0011ria.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High‐Nickel Heterostructured Cathodes with Local Stoichiometry Control for High‐Voltage Operation

The growing demand for lithium‐ion batteries to power electric vehicles and other energy‐dense devices continues to fuel the need for cathodes of increasingly higher nickel in cathodes. The relentless pursuit of high Ni content, however, raises concerns on compromising cell lifetime and safety, especially under high‐voltage operation. Alternative to the traditional design of uniform or core–shell composition, we report a rational control of local stoichiometry in high‐Ni cathodes, enabling their high thermal and cycling stabilities—up to 258 °C at the fully charged state and 91.4% capacity retention for 100 cycles between 2.7 and 4.4 V. Multimodal synchrotron X‐ray characterization unveils the heterostructure of secondary particles, featuring a high‐Ni core (LiNi 0.90 Mn 0.05 Co 0.05 O 2 ) covered by a thin Ni‐gradient layer that remains stable over prolonged cycling due to suppressed oxygen release and structural deterioration. This work underlines, the intricate interplay between local stoichiometry and redox reactions in stabilizing high‐Ni cathodes for high‐voltage operation while ensuring safety.

36 MATERIALS SCIENCE↗

Local access control system management using domain information updates

Systems and methods are presented for managing physical access to an access-controlled area using a local access control system. In certain embodiments, information that may be used in access control determinations managed by a remote domain controller may be communicated to a local access control system for use in connection with local access control determinations performed by the access control system independent of the domain controller. In some embodiments, such a configuration may allow for access control determinations to be performed when communication with the domain controller is interrupted and/or otherwise limited.

Masters, George W.↗

Local access control system management using domain information updates

Systems and methods are presented for managing physical access to an access-controlled area using a local access control system. In certain embodiments, information that may be used in access control determinations managed by a remote domain controller may be communicated to a local access control system for use in connection with local access control determinations performed by the access control system independent of the domain controller. In some embodiments, such a configuration may allow for access control determinations to be performed when communication with the domain controller is interrupted and/or otherwise limited.

Masters, George W.↗

Local optical control of ferromagnetism and chemical potential in a topological insulator

Many proposed experiments involving topological insulators (TIs) require spatial control over time-reversal symmetry and chemical potential. We demonstrate reconfigurable micron-scale optical control of both magnetization (which breaks time-reversal symmetry) and chemical potential in ferromagnetic thin films of Cr-(Bi,Sb) 2 Te 3 grown on SrTiO 3 . By optically modulating the coercivity of the films, we write and erase arbitrary patterns in their remanent magnetization, which we then image with Kerr microscopy. Additionally, by optically manipulating a space charge layer in the underlying SrTiO 3 substrates, we control the local chemical potential of the films. This optical gating effect allows us to write and erase p-n junctions in the films, which we study with photocurrent microscopy. Both effects are persistent and may be patterned and imaged independently on a few-micron scale. As a result, dynamic optical control over both magnetization and chemical potential of a TI may be useful in efforts to understand and control the edge states predicted at magnetic domain walls in quantum anomalous Hall insulators.

36 MATERIALS SCIENCE↗

Low-Speed Performance Enhancement using Localized Active Flow Control: Integration Study of Localized Active Flow Control on a Performance Reference Aircraft (3/4)

A study of conceptual integration and performance aspects of localized active flow control (AFC) technology onto wings of short-to-medium-range project passenger airplanes is summarized. Using predicted aerodynamic performance improvement opportunities on the CFD Reference Aircraft, estimated benefit opportunities for conceptual implementation of studied wing localized active flow control (AFC) technology for low-speed (take-off and landing) application on a Performance Reference Aircraft configuration are presented. Using conceptual AFC systems and structural integration weight penalties for studied concepts, potential relevant net performance benefits can be obtained with reliable AFC in takeoff and landing. The conceptual integration study identifies potential promising localized wing AFC application opportunities for high-lift conditions using energy sources for modern aircraft. Material benefits are estimated for take-off and landing configurations for selected localized AFC applications. Next steps to refine and expand results of investigated topics, as well as possible other local AFC wing applications, are suggested.

AFC↗

MPC-Based Local Voltage Control Strategy of DGs in Active Distribution Networks

The increasing penetration of distributed generators (DGs) exacerbates the voltage violations in active distribution networks (ADNs). The commonly used centralized voltage control may aggravate the burden of computation and communication. Local voltage control can realize fast response to frequent voltage fluctuations. However, effective local control for DGs still needs to be further investigated. In this paper, a model predictive control (MPC)-based local voltage control strategy of DGs is proposed to cope with voltage violation problems and enhance the adaptation to the DG volatility. DGs are regulated with local Q-V control curves to respond to voltage fluctuations rapidly. Based on the dynamic network partition, a unified control curve for DGs is set in the same area to realize efficient operation. To further improve the performance of voltage control, the parameter tuning of control curves is regularly conducted based on decentralized inter-area coordination with the rolling of the control horizon. Finally, case study is verified on the modified IEEE 33-node distribution system. The proposed local control strategy of DGs can effectively improve the voltage profile and reduce power losses of the whole network without high computation and communication burden.

active distribution network (ADN)↗

Dose-Volume Histogram Parameters and Local Tumor Control in Magnetic Resonance Image-Guided Cervical Cancer Brachytherapy

Purpose: To investigate the value of dose-volume histogram (DVH) parameters for predicting local control in magnetic resonance (MR) image-guided brachytherapy (IGBT) for patients with cervical cancer. Methods and Materials: Our study population consists of 141 patients with cervical cancer (Stages IB-IVA) treated with 45-50 Gy external beam radiotherapy plus four times 7 Gy IGBT with or without cisplatin. Gross tumor volume (GTV), high-risk clinical target volume (HRCTV), and intermediate-risk clinical target volume (IRCTV) were contoured, and DVH parameters (minimum dose delivered to 90% of the volume of interest [D90] and D100) were assessed. Doses were converted to the equivalent dose in 2 Gy (EQD2) by applying the linear quadratic model ({alpha}/{beta} = 10 Gy). Groups were defined for patients with or without local recurrence (LR) in the true pelvis for tumor size at diagnosis (GTV at diagnosis [GTVD] of 2-5 cm (Group 1) or greater than 5 cm (Group 2) and for tumor size response at IGBT (HRCTV) of 2-5 cm (Group 2a) or greater than 5 cm (Group 2b). Results: Eighteen LRs were observed. The most important DVH parameters correlated with LR were the D90 and D100 for HRCTV. Mean D90 and D100 values for HRCTV were 86 {+-} 16 and 65 {+-} 10 Gy, respectively. The D90 for HRCTV greater than 87 Gy resulted in an LR incidence of 4% (3 of 68) compared with 20% (15 of 73) for D90 less than 87 Gy. The effect was most pronounced in the tumor group (Group 2b). Conclusions: We showed an increase in local control in IGBT in patients with cervical cancer with the dose delivered, which can be expressed by the D90 and D100 for HRCTV. Local control rates greater than 95% can be achieved if the D90 (EQD2) for HRCTV is 87 Gy or greater.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hybrid Optical–Thermal Antennas for Enhanced Light Focusing and Local Temperature Control

Metal nanoantennas supporting localized surface plasmon resonances have become an indispensable tool in bio(chemical) sensing and nanoscale imaging applications. The high plasmon-enhanced electric field intensity in the visible or near-IR range that enables the above applications may also cause local heating of nanoantennas. We present a design of hybrid optical–thermal antennas that simultaneously enable intensity enhancement at the operating wavelength in the visible and nanoscale local temperature control. We demonstrate a possibility to reduce the hybrid antenna operating temperature via enhanced infrared thermal emission. We predict via rigorous numerical modeling that hybrid optical–thermal antennas that support high-quality-factor photonic-plasmonic modes enable up to 2 orders of magnitude enhancement of localized electric fields and of the optical power absorbed in the nanoscale metal volume. At the same time, the hybrid antenna temperature can be lowered by several hundred degrees with respect to its all-metal counterpart under continuous irradiance of 104–105 W/m2. The temperature reduction effect is attributed to the enhanced radiative cooling, which is mediated by the thermally excited localized surface phonon polariton modes. We further show that temperature reduction under even higher irradiances can be achieved by a combination of enhanced radiative and convective cooling in hybrid antennas. To conclude, we demonstrate how hybrid optical–thermal antennas can be used to achieve strong localized heating of nanoparticles while keeping the rest of the optical chip at low temperature.

42 ENGINEERING↗

Attitude Control by Localized Outgassing

Attitude control of levitated object achieved by using laser to vaporize selectively sublimate coating. Laser heats material that will sublime or outgas. To obtain torque reaction force vector from subliming material must not pass through center-of-mass of object. Laser provides beam suitable for controlling objects in noncontact manufacturing processes in acoustic levitation chambers.

Elleman, D. D.↗

Dose-Response Relationship for Image-Guided Stereotactic Body Radiotherapy of Pulmonary Tumors: Relevance of 4D Dose Calculation

Purpose: To evaluate outcome after image-guided stereotactic body radiotherapy (SBRT) for early-stage non-small-cell lung cancer (NSCLC) and pulmonary metastases. Methods and Materials: A total of 124 patients with 159 pulmonary lesions (metastases n = 118; NSCLC, n = 41; Stage IA, n = 13; Stage IB, n = 19; T3N0, n = 9) were treated with SBRT. Patients were treated with hypofractionated schemata (one to eight fractions of 6-26 Gy); biologic effective doses (BED) to the clinical target volume (CTV) were calculated based on four-dimensional (4D) dose calculation. The position of the pulmonary target was verified using volume imaging before all treatments. Results: With mean/median follow-up of 18/14 months, actuarial local control was 83% at 36 months with no difference between NSCLC and metastases. The dose to the CTV based on 4D dose calculation was closely correlated with local control: local control rates were 89% and 62% at 36 months for >100 Gy and <100 Gy BED (p = 0.0001), respectively. Actuarial freedom from regional and systemic progression was 34% at 36 months for primary NSCLC group; crude rate of regional failure was 15%. Three-year overall survival was 37% for primary NSCLC and 16% for metastases; no dose-response relationship for survival was observed. Exacerbation of comorbidities was the most frequent cause of death for primary NSCLC. Conclusions: Doses of >100 Gy BED to the CTV based on 4D dose calculation resulted in excellent local control rates. This cutoff dose is not specific to the treatment technique and protocol of our study and may serve as a general recommendation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose-Rate Brachytherapy Boost Effect on Local Tumor Control in Young Women With Breast Cancer

Purpose: To evaluate the local control rate and complications of a single fraction of high-dose-rate brachytherapy (HDR BT) boost in women aged 45 yeas and younger after breast-conserving therapy. Methods and Materials: Between 1999 and 2007, 167 patients between the ages of 26 and 45 years old (72 were 40 years old or younger), with stages T1 to T2 invasive breast cancer with disease-free margin status of at least 5 mm after breast-conserving surgery received 46 to 50 Gy whole-breast irradiation plus a 7-Gy HDR-BT boost (“fast boost”). An axillary dissection was performed in 72.5% of the patients and sentinel lymph node biopsy in 27.5%. A supraclavicular area was irradiated in 19% of the patients. Chemotherapy was used in 86% of the patients and hormone treatment in 77%. Clinical nodes were present in 18% and pathological nodes in 29%. The pathological stage was pT0: 5%, pTis: 3%, pT1: 69% and pT2: 23%. Intraductal component was present in 40% and 28% were G3. Results: At a median follow-up of 92 months, 9 patients relapsed on the margin of the implant, and 1 patient in another quadrant, resulting in a 10-year local relapse rate of 4.3% and a breast relapse rate of 4.9%, with breast preservation in 93.4%; no case of mastectomy due to poor cosmesis arose. Actuarial 5- and 10-year disease-free, cause-specific, and overall survival rates were 87.9% and 85.8%, and 92.1% and 88.4%, and 92.1% and 87.3%, respectively. In a univariate analysis, triple-negative cases and negative hormone receptors did worse, but in a multivariate analysis, only the last factor was significant for local and breast control. Asymptomatic fibrosis G2 was recorded in 3 cases, and there were no other late complications. Cosmetic results were good to excellent in 97% of cases. Conclusions: A single dose of 7 Gy using the fast-boost technique is well tolerated, with a low rate of late complications and improved local tumor control in women aged 45 and younger, compared to published data. This approach is recommended in breast-preserving treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Swarm Intelligence Based Optimal Design of Local Volt/Var Control Function for Distributed Energy Resources

The increasing penetration of renewable based distributed energy resources (DERs) in distribution network (DN) leads to larger and more frequent voltage variation in distributions network (DN), thus posing challenges on voltage control. Real-time local voltage control method is a promising solution for the above issue. However, the local voltage control function needs to be customized and optimized according to real distribution system condition. In this paper, a swarm intelligence based Volt/Var control optimal design method (SO-VVC) is proposed to optimize the control function. Compared with existing approaches, the proposed method can not only represent the nonlinear behaviour of power flow but is also computation efficient. The performance of the proposed SO-VVC is demonstrated by case studies on a modified IEEE-123 bus system.

Zhang, Zhengfa [University of Tennessee, Knoxville↗

Influence of Smoking and Alcohol Drinking Behaviors on Treatment Outcomes of Patients With Squamous Cell Carcinomas of the Head and Neck

Purpose: To retrospectively evaluate the prognostic value of smoking and drinking status in patients with head-and-neck squamous cell carcinomas. Methods and Materials: All patients with all stages and sites were included if complete information was available on baseline smoking and alcohol behavior (never, former, active), disease stage, primary site, radiation dose, sex, and age. Treatment was radiotherapy in 973 patients, postoperative radiotherapy in 469, and chemoradiotherapy in 429. Statistical analysis was performed with Kaplan-Meier and Cox methods. Results: Data from 1,871 patients were available. At baseline, 9% of patients never smoked, 40% were former smokers, and 51% were active smokers; 20% never drank, 25% were former drinkers, and 55% were active drinkers. Smoking was associated with inferior local control and survival. For local control, the hazard ratio (HR) of active smokers vs. former smokers was 1.5 (p = 0.0001). For survival, the HRs of former smokers and active smokers vs. those who never smoked were also statistically significant (1.3 and 1.7, respectively, p = 0.000001). Alcohol drinking was associated with local control (p = 0.03), and was associated with survival. For survival, HRs of former and active drinkers compared with those who never drank were, respectively, 1.1 (p = 0.01) and 1.28 (p = 0.001). Adjusted 5-year local control and survival rates for those who never smoked and never drank were 87% and 77%, respectively, and for those who were both active smokers and active drinkers were 72% (p = 0.007) and 52% (p = 0.0009), respectively. Conclusion: Smoking and drinking at baseline were associated with poor outcomes in these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prevalence and scalable control of localized networks

The ability to control network dynamics is essential for ensuring desirable functionality of many technological, biological, and social systems. Such systems often consist of a large number of network elements, and controlling large-scale networks remains challenging because the computation and communication requirements increase prohibitively fast with network size. Here, we introduce a notion of network locality that can be exploited to make the control of networks scalable, even when the dynamics are nonlinear. We show that network locality is captured by an information metric and is almost universally observed across real and model networks. In localized networks, the optimal control actions and system responses are both shown to be necessarily concentrated in small neighborhoods induced by the information metric. This allows us to develop localized algorithms for determining network controllability and optimizing the placement of driver nodes. This also allows us to develop a localized algorithm for designing local feedback controllers that approach the performance of the corresponding best global controllers, while incurring a computational cost orders-of-magnitude lower. Here, we validate the locality, performance, and efficiency of the algorithms in Kuramoto oscillator networks, as well as three large empirical networks: synchronization dynamics in the Eastern US power grid, epidemic spreading mediated by the global air-transportation network, and Alzheimer’s disease dynamics in a human brain network. Taken together, our results establish that large networks can be controlled with computation and communication costs comparable to those for small networks.

42 ENGINEERING↗

Learning Provably Stable Local Volt/Var Controllers for Efficient Network Operation

Here this paper develops a data-driven framework to synthesize local Volt/Var control strategies for distributed energy resources (DERs) in power distribution grids (DGs). Aiming to improve DG operational efficiency, as quantified by a generic optimal reactive power flow (ORPF) problem, we propose a two-stage approach. The first stage involves learning the manifold of optimal operating points determined by an ORPF instance. To synthesize local Volt/Var controllers, the learning task is partitioned into learning local surrogates (one per DER) of the optimal manifold with voltage input and reactive power output. Since these surrogates characterize efficient DG operating points, in the second stage, we develop local control schemes that steer the DG to these operating points. We identify the conditions on the surrogates and control parameters to ensure that the locally acting controllers collectively converge, in a global asymptotic sense, to a DG operating point agreeing with the local surrogates. We use neural networks to model the surrogates and enforce the identified conditions in the training phase. AC power flow simulations on the IEEE 37-bus network empirically bolster the theoretical stability guarantees obtained under linearized power flow assumptions. The tests further highlight the optimality improvement compared to prevalent benchmark methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗