Search NASA⌕ Search

SEARCH · Search NASA

Results for “long term testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A highly scalable spray coating technique for electrode infiltration: Barium carbonate infiltrated La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ perovskite structured electrocatalyst with demonstrated long term durability

Barium carbonate (BaCO 3 ) nanoparticles have demonstrated excellent catalytic activity for the oxygen reduction reaction by spray coating onto La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ (LSCF) and LSCF-SDC (Sm 0.2 Ce 0.8 O 2-δ ) cathode materials. In this work, barium acetate solutions were modified by a surfactant to lower the surface tension and decrease the contact angle on LSCF which is a benefit for the infiltration process. In the LSCF electrode, BaCO 3 nano-particles exhibited significant interfacial contact with LSCF particles by the spray coating technique. As a result, the polarization resistance of BaCO 3 infiltrated LSCF was reduced from 2.5 to 1.2 Ωcm 2 at 700 °C. In addition, commercial full cell SOFCs with BaCO 3 infiltrated LSCF-SDC cathodes also demonstrated higher performance due to the reduced cathode resistance. At 750 °C, the electrode overpotential of the BaCO3 infiltrated cell was much lower than that of baseline cell during long term testing (500 hours). The polarization resistance of the BaCO 3 infiltrated LSCF-SDC electrode only increased by 1.6% after 500 hours. This work demonstrated a highly scalable spray coating process of a promising electrocatalyst (BaCO 3 ) with excellent long-term stability for the oxygen reduction reaction.

42 ENGINEERING↗

Dehumidification via membrane separation for space-based applications

The paper describes the development of a membrane-based dehumidification process for space-based applications, such as spacecraft cabins and EVA space suits. Results presented are from: (1) screening tests conducted to determine the efficacy of various membranes to separate water vapor from air, and (2) parametric and long-term tests of membranes operated at conditions that simulate the range of environmental conditions (e.g., temperature and relative humidity) expected in the planned Space Station. Also included in this paper is a discussion of preliminary designs of membrane-based dehumidification processes for the Space Station and EVA space suits. These designs result in compact and energy-efficient systems that offer significant advantages over conventional dehumidification processes.

Gienger, Jane Kucera↗

DEGRADATION IN PERFORMANCE OF LANTHANUM STRONTIUM MANGANITE BASED SOLID OXIDE FUEL CELL CATHODES UNDER ACCELERATED TESTING

The performance of solid oxide fuel cells (SOFCs) with three different lanthanum strontium manganite (LSM) based cathode compositions were evaluated. All cells were yttria-stabilized zirconia (Zr0.92Y0.08O2-δ, 8YSZ) electrolyte-supported button cells, consisting of a nickel oxide – yttria-stabilized zirconia (NiO-8YSZ) anode and a cathode of 8YSZ and LSM. The three LSM compositions differed in the amount of excess Mn: Composition A was (La0.85Sr0.15)0.90MnO3±δ (10% excess Mn); Composition B was (La0.80Sr0.20)0.95MnO3±δ (5% excess Mn); and Composition C was (La0.80Sr0.20)0.98MnO3±δ (2% excess Mn). The cells were tested under conventional and accelerated conditions, where the accelerated conditions were meant to simulate the results of months of long-term testing in just 500 hours (approximately three weeks) of testing by using high operating temperature and current density. Accelerated tests showed lower degradation rates, lower continuous area specific resistance (ASR), and higher power output than conventional tests for all cathode compositions. Continuous measurements of the cells' output voltage versus time, together with periodic electrochemical impedance spectroscopy (EIS) measurements, were used to evaluate the performance of the cells in terms of ASR degradation rates (% ASR rise per kh) and power outputs. The EIS measurements also permitted a partial deconvolution of the cathode ASR from the anode ASR. Cathodes with 10% excess Mn tested under accelerated conditions had the lowest degradation rates, but the highest continuous ASR and lowest power outputs. Cathodes with 2% excess Mn tested under accelerated conditions had the lowest continuous ASR and highest power outputs; thus it was concluded that cells with the lowest amount of excess Mn cathodes performed the best.

08 HYDROGEN↗

Experimental design, operation, and results of a 4 kW high temperature steam electrolysis experiment

High temperature steam electrolysis (HTSE) is a promising technology for large-scale hydrogen production. However, research on HTSE performance above the kW level is limited. This paper presents the results of 4 kW HTSE long-term test completed in a multi-kW test facility recently developed at the Idaho National Laboratory (INL). The 4 kW HTSE unit included two solid oxide electrolysis stacks operating in parallel, each of which included 40 electrode-supported planar cells. A current density of 0.41 A/cm2 was used for the long-term operation, resulting in a hydrogen production rate about 25 slpm. A demonstration of 920 hours stable operation was achieved. The paper also includes detailed descriptions of the piping layout, steam generation and delivery system, test fixture, heat recuperation system, hot zone, instrumentation, and operating conditions. As a result, this successful demonstration of multi-kW scale HTSE unit will help to advance the technology toward near-term commercialization.

08 HYDROGEN↗

Near-field measurement facility plans at Lewis Research Center

The direction of future antenna technology will be toward antennas which are large, both physically and electrically, will operate at frequencies up to 60 GHz, and are non-reciprocal and complex, implementing multiple-beam and scanning beam concepts and monolithic semiconductor devices and techniques. The acquisition of accurate antenna performance measurements is a critical part of the advanced antenna research program and represents a substantial antenna measurement technology challenge, considering the special characteristics of future spacecraft communications antennas. Comparison of various antenna testing techniques and their relative advantages and disadvantages shows that the near-field approach is necessary to meet immediate and long-term testing requirements. The LeRC facilities, the 22 ft x 22 ft horizontal antenna boresight planar scanner and the 60 ft x 60 ft vertical antenna boresight plant scanner (with a 60 GHz frequency and D/lamdba = 3000 electrical size capabilities), will meet future program testing requirements.

Sharp, R. G.↗

Development and characterization of the Capillary DirectINJECT System

The DirectINJECT Project was initiated to create a reliable in-line dosing system for delivering a concentrated silver ion biocide solution into spacecraft potable water. Three dosing systems, including a miniature peristaltic pump, a multi-piston pump, and a differential pressure-driven capillary tube, were quickly prototyped and tested. Although the peristaltic and multi-piston pump systems met the desired flow rate range, the capillary system showed the most promise and was chosen for further development. In FY23, the Capillary DirectINJECT dosing system underwent extensive testing with a nominal injection rate of 1.0 μl/min into varying backpressure conditions. A Primary DirectINJECT System with triplicate testbeds was employed for long-term testing, and auxiliary systems like the Secondary DirectINJECT System and Leak Testbed were developed to characterize specific components and investigate various phenomena related to the dosing system. Parameters such as flow rates, reservoir pressures, and temperature were monitored throughout the testing campaigns.

DirectINJECT↗

Significance of metastable acceptors in Cu(In,Ga)Se 2 solar cells in accelerated lifetime testing

The significance of metastable acceptors in Cu(In,Ga)Se 2 (CIGS) solar cells in accelerated lifetime testing has been investigated. Dry heating under light irradiation improves the conversion efficiency of CIGS solar cells at the early stage, which slightly decreases after long-term testing. However, after dry heating in the dark, the conversion efficiency significantly decreases. The net acceptor concentration considerably decreases after dark heating, and the reduction in the number of metastable acceptors results in decreases in open-circuit voltage and fill factor. After heat illumination treatment, the net acceptor concentration increases because of the metastable acceptors in CIGS layers, and the open-circuit voltage and fill factor partly recover. Therefore, the concentrations of metastable acceptors should be controlled by light irradiation or current injection with positive bias to evaluate correctly the degradation rates during accelerated lifetime testing.

14 SOLAR ENERGY↗

Develop and test fuel cell powered on-site integrated total energy systems. Phase 3: Full-scale power plant development

The testing of two 25-cell stacks of the 13 inch x 23 inch cell size (about 4kW) was carried out for 7000 and 8400 hours, respectively. A 25kW stack containing 175 cells of the same size and based on the same technology was constructed and is on test. A third 4kW stack, which will contain 24 cells, will comprise several new technology features; these will be assesed for performance and durability in long-term testing.

Kaufman, A.↗

A Synergistic Combination of Advanced Separation and Chemical Scale Inhibitor Technologies for Efficient Use of Imparied Water As Cooling Water in Coal-based Power Plants

Nalco Company is partnering with Argonne National Laboratory (ANL) in this project to jointly develop advanced scale control technologies that will provide cost-effective solutions for coal-based power plants to operate recirculating cooling water systems at high cycles using impaired waters. The overall approach is to use combinations of novel membrane separations and scale inhibitor technologies that will work synergistically, with membrane separations reducing the scaling potential of the cooling water and scale inhibitors extending the safe operating range of the cooling water system. The project started on March 31, 2006 and ended in August 30, 2010. The project was a multiyear, multi-phase project with laboratory research and development as well as a small pilot-scale field demonstration. In Phase 1 (Technical Targets and Proof of Concept), the objectives were to establish quantitative technical targets and develop calcite and silica scale inhibitor chemistries for high stress conditions. Additional Phase I work included bench-scale testing to determine the feasibility of two membrane separation technologies (electrodialysis ED and electrode-ionization EDI) for scale minimization. In Phase 2 (Technology Development and Integration), the objectives were to develop additional novel scale inhibitor chemistries, develop selected separation processes, and optimize the integration of the technology components at the laboratory scale. Phase 3 (Technology Validation) validated the integrated system's performance with a pilot-scale demonstration. During Phase 1, Initial evaluations of impaired water characteristics focused on produced waters and reclaimed municipal wastewater effluents. Literature and new data were collected and evaluated. Characteristics of produced waters vary significantly from one site to another, whereas reclaimed municipal wastewater effluents have relatively more uniform characteristics. Assessment to date confirmed that calcite and silica/silicate are two common potential cycle-limiting minerals for using impaired waters. For produced waters, barium sulfate and calcium sulfate are two additional potential cycle-limiting minerals. For reclaimed municipal wastewater effluents, calcium phosphate scaling can be an issue, especially in the co-presence of high silica. Computational assessment, using a vast amount of Nalco's field data from coal fired power plants, showed that the limited use and reuse of impaired waters is due to the formation of deposit caused by the presence of iron, high hardness, high silica and high alkalinity in the water. Appropriate and cost-effective inhibitors were identified and developed - LL99B0 for calcite and gypsum inhibition and TX-15060 for silica inhibition. Nalco's existing dispersants HSP-1 and HSP-2 has excellent efficacy for dispersing Fe and Mn. ED and EDI were bench-scale tested by the CRADA partner Argonne National Laboratory for hardness, alkalinity and silica removal from synthetic make-up water and then cycled cooling water. Both systems showed low power consumption and 98-99% salt removal, however, the EDI system required 25-30% less power for silica removal. For Phase 2, the EDI system's performance was optimized and the length of time between clean-in-place (CIP) increased by varying the wafer composition and membrane configuration. The enhanced EDI system could remove 88% of the hardness and 99% of the alkalinity with a processing flux of 19.2 gal/hr/m{sup 2} and a power consumption of 0.54 kWh/100 gal water. Bench tests to screen alternative silica/silicate scale inhibitor chemistries have begun. The silica/silicate control approaches using chemical inhibitors include inhibition of silicic acid polymerization and dispersion of silica/silicate crystals. Tests were conducted with an initial silica concentration of 290-300 mg/L as SiO{sub 2} at pH 7 and room temperature. A proprietary new chemistry was found to be promising, compared with a current commercial product commonly used for silica/silicate control. Additional pilot cooling tower testing confirmed the bench study. We also developed a molecule to inhibit calcium carbonate precipitation and calcium sulfate precipitation at high supersaturations. During Phase 3, a long-term test of the EDI system and scale inhibitors was done at Nalco's cooling tower water testing facility, producing 850 gallons of high purity water (90+% salt removal) at a rate of 220 L/day. The EDI system's performance was stable when the salt concentration in the concentrate compartment (i.e. the EDI waste stream) was controlled and a CIP was done after every 48 hours of operation time. A combination of EDI and scale inhibitors completely eliminated blowdown discharge from the Pilot cooling Tower. The only water-consumption came from evaporation, CIP and EDI concentrate. Silica Inhibitor was evaluated in the field at a western coal fired power plant.

01 COAL, LIGNITE, AND PEAT↗

Lunar base - A stepping stone to Mars

Basic elements of technology and programmatic development are identified that appear relevant to the Case for Mars, starting from a base on the moon. The moon is a logical stepping stone toward human exploration of Mars because a lunar base can provide the first test of human ability to use the resources of another planetary body to provide basic materials for life support. A lunar base can provide the first long-term test of human capability to work and live in a reduced (but not zero) gravity field. A lunar base requires creation of the elements of a space transportation system that will be necessary to deliver large payloads to Mars and the space operations capability and experience necessary to carry out a Mars habitation program efficiently and with high reliability. A lunar base is feasible for the first decade of the 21st Century. Scenarios have been studied that provide advanced capability by 2015 within budget levels that are less than historical U.S. space expenditures (Apollo). Early return on the investment in terms of knowledge, practical experience and lunar products are important in gaining momentum for an expanded human exploration of the solar system and the eventual colonization of Mars.

Duke, M. B.↗

Designing and Validating Ternary Pd Alloys for Optimum Sulfur/Carbon Resistance in Hydrogen Separation and Carbon Capture Membrane Systems Using High-Throughput Combinatorial Methods

This report summarizes the work completed under the U.S. Department of Energy Project Award No.: DE-FE0001181 titled “Designing and Validating Ternary Pd Alloys for Optimum Sulfur/Carbon Resistance in Hydrogen Separation and Carbon Capture Membrane Systems Using High-Throughput Combinatorial Methods.” The project started in October 1, 2009 and was finished September 30, 2014. Pall Corporation worked with Cornell University to sputter and test palladium-based ternary alloys onto silicon wafers to examine many alloys at once. With the specialized equipment at Georgia Institute of Technology that analyzed the wafers for adsorbed carbon and sulfur species six compositions were identified to have resistance to carbon and sulfur species. These compositions were deposited on Pall AccuSep® supports by Colorado School of Mines and then tested in simulated synthetic coal gas at the Pall Corporation. Two of the six alloys were chosen for further investigations based on their performance. Alloy reproducibility and long-term testing of PdAuAg and PdZrAu provided insight to the ability to manufacture these compositions for testing. PdAuAg is the most promising alloy found in this work based on the fabrication reproducibility and resistance to carbon and sulfur. Although PdZrAu had great initial resistance to carbon and sulfur species, the alloy composition has a very narrow range that hindered testing reproducibility.

36 MATERIALS SCIENCE↗

Potential utilization of the NASA/George C. Marshall Space Flight Center in earthquake engineering research

Earthquake engineering research capabilities of the National Aeronautics and Space Administration (NASA) facilities at George C. Marshall Space Flight Center (MSFC), Alabama, were evaluated. The results indicate that the NASA/MSFC facilities and supporting capabilities offer unique opportunities for conducting earthquake engineering research. Specific features that are particularly attractive for large scale static and dynamic testing of natural and man-made structures include the following: large physical dimensions of buildings and test bays; high loading capacity; wide range and large number of test equipment and instrumentation devices; multichannel data acquisition and processing systems; technical expertise for conducting large-scale static and dynamic testing; sophisticated techniques for systems dynamics analysis, simulation, and control; and capability for managing large-size and technologically complex programs. Potential uses of the facilities for near and long term test programs to supplement current earthquake research activities are suggested.

Scholl, R. E.↗

Upscaling of asymmetric hollow fiber‐supported thin film membranes for oxygen separation from air: Proof of concept

Abstract Hollow fiber membranes demonstrate various advantages for high performance oxygen separation. However, the small diameters of hollow fibers and the brittleness of ceramics limit their mechanical strength, imposing great difficulties on stack and module development. Gas‐tight sealing is another challenge for upscaling of hollow fiber membrane technology. Low temperature sealant materials of epoxy resin or silicon are typically used for hollow fiber stacks, requiring that the sealing portions be located out of hot zone. Consequently, only partial length of hollow fibers participates in oxygen permeation. In this study, upscaling of our recently developed asymmetric hollow fiber‐supported thin film membranes is conducted, where individual hollow fibers are assembled in parallel to form a stack. A reliable gas‐tight sealing is obtained by combining ceramic paste with conductive adhesive ink cohesively. Comprehensive oxygen permeation test is conducted with the sealing portions being in hot zone and compared with a single hollow fiber membrane. Fundamental mechanism is discussed to understand the performances and their differences. An accelerated long‐term test (∼320 h, 16 thermal cycles) demonstrates excellent stability and robustness of the stack and sealing. The characterization of post‐test samples further confirms excellent stability and robustness of the phases and microstructures of the stack.

36 MATERIALS SCIENCE↗

Microstructural and Material Quality Effects on Rolling Contact Fatigue of Highly Elastic Intermetallic Ball Bearings

Rolling element bearings made from highly-elastic intermetallic materials (HIM)s, such as 60NiTi, are under development for applications that require superior corrosion and shock resistance. Compared to steel, intermetallics have been shown to have much lower rolling contact fatigue (RCF) stress capability in simplified 3-ball on rod (ASTM STP 771) fatigue tests. In the 3-ball tests, poor material quality and microstructural flaws negatively affect fatigue life but such relationships have not been established for full-scale 60NiTi bearings. In this paper, 3-ball-on-rod fatigue behavior of two quality grades of 60NiTi are compared to the fatigue life of full-scale 50mm bore ball bearings made from the same materials. 60NiTi RCF rods with material or microstructural flaws suffered from infant mortality failures at all tested stress levels while high quality 60NiTi rods exhibited no failures at lower stress levels. Similarly, tests of full-scale bearings made from flawed materials exhibited early surface fatigue and through crack type failures while bearings made from high quality material did not fail even in long-term tests. Though the full-scale bearing test data is yet preliminary, the results suggest that the simplified RCF test is a good qualitative predictor of bearing performance. These results provide guidance for materials development and to establish minimum quality levels required for successful bearing operation and life.

tribology↗

Microstructural and Material Quality Effects on Rolling Contact Fatigue of Highly Elastic Intermetallic NiTi Ball Bearings

Rolling element bearings made from highly-elastic intermetallic materials (HIM)s, such as 60NiTi, are under development for applications that require superior corrosion and shock resistance. Compared to steel, intermetallics have been shown to have much lower rolling contact fatigue (RCF) stress capability in simplified 3-ball on rod (ASTM STP 771) fatigue tests. In the 3-ball tests, poor material quality and microstructural flaws negatively affect fatigue life but such relationships have not been established for full-scale 60NiTi bearings. In this paper, 3-ball-on-rod fatigue behavior of two quality grades of 60NiTi are compared to the fatigue life of full-scale 50mm bore ball bearings made from the same materials. 60NiTi RCF rods with material or microstructural flaws suffered from infant mortality failures at all tested stress levels while high quality 60NiTi rods exhibited no failures at lower stress levels. Similarly, tests of full-scale bearings made from flawed materials exhibited early surface fatigue and through crack type failures while bearings made from high quality material did not fail even in long-term tests. Though the full-scale bearing test data is yet preliminary, the results suggest that the simplified RCF test is a good qualitative predictor of bearing performance. These results provide guidance for materials development and to establish minimum quality levels required for successful bearing operation and life.

metals↗

Development of a Thin Film Primary Surface Heat Exchanger for Advanced Power Cycles

This project objective is to develop a high-temperature design upgrade for an existing primary surface heat exchanger so that the redesigned hardware is capable of operation in CO 2 at temperatures up to 1,510°F (821°C) and pressure differentials up to 130 psi (9 bar). The heat exchanger is proposed for use as a recuperator in an advanced low-pressure oxy-fuel Brayton cycle that is predicted to achieve over 50% thermodynamic efficiency, although the heat exchanger could also be used in other high-temperature, low-differential pressure cycles. This report describes the progress to date, which includes continuing work performed to select and test new candidate materials for the recuperator redesign, final mechanical and thermal performance analysis results of various redesign concepts, and the preliminary design of a test loop for the redesigned recuperator including a budgetary estimate for detailed test loop design, procurement, and test operation. A materials search was performed in order to investigate high-temperature properties of many candidate materials, including high-temperature strength and nickel content. These properties were used to rank the candidate materials, resulting in a reduced list of nine materials for corrosion testing. Multiple test rigs were considered and analyzed for short-term corrosion testing and Thermal Gravimetric Analysis (TGA) was selected as the most cost-effective option for evaluating corrosion resistance of the candidate materials. In addition, tantalum, niobium, and chromium coatings were identified as potential options for increased corrosion resistance. The test results show that many materials exhibit relatively low weight gain rates, and that niobium and tantalum coatings may improve corrosion resistance for many materials, while chromium coatings appear to oxidize and debond quickly. Metallurgical analysis of alloys was also performed, showing evidence of intergranular attack in 282 that may cause long-term reliability problems in CO 2 service at these temperatures. However, long-term testing in a flowing environment is recommended in order to understand accurately the severity of the attack. Detailed economic modeling of the existing air cycle recuperator and CO 2 cycle recuperator options was also completed, including costs for material, fabrication, fuel, maintenance, and operation. The analysis results show that the increased capital cost for high-temperature materials may be offset by higher cycle efficiencies, decreasing the overall lifetime cost of the system. The economic analysis also examines costs associated with increased pressure drop and material changes for two redesign options. These results show that, even with slightly reduced performance and/or higher material costs, the lifetime cost per energy production may still be reduced by over 12%. The existing recuperator design information was provided by Solar Turbines, Inc. via several models, drawings, and design handoff meetings. Multiple fluid/thermal and structural models were created in order to analyze critical recuperator performance and mechanical strength in critical areas throughout the redesign process. These models were analyzed for a baseline condition (consistent with current Mercury 50 operation) for validation purposes. Results are presented for heat transfer coefficients and pressure drops, matching well with the existing operational data. Simulation of higher-temperature CO 2 conditions was also performed, showing a slight expected increase in both heat transfer and pressure drop. Mechanical analysis results for critical areas on the cross-flow and counter-flow sheets have also been obtained for air and CO 2 cases. These results show similar stresses in both cases but significantly reduced safety factors for the CO 2 case due to reduced yield and creep rupture strengths of alloy 625 at the higher temperatures. A concept brainstorm session and initial down-selection were completed in order to identify promising redesign options for further analysis. Detailed analysis of all promising redesign options was performed via finite element and computational fluid dynamic simulations in order to characterize mechanical and thermal-fluid performance of each option. These options included material change, various sheet thickness configurations, pitch and phasing of cross-flow and counter-flow sheets, and separator sheets. The analysis results have identified two viable redesign options that maintain existing safety margins optimally through a material change to Haynes 282 and (A) sheet thickness increases of 40% on the counter-flow sheet and 75% on the hot side cross-flow corrugation sheet or (B) addition of a separator sheet in the counter-flow section while maintaining the original counter-flow sheet thickness and increasing the cross-flow corrugation sheet thickness by 90% to account for the increase in cell height. While both options satisfy mechanical stress constraints, the separator sheet design has a higher part count, slightly reduced heat transfer, and slightly higher pressure drop than the first option and is not preferred. Finally, several test loop concepts have been developed for different full-scale and reduced-scale recuperator testing options. For each option, various loop components, such as heat exchangers, valves, heaters, and compressors, were evaluated in an effort to maximize utilization of existing resources. All concepts utilize an existing 3-MW CO 2 compressor, heater, and loop coolers, but the concepts vary by incorporating different amounts of new equipment for achieving various flow rates (all concepts operate at design pressure and temperature). The third concept achieves a 1 kg/s test without purchasing any costly equipment (coolers, heaters, blowers, etc.). Since the stacked cell design of the recuperator results in the same flow conditions at each core cell (even for a reduced-scale test). Thus, test loop Concept #3 was selected for the preliminary design. This loop design is detailed within the report, culminating in a budgetary estimate of $1,013,000.00 for the detailed design, construction, commissioning, and operation of a high-temperature recuperator test loop.

03 NATURAL GAS↗

Space Flight Requirements for Fiber Optic Components; Qualification Testing and Lessons Learned

"Qualification" of fiber optic components holds a very different meaning than it did ten years ago. In the past, qualification meant extensive prolonged testing and screening that led to a programmatic method of reliability assurance. For space flight programs today, the combination of using higher performance commercial technology, with shorter development schedules and tighter mission budgets makes long term testing and reliability characterization unfeasible. In many cases space flight missions will be using technology within years of its development and an example of this is fiber laser technology. Although the technology itself is not a new product the components that comprise a fiber laser system change frequently as processes and packaging changes occur. Once a process or the materials for manufacturing a component change, even the data that existed on its predecessor can no longer provide assurance on the newer version. In order to assure reliability during a space flight mission, the component engineer must understand the requirements of the space flight environment as well as the physics of failure of the components themselves. This can be incorporated into an efficient and effective testing plan that "qualifies" a component to specific criteria defined by the program given the mission requirements and the component limitations. This requires interaction at the very initial stages of design between the system design engineer, mechanical engineer, subsystem engineer and the component hardware engineer. Although this is the desired interaction what typically occurs is that the subsystem engineer asks the components or development engineers to meet difficult requirements without knowledge of the current industry situation or the lack of qualification data. This is then passed on to the vendor who can provide little help with such a harsh set of requirements due to high cost of testing for space flight environments. This presentation is designed to guide the engineers of design, development and components, and vendors of commercial components with how to make an efficient and effective qualification test plan with some basic generic information about many space flight requirements. Issues related to the ~ physics of failure, acceptance criteria and lessons learned will also be discussed to assist with understanding how to approach a space flight mission in an ever changing commercial photonics industry.

Ott, Melanie N.↗