Search NASA⌕ Search

SEARCH · Search NASA

Results for “low noise temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Spontaneous Raman–LIF–CO–OH measurements of species concentration in turbulent spray flames

This paper presents new measurements of species concentrations, temperature and mixture fraction in selected regions of a turbulent ethanol spray flame. The line-Raman–LIF–COsingle bondOH setup developed at the Sandia's Combustion Research Facility is utilised to probe regions of a spray flame where laser breakdown of liquid droplets is avoided and the remaining interferences can be corrected. The spray flame is stabilised on the piloted Sydney needle spray burner, where axial translation of the liquid injecting needle in the air-blast stream can transition the spray from dilute to dense. The solution to obtaining successful measurements is found to be multifaceted and includes: the appropriate selection of flame conditions; high sensitivity of the Raman detection system permitting reduced laser energies; development of a pre-processing algorithm to reject strong droplet interferences; and application of the hybrid matrix inversion method combined with wavelet denoising to account for interference corrections and noise at the very low signal levels obtained. Unique and necessary for the successful measurements reported in this paper, a pre-processing algorithm is outlined that removes data points corrupted with strong interferences from droplets. These interferences arise from a range of sources, but the most intense are due to the laser interaction with surrounding mist or liquid fragments, such that measurements near the jet centreline are corrupted and hence discarded. Reliable measurements of mixture fraction, temperature obtained from the sum of the species number densities, and species mole fractions are reported for regions in the flames sufficiently far from the centreline. The paper demonstrates the feasibility of the judicious use of Raman scattering in turbulent spray flames, the results of which will be extremely useful for validating numerical simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-line, High-Throughput Quality Monitoring for Fuel Cell and Electrolyzer Components Based on Transmission and Reflection Imaging

During the manufacturing of fuel cell and electrolyzer membranes and membrane electrode assemblies (MEAs), real-time, in-line, high-throughput optical-based quality monitoring methods are essential for detecting defects and monitoring thickness variations, thus improving the performance and increasing the durability of fuel cell and electrolyzer in the hydrogen industry. For the MEAs with very opaque coatings, optical transmission-based imaging has been developed and applied in the Roll-to-Roll system using a flashlight and a high-sensitivity CCD camera. We observed high signal-to-noise ratio images while the Roll-to-Roll system ran at 5 ft/min. The entire sample image could quickly be recovered from the discrete frames using customized Python codes for automatic frame cropping and stitching. We detected significant non-uniformities in our experimental MEAs specimen. For fuel cell and low-temperature electrolysis (LTE) transparent membranes, we used optical reflectance hyperspectral imaging with interference fringe-based thickness mapping. We set up a hyperspectral camera to measure various rolls of commercial membranes. The measurement results are analyzed to find the thickness distribution of each roll and to check for defects. Transmission and reflection imaging-based quality monitoring techniques demonstrated in this project can be widely used in the mass production environment to improve the production yield and performance of hydrogen devices.

DIRECT ENERGY CONVERSION,ENGINEERING↗

Millimeter-Wave Superconducting Qubit

Manipulating the electromagnetic spectrum at the single-photon level is fundamental for quantum experiments. In the visible and infrared ranges, this can be accomplished with atomic quantum emitters, and with superconducting qubits such control is extended to the microwave range (below 10 GHz). Meanwhile, the region between these two energy ranges presents an unexplored opportunity for innovation. We bridge this gap by scaling up a superconducting qubit to the millimeter-wave range (near 100 GHz). Working in this energy range greatly reduces sensitivity to thermal noise compared to microwave devices, enabling operation at significantly higher temperatures, up to 1 K. This has many advantages by removing the dependence on rare 3⁢ He for refrigeration, simplifying cryogenic systems, and providing orders-of-magnitude higher cooling power, lending the flexibility needed for novel quantum sensing and hybrid experiments. Using low-loss niobium trilayer junctions, we realize a qubit at 72 GHz cooled to 0.87 K using only 4 ⁢He. We perform Rabi oscillations to establish control over the qubit state, and measure relaxation and dephasing times of 15.8 and 17.4 ns, respectively. This demonstration of a millimeter-wave quantum emitter offers exciting prospects for enhanced sensitivity thresholds in high-frequency photon detection, provides new options for quantum transduction and for scaling up and speeding up quantum computing, enables integration of quantum systems where 3 ⁢He refrigeration units are impractical, and, importantly, paves the way for quantum experiments exploring a novel energy range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Expected sensitivity to 128 Te neutrinoless double beta decay with the CUORE TeO 2 cryogenic bolometers

The CUORE experiment is a ton-scale array of TeO 2 cryogenic bolometers located at the underground Laboratori Nazionali del Gran Sasso of Istituto Nazionale di Fisica Nucleare (INFN), in Italy. The CUORE detector consists of 988 crystals operated as source and detector at a base temperature of ~ 10 mK. Such cryogenic temperature is reached and maintained by means of a custom built cryogen-free dilution cryostat, designed with the aim of minimizing the vibrational noise and the environmental radioactivity. The primary goal of CUORE is the search for neutrinoless double beta decay of 130 Te , but thanks to its large target mass and ultra-low background it is suitable for the study of other rare processes as well, such as the neutrinoless double beta decay of 128 Te. This tellurium isotope is an attractive candidate for the search of this process, due to its high natural isotopic abundance of 31.75%. The transition energy at (866.7 ± 0.7) keV lies in a highly populated region of the energy spectrum, dominated by the contribution of the two-neutrino double beta decay of 130 Te. As the first ton-scale infrastructure operating cryogenic TeO 2 bolometers in stable conditions, CUORE is able to achieve a factor > 10 higher sensitivity to the neutrinoless double beta decay of this isotope with respect to past direct experiments.

128-Te↗

Application of helium line intensity ratio spectroscopy to xenon plasma in E × B Penning discharge

Here, we propose the application of helium line intensity ratio spectroscopy in a low-pressure (0.3 mTorr) xenon E × B discharge with an electron temperature of ~2 eV and a density of 10 10 –10 11 cm –3 . We successfully identified the helium atom line emissions at 388.9, 447.1, 501.6, 504.8, and 706.5 nm with helium pressures of up to ~20 mTorr. The measured electron temperature, density, and I–V characteristics of the discharge remained almost constant in all helium pressures in the present experiment, indicating the suitability of the helium gas as a diagnostic gas. The results of helium line intensity ratio spectroscopy using the line emissions at 388.9, 447.1, and 504.8 nm showed fair agreement with the Langmuir probe measurement. Considering the trade-off relationship between the disturbance introduced by the helium gas and the signal-to-noise ratio, we conclude that a helium pressure of approximately 4 mTorr (approximately 13 times the partial pressure of xenon) represents the optimal pressure range for the application of the helium line emission intensity ratio method to this xenon plasma. It is found that the use of the line emissions at 501.6 and 706.5 nm result in a significant disturbance in the helium line intensity ratio method due to the radiation trapping effect.

helium line intensity ratio spectroscopy↗

SQUID Readout of a High-$Q$ Superconducting $LC$ Resonator

We demonstrate the readout of a superconducting $LC$ resonator, with $Q \approx 2 \times 10^{6}$ at approximately 250 kHz, using a dc SQUID followed by a SQUID series-array amplifier readout chain. We find that $Q$ depends on the SQUID flux-bias point, increasing near the shallow-slope point of the SQUID modulation curve and decreasing near the steep-slope point, consistent with the previously observed SQUID damping effects. From this variation, we infer the SQUID effective input impedance. We further infer the effective temperature of the resonator circuit from the resonance peak in the noise spectrum and show that it also depends on the SQUID flux-bias point, suggesting a possible contribution from SQUID back-action noise. This system provides a working prototype for future experiments based on lumped-element resonators with SQUID readout, in particular low-mass axion searches within the DMRadio program.

FOS: Physical sciences↗

Characterizing TES Power Noise for Future Single Optical-Phonon and Infrared-Photon Detectors

In this letter, we present the performance of a 100 μm × 400 μm × 40 nm W Transition-Edge Sensor with a critical temperature of 40 mK. This device has a noise equivalent power of 1.5×10-18 W/Hz, in a bandwidth of 2.6 kHz, indicating a resolution for Dirac delta energy depositions of 40 ± 5 meV (rms). The performance demonstrated by this device is a critical step toward developing a O(100) meV threshold athermal phonon detector for low-mass dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Case Study of High-Throughput Drug Screening and Remote Data Collection for SARS-CoV-2 Main Protease by Using Serial Femtosecond X-ray Crystallography

Since early 2020, COVID-19 has grown to affect the lives of billions globally. A worldwide investigation has been ongoing for characterizing the virus and also for finding an effective drug and developing vaccines. As time has been of the essence, a crucial part of this research has been drug repurposing; therefore, confirmation of in silico drug screening studies have been carried out for this purpose. Here we demonstrated the possibility of screening a variety of drugs efficiently by leveraging a high data collection rate of 120 images/second with the new low-noise, high dynamic range ePix10k2M Pixel Array Detector installed at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Linac Coherent Light Source (LCLS). The X-ray Free-Electron Laser (XFEL) is used for remote high-throughput data collection for drug repurposing of the main protease (Mpro) of SARS-CoV-2 at ambient temperature with mitigated X-ray radiation damage. We obtained multiple structures soaked with nine drug candidate molecules in two crystal forms. Although our drug binding attempts failed, we successfully established a high-throughput Serial Femtosecond X-ray crystallographic (SFX) data collection protocol.

60 APPLIED LIFE SCIENCES↗

A sub-picosecond digital clock monitoring system

We describe a low-cost system designed to monitor wander in digital clocks with a precision of ≤ 1 ps. With this system we have shown that it is possible to track phase variations at the sub-picosecond level by adding noise to a reference clock. As in many cases where a clock is part of a complex distribution network small changes in temperature and other effects can lead to small changes in the clock's phase. As a further demonstration of the system, we have used it to measure the phase changes induced in optical signals in fibers.

47 OTHER INSTRUMENTATION↗

Mechanical Actuation Mechanism Design for Cryogenic Microwave Cavities in Axion Dark Matter Searches

Resonant Microwave Cavities are placed in a strong magnetic field at cryogenic temperatures (~.1K) in order to try to convert axions into detectable photons. A major challenge is to tune the cavity to allow no interference with the desired environment used for the experiment, which enables the system to operate near absolute zero and maintain superconductivity, thereby reducing noise as much as possible. My project focuses on developing and testing a low-thermal-conductivity gear reduction system with a 1000:1 ratio for cavity tuning. This gear system could significantly improve the thermal and electromagnetic interference of the tuning mechanism, helping ADMX scan for axions more accurately.

Ortega, Giancarlo [Marquette U.; Fermilab]↗

Floquet Prethermalization with Lifetime Exceeding 90 s in a Bulk Hyperpolarized Solid

Here, we report the observation of long-lived Floquet prethermal states in a bulk solid composed of dipolar-coupled 13 C nuclei in diamond at room temperature. For precessing nuclear spins prepared in an initial transverse state, we demonstrate pulsed spin-lock Floquet control that prevents their decay over multiple-minute-long periods. We observe Floquet prethermal lifetimes $T^{'}_{2}$≈90.9 s, extended >60 000-fold over the nuclear free induction decay times. The spins themselves are continuously interrogated for ~10 min, corresponding to the application of ≈5.8×10 6 control pulses. The 13 C nuclei are optically hyperpolarized by lattice nitrogen vacancy centers; the combination of hyperpolarization and continuous spin readout yields significant signal-to-noise ratio in the measurements. This allows probing the Floquet thermalization dynamics with unprecedented clarity. We identify four characteristic regimes of the thermalization process, discerning short-time transient processes leading to the prethermal plateau and long-time system heating toward infinite temperature. This Letter points to new opportunities possible via Floquet control in networks of dilute, randomly distributed, low-sensitivity nuclei. In particular, the combination of minutes-long prethermal lifetimes and continuous spin interrogation opens avenues for quantum sensors constructed from hyperpolarized Floquet prethermal nuclei.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Low Cost Infrasound Sensor Packages

Sandia National Laboratories has tested and evaluated the performance of the following five models of low-cost infrasound sensors and sensor packages: Camas microphone, Gem Infrasound Logger, InfraBSU sensor, Raspberry Boom, and the Samsung S10 smartphone utilizing the Redvox app. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, self-noise, dynamic range, response, passband, linearity, sensitivity variation due to changes in static pressure and temperature, and sensitivity to vertical acceleration. The infrasound monitoring community has leveraged such sensors and integrated packages in novel ways; better understanding the performance of these units serves the geophysical monitoring community.

42 ENGINEERING↗

JWST Noise Floor. II. Systematic Error Sources in JWST NIRCam Time Series

The James Webb Space Telescope (JWST) holds great promise for characterizing atmospheres of transiting exoplanets, potentially providing insights into Earth-sized planets within the habitable zones of M-dwarf host stars if photon-limited performance can be achieved. Here, we discuss the systematic error sources that are expected to be present in grism time-series observations with the NIRCam instrument. We find that pointing jitter and high-gain antenna moves in addition to the detectors’ subpixel crosshatch patterns will produce relatively small variations (less than 6 parts per million, ppm). The time-dependent aperture losses due to thermal instabilities in the optics can also be kept to below 2 ppm. To achieve these low noise values, it is important to employ a sufficiently large (more than 11) extraction aperture. Persistence due to charge-trapping will have a minor (less than 3 ppm) effect on the time series 20 minutes into an exposure and is expected to play a much smaller role than it does for the Hubble Space Telescope WFC3 detectors. We expect detector temperature fluctuations to contribute less than 3 ppm. In total, our estimated noise floor from known systematic error sources is only 9 ppm per visit. We urge caution, however, because unknown systematic error sources could be present in flight and will only be measurable on astrophysical sources such as quiescent stars. We find that reciprocity failure may introduce a perennial instrument offset at the 40 ppm level, so corrections may be needed when a multi-instrument multi-observatory spectrum is stitched together over wide wavelength ranges.

47 OTHER INSTRUMENTATION↗

Selective modulation of electronic transport in VO 2 induced by 10 keV helium ion irradiation

Vanadium dioxide (VO 2 ) manifests an abrupt metal–insulator transition (MIT) from monoclinic to rutile phases, with potential use for tunable electronic and optical properties and spiking neuromorphic devices. Understanding pathways to modulate electronic transport in VO 2 , as well as its response to irradiation (e.g., for space applications), is critical to better enable these applications. In this work, we investigate the selective modulation of electronic transport in VO 2 films subject to different 10 keV helium ion (He + ) fluences. Under these conditions, the resistivity in the individual monoclinic and rutile phases varied by 50%–200%, while the MIT transformation temperature remains constant within 4 °C independent of irradiation fluence. Importantly, different trends in the resistivity of the monoclinic and rutile phases were observed both as a function of total He fluence as well as in films grown on different substrates (amorphous SiO 2 /Si vs single crystal Al 2 O 3 ). Through a combination of measurements including majority carrier sign via Seebeck, low frequency noise, and TEM, our investigation supports the presence of different kinds of point defects (V in; O in), which may arise due to grain boundary defect interactions. Our work suggests the utility of He irradiation for the selective modulation of VO 2 transport properties for neuromorphic, in contrast to other established but non-selective methods, like doping.

36 MATERIALS SCIENCE↗

Meta‐Analysis and Regression Modeling of the Impacts of Four Indoor Environmental Quality Metrics on Office Performance

Awareness of how buildings interact with the occupant experience—especially human performance—is becoming more prevalent, as seen by increasing interest and investment in healthy built environments. However, there is a need to synthesize the wide array of existing indoor environmental assessment and performance research in a way that can translate directly to building design and operation. Existing research in this area typically focuses on a single isolated metric and has not focused on making the results utilizable by building practitioners. The aim of this research is to investigate existing office performance literature through meta‐analyses and produce regression models for four indoor environmental quality (IEQ) metrics to support critical decision‐making for building operation and renovation. To reach this aim, a literature review was conducted to identify studies that measure the impact of changing ventilation rate, temperature, horizontal illuminance, and noise level in offices on occupant task performance. This repository of field and laboratory studies was analyzed to visualize the trends between the selected IEQ metrics and task performance. The temperature, ventilation rate, and horizontal illuminance regression models showed clear improvement potential when modifying indoor conditions toward the defined high‐performance range, while the regression model for noise level was inconclusive. The discussion notes the importance of designing holistically for all components of these IEQ categories to utilize the results, for example, good filtration on outdoor air for quantifying ventilation impact and uniform overhead lighting with low contrast for quantifying horizontal illuminance impact. The novelty of this work is in considering multiple facets of the indoor environment under a single, unified analysis schema and producing IEQ‐based performance gains that can directly inform cost‐benefit analyses of building design and renovation.

60 APPLIED LIFE SCIENCES↗

Single photon emitters in van der Waals solids for quantum photonics: materials, theory and molecular-scale characterization probes

Strong light–matter interactions in two-dimensional layered materials (2D materials) have attracted the interest of researchers from interdisciplinary fields for more than a decade now. A unique phenomenon in some 2D materials is their large exciton binding energies (BEs), increasing the likelihood of exciton survival at room temperature. It is this large BE that mediates the intense light–matter interactions of many of the 2D materials, particularly in their monolayer limit, where the interplay of excitonic phenomena poses a wealth of opportunities for high-performance optoelectronics and quantum photonics. Within quantum photonics, quantum information science (QIS) is growing rapidly, where photons are a promising platform for information processing due to their low-noise properties, excellent modal control, and long-distance propagation. A central element for QIS applications is a single photon emitter (SPE) source, where an ideal on-demand SPE emits exactly one photon at a time into a given spatiotemporal mode. Recently, 2D materials have shown practical appeal for QIS which is directly driven from their unique layered crystalline structure. This structural attribute of 2D materials facilitates their integration with optical elements more easily than the SPEs in conventional three-dimensional solid state materials, such as diamond and SiC. In this review article, we will discuss recent advances made with 2D materials towards their use as quantum emitters, where the SPE emission properties maybe modulated deterministically. Here, the use of unique scanning tunneling microscopy tools for the in-situ generation and characterization of defects is presented, along with theoretical first-principles frameworks and machine learning approaches to model the structure-property relationship of exciton–defect interactions within the lattice towards SPEs. Given the rapid progress made in this area, the SPEs in 2D materials are emerging as promising sources of nonclassical light emitters, well-poised to advance quantum photonics in the future.

2D layered materials↗

Role of Ocean and Atmosphere Variability in Scale-Dependent Thermodynamic Air-Sea Interactions

This study investigates the influence of oceanic and atmospheric processes in extratropical thermodynamic air-sea interactions resolved by satellite observations (OBS) and by two climate model simulations run with eddy-resolving high-resolution (HR) and eddy-parameterized low-resolution (LR) ocean components. Here, in this work, spectral methods are used to characterize the sea surface temperature (SST) and turbulent heat flux (THF) variability and co-variability over scales between 50 and 10,000 km and 60 days to 80 years in the Pacific Ocean. The relative roles of the ocean and atmosphere are interpreted using a stochastic upper-ocean temperature evolution model forced by noise terms representing intrinsic variability in each medium, defined using climate model data to produce realistic rather than white spectral power density distributions. The analysis of all datasets shows that the atmosphere dominates the SST and THF variability over zonal wavelengths larger than ~2,000–2,500 km. In HR and OBS, ocean processes dominate the variability of both quantities at scales smaller than the atmospheric first internal Rossby radius of deformation (R 1 , ~600–2,000 km) due to a substantial ocean forcing coinciding with a weaker atmospheric modulation of THF (and consequently of SST) than at larger scales. The ocean forcing also induces oscillations in SST and THF with periods ranging from intraseasonal to multidecadal, reflecting a red spectrum response to ocean forcing similar to that driven by atmospheric forcing. Such features are virtually absent in LR due to a weaker ocean forcing relative to HR.

54 ENVIRONMENTAL SCIENCES↗

High-Density Polyethylene Custom Focusing Lenses for High-Resolution Transient Terahertz Biomedical Imaging Sensors

Transient terahertz time-domain spectroscopy (THz-TDS) imaging has emerged as a novel non-ionizing and noninvasive biomedical imaging modality, designed for the detection and characterization of a variety of tissue malignancies due to their high signal-to-noise ratio and submillimeter resolution. We report our design of a pair of aspheric focusing lenses using a commercially available lens-design software that resulted in about 200 × 200-μm2 focal spot size corresponding to the 1-THz frequency. The lenses are made of high-density polyethylene (HDPE) obtained using a lathe fabrication and are integrated into a THz-TDS system that includes low-temperature GaAs photoconductive antennae as both a THz emitter and detector. The system is used to generate high-resolution, two-dimensional (2D) images of formalin-fixed, paraffin-embedded murine pancreas tissue blocks. The performance of these focusing lenses is compared to the older system based on a pair of short-focal-length, hemispherical polytetrafluoroethylene (TeflonTM) lenses and is characterized using THz-domain measurements, resulting in 2D maps of the tissue refractive index and absorption coefficient as imaging markers. For a quantitative evaluation of the lens effect on the image resolution, we formulated a lateral resolution parameter, R2080, defined as the distance required for a 20–80% transition of the imaging marker from the bare paraffin region to the tissue region in the same image frame. The R2080 parameter clearly demonstrates the advantage of the HDPE lenses over TeflonTM lenses. The lens-design approach presented here can be successfully implemented in other THz-TDS setups with known THz emitter and detector specifications.

47 OTHER INSTRUMENTATION↗