Search NASA⌕ Search

SEARCH · Search NASA

Results for “low-voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Tabletop Testing for EV Charging Ecosystem PKI (Project T34PKI Final Report)

To test the communications and cybersecurity functionality, Electric Vehicle and charging station vendors have had to ship their products to in-person testing events. This is cumbersome, expensive, inefficient, and an impediment to rapid time-to-deployment. In this project Sandia used COTS hardware and Open-Source Software to develop and demonstrate a more agile, productive approach: testing low-voltage controllers independently from high-voltage power delivery sub-systems. This approach allows communications controllers to be transported easily (e.g. shipped at low cost, checked as airline baggage); set up on a table-top (“bench testing”); and use ordinary 120 VAC outlets to conduct agile testing. Table-top platforms become end nodes that can connect to laboratory and cloud-based servers to test communications and cybersecurity, specifically Public Key Infrastructure (PKI) functionality and interoperability, separately from EV battery charging (power/energy transfer) functionality.

33 ADVANCED PROPULSION SYSTEMS↗

Frequency Domain Reflectometry (FDR) Simulation Techniques for Digital Twin Representation of an Electrical Cable

Simulation of cable system response to frequency domain reflectometry (FDR) tests can be instrumental to understanding these tests and the nature and influence of various cable anomalies on test signatures. Reflectometry simulations are based upon a finite element representation of cable conductors and insulation to produce an S-parameter at each evaluated frequency. The aggregate collection of cable model S-parameters can simulate the influence on a test signal injected into a physical cable. Such an approach was undertaken in this work to produce a digital twin simulation of a low-voltage electrical cable. The electrical cable digital twin examined the influence of test simulation parameters and the relative influence of cable anomalies, including thermal aging, water or moisture exposure, water or moisture ingress, and other anomalies. The digital twin in this work included modeling of the conductors, insulation, jacket, and surrounding environment (air, water, etc.). The digital twin could be expanded to include cable bends, junctions and splices, branch or T systems, and termination impedances of motors or instruments. Observations and conclusions of this work include: 1. Fully 3D digital twin simulation of an electrical cable using an FDR approach is possible. However, there are tradeoffs between simulation fidelity and solution time, which must be balanced to ensure the simulation solves in an adequate amount of time (e.g., less than 20 minutes). Simulation parameters to balance include frequency bandwidth, number of frequencies, mesh density, connection impedance, and permittivity tolerance. 2. The digital twin simulation can explain FDR sensitivity to various cable anomalies, including entry and exit from an oven or water bath. 3. The digital twin simulation FDR response attenuates with distance along the cable and is further affected by the frequency bandwidth, which is similar to that observed with physical measurements. 4. The resolution of the digital twin FDR peaks increased with increasing bandwidth and with increasing number of frequencies, again similar to physical measurements. 5. The presence of multiple anomalies in the digital twin does not substantially attenuate the FDR response to anomalies located beyond the first encountered anomaly and impedance mismatch. 6. Spectral variation of the permittivity did not have a significant effect on the FDR response compared to a fixed nominal value. 7. Extension of the digital twin to 1000 ft still allowed for detection of distal anomalies near the far end of the electrical cable from the instrument connection point. 8. The ARENA test bed facilitates efficient NDE evaluations of well understood cable anomalies with various NDE methods without risking actual plant damage.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effectively Considering the Distribution System in Integrated Resource Plans

While electricity planning practices vary by state and utility based on utility type and market structure, integrated resource planning (IRP) remains a prominent vehicle — even in states with centrally-organized wholesale electricity markets. IRP focuses on meeting forecasted long-term electricity needs. Typically, utilities have not considered impacts of design and operation of the low-voltage distribution network in IRP. With advanced capabilities of grid-edge technologies to generate and store electricity and provide load flexibility, and large utility investments in distribution systems, it's increasingly important to consider at least some distribution planning elements in IRP. This report considers the value proposition for doing so, such as reducing utility costs through resource co-optimization and strategic siting of grid-edge resources, and idenfities the most important touchpoints between planning for bulk power and distribution systems and provide a range of tactics for integrating these two processes.

Relf, Grace [Lawrence Berkeley National Laboratory↗

POWER ELECTRONICS GRID TIED SYSTEM FINAL REPORT

Across the country, electric utilities are grappling with the persistent hurdles of integrating Distributed Energy Resources (DERs). Managing these assets safely and effectively is a complex endeavor, complicated by varying ownership structures, management philosophies, and the diversity of the technologies themselves. Consequently, the industry has seen a proliferation of bespoke system designs, control strategies, and communication frameworks—forcing utilities to spend significant time and resources developing one-off integration solutions. This project addressed these integration hurdles through a scalable demonstration of intelligent devices designed to coordinate and control diverse resources in low-voltage applications. This concept minimized the need for complex integration by transforming the separate DERs into a dispatchable virtual power plant (VPP) with integrated resiliency functions (called a Node). By collaborating with a utility partner, the project focused on developing rapidly implementable use cases that bridged the gap between theoretical control and real-world deployment

99 GENERAL AND MISCELLANEOUS↗

Ripple-Type Voltage Control for Extreme-Event Contingencies: Preprint

Frequent and intense extreme events make grid operation unprecedentedly challenging. Disruptive events could lead to dangerous voltage drops and even voltage collapse if corrective actions are not quickly taken. In this paper, we present a real-time algorithm for voltage control suitable for mitigating electric grid damage scenarios. In our strategy, when agents (generators, substations) experience a dangerous undervoltage, they first respond locally. When the local control resources are depleted, agents seek assistance from peer nodes over a communication network. The algorithm is simulated on a realistic test transmission system. Using fragility curve methodology, we simulate hurricane damages to the components of the synthetic 2000-bus grid representing the ERCOT system. Although being tested over a damaged grid after a hurricane event, our algorithm can be equally successfully applied to any other emergency low-voltage situation.

extreme weather events↗

Overvoltage Prevention and Curtailment Reduction Using Adaptive Droop-Based Supplementary Control in Smart Inverters

Recent developments in the renewable energy sector have seen an unprecedented growth in residential photovoltaic (PV) installations. However, high PV penetration levels often lead to overvoltage problems in low-voltage (LV) distribution feeders. Smart inverter control such as active power curtailment (APC)-based overvoltage control can be implemented to overcome these challenges. The APC technique utilizes a constant droop-based approach which curtails power rigidly, which can lead to significant energy curtailment in the LV distribution feeders. In this paper, different variations of the APC technique with linear, quadratic, and exponential droops have been analyzed from the point-of-view of energy curtailment for a LV distribution network in North America. Further, a combinatorial approach using various droop-based APC methods in conjunction with adaptive dynamic programming (ADP) as a supplementary control scheme has also been proposed. The proposed approach minimizes energy curtailment in the LV distribution network by adjusting the droop gains. Simulation results depict that ADP in conjunction with exponential droop reduces the energy curtailment to approximately 50% compared to using the standard linear droop.

42 ENGINEERING↗

Power Split Supercharging: A Mild Hybrid Approach to Boost Fuel Economy

This work investigates an innovative low-voltage (<60 V) hybrid device that enables engine boosting and downsizing in addition to mild hybrid functionalities such as regenerative braking, start-stop, and torque assist. A planetary gear set and a brake permit the power split supercharger (PSS) to share a 9 kW motor between supercharging the engine and direct torque supply to the crankshaft. In contrast, most e-boosting schemes use two separate motors for these two functionalities. This single motor structure restricts the PSS operation to only one of the supercharging or parallel hybrid modes; therefore, an optimized decision making strategy is necessary to select both the device mode and its power split ratio. An adaptive equivalent consumption minimization strategy (A-ECMS), which uses the battery state of charge (SoC) history to adjust the equivalence factor, is developed for energy management of the PSS. The A-ECMS effectiveness is compared against a dynamic programming (DP) solution with full drive cycle preview through hardware-in-the-loop experiments on an engine dynamometer testbed. The experiments show that the PSS with A-ECMS reduces vehicle fuel consumption by 18.4% over standard FTP75 cycle, compared to a baseline turbocharged engine, while global optimal DP solution decreases the fuel consumption by 22.8% compared to the baseline.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Endpoint Use Efficiency Comparison for AC and DC Power Distribution in Commercial Buildings

Advances in power electronics and their use in Miscellaneous Electric Loads (MELs) in buildings have resulted in increased interest in using low-voltage direct current (DC) power distribution as a replacement for the standard alternating current (AC) power distribution in buildings. Both systems require an endpoint converter to convert the distribution system voltage to the MELs voltage requirements. This study focused on the efficiency of these endpoint converters by testing pairs of AC/DC and DC/DC power converters powering the same load profile. In contrast to prior studies, which estimated losses based on data sheet efficiency and rated loads, in this study, we used part load data derived from real-world time-series load measurements of MELs and experimentally characterized efficiency curves for all converters. The measurements performed for this study showed no systematic efficiency advantage for commercially available DC/DC endpoint converters relative to comparable, commercially available AC/DC endpoint converters. For the eight appliances analyzed with the pair of converters tested, in 50%, the weighted energy efficiency of the DC/DC converter was higher, while, for the other 50%, the AC/DC converter was. Additionally, the measurements indicated that the common assumption of using either data sheet efficiency values or efficiency at full load may result in substantial mis-estimates of the system efficiency.

AC/DC converters↗

Adaptive Fault Detection Based on Neural Networks and Multiple Sampling Points for Distribution Networks and Microgrids

Smart networks such as microgrid (MG) and active distribution networks (ADN) have been recently playing an important role in power system operation. The design and implementation of appropriate protection systems for such networks must be addressed, which imposes new technical challenges. This paper presents the implementation and validation aspects of an adaptive fault detection strategy based on neural networks (NNs) and multiple sampling points for ADN and MG. The solution is implemented on an edge device. Artificial NNs are used to derive a data-driven model that uses only local measurements to detect fault states of the network without the need for communication infrastructure. Multiple sampling points are used to derive a data-driven model, which allows the generalization considering the implementation in physical systems. The adaptive fault detector model is implemented on a Jetson Nano system, which is a single-board computer (SBC) with a small Graphic Processing Unit (GPU) intended to run machine learning loads at the edge. The proposed method is tested in a physical, real-life, low-voltage network located at Universidad del Norte, Colombia. This testing network is based on the IEEE-13 Node Test Feeder scaled down to 220 V. The validation in a simulation environment shows the accuracy and dependability above 99.6%, while the real-time tests show the accuracy and dependability of 95.5% and 100%, respectively. Without hard-to-derive parameters, the easy-to-implement embedded model highlights the potential for real-life applications.

42 ENGINEERING↗

A High-Frequency Planar Transformer with Medium-Voltage Isolation: Preprint

This paper presents the design of a low-loss, high-frequency planar transformer having medium-voltage (10's of kV) isolation capability while transformer primary and secondary windings are interleaved to reduce losses. Medium-voltage isolation between adjacent printed circuit board (PCB) layers is extremely challenging using traditional PCB dielectrics. The isolation requirement is met using PCB with $7$\,kV/mil polyimide (Panasonic Felios RF775) as the dielectric, and by an appropriate layout of the windings and the inter-winding vias. The transformer is used to implement a dual active bridge (DAB) converter in a stackable dc-ac architecture where the dc port is connected to a photovoltaic (PV) string and ac outputs are connected in series to achieve direct PV string-to-medium voltage conversion without the need for low-voltage collection or a bulky line frequency transformer. Since each DAB transformer processes time-varying power, a design methodology is developed to minimize line-cycle-averaged losses. Experimental results are presented for a 1:1 planar transformer in a 7.5\,kW SiC-based dc-to-ac module operating at 200 kHz. Isolation of 26 kV between the primary and secondary layers and between the windings and the core is verified using a hipot tester.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Electroabsorption optical modulator

An electroabsorption modulator that operates based on electroabsorption of a surface plasmon polariton mode is improved by various structural changes and/or selection of different materials. For example, at least a portion of the waveguide may be made to be conductive, e.g., by doping. Also, layers that make up the modulator structure may be placed along sides of waveguides in addition to or instead of simply on the top thereof. High permittivity gate dielectric materials may be employed. Also, materials other than ITO may be employed as a transparent conductor. Such an improved plasmonic electroabsorption modulator can be fabricated using standard semiconductor processing techniques and may be integrated with standard photonic integrated circuits, including silicon photonics and compound semiconductor-based platforms. Advantageously, high-speed, low-voltage operation over a wide spectrum of wavelengths may be achieved.

Wood, Michael↗

Grid-Connected Self-Synchronous Cascaded H-Bridge Inverters with Autonomous Power Sharing: Preprint

Cascaded inverters are widely applied in applications where elevated ac voltages are required while using semiconductor devices with lower voltage ratings. Here, we focus on structures that require localized power transfer between low-voltage sources/loads dispersed across inverter dc links and the inverter ac-sides are series-connected across a three-phase medium-voltage ac grid. To date, decentralized controllers that allow for bi-directional power transfer in such systems are limited. To fill this gap, we propose a virtual oscillator controller which modulates the power processed by each inverter in a purely decentralized manner.

autonomous power sharing↗

Optimized Dispatch of Distributed Energy Resources for Resiliency and Power Quality Improvements at the Grid-Edge

Distributed Energy Resources (DERs) installed on low-voltage distribution systems, both utility-owned and nonutility owned may be employed to make improvements to system resiliency and power quality, in addition to simply serving load demand. By selectively dispatching active and reactive power from these existing DERs, improvements in voltage profiles and service availability during adverse events may be achieved. Further benefits can be gained by optimally choosing which DERs to dispatch power from, and the distribution of power from those DERs. For a given operating condition, using Linear Programming methods, optimal power dispatch values for individual DERs can be determined, while considering variables such as voltage gains, losses in the lines and the DERs, and DER reserve capacities. One such optimization technique is developed in this paper, and results from a real-time simulation study on a modified IEEE 13-bus distribution system with three DERs, are being presented. The operation of the optimized DER selection and dispatch algorithm is shown during normal operation of the transmission system when the DERs operate in grid-connected mode. Similar analyses can drive decision making during transmission system failure when the DERs operate in grid-forming or islanded mode.

Chowdhury, Prithwiraj Roy↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data: Preprint

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data

Many distribution network monitoring and control applications - including state estimation, Volt/VAr optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder-head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure (AMI)↗

Active SOC Balancing for a Multi-Chemistry Battery Pack with Reduced Number of Converters: Preprint

In energy storage systems using second-life or multi-chemistry cells, an active state of charge (SOC) balancing system can prolong pack life and enhance performance by utilizing the healthier cells more than those which are heavily degraded. However, the high cost of the active balancing system, particularly in converter-based solutions, prevents their widespread usage. Considering this, existing research has proposed numerous balancing systems utilizing only one converter. However, such systems may compromise the balancing speed too much. Therefore, this work proposes two active balancing systems with a reduced number of converters for 14-16 series-connected cells. One system uses two converters for direct cell-to-cell balancing. The other uses a time-multiplexed approach to exchange energy via an auxiliary low-voltage (LV) bus using four converters. The proposed balancing systems are compared to two baseline systems, a single converter cell-to-cell balancing system, and a 14 converter balancing system with an auxiliary LV bus.

battery pack↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗