Search NASA⌕ Search

SEARCH · Search NASA

Results for “maintainability systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Detection and imaging of chemicals and hidden explosives using terahertz time-domain spectroscopy and deep learning

Detecting concealed chemicals and explosives remains a critical challenge in global security. Terahertz time-domain spectroscopy (THz-TDS) offers a promising non-invasive and stand-off detection technique owing to its ability to penetrate optically opaque materials without causing ionization damage. While many chemicals exhibit distinct spectral features in the terahertz range, conventional terahertz-based detection methods often struggle in real-world environments, where variations in sample geometry, thickness, and packaging can lead to inconsistent spectral responses. In this study, we present a chemical imaging system that integrates THz-TDS with deep learning to enable accurate pixel-level identification and classification of different explosives. Operating in reflection mode and enhanced with plasmonic nanoantenna arrays, our THz-TDS system achieves a peak dynamic range of 96 dB and a detection bandwidth of 4.5 THz, supporting practical, stand-off operation. By analyzing individual time-domain pulses with deep neural networks, the system exhibits strong resilience to environmental variations and sample inconsistencies. Blind testing across eight chemicals—including pharmaceutical excipients and explosive compounds—resulted in an average classification accuracy of 99.42% at the pixel level. Notably, the system maintained an average accuracy of 88.83% when detecting explosives concealed under opaque paper coverings, demonstrating its robust generalization capability. These results highlight the potential of combining advanced terahertz spectroscopy with neural networks for highly sensitive and specific chemical and explosive detection in diverse and operationally relevant scenarios.

Imaging and sensing↗

Closed-Loop Control of Active Nematic Flows

Stabilizing and shaping autonomous flows of active fluids is a fundamental challenge and a prerequisite for applications. We embed a light-responsive microtubule-based nematic in a proportional-integral control loop that adjusts the applied light intensity in response to real-time measurements of the spatially averaged flow speed. The self-regulating hardware-software-wetware system maintains a target flow speed against external or internal perturbations, including protein aging and aggregation, sample-to-sample variability, and temperature variation. Varying the controller’s gains reveals antagonistic roles between feedback and intrinsic processes, leading to nontrivial dynamics observed in fluctuation spectra. In particular, oscillations emerge from the interplay between the controller, motor binding kinetics, and active hydrodynamic relaxation. Accounting for the underlying binding timescale, our coarse-grained model and nematohydrodynamics simulations corroborate these observations. This work provides insight into the coupled dynamics of controlled active matter, laying the foundation for spatiotemporal patterning of active stress to generate and stabilize new dynamical configurations.

Active nematics↗

Synthesis and characterization of electron beam irradiation-induced damage in polycrystalline metal thin films

High-energy physics research, industrial sterilizing, and material processing depend extensively on electron beam accelerators. Exit windows are crucial components of such electron accelerator systems, maintaining vacuum integrity inside the machine while providing mechanical strength, thermal stability, and radiation resistance at the beam-target interface. In this study, thin metallic films of Ni, Ti, Cr, and V were explored for use in electron beam exit windows, and their properties were compared with the properties of their bulk counterparts. Simulation results of metal foils predicted Ti to exhibit less beam power dissipation compared to Ni. However, Ni possesses superior mechanical and structural properties compared to Ti. The performance of these films under electron beam irradiation was examined by depositing thin layers of these films on silicon and metallic substrates using magnetron sputtering and exposing them to e-beam irradiation in a controlled setup. The deposited films were subjected to a dose of approximately 66 kGy at a beam energy of 10 MeV and characterized prior to and postexposure to the beam using field emission scanning electron microscopy, atomic force microscopy, x-ray diffraction (XRD), and nanoindentation. Particular emphasis was given to characteristics like the grain structure, surface morphology, dislocation density, and hardness. XRD patterns revealed irradiation-induced changes in peak intensities, while the crystallinity remained largely unchanged. Nanoindentation results showed that the pristine and irradiated Ti and Ni films were twice as hard when compared to bulk Ti and Ni samples, regardless of the substrate type used (Si or bulk Ti, or Ni). These results emphasize the superior mechanical properties of thin metal films compared to their bulk counterparts. In conclusion, this study advances the optimization of thin film materials for robust and efficient e-beam applications, ensuring improved durability and operational reliability.

AFM↗

Cyber-Informed Engineering for Strategic Planning

The CIE Guide for Engaging Organizational Leadership: Board and C-Suite describes how to apply CIE at the senior-level of organizational management. This guidance integrates CIE concepts into theory and practice of guiding coalition leadership to improve permeation of CIE concepts throughout organizational culture. This guide incorporates feedback from CIE community of practice volunteers in a study of how business administrative and strategic planning and management guidance and course materials can be applied to CIE implementation throughout an organization's principles and processes. This guide defines the interests guiding senior leadership, managers and supervisors, and technicians and workers involved in creating and operating and maintaining systems, and cultural/ historical/ political assumptions or influences shaped the landscape that could facilitate or impede development of CIE. The included guidance for organizational strategic management and leadership can be imbedded into contract guidance based on the CIE implementation guide and lessons learned from industry application.

97 MATHEMATICS AND COMPUTING↗

Closed-loop control of active nematic flows

Stabilizing and shaping autonomous flows of active fluids is a fundamental challenge and a prerequisite for applications. We embed a light-responsive microtubule-based nematic in a proportional-integral control loop that adjusts the applied light intensity in response to real-time measurements of the spatially averaged flow speed. The self-regulating hardware/software/wetware system maintains a target flow speed against external or internal perturbations, including protein aging and aggregation, sample-to-sample variability, and temperature variation. Varying the controller’s gains reveals antagonistic roles between feedback and intrinsic processes, leading to nontrivial dynamics observed in fluctuation spectra. In particular, oscillations emerge from the interplay between the controller, motor binding kinetics, and active hydrodynamic relaxation. Accounting for the underlying binding timescale, our coarse-grained model and nematohydrodynamics simulations corroborate these observations. This work provides insight into the coupled dynamics of controlled active matter, laying the foundation for spatiotemporal patterning of active stress to generate and stabilize new dynamical configurations.

Nishiyama, Katsu [Brandeis Univ., Waltham, MA (Uni↗

4-gc parametric amplifier for satellite communication ground station receiver

This paper describes the design and performance of a 4-gc parametric amplifier which meets the stringent requirements of a satellite ground station receiver. It consists of two cascaded stages of similar design: the first of these is operated at liquid nitrogen temperature and the second at room temperature. One 23-gc pump source is used for both amplifier stages. The combination of the two amplifier stages provides 38-db over-all gain, 45°K over-all system input noise temperature, 60-mc bandwidth, 0.1-db short-term gain stability and 0.3-db long-term gain stability. A carefully designed cryogenic system maintains the amplifier refrigerated with only infrequent refilling of the dewar, i.e., once every 10 days.

MASER↗

Video synchronization processor overcomes poor signal-to-noise ratio

Video synchronization processor overcomes poor signal-to-noise ratio which occurs during adverse signal conditions caused by flame attenuation, antenna pattern nulls, and near-horizon tracking. The system maintains sync lock far below the point where excessive noise would normally render the video useless.

Webb, D. L.↗

Telemetry receiver

Communications system maintains phase lock of weak telemetry signals with a minimal expenditure of power and bandwidth. An estimate of the frequency variation as a function of time is used to achieve coherent phase demodulation.

Gilchriest, C.↗

Inflight maintenance - Design for the future.

Extensive studies in the field of in-flight maintenance are reviewed. The progress made in this technology, and the design considerations essential for meeting the constraints imposed by a manned space mission lasting several years are outlined. Concepts for the design and packaging of maintainable systems are described. The requirement of full redundancy, with capability to perform in-flight maintenance, to provide reliability in long-duration missions is demonstrated from a reliability analysis.

Descamp, V. A.↗

Self-contained constant-temperature heat absorber

System maintains precise thermal control of heat producing component, is not affected by changes in external pressure, ambient thermal environment, or gravity, and operates in both static and spinning attitudes. Size of device's spin axis-oriented orifice determines container pressure which establishes boiling temperature of heat absorption medium.

Lopez, R. W.↗

Reduction of computer power interruptions

Inexpensive latching relays incorporating one-second time delay prove effective for maintaining system power in place of computer facility automatic shutdown sensors that are activated by minute power surges or spikes in 60 Hz input signal.

Oleson, C. C.↗

A summary of the application of active controls technology in the ATT system studies

The application of active controls technology to subsonic, long-range transport aircraft was investigated in three Advanced Transport Technology system studies. Relaxed stability requirements, maneuver and gust load alleviation, and active flutter suppression were the concepts considered. A different configuration was investigated for each of the three airframe manufacturers, and each had a somewhat different approach to the application of active controls technology. Consequently, the results varied in magnitude between the contractors, but several trends were noted. Relaxed stability requirements resulted in the largest benefits - reduced weight, increased return on investment, and decreased direct operating costs. Maneuver load alleviation, gust load alleviation, and flutter suppression resulted in much smaller benefits. Prior to application of active controls technology, a research and development program directed toward fulfilling data base requirements, establishing effective design techniques and criteria, improving systems maintainability and reliability, and demonstrating technology readiness must be completed.

Hood, R. V.↗

Air/salt/gravity-flow solar heating

Low-cost, easy-to-maintain system uses air collectors, molten-salt energy storage, and gravity flow. System is applicable to residential, commercial, industrial, and agricultural structures.

Jensen, R. N.↗

Development of a microbalance suitable for space application

The tapered element oscillating microbalance (TEOM), an ultrasensitive mass measurement device which is suitable for both particulate and vapor deposition measurements is described. The device can be used in contamination measurements, surface reaction studies, particulate monitoring systems or any microweighing activity where either laboratory or field monitoring capability is desired. The active element of the TEOM consists of a tube or reed constructed of a material with high mechanical quality factor and having a special taper. The element is firmly mounted at the wide end while the other end supports a substrate surface which can be composed of virtually any material. The tapered element with the substrate at the free (narrow) end is set into oscillation in a clamped free mode. A feedback system maintains the oscillation whose natural frequency will change in relation to the mass deposited on the substrate.

Patashnick, H.↗

Decoupler pylon - A simple, effective wing/store flutter suppressor

As an alternative to alleviating wing/store flutter by conventional passive methods or by more advanced active control methods, a quasi-passive concept, referred to as the decoupler pylon, is investigated which combines desirable features of both methods. Passive soft-spring/damper elements are used to decouple wing modes from store pitch modes, and a low-power control system maintains store alignment under changing mean loads. It is shown by analysis and wind tunnel tests that the decoupler pylon provides substantial increase in flutter speed and makes flutter virtually insensitive to inertia and center-of-gravity location of the store.

Reed, W. H.↗

Laboratory evaluation of an airborne ozone instrument that compensates for altitude/sensitivity effects

One problem encountered in the use of air-quality instrumentation on aircraft is the variation of instrument sensitivity with pressure as the result of altitude changes of the aircraft. Many instruments experience sensitivity changes of as much as a factor of 2 at altitudes of 6 km. Discussed are recent modifications to a chemiluminescent (ethylene) ozone detector that allow the instrument to automatically compensate for pressure/sensitivity effects. The modification provides automated mass flow rate control for both the sample and ethylene gas flows. The flow control systems maintain flow rate to within 15 percent for a 100-torr instantaneous pressure change, and flow rates are returned to the desired set points within 10 s after the pressure change. During simulated altitude changes (300 m/min from mean sea level to 3-km altitude), flow rates were controlled to within 3 percent of the set point. Laboratory data are summarized verifying the operation of the instrument for a pressure range of 760 torr (sea level) to 350 torr (approximately 20,000 ft) and an ozone concentration range from 20 to approximately 700 ppb.

Gregory, G. L.↗

Static Feed Water Electrolysis Subsystem Testing and Component Development

A program was carried out to develop and test advanced electrochemical cells/modules and critical electromechanical components for a static feed (alkaline electrolyte) water electrolysis oxygen generation subsystem. The accomplishments were refurbishment of a previously developed subsystem and successful demonstration for a total of 2980 hours of normal operation; achievement of sustained one-person level oxygen generation performance with state-of-the-art cell voltages averaging 1.61 V at 191 ASF for an operating temperature of 128F (equivalent to 1.51V when normalized to 180F); endurance testing and demonstration of reliable performance of the three-fluid pressure controller for 8650 hours; design and development of a fluid control assembly for this subsystem and demonstration of its performance; development and demonstration at the single cell and module levels of a unitized core composite cell that provides expanded differential pressure tolerance capability; fabrication and evaluation of a feed water electrolyte elimination five-cell module; and successful demonstration of an electrolysis module pressurization technique that can be used in place of nitrogen gas during the standby mode of operation to maintain system pressure and differential pressures.

Koszenski, E. P.↗

Grounding and fault protection of the SMUD PVI array

If large terrestrial photovoltaic (PV) power plants are to provide an economic source of generation, low-cost, reliable and easily maintainable systems must be developed. In addition, if the system is to be a central station powerplant owned and operated by an electric utility, the design must also be consistent with utility specifications and design standards. The particular solutions developed to address these issues, with regard to grounding and fault protection, for the first phase of the Sacramento Municipal Utility District's (SMUD) 100 mw(ac) PV powerplant are presented. This plant, known as PV1, is nominally rated at 1 mw(ac) and is scheduled to be in operation by the spring of 1984.

Rosen, D.↗