Search NASA⌕ Search

SEARCH · Search NASA

Results for “material sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Origins of radiation-induced optical attenuation in neutron-irradiated single-crystal sapphire at elevated temperatures

Sapphire (α-Al 2 O 3 ) is a candidate fiber-optic sensor material for extreme temperature environments, potentially including those of nuclear reactors. However, its optical transmission under high-dose neutron irradiation is not well understood compared with that of conventional fused silica. This study examined dimensional changes, optical transmission, and irradiation-induced defects in neutron-irradiated α-Al 2 O 3 at temperatures of 298 °C to 688 °C and doses of 3.2 to 12 dpa. Although previous studies attributed radiation-induced attenuation (RIA) at the highest irradiation temperatures to increased optical scattering from radiation-induced voids, our findings indicate that scattering from neither voids nor dislocation loops can explain the measured attenuation. Instead, absorption due to aluminum vacancy centers appears more likely based on a comparison of the spectral features of the measured optical attenuation with previous literature. Significant c-axis swelling (5.51 % ± 0.83 %) was observed in the 12 dpa, 592 °C irradiated sample, much higher than earlier measurements, suggesting temperature sensor drift of 543 °C to 1,140 °C. Void patterning was predominantly observed along the a-axis, differing from previous studies on polycrystalline samples, which showed c-axis patterning. Dislocation loops evolved into network dislocations with increasing temperature and dose; voids formed within these structures, showing no size or density changes, indicating an atypical growth mechanism.

Neutron irradiation↗

Synthesis and Characterization of MoNb Films Superconducting at 100-200 mK

We have developed a new transition-edge sensor material with critical temperature (T-c) in the range 100-200 mK. The new material is a solid solution of two superconducting components, MoxNb1-x, co-sputtered from two high-purity single-component targets (Mo and Nb). The T-c has a minimum (dT(c)/dx = 0) at an intermediate concentration of the components. We have optimized the deposition parameters and composition to provide films with a sharp superconducting transition at ~ 150 mK. We investigated structural features of the films and surface morphology using X-ray diffraction (XRD) and scanning electron microscopy. The XRD measurements indicate that the grown films are polycrystalline, with a preferred orientation along the (110) crystal direction and a clear correlation between superconducting properties and film microstructure.

superconducting alloys↗

Introduction: Photons and Ground-Based

A Conference on Measurement Techniques for Solar and Space Physics was held on 20-24 April 2015 in Boulder, Colorado, at the National Center for Atmospheric Research Center Green Campus. The present volume collects together the conference papers for photons and ground-based categories. This gathering of over 200 scientists and instrumentalists was born out of the desire to collect in one place the latest experiment and instrument technologies required for advancement of scientific knowledge in the disciplines of solar and space physics. The two goals for this conference and the subsequent publication of its content are (a) to describe measurement techniques and technology development needed to advance high priority science in the fields of solar and space physics; and (b) to provide a survey or reference of techniques for in situ measurement and remote sensing of space plasmas. Towards this end, our goal has always been inspired by the two 1998 Geophysical Monographs (Nos. 102 and 103) entitled, "Measurement Techniques in Space Plasmas" (particles and fields) [Pfaff et al., 1998a, 1998b], which have served as a reference and resource for advanced students, engineers, and scientists who wish to learn the fundamentals of measurement techniques and technology in this field. Those monographs were the product of an American Geophysical Union Chapman Conference that took place in Santa Fe, NM, in 1995: "Measurement Techniques in Space Plasmas-What Works, What Doesn't." Two decades later, we believe that it is appropriate to revisit this subject, in light of recent advances in technology, research platforms, and analysis techniques. Moreover, we now include direct measurements of neutral gases in the upper atmosphere, optical imaging techniques, and remote observations in space and on the ground. Accordingly, the workshop was organized among four areas of measurement techniques: particles, fields, photons, and ground-based. This two-set volume is largely composed of the content of that workshop. Special attention is given to those techniques and technologies that demonstrate promise of significant advancement in measurements that will enable the highest priority science as described in the 2012 National Research Council Decadal Survey [Baker and Zurbuchen et al., 2013]. Additionally, a broad tutorial survey of the current technologies is provided to serve as reference material and as a basis from which advanced and innovative ideas can be discussed and pursued. Included are instrumentation and techniques to observe the solar environment from its interior to its outer atmosphere, the heliosphere out to the interstellar regions, in geospace, and other planetary magnetospheres and atmospheres. To make significant progress in priority science as expressed in the National Research Council solar and space physics decadal survey and recent NASA Heliophysics roadmaps, identification of enabling new measurement techniques and technologies to be developed is required. Also, it is valuable to the community and future scientists and engineers to have a complete survey of the techniques and technologies used by the practitioners of solar and space physics. As with the 1995 conference and subsequent 1998 publication, it is incumbent on the community to identify those measurements that are particularly challenging and still require new techniques to be identified and tested to enable the necessary accuracy and resolution of certain parameters to be achieved. The following is a partial list of the measurement technique categories that are featured in these special publications: Particles; Thermal plasma to MeV energetic particles, neutral gas properties including winds, density, temperature, and composition, and enhanced neutral atom imaging; Fields; DC electric and magnetic fields, plasma waves, and electron drift instruments from which the plasma velocity information provides a measure of the DC electric field; Photons; Instruments sensitive from the near-infrared to X-rays; Contributions of techniques and technology for optical design, optical components, sensors, material selection for cameras, telescopes, and spectrographs; Ground based; Remote sensing methods for solar and geospace activity and space weather. The focus includes solar observatories, all-sky cameras, lidars, and ionosphere thermosphere mesosphere observatory systems such as radars, ionosondes, GPS receivers, magnetometers, conjugate observations, and airborne campaigns. The present volume collects together the papers for photons and ground-based categories. The companion volume collects together the papers for particles and fields categories. It is recognized that there are measurement techniques that overlap among the four categories. For example, use of microchannel plate detectors is used in photon and particle measurement techniques or the observation of visible photons and magnetic fields in space and on the ground share common technologies. Therefore, the reader should consider the entire collection of papers as they seek to understand particular applications. We hope that these volumes will be as valuable as a reference for our community as the earlier 1998 volumes have been.

Spann, James↗

Combined Experimental and Computational Study of Molybdenum and Niobium for Nuclear Sensor Application

Due to their novel electromagnetic and thermal properties, molybdenum (Mo) and niobium (Nb) become optimal temperature sensor materials for nuclear energy applications. We leveraged voltage recorded during a heat ramp to tune a computational method to predict the Seebeck electromotive force (EMF) of Mo and Nb. Using a combined Density Functional Theory (DFT) and Boltzmann Transport Equations (BTE) method the voltage was predicted but did not include the effects of temperature on atomic structure. Combining Ab Initio Molecular Dynamics (AIMD) and BTE included temperature effects on structure optimization and yielded voltages in a good agreement with experiment. Lanthanum (La) and Phosphorus (P) additives in Mo and Nb, respectively, could increase the EMF compared to those of the pure metals. The presence of oxygen (O) in Mo increases the EMF while O in Nb slightly reduces the EMF. Furthermore, our studies suggested that heat treatment-induced structural changes that lead to a reduction in voltage occur not only at the mesoscale as previously understood but also at the atomic scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetostrictive materials for enhanced sensors and electronic components

Magnetostriction is a property of magnetic materials that causes them to change their shape or dimensions when their magnetization changes. Low-cost, mechanically robust magnetostrictive sensors would be valuable for a wide range of applications addressing DOE's energy, environmental, and national security missions. Several examples include monitoring internal conditions of pipelines, enhancing implantable systems for the human body, and improving the electrical grid by providing real time sensors for detecting high impedance faults that may act as ignition sources for forest fires. Historically, magnetostrictive materials tended to be expensive and mechanically brittle, but recent developments in iron-based alloys, especially those that include dilute solutions of rare earth elements, have demonstrated useful magnetostriction values, mechanical robustness, and low costs. This project investigated addition of dilute cerium doping on the magnetostrictive properties of Fe-Ga and Fe-Al alloys. Advanced manufacturing techniques were applied to these materials to take advantage of rapid cooling of the alloy to stabilize desired phases and to make near net shape coupons. These coupons develop significant texturing, offering a route to target microstructures with exceptional performance.

36 MATERIALS SCIENCE↗

Towards a practical Johnson noise thermometer for long-term measurements in harsh environments

The impact of mechanical and chemical changes in conventional sensors such as thermocouples and resistance thermometers can be avoided by instead using temperature sensors based on fundamental thermometry. A prime example of this is Johnson noise thermometry, which is based on measurement of the fluctuations in the voltage of a resistor arising from thermal motion of charge carriers - i.e. the 'Johnson noise'. A Johnson noise thermometer never needs calibration and is insensitive to the condition of the sensor material. It is therefore ideally suited to long-term temperature measurements in harsh environments, such as nuclear reactor coolant circuits, in-pile measurements, nuclear waste management and storage, and severe accident monitoring. There have been a number of previous attempts to develop a Johnson noise thermometer for the nuclear industry, but none have reached commercial exploitation because of technical problems in practical implementation. The main challenge is to extract the tiny Johnson noise signal from ambient electrical noise influences, both from the internal amplification electronics, and from external electrical noise sources. Recent advances in electronics technology and digital signal processing techniques have opened up new possibilities for developing a viable, practical Johnson noise thermometer. We describe a project funded by the UK Technology Strategy Board (now Innovate UK) 'Developing the nuclear supply chain' call, currently underway, to develop a practical Johnson noise thermometer that makes use of innovative electronics for ultralow noise amplification and signal processing. The new electronics technology has the potential to help overcome the problems encountered with previous attempts at constructing a practical Johnson noise thermometer. An outline of the new developments is presented, together with an overview of the current status of the project. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Defect Generation and Evolution in Irradiated Epitaxial Films and Heterostructures of Fe 3 O 4 and Cr 2 O 3

Abstract The functionality of nuclear structural materials, sensors, and microelectronics in harsh environments such as radiation relies on understanding defect generation and evolution processes in oxide layers. The initial radiation response of epitaxial thin films of Fe 3 O 4 (111), Cr 2 O 3 (0001), and Fe 3 O 4 (111)/Cr 2 O 3 (0001) heterostructures deposited on Al 2 O 3 (0001) by oxygen‐assisted molecular beam epitaxy and irradiated with 200 keV He + is characterized. X‐ray diffraction and X‐ray absorption near edge spectroscopy showed that the Cr 2 O 3 layers underwent significant lattice expansion and disordering under irradiation, whereas the Fe 3 O 4 layers do not exhibit noticeable changes. In contrast, positron annihilation spectroscopy revealed an evolution of cation vacancy point defects in the Fe 3 O 4 layers into larger vacancy clusters with increasing irradiation, while the cation vacancies in Cr 2 O 3 remained primarily as single vacancies and small clusters. The results suggest that the Fe 3 O 4 lattice can utilize the free volume of the larger vacancy clusters to relax but the small vacancies in the Cr 2 O 3 lattice do not facilitate relaxation. Comparing defect concentrations in the single layer films versus the heterostructure suggests that point defects may cross the interface from Fe 3 O 4 into Cr 2 O 3 . Together, these results enhance the understanding of the initial defect evolution mechanisms in oxide layers in harsh irradiation environments.

36 MATERIALS SCIENCE↗

Progress Toward Fast Decay Energy Spectroscopy for Actinide Analysis

Decay energy spectroscopy (DES) is an increasingly popular technique for measuring isotopic composition of actinide samples for nuclear safeguards applications. Current approaches for actinide DES utilize milligram-scale external gold absorbers (> 0.1 nJ/K) that are integrated with actinide samples through mechanical kneading and are thermally connected to microcalorimeters using indium or gold wire bonds. This leads to relatively slow sensor rise time and, consequently, limits counting speed to a few counts per second. We are developing faster metallic magnetic calorimeter-based DES by integrating actinide samples with magnetic sensor materials. This reduces signal rise time and enables high counting speed while maintaining the ability to knead the radioactive source with the absorber. We have measured signal rise time of 0.7 μs with a 1.5 mg external gold absorber using this approach. Here, we also demonstrated online DES operation using an Ortec DSPEC 50, a commercially available data acquisition system developed for semiconductor detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of Different X-ray Techniques to Improve In-Service Carbon Fiber Reinforced Rope Inspection

Carbon fiber reinforced polymer ropes are gaining in significance in the fields of civil engineering and hoisting applications. Thus, methods of non-destructive testing (NDT) need to be developed and evaluated with respect to new challenges and types of defects. Particularly important is the development of in-service testing solutions which allow the integration in global online monitoring systems. Conventional methods like electrical resistivity or strain measurements using optical fibers are already in use. This study investigates the possibility of using various X-ray techniques to increase the reliability and significance of NDT and their applicability to in-service testing. Conventional film radiography is the most common technique; however, even after image enhancement of the digitized film, this technique lacks contrast sensitivity and dynamic range compared to digital detector array (DDA) radiography. The DDA radiography is a highly sensitive method; yet, the limitation is that it delivers 2D images of 3D objects. By the use of co-planar translational laminography the detectability of planar defects is superior to 2D methods due to multiple projection angles. Apart from this, it can be used on-site due to a rather simple setup and robust equipment. In this work two photon counting detectors (PCD) with different sensor materials (Si and CdTe) were used. The results show that the resolution and defect recognition is lower in case of DDA radiography and laminography using PCDs compared to high-resolution computed tomography. However, the DDA radiography and laminography are sensitive enough to both fiber breakage and delaminations and can be significantly advantageous in terms of measurement time and adaptability for on-site monitoring.

42 ENGINEERING↗

N -Arylimide Molecular Balances: A Comprehensive Platform for Studying Aromatic Interactions in Solution

Noncovalent interactions of aromatic surfaces play a key role in many biological processes and in determining the properties and utility of synthetic materials, sensors, and catalysts. However, the study of aromatic interactions has been challenging because these interactions are usually very weak and their trends are modulated by many factors such as structural, electronic, steric, and solvent effects. Recently, N-arylimide molecular balances have emerged as highly versatile and effective platforms for studying aromatic interactions in solution. These molecular balances can accurately measure weak noncovalent interactions in solution via their influence on the folded–unfolded conformational equilibrium. The structure (i.e., size, shape, π-conjugation, and substitution) and nature (i.e., element, charge, and polarity) of the π-surfaces and interacting groups can be readily varied, enabling the study of a wide range of aromatic interactions. These include aromatic stacking, heterocyclic aromatic stacking, and alkyl–π, chalcogen–π, silver–π, halogen–π, substituent–π, and solvent–π interactions. The ability to measure a diverse array of aromatic interactions within a single model system provides a unique perspective and insights as the interaction energies, stability trends, and solvent effects for different types of interactions can be directly compared. Some broad conclusions that have emerged from this comprehensive analysis include: (1) The strongest aromatic interactions involve groups with positive charges such as pyridinium and metal ions which interact with the electrostatically negative π-face of the aromatic surface via cation–π or metal–π interactions. Attractive electrostatic interactions can also form between aromatic surfaces and groups with partial positive charges. (2) Electrostatic interactions involving aromatic surfaces can be switched from repulsive to attractive using electron-withdrawing substituents or heterocycles. These electrostatic trends appear to span many types of aromatic interactions involving a polar group interacting with a π-surface such as halogen–π, chalcogen–π, and carbonyl–π. (3) Nonpolar groups form weak but measurable stabilizing interactions with aromatic surfaces in organic solvents due to favorable dispersion and/or solvophobic effects. Furthermore, a good predictor of the interaction strength is provided by the change in solvent-accessible surface area. (4) Solvent effects modulate the aromatic interactions in the forms of solvophobic effects and competitive solvation, which can be modeled using solvent cohesion density and specific solvent–solute interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-Temperature Synthesis of Tunable Mesoporous Crystalline Transition Metal Oxides and Applications as Au Catalyst Supports

Mesoporous transition metal oxides are of great potential as catalyst supports, shape-selective catalysts, photocatalysts, and sensor materials. Previously stable crystalline mesoporous oxides were mostly obtained by thermally induced crystallization or by segregating the nanocrystals with an amorphous phase. Here we report a novel direct approach to crystalline mesoporous frameworks via the spontaneous growth and assembly of transition metal oxide nanocrystals (i.e., rutile TiO2, fluorite CeO2, cassiterite SnO2, and anatase SnxTi1-xO2) by oxidative hydrolysis and condensation in the presence of anionic surfactants. The influences of synthesis time, surfactants with different chain lengths, concentrations of the oxidant (i.e., hydrogen peroxide), and synthesis temperatures on the composition and morphologies of the resulting materials were investigated by X-ray diffraction (XRD), N2-sorption, transmission electron microscopy (TEM), selected area electron diffraction (SAED), scanning electron microscopy (SEM), and X-ray photoelectron spectroscopy (XPS). A mechanism for the templated synthesis of crystalline mesoporous metal oxides was tentatively proposed. To demonstrate the catalytic applications of these materials, gold nanoparticles were loaded on mesoporous rutile TiO2 and fluorite CeO2 supports, and their catalytic performance in CO oxidation and water-gas shift was surveyed. Au nanoparticles supported on the mesoporous crystalline metal oxides exhibit higher reactivity and excellent on-stream stability towards CO oxidation and water-gas shift reaction compared with commercial TiO2 and CeO2.

08 HYDROGEN↗

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

Shakeup and shakeoff spectra in the electron capture decay of atomic 7 Be

The most stringent laboratory-based experimental limits on the existence of submegaelectronvolt sterile neutrinos are currently set by decay spectroscopy of radioactive 7 Be embedded into superconducting sensors. The systematic uncertainties are dominated by the modeling of the electron shakeup and shakeoff spectra that are not based on state-of-the-art atomic theory and do not include electron correlations or relativistic effects. We have used the multiconfiguration Dirac-Fock formalism to obtain correlated wave functions ab initio and compute all single and double shake processes in the electron capture decay of atomic 7 Be . The simulations can explain some but not all of the observed spectral features, likely because the wave functions are modified by the Ta sensor material that the 7 Be is embedded into. The new models also show that the 𝐿/𝐾 electron capture ratio of 7 Be in Ta has previously been slightly underestimated revising the previous value of 0.070(7) to a new value of 0.0756(20).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Aluminum-Based Superconducting Tunnel Junction Sensors for Nuclear Recoil Spectroscopy

The BeEST experiment is searching for sub-MeV sterile neutrinos by measuring nuclear recoil energies from the decay of 7 Be implanted into superconducting tunnel junction (STJ) sensors. The recoil spectra are affected by interactions between the radioactive implants and the sensor materials. We are therefore developing aluminum-based STJs (Al-STJs) as an alternative to existing tantalum devices (Ta-STJs) to investigate how to separate material effects in the recoil spectrum from potential signatures of physics beyond the Standard Model. Three iterations of Al-STJs were fabricated. The first had electrode thicknesses similar to existing Ta-STJs. They had low responsivity and reduced resolution, but were used successfully to measure 7 Be nuclear recoil spectra. The second iteration had STJs suspended on thin SiN membranes by backside etching. These devices had low leakage current, but also low yield. The final iteration was not backside etched, and the Al-STJs had thinner electrodes and thinner tunnel barriers to increase signal amplitudes. These devices achieved 2.96 eV FWHM energy resolution at 50 eV using a pulsed 355 nm (~3.5 eV) laser. These results establish Al-STJs as viable detectors for systematic material studies in the BeEST experiment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of Single Crystal Chemical Vapor Deposition Diamonds for Detector Applications

With the LHC upgrades in 2013, and further LHC upgrades scheduled in 2018, most LHC experiments are planning for detector upgrades which require more radiation hard technologies than presently available. At present all LHC experiments now have some form of diamond detector. As a result Chemical Vapor Deposition (CVD) diamond has now been used extensively in beam conditions monitors as the innermost detectors in the highest radiation areas of all LHC experiments. Moreover CVD diamond is now being discussed as an alternative sensor material for tracking very close to the interaction region of the HL-LHC where the most extreme radiation conditions will exist.

36 MATERIALS SCIENCE↗

Accelerometer Modeling in the State-Space

Generically, accelerometers are sensors that measure the accelerating force applied to an object. Their operation is based on a simple mechanical system and D’Alembert’s force principle along with Newton’s laws of motion. This device is typically mounted to the body of the test object under investigation that is subjected to an accelerating force. The displacement of the seismic or “proof” mass due to the acceleration is sensed by an embedded component from which the acceleration is determined. Interestingly enough, the resulting the resulting mathematical relations governing the dynamical motion is based on the underlying physics, sensor materials, geometry and fabrication. Mathematically, the various designs satisfy the underlying Newtonian equations of motion, but their type and performance differ significantly.

42 ENGINEERING↗

Assessment of Acoustic Sensor Application to Structural Health Monitoring of Reactor Components

The objectives of SHM of advanced fission reactors include the following: (1) Maintain safe, reliable, and efficient operation of structures, systems, and components in accordance with design intent; (3) Reduce cost; (4) Improve the comprehensive life management of structures, systems, and components; and (5) Extend the operational life of a power system through retirement for cause. Advanced reactor designs currently being considered are expected to operate at higher temperatures than light water-cooled reactors and to support missions beyond baseload electricity generation. Methods to monitor and detect for these mechanisms will require structural health monitoring (SHM) techniques, with ultrasonic methods an ideal candidate given their widespread use for NDE. This document summarized the state of technology for ultrasonic technologies, as part of an assessment of technology gaps and needed research. The great majority of sensor development to date addresses elevated temperatures and radiation tolerance, and more work is needed in both areas. Little data exists regarding corrosion effects of advanced coolants on sensor materials and couplants. Of high importance is the need for ARDs and regulatory bodies to engage and define what level of SHM is needed for autonomous or semi-autonomous control of reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗