Search NASA⌕ Search

SEARCH · Search NASA

Results for “materials imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Wide-angle imaging system with fiberoptic components providing angle-dependent virtual material stops

A strip imaging wide angle optical system is provided. The optical system is provided with a 'virtual' material stop to avoid aberrational effects inherent in wide angle optical systems. The optical system includes a spherical mirror section for receiving light from a 180 deg strip or arc of a target image. Light received by the spherical mirror section is reflected to a frustoconical mirror section for subsequent rereflection to a row of optical fibers. Each optical fiber transmits a portion of the received light to a detector. The optical system exploits the narrow cone of acceptance associated with optical fibers to substantially eliminate vignetting effects inherent in wide angle systems. Further, the optical system exploits the narrow cone of acceptance of the optical fibers to substantially limit spherical aberration. The optical system is ideally suited for any application wherein a 180 deg strip image need be detected, and is particularly well adapted for use in hostile environments such as in planetary exploration.

Vaughan, Arthur H.↗

The Design of Relativistic Ultrafast Electron Diffraction and Imaging (RUEDI) Facility for Materials in Extremes

Materials in extreme conditions in terms of temperature and pressure are of great interest where novel phenomena are expected for new science and materials design. A wide range of materials are of interest, including warm dense matter, particulate materials, liquid materials, fusion materials and geophysical materials. Their environments also range from liquid phase, gas phase and cryogenic temperatures. Here, the conditions often correspond to the level of the interiors of planets or stars. Such conditions are, however, typically not available in the laboratory. In addition, novel phenomena exist as transition structures that occur at an extremely short time scale in the harsh environments, which are often difficult to be modelled.

36 MATERIALS SCIENCE↗

In-situ Imaging of Pyrolyzing Aerospace Materials

Tracking morphological changes of materials during heating is crucial to understand its response in fire protection, biofuel production, thermal protection systems (TPS) for hypersonic flight. As materials are heated, they undergo physical and chemical changes due to water loss, stretching or shrinking, pyrolysis and chemical reactions in the ambient environment. The effects of these changes can have a profound impact on the material’s performance, indicated by changes in on the porosity and volume. While materials such as wood shrink as they pyrolyze and lose mass, others swell due to their inherent characteristics when exposed to heat [1]. This study focuses on experiments conducted at the Advanced Light Source (ALS) beamline 8.3.2, where in situ micro-computed tomography (µ-CT) is performed on materials as they are being pyrolyzed. Through in situ µ-CT, the change in total volume and porosity can be obtained in real-time, allowing for better understanding of the underlying thermophysical and chemical processes as a function of temperature. This study also focuses on the implementation of the Porous Microstructure Analysis software (PuMA) [2] to obtain thermal conductivity, permeability, and other properties of the material from the 3D tomographies. The information gained from these tomographies will supplement microscale model development of material morphological change and will aid macroscale modeling for high-temperature applications. For this study, Room Temperature Vulcanizing silicone (RTV) [3-5] is heated from room temperature to 1000°C using an infrared lamp heating system, and tomographies are continuously collected as the sample is heated. The tomographies are then segmented to obtain solid and void phases, from which estimates of pore size, porosity and total volume are extracted as a function of temperature. PuMA is deployed on the segmented tomographies to obtain thermal conductivity, permeability, and other properties as a function of temperature. Preliminary results show that RTV first intumesces (swells) as pyrolysis begins, due to build-up of pyrolysis gases in closed pores, and then shrinks significantly as more open pores are formed and the pyrolysis gases outgas. Pore network visualization of the tomographies using OpenPNM [6] showed the increase in pore connectivity with increase in temperature. Future work will focus on using PuMA to obtain macroscopic properties of RTV as a function of temperature.

Tomography↗

(U) Endpoint Energy and Scintillator Geometry Effects on the Swank Factor, Quantum Efficiency, and DQE(0) for High-Energy Radiography

High-energy radiography is used to image imploding materials to better understand weapon design and performance. The Enhanced Capabilities for Subcritical Experiments (ECSE) is a new facility proposal that aims to collect radiographic images of nuclear material. As part of the facility design, we aim to optimize data quality and radiographic performance by investigating different detector designs. We addressed design decisions by simulating different scintillator designs using M CNP6 and calculated the quantum efficiency, Swank factor, and detective quantum efficiency at zero-frequency (DQE(O)). First, we investigated the effects of the x-ray endpoint energy on the detector response. We generated three x-ray spectra with endpoint energies of 20 MeV, 22 MeV, and 24 MeV. The three raw spectra were filtered using the Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) line-of-sight materials along with 1) flat field filtration using 7 cm tungsten alloy in the bullnose and 2) an FTO with 4 plates. The scatter-to-direct radiation ratio was much larger for FTO with 4 plates (50-60%) compared to the flat field with 7 cm of bullnose material (8%). We used these filtered spectra to calculate the detector response for the original DARHT segmented scintillator design. We found that the endpoint energy and filtration had a negligible effect on the detector response. The quantum efficiency was 0.63, the Swank factor was 0.84, and the DQE(O) was 0.53 for all six spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhanced material identification via momentum-integrated muon scattering tomography

Cosmic ray muons, originating from interactions in the upper atmosphere, possess high energy and unique penetrative capabilities suitable for non-traditional radiographic inspection. This study explores their application in various fields such as nuclear fuel cask monitoring, nuclear reactor imaging, and archaeology, leveraging the principle of multiple Coulomb scattering for imaging dense materials. While muon scattering tomography has shown promise, accurately measuring muon momentum remains challenging. This research introduces the Momentum Integrated Point-of-Closest Approach (mPoCA) algorithm, integrating muon momentum data into the traditional Point-of-Closest Approach (PoCA) framework. Utilizing the Cherenkov muon spectrometer, renowned for precise muon momentum estimation, the mPoCA algorithm offers a novel imaging approach. Simulations conducted with GEANT4 evaluate the mPoCA algorithm’s performance against the standard PoCA method, demonstrating superior image resolution and enhanced material identification capabilities, particularly in distinguishing materials like uranium and lead. These findings underscore the potential of the mPoCA algorithm for advancing muon scattering tomography applications.

36 MATERIALS SCIENCE↗

X-ray computed tomography-based porosity analysis: Algorithms and application for porous woody biomass

The properties of lignocellulosic biomass, such as bulk physical, thermal, and mechanical properties, as well as the mobility of enzymes or catalysts, are largely affected by porosity, pore structures, and pore size distribution. While X-ray computed tomography (CT) has been introduced to effectively produce 3D volumetric images of material microstructure, a quantitative porosity analysis from the 3D images has never been done. This work introduces a first-of-its-kind X-ray CT-based quantitative porosity analysis method and applies the developed toolkit to characterize the internal porosity distribution of loblolly pine. A sample loblolly pine chip was scanned by a nano-resolution X-ray CT system and digitally reconstructed after a sequence of image processing operations. Here, a comprehensive porosity analysis was then performed to quantify the envelope porosity, the spatial distribution of local porosity, and the directional porosity. Solutions to the various challenges in image processing, porosity calculation, and large data handling are provided.

42 ENGINEERING↗

Thermographic imaging for high-temperature composite materials: A defect detection study

The ability of a thermographic imaging technique for detecting flat-bottom hole defects of various diameters and depths was evaluated in four composite systems (two types of ceramic matrix composites, one metal matrix composite, and one polymer matrix composite) of interest as high-temperature structural materials. The holes ranged from 1 to 13 mm in diameter and 0.1 to 2.5 mm in depth in samples approximately 2-3 mm thick. The thermographic imaging system utilized a scanning mirror optical system and infrared (IR) focusing lens in conjunction with a mercury cadmium telluride infrared detector element to obtain high resolution infrared images. High intensity flash lamps located on the same side as the infrared camera were used to heat the samples. After heating, up to 30 images were sequentially acquired at 70-150 msec intervals. Limits of detectability based on depth and diameter of the flat-bottom holes were defined for each composite material. Ultrasonic and radiographic images of the samples were obtained and compared with the thermographic images.

Roth, Don J.↗

Quantitative Holdup Determinations Using Coded-Aperture Gamma-Ray Imaging

Passive gamma-ray imaging can be used to create images of distributed nuclear materials. Inherently quantitative, the images provide a means to directly determine the amount of nuclear material in the imager’s field of view. However, to take advantage of quantitative imaging, one must correct for changes to the imager’s efficiency across the image. This paper presents work on detailed calibration of a coded-aperture imager based on a portable, mechanically cooled, high-purity germanium detector. This enables the use of gamma-ray imaging as a tool to determine nuclear holdup. By applying the calibrations to images of small amounts of distributed 235U, quantity estimates within a few percent of the actual amounts present were obtained, validating the approach.

Ziock, Klaus-Peter↗

Localization and coherent imaging of hidden moving objects using laser speckle

Imaging and sensing of moving objects through opaque scattering media is a challenging but important problem in a variety of applications, including environmental sensing, biomedical imaging, and material inspection. We have previously demonstrated a technique to coherently image a moving object through thick, heavily scattering random media using correlations of speckle images as a function of the object’s spatial translation. Here, we demonstrate that this technique can be combined with localization to achieve imaging without prior knowledge of the object’s motion, greatly extending the application domain. This method is effective beyond the thin or weakly scattering regime and, rather than motion being deleterious, exploits the information available when the hidden object is moving, as could be the case in a cluttered terrestrial environment or through substantial levels of biological tissue scatter.

Hastings, Ryan L. (ORCID:0009000095977807)↗

Energy shadowing correction of ultrasonic pulse-echo records by digital signal processing

Attention is given to a numerical algorithm that, via signal processing, enables the dynamic correction of the shadowing effect of reflections on ultrasonic displays. The algorithm was applied to experimental data from graphite-epoxy composite material immersed in a water bath. It is concluded that images of material defects with the shadowing corrections allow for a more quantitative interpretation of the material state. It is noted that the proposed algorithm is fast and simple enough to be adopted for real time applications in industry.

Kishoni, D.↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics FY2022 Project Report

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques. In this first year of the project, all uranium oxide samples were synthesized and characterized using conventional analyses by the analytical chemistry laboratory. Conventional analysis methods included powder x-ray diffraction, scanning electron microscopy, impurity analysis via inductively coupled plasma mass spectrometry, and infrared spectroscopy. Impurity analysis shows a drop in boron content from UO 3 to the lowest U 3 O 8 calcination temperature, but otherwise no appreciable difference in any sample. Analysis of diffraction data shows a flip of peaks from UO 3 dominated for the 600 °C calcined sample to U 3 O 8 dominated at 700 °C and 800 °C. Analysis of scanning electron microscopy images shows that with increased calcination temperature the size distribution of particles seems to increase and broaden. Both of these last findings are in line with previously published data, though this work used significantly fewer particles to simply show similar trends instead of getting truly quantitative particle analysis. Infrared analysis similarly shows ingrowth of U 3 O 8 as calcination temperature is increased, along with depression of peaks associated with UO 3 and water. Samples were prepared for analysis at the Advanced Photon Source at beamline 1-ID. It is anticipated that analysis will occur in November of 2022. AI/ML techniques to de-noise data coming out of 1-ID during the analyses was also developed during this time using previously gathered data. Preliminary results using a self-supervision technique called Noise2Selfshow good de-noising of data. Once the uranium oxide samples are analyzed, real data will be used to test the de-noising and other AI/ML techniques that may be developed in the second year of the project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics (FY23 Project Report)

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques.

36 MATERIALS SCIENCE↗

X-Ray Imaging Applied to Problems in Planetary Materials

Real-time radiography (X-ray imaging) can be a useful tool for tasks such as (1) the non-destructive, preliminary examination of opaque samples and (2) optimizing how to section opaque samples for more traditional microscopy and chemical analysis.

Jurewicz, A. J. G.↗