Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Heat treatment study 2

The microstructural variations in nickel based superalloys that result from modifications in processing were examined. These superalloys include MAR-M246(HF) and PWA1480. Alternate heat treatments for equiaxed as-cast specimens were studied and a sample matrix of 42 variations in the heat treatments were processed, as well as different directional solidification parameters. Variation in temperature and times for both solution and aging were performed. Photomicrographs were made of the microstructure and volume fraction analysis of primary gamma-prime and aged gamma-prime precipitates were performed. The results of the heat treatment, cooling rate, and directional solidification experiments are discussed.

Workman, Gary L.↗

Ar-39-Ar-40 of achondrites: Evidence for a lunar-like cataclysm

The observation that the K-Ar, Pb-Pb, and Rb-Sr ages of a significant number of lunar highland rocks were reset in the interval of 4.1-3.8 Ga ago led to the concept of a cataclysmic bombardment of the moon during this period. An important consideration for understanding the early bombardment history of the solar system, including the moon, is whether evidence also exists in meteorites for resetting of radiometric ages by cataclysmic bombardment of their parent bodies. A comparison of Ar-39-Ar-40 ages of achondritic meteorites with ages of lunar highland rocks should help elucidate the nature of the early bombardment of the solar system. We are participating in various consortia studies of primarily Antarctic eucrites and howardites for which we measured Ar-39-Ar-40 ages of various clasts and matrix samples. The results of these studies are presented.

Bogard, D. D.↗

Pulsed single-blow regenerator testing

A pulsed single-blow method has been developed for testing of Stirling regenerator materials performance. The method uses a tubular flow arrangement with a steady gas flow passing through a regenerator matrix sample that packs the flow channel for a short distance. A wire grid heater spanning the gas flow channel is used to heat a plug of gas by approximately 2 K for approximately 350 ms. Foil thermocouples monitor the gas temperature entering and leaving the sample. Data analysis based on a 1D incompressible-flow thermal model allows the extraction of Stanton number. A figure of merit involving heat transfer and pressure drop is used to present results for steel screens and steel felt. The observations show a lower figure of merit for the materials tested than is expected based on correlations obtained by other methods.

Oldson, J. C.↗

Exposure History of Separated Phases from the Kapoeta Meteorite

Cosmogenic Be-10, Al-26, Cl-36, and Mn-53 were measured in clasts and matrix samples from Kapoeta. The radionuclide data are consistent with a single stage exposure lasting approximately 3 Ma. These results are not consistent with exposure ages based on cosmogenic Ne-21.

Caffee, M. W.↗

Modeling the Atmospheric Phase Effects of a Digital Antenna Array Communications System

In an antenna array system such as that used in the Deep Space Network (DSN) for satellite communication, it is often necessary to account for the effects due to the atmosphere. Typically, the atmosphere induces amplitude and phase fluctuations on the transmitted downlink signal that invalidate the assumed stationarity of the signal model. The degree to which these perturbations affect the stationarity of the model depends both on parameters of the atmosphere, including wind speed and turbulence strength, and on parameters of the communication system, such as the sampling rate used. In this article, we focus on modeling the atmospheric phase fluctuations in a digital antenna array communications system. Based on a continuous-time statistical model for the atmospheric phase effects, we show how to obtain a related discrete-time model based on sampling the continuous-time process. The effects of the nonstationarity of the resulting signal model are investigated using the sample matrix inversion (SMI) algorithm for minimum mean-squared error (MMSE) equalization of the received signal

Tkacenko, A.↗

Requirements for Portable Instrument Suites during Human Scientific Exploration of Mars

Human explorers on the surface of Mars will have access to a far wider array of scientific tools than previous crewed planetary exploration missions, but not every tool will be compatible with the restrictions of this exploration. Spectrometers on flyby, orbital, and landed missions are currently used to determine the composition and mineralogy of geological materials of various types and sizes, from small fragments to celestial bodies in the solar system. Handheld spectrometers that are capable of in situ analyses are already used for geological exploration on Earth; however, their usefulness for human exploration missions and how data from multiple handheld instruments could be combined to enhance scientific return must be further evaluated. As part of the Biologic Analog Science Associated with Lava Terrains (BASALT) research project, we incorporated two handheld instruments, a visible-near infrared spectrometer and an X-Ray Fluorescence spectrometer, into simulated Mars exploration missions conducted on basaltic terrains in Idaho and Hawai'i. To understand the data quality provided by these handheld spectrometers, we evaluated their performance under varying conditions of measurement time, distance, angle, atmosphere, and sample matrix, and we compared data quality between handheld instruments and laboratory techniques. Here, we summarize these findings, provide guidelines and requirements on how to effectively incorporate these instruments into human exploration missions to Mars, and posit that future iterations of these instruments will be beneficial for enhancing science returned from human exploration missions.

Alexander Sehlke↗

Trace Element and Isotopic Evidence for Bennu's Primitive Provenance

The delivery of material from asteroid (101955) Bennu by NASA’s OSIRIS-REx mission provides the opportunity to investigate some of the most pristine material from the early Solar System [1]. Our team at Lawrence LivermoreNational Laboratory (LLNL) utilized the equivalent of 5.0 mg from Bennu sampleOREX-803015-100 to quantify the major and trace element contents and investigate major element isotopics (Ca, Ti, Cr, Fe, and Ni). Our 5.0 mg aliquot ofOREX-803015-100 was a subsample of dissolved homogenized material representing 20.66 mg [2]. A separate 5.0 mg aliquot was sent to ETH Zürich and is discussed in a companion abstract [3]. Before any chemical separation on our 5.0 mg aliquot, the equivalent of 0.5 mg was removed and analyzed for elemental abundances at LLNL using a ThermoScientific Element XR. Our data agree exceptionally well with those reported by[2], showing that Bennu is primitive and compositionally similar to CI chondrites, Ryugu [4], and the solar photosphere [5]. The remaining ~4.5 mg underwent purification procedures to chemically isolate and purify Ca, Ti, Cr, Fe, and Ni from one another and the sample matrix. Their isotopic compositions were measured on either the Triton TIMS (Ca) at JohnsonSpace Center in Houston, Neoma MC-ICPMS (Ti, Cr) at LLNL, or the Neptune MC-ICPMS (Fe, Ni) at LLNL. Results from the Ca, Ti, Cr, Fe, and Ni isotopic compositions suggest that Bennu is closely related to CI chondrites—consistent with conclusions from elemental composition [2] and oxygen isotopics [6]reported for Bennu. The major element isotope compositions that we will present demonstrate that Bennu likely formed in a similar region of the SolarSystem as CI chondrites and potentially at a similar time of Solar System evolution.

Greg Brennecka↗

Survey of Collection Media for Environmental Sampling

A study was undertaken to survey other potential sampling media that may be more effective in collecting nuclear materials and at the same time contain less uranium. Approximately 40 natural and synthetic fiber wipers were tested. A few were coated with complexants and/or solvents during the manufacturing process. Adhesives and tapes were also included. The relative merits of each sampling matrix were reviewed on the basis of: 1) efficiency in collecting uranium from surfaces, 2) the ease by which the wiper fabric is separated from the nuclear components, 3) latent uranium background of the wiper, 4) the impact that any dissolved swipe components might have on the chromatographic recovery of uranium, and finally, 5) the presence of any isobaric interferences that the dissolved swipe might contribute to the background during MS analysis. Results from this survey are compared to the standard cotton swipe and recommendations presented for the most promising candidates for further consideration.

Fontenot, Hunter↗

Cyclic Oxidation of FeCrAlY/Al2O3 Composites

Three-ply FeCrAlY/Al2O3 composites and FeCrAlY matrix-only samples were cyclically oxidized at 1000 C and 1100 C for up to 1000 1-hr cycles. Fiber ends were exposed at the ends of the composite samples. Following cyclic oxidation, cracks running parallel to and perpendicular to the fibers were observed on the large surface of the composite. In addition, there was evidence of increased scale damage and spallation around the exposed fiber ends, particularly around the middle ply fibers. This damage was more pronounced at the higher temperature. The exposed fiber ends showed cracking between fibers in the outer plies, occasionally with Fe and Cr-rich oxides growing out of the cracks. Large gaps developed at the fiber/matrix interface around many of the fibers, especially those in the outer plies. Oxygen penetrated many of these gaps resulting in significant oxide formation at the fiber/matrix interface far within the composite sample. Around several fibers, the matrix was also internally oxidized showing Al2O3 precipitates in a radial band around the fibers. The results show that these composites have poor cyclic oxidation resistance due to the CTE mismatch and inadequate fiber/matrix bond strength at temperatures of 1000 C and above.

Nesbitt, James A.↗

Report for Batch Leach Analyses on Sediments at 100-HR-3 Operable Unit, Boreholes C7620, C7621, C7622, C7623, C7626, C7627, C7628, C7629, C7630, and C7866

This is a revision to a previously released report. This revision contains additional analytical results for the sample with HEIS number B2H4X7. Between November 4, 2010 and October 26, 2011 sediment samples were received from 100-HR-3 Operable Unit for geochemical studies. The analyses for this project were performed at the 331 building located in the 300 Area of the Hanford Site. The analyses were performed according to Pacific Northwest National Laboratory (PNNL) approved procedures and/or nationally recognized test procedures. The data sets include the sample identification numbers, analytical results, estimated quantification limits (EQL), and quality control data. The preparatory and analytical quality control requirements, calibration requirements, acceptance criteria, and failure actions are defined in the on-line QA plan 'Conducting Analytical Work in Support of Regulatory Programs' (CAW). This QA plan implements the Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD) for PNNL. Samples were received with a chain of custody (COC) and were analyzed according to the sample identification numbers supplied by the client. All Samples were refrigerated upon receipt until prepared for analysis. All samples were received with custody seals intact unless noted in the Case Narrative. Holding time is defined as the time from sample preparation to the time of analyses. The prescribed holding times were met for all analytes unless noted in the Case Narrative. All reported analytical results meet the requirements of the CAW or client specified SOW unless noted in the case narrative. Due to the requirements of the statement of work and sampling events in the field, the 28 day and the 48 hr requirements cannot be met. The statement of work requires samples to be selected at the completion of the borehole. It is not always possible to complete a borehole and have the samples shipped to the laboratory within the hold time requirements. Duplicate RPD for Uranium 238 (38.9%) was above the acceptance limit (35) in 1E05003-DUP1 for ICPMS-Tc-U-WE The sample result is less than 10 times the detection limits. Duplicate recoveries are not applicable to this analyte. Duplicate RPD for Silver 107 (68.2%) was above the acceptance limit (35) in 2C06004-DUP1 for ICPMS-RCRA-AE The sample result is less than 10 times the detection limits. Duplicate recoveries are not applicable to this analyte. Matrix Spike Recovery for Chromium, Hexavalent (48.8%) was outside acceptance limits (75-125) in 1E23001-MS1 for Hexavalent Chromium/Soil. Potential Matrix interference. Sample results associated with this batch are below the EQL. There should be no impact to the data as reported. Matrix Spike Recovery for Chromium, Hexavalent (50.2%) was outside acceptance limits (75-125) in 2B22010-MS1 for Hexavalent Chromium/Soil. Potential Matrix interference. Sample results associated with this batch are below the EQL. There should be no impact to the data as reported.

54 ENVIRONMENTAL SCIENCES↗

Characterization of actinide abundances and isotopic compositions by HR-ICP-MS. Part 2: Results from actinide doping studies

Previously, we presented actinide isotopic and elemental data from fallout melt glass that was measured using high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Direct comparison between these measurements and ‘gold standard’ data obtained by multi-collector ICP-MS showed broad overlap, indicating that HR-ICP-MS is a potentially valuable technique for producing actinide elemental and isotopic data on a relatively rapid timescale. To test the usefulness of this technique further, we doped varying amounts of uranium certified reference materials (CRMs) into a rhyolitic rock standard to establish the effects of uranium concentration and isotopic composition on the accuracy of uranium isotopic analyses by HR-ICP-MS. This also enabled us to quantify peak tailing effects from 238 U on the measurement of 239 Pu and 237 Np, which in turn allows us to constrain correction factors based on measured 237 Np/ 238 U and 239 Pu/ 238 U ratios. A second doping study involved the addition of a mixed actinide standard into three samples with different matrix compositions (termed soil, city, and seawater) to assess whether sample chemistry affects the accuracy and precision of these analyses. Results suggest that this is not the case. Systematic offsets were not observed in elemental or isotopic data derived from the three matrix samples. Results indicate that useful actinide isotopic data can be obtained from whole rock solutions by HR-ICP-MS. Our findings also have implications for solid sampling techniques such as laser ablation ICP-MS, which do not require sample dissolution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Geochemical Comparison of Four Cores from the Manson Impact Structure

Concentrations of 33 elements were determined in relatively unaltered, matrix-rich samples of impact breccia at approximately 3-m-depth intervals in the M-1 core from the Manson impact structure, Iowa. In addition, 46 matrix-rich samples from visibly altered regions of the M-7, M-8, and M-10 cores were studied, along with 42 small clasts from all four cores. Major element compositions were determined for a subset of impact breccias from the M-1 core, including matrix-rich impact-melt breccia. Major- and trace-element compositions were also determined for a suite of likely target rocks. In the M-1 core, different breccia units identified from lithologic examination of cores are compositionally distinct. There is a sharp compositional discontinuity at the boundary between the Keweenawan-shale-clast breccia and the underlying unit of impact-melt breccia (IMB) for most elements, suggesting minimal physical mixing between the two units during emplacement. Samples from the 40-m-thick IMB (M-1) are all similar to each other in composition, although there are slight increases in concentration with depth for those elements that have high concentrations in the underlying fragmental-matrix suevite breccia (SB) (e.g., Na, Ca, Fe, Sc), presumably as a result of greater clast proportions at the bottom margin of the unit of impact-melt breccia. The high degree of compositional similarity we observe in the impact-melt breccias supports the interpretation that the matrix of this unit represents impact melt. That our analyses show such compositional similarity results in part from our technique for sampling these breccias: for each sample we analyzed a few small fragments (total mass: approximately 200 mg) selected to be relatively free of large clasts and visible signs of alteration instead of subsamples of powders prepared from a large mass of breccia. The mean composition of the matrix-rich part of impact-melt breccia from the M-1 core can be modeled as a mixture of approximately 35% shale and siltstone (Proterozoic "Red Clastics"), 23% granite, 40% hornblende-biotite gneiss, and a small component (less than 2%) of mafic-dike rocks.

Korotev, Randy L.↗

Texture analysis of AGR program matrix materials

We report the fuel form for high-temperature gas-cooled reactors consists of tristructural isotropic (TRISO) particles embedded in a matrix of graphite flake and carbonized resin. The process of overcoating particles prior to compacting yields a circumferential orientation of the graphite flake surrounding the TRISO particles, which is modified to varied extents when overcoated particles are pressed into the final fuel form. As graphite is highly anisotropic, the texture may impact the properties and performance of the fuel. Ellipsometry was used to measure the texture of the matrix for fueled compacts and unfueled “matrix-only” samples. Results indicated local texture related to the spherical particles in compacts associated with overcoating versus a more linear layered structure in “matrix-only” samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Vacuum compatible sample positioning device for matrix assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry imaging

The high mass accuracy and resolving power of Fourier transform ion cyclotron resonance mass spectrometers (FT-ICR MS) make them ideal mass detectors for mass spectrometry imaging (MSI), promising to provide unmatched molecular resolution capabilities. The intrinsic low tolerance of FT-ICR MS to RF interference, however, along with typically vertical positioning of the sample, and MSI acquisition speed requirements present numerous engineering challenges in creating robotics capable of achieving the spatial resolution to match. This work discusses a two-dimensional positioning stage designed to address these issues. The stage is capable of operating in {approx}1 x 10{sup -8} mbar vacuum. The range of motion is set to 100 mm x 100 mm to accommodate large samples, while the positioning accuracy is demonstrated to be less than 0.4 micron in both directions under vertical load over the entire range. This device was integrated into three different matrix assisted laser desorption/ionization (MALDI) FT-ICR instruments and showed no detectable RF noise. The ''oversampling'' MALDI-MSI experiments, under which the sample is completely ablated at each position, followed by the target movement of the distance smaller than the laser beam, conducted on the custom-built 7T FT-ICR MS demonstrate the stability and positional accuracy of the stage robotics which delivers high spatial resolution mass spectral images at a fraction of the laser spot diameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗