Effective conductivity of wire mesh reflectors for space deployable antenna systems

This report summarizes efforts to characterize the measurement of conductive mesh and smooth surfaces using proximity measurements for a dielectric resonator. The resonator operates in the HEM11 mode and is shown to have an evanescent field behavior in the vicinity of the sample surface, raising some question to the validity of measurements requiring near normal incidence on the material. In addition, the slow radial field decay outside of the dielectric resonator validates the sensitivity to the planar supporting structure and potential radiation effects. Though these concerns become apparent along with the sensitivity to the gap between the dielectric and the material surface, the basic concept of the material measurement using dielectric resonators has been verified for useful comparison of material surface properties. The properties, particularly loss, may be obtained by monitoring the resonant frequency along with the resonator quality factor (Q), 3 dB bandwidth, or the midband transmission amplitude. Comparison must be made to known materials to extract the desired data.

Davis, William A.↗

Material Identification From Radiographs Without Energy Resolution

We propose a method for performing material identification from radiographs without energy-resolved measurements. Material identification has a wide variety of applications, including in biomedical imaging, nondestructive testing, and security. While existing techniques for radiographic material identification make use of dual energy sources, energy-resolving detectors, or additional (e.g., neutron) measurements, such setups are not always practical— requiring additional hardware and complicating imaging. We tackle material identification without energy resolution, allowing standard X-ray systems to provide material identification information without requiring additional hardware. Assuming a setting where the geometry of each object in the scene is known and the materials come from a known set of possible materials, we pose the problem as a combinatorial optimization with a loss function that accounts for the presence of scatter and an unknown gain and propose a branch and bound algorithm to efficiently solve it. We present experiments on both synthetic data and real, experimental data with relevance to security applications— thick, dense objects imaged with MeV X-rays. We show that material identification can be efficient and accurate, for example, in a scene with three shells (two copper, one aluminum), our algorithm ran in six minutes on a consumer-level laptop and identified the correct materials as being among the top 10 best matches out of 8,000 possibilities.

36 MATERIALS SCIENCE↗

In‐situ Analysis of Paste Properties in Resonant Acoustic Mixers for Quality Monitoring

Formulation control is key to achieving consistent target properties of energetic materials, as feedstock variations and slight deviations in the ratios of different ingredients can have major effects on final product properties, particularly in dense pastes with high particle loading >65 vol.%. In large‐scale operations, it is imperative to either correct or remove batches of material that perform outside baseline property specifications as early as possible to avoid unnecessary processing of suboptimal material. Quality monitoring is the practice of measuring material properties during processing using process analytical technologies as opposed to only testing the properties of the final product; it is a key principle in the quality‐by‐design frameworks used for designing formulations and manufacturing processes. Herein, a process analytical technology method for correlating material properties of dense pastes directly after mixing in a Resonant Acoustic Mixer to motor data is developed and used to detect differences in the particle content of dense paste formulations. This method was also capable of detecting variations in powder feedstock properties, such as particle packing efficiency, and is sensitive enough to detect changes of 2 wt.% in the total solids content of the formulation. The techniques presented herein show excellent promise for use as a process analytical technology capable of quantifying formulation effects on material movement modes during resonant acoustic mixing.

Materials science↗

Effects of material inhomogeneities on ultrasonic measurements - The problem and a solution

Most ultrasonic measurements of materials involve the generation of an acoustic wave and the propagation of that wave from a transducer through a coupling medium to a specimen under test. After interacting with the specimen, the wave propagates through the coupling medium to a receiving transducer and is converted to an electrical signal. The information presented to the observer by the electrical signal depends on each element of the system. In this paper, the role that the receiving transducer plays in ultrasonic measurements is examined. The phase-sensitive nature of conventional receiving transducers has, for the most part, been neglected in nondestructive evaluations. This is shown to lead to significant data misinterpretation. A new acoustoelectric transducer (AET) has been developed which is phase insensitive. Comparative data obtained with both conventional and AET transducers are presented and discussed. The AET is shown to produce more accurate measurements for the cases investigated.

Heyman, J. S.↗

Goniometric and Polarized Imaging Spectroscopic Lab Measurements of Spacecraft Materials

To better characterize the spectral response of common spacecraft materials, the following laboratory measurements are presented to support the Space Situational Awareness community in the analysis of remotely sensed observational data. Of interest is classifying material reflective properties using directional reflectance spectroscopy and spatially resolved polarized imaging spectroscopy, allowing laboratory data to be applicable to ground-based optical telescope observations. The team acquired a typical CubeSat solar panel and a sample of multi-layer insulation (MLI) commonly used on spacecraft for initial measurements. The directional spectral data were collected at the Goniometer of the Rochester Institute of Technology (GRIT) laboratory with a lab and field goniometer incorporating two AnalyticalSpectral Device (ASD) spectrometers, a small Lab sphere integrating sphere also paired with an ASD spectrometer, and a Headwall micro-Hyperspec E-Series imaging spectrometer with an adjustable linear polarizer. The goniometer measures spectral bi-directional reflectance factor (BRF) data over a broad range from 350−2500 nm at 1 nm spacing with 3 nm spectral resolution in the visible and near infrared and 8 nm in the shortwave infrared. With the same spectral capabilities, the integrating sphere measures hemispherical-directional reflectance (HDR) in a 45◦-nadir configuration. The Headwall imager covers a spectral range from 400−1000 nm with 1.6 nm spectral resolution.Our initial BRF measurements show interference effects for both materials typically observed with thin films and high infrared reflectivity. In contrast, the interference effects are not present in the HDR measurements of the MLI likely due to the interference effects being averaged out over the reflecting hemisphere. Spatially resolved polarization ratio maps show variability across the materials due to the varying surface structure. We outline a plan for expanding our analysis to a broader range of materials to characterize their directional reflectance spectroscopy.

Chris H. Lee↗

Advances in optical property measurements of spacecraft materials

Some of the instruments and experimental approaches, used for measuring the optical properties of thermal control systems, are presented. The instruments' use in studies concerning the effects of combined contaminants and space environment on these materials, and in the qualification of hardware for spacecraft, are described. Instruments for measuring the solar absorptance and infrared emittance offer improved speed, accuracy and data handling. A transient method for directly measuring material infrared emittance is described. It is shown that oxygen exposure before measuring the solar absorptance should be avoided.

Smith, Charles A.↗

Reliability analysis of single crystal NiAl turbine blades

As part of a co-operative agreement with General Electric Aircraft Engines (GEAE), NASA LeRC is modifying and validating the Ceramic Analysis and Reliability Evaluation of Structures algorithm for use in design of components made of high strength NiAl based intermetallic materials. NiAl single crystal alloys are being actively investigated by GEAE as a replacement for Ni-based single crystal superalloys for use in high pressure turbine blades and vanes. The driving force for this research lies in the numerous property advantages offered by NiAl alloys over their superalloy counterparts. These include a reduction of density by as much as a third without significantly sacrificing strength, higher melting point, greater thermal conductivity, better oxidation resistance, and a better response to thermal barrier coatings. The current drawback to high strength NiAl single crystals is their limited ductility. Consequently, significant efforts including the work agreement with GEAE are underway to develop testing and design methodologies for these materials. The approach to validation and component analysis involves the following steps: determination of the statistical nature and source of fracture in a high strength, NiAl single crystal turbine blade material; measurement of the failure strength envelope of the material; coding of statistically based reliability models; verification of the code and model; and modeling of turbine blades and vanes for rig testing.

Salem, Jonathan↗

Speckle Pattern for Woven Softgood Habitats Photogrammetry Testing

Space habitation is becoming more accessible and commercially available which is driving the development and testing of inflatable softgoods habitats that can be both lighter and more volume-efficient than heritage metallic pressure vessels. Photogrammetry test methods are used on new materials and larger inflatable softgood test articles to measure material displacement and strain during pressurization. A speckle pattern must be applied to the surface of interest for testing when using photogrammetry which is typically a very labor and time intensive process. Two methods were tested as options for a faster and more effective application to hand painting and temporary tattoos, which are the current application methods for the structural/restraint layer. One approach was to mix a plastic additive with a matte clear coat to create a speckle pattern that could be applied to the article. The second method uses a speckle paint gun to speckle the article after a white base coat is applied. Both methods adhered well to the Kevlar test sample materials and showed up well when examined with photogrammetry cameras. On the woven test samples the additive in a clear coat method could be applied evenly as was the paint gun method.

Rylee Cardon↗

Speckle Pattern Application to Woven Softgoods

Space habitation is becoming more accessible and commercially available which is driving the development and testing of inflatable softgoods habitats that can be both lighter and more volume-efficient than heritage metallic pressure vessels. Photogrammetry test methods are used on new materials and larger inflatable softgood test articles to measure material displacement and strain during pressurization. A speckle pattern must be applied to the surface of interest for testing when using photogrammetry which is typically a very labor and time intensive process. Two methods were tested as options for a faster and more effective application to hand painting and temporary tattoos, which are the current application methods for the structural/restraint layer. One approach was to mix a plastic additive with a matte clear coat to create a speckle pattern that could be applied to the article. The second method uses a speckle paint gun to speckle the article after a white base coat is applied. Both methods adhered well to the Kevlar test sample materials and showed up well when examined with photogrammetry cameras. On the woven test samples the additive in a clear coat method could be applied evenly as was the paint gun method.

Rylee Cardon↗

Speckle Pattern Application to Woven Softgoods

Space habitation is becoming more accessible and commercially available which is driving the development and testing of inflatable softgoods habitats that can be both lighter and more volume-efficient than heritage metallic pressure vessels. Photogrammetry test methods are used on new materials and larger inflatable softgood test articles to measure material displacement and strain during pressurization. A speckle pattern must be applied to the surface of interest for testing when using photogrammetry which is typically a very labor and time intensive process. Two methods were tested as options for a faster and more effective application to hand painting and temporary tattoos, which are the current application methods for the structural/restraint layer. One approach was to mix a plastic additive with a matte clear coat to create a speckle pattern that could be applied to the article. The second method uses a speckle paint gun to speckle the article after a white base coat is applied. Both methods adhered well to the Kevlar test sample materials and showed up well when examined with photogrammetry cameras. On the woven test samples the additive in a clear coat method could be applied evenly as was the paint gun method.

Rylee Cardon↗

Using Digital Image Correlation for Material Testing at Cryogenic Temperatures

Recent efforts were made to parametrize an aluminum alloy at cryogenic temperatures to calibrate finite element models simulating material deformation. Digital image correlation (DIC) was used to measure material properties using front/back strains of specimens during tensile tests. Data acquired from DIC was compared to physical extensometer measurements. Two camera pairs (front and back) were mounted via aluminum extrusion to the exterior of an environmental chamber of a hydraulic test stand. Images were taken through single-pane optical glass windows of the environment chamber. Positive pressure bags encased the cameras, attaching to the perimeter of the glass to keep out moisture and prevent windows from frosting. Figure 1 shows the environmental setup and the camera setup during cryogenic testing. Some of the challenges during testing at cryogenic temperatures include the gaseous flow of liquid nitrogen in the optical path of the mounted cameras, frost buildup on the windows as seen in Figure 1b, and frost on the test coupon. The temperature gradient present during the introduction of liquid nitrogen into the chamber can increase the projection error of images captured of the specimen. Figure 2 shows the estimated projection error from DIC as a function of temperature during the cool down process. This presentation addresses some of the concerns and observations when using DIC for testing at cryogenic temperatures using methods of isolated camera system and techniques for maintaining the glass panel clear from frost.

Joseph Cochran↗

Laboratory investigations involving high-velocity oxygen atoms

Facilities for measuring material reactive characteristics have been under development for several years and span the atom energy range from thermal to 5 eV, the orbital collision energy. One of the high-atom energy facilities (The High Intensity/Energy Atomic Oxygen Source) capable of simulating the reactive part of LEO is described, along with results of beam characterization and preliminary material studies. The oxygen atom beam source was a continuous wave plasma produced by focusing a high-power CO2 laser through a lens system into a rare gas/molecular oxygen mixture chamber at elevated temperature. Material samples were exposed to the high velocity beam through an external feedthrough. The facility showed good stability in continued operation for more than 100 hours, producing fluences of 10 to the 21st to 10 to the 22nd atoms/sq cm. Reaction efficiencies and surface morphology have been measured for several materials at energies of 1.5 and 2.8 eV, matching with data generated from previous space flights. Activation energies for carbon and Kapton as measured in this facility were 800 cal/mole.

Leger, Lubert J.↗

Ellipsoidal-mirror reflectometer accurately measures infrared reflectance of materials

Reflectometer accurately measures the reflectance of specimens in the infrared beyond 2.5 microns and under geometric conditions approximating normal irradiation and hemispherical viewing. It includes an ellipsoidal mirror, a specially coated averaging sphere associated with a detector for minimizing spatial and angular sensitivity, and an incident flux chopper.

Dunn, S. T.↗

High-throughput micro-scale bandgap mapping for perovskite-inspired materials with complex composition space

Abstract To realize the full promise of high-throughput experimental workflows, the rate of sample synthesis must be matched by that of characterization. Of growing interest are contactless optical techniques that can rapidly measure material homogeneity and properties. Here, we present a hyperspectral imaging method to measure local optical bandgap distributions within samples, utilizing spatially-resolved reflectance spectra coupled with automated data analysis. We collect approximately one million optical bandgap data across the compositional space of Cs 3 (Bi x Sb 1-x ) 2 (Br y I 1-y ) 9 perovskite-inspired materials. Our results show non-monotonic bandgap variations (i.e., bandgap bowing) along six composition gradient sequences, in addition to identifying samples with multiple bandgaps in statistics. High-throughput transient absorption spectroscopy reveals that within these compositions, the depletion of the ground state carriers to excited states occurred at discrete energy levels with independent carrier dynamics, consistent with the bandgap observation and indicative of phase separation. This work demonstrates the potential for rapid optical measurements to assess material quality and homogeneity in a high-throughput experimental setting, supporting screening and recipe optimization of optoelectronic material candidates with desired carrier dynamics and optical properties.

Science & Technology - Other Topics↗

Design application and development of spacecraft in LEO utilizing LDEF results

In general, the results from the Long Duration Exposure Facility (LDEF) have provided much useful information on material sensitivity in the low-Earth orbit (LEO) environment. This is particularly true for selected materials such as thermal control coatings, composites, polymers, fasteners and solar cells. However, LDEF material sensitivity data for other materials like glasses, glass coatings, lubricants, adhesives and seal materials were limited. Some of this important LDEF material sensitivity data has not yet been addressed in detail at the LDEF meetings. The type of material information needed in the design and development of a new spacecraft in LEO depends to a large extent on program phase. In early program phases it is only necessary to have material sensitivity data to determine what materials may or may not work. Later program phases require details on the material strength, optical properties, and/or other long term survivability requirements for materials in LEO. Unfortunately, documentation of exposure results for many materials sensitivity experiments that flew on LDEF has not yet been summarized in a convenient form for use by multiple users. Documentation of this data in a form convenient for scientists, engineers as well as technicians remains a significant area of concern for the aerospace industry. Many of the material experiments that flew on LDEF were only designed to measure material sensitivity for one year in an LEO environment. However, some materials expected to survive one year simply did not survive the 5.8 years that LDEF eventually remained in orbit. Therefore the survivability of several materials in an LEO environment was determined by default. Most of the LDEF materials experiments were not designed to establish long term material survivability data. This long term material survivability data is particularly useful in later program phases of spacecraft development. The lack of more controlled materials experiments to determine long term material survivability was one of the major limitations of many LDEF experiments. The identified need for this critical information on the long term survivability offers a challenge to possible future LDEF type experiments.