Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Review of thermophysical property methods applied to fueled and un-fueled molten salts

Recent investigation into designs of molten salt reactors (MSR) requires accurate data of candidate salts. Review of the literature shows lacking thermophysical (TP) property data for coolants and fuel-bearing salts of Advanced High Temperature Reactors (AHTR). Measurement uncertainties of current data are even more deficient, and this affects ongoing research where MSR modeling and testing are being performed. Melting temperature, viscosity, density, specific heat capacity, and thermal and electrical conductivity measurements are often not arranged together or discussed in great detail, especially for fuel-bearing salts. Raw data from key findings spanning over 70 years for LiF, LiF-BeF 2 , LiF-NaF-KF, KCl-MgCl 2 , KF-ZrF 4 , and NaF-KF-MgF 2 have been organized and presented here. Brief description of methods used to obtain these results, in addition to the TP data of some of these salts as fuel carriers, has also been discussed. Thermal conductivity data are particularly weak due to older, high-error measurement techniques. More recent measurement systems to evaluate salt thermal conductivity show promise for obtaining consistent absolute values. This work concludes that measurement systems such as transient hot-wire method, forced Rayleigh scattering, and laser flash analysis provide the most promise to fill these data gaps and reduce current uncertainty in thermal conductivity measurements of both fueled and un-fueled molten salts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Non-contact based measurement of thin film coatings using eddy current measurements

When a time varying magnetic field attempts to penetrate a conductive surface, the surface will respond to that time varying field by the generation of circular currents around the flux lines. This effect is described by Faraday’s law of induction. An eddy current based measurement system attempts to discern the power loss incurred by these circulating currents within the conductive surface. The measurement system described here uses an Agilent E 4980A LCR meter to quantify the reaction of the film to the high frequency magnetic field lines which are forced into the film. The measurement metric is the meter’s interpretation of the power dissipation caused by the measured film. The meter is setup to use the Ls/Rs inductor model, and is run at 1 Mhz to bring the losses within the film as high as possible for sensitivity.

43 PARTICLE ACCELERATORS↗

Advanced Measurements for Resilient Integration of Inverter-Based Resources: PROGRESS MATRIX Final Report

As nearly every aspect of the electric power grid undergoes rapid change, measurement technologies that support grid operation and planning must evolve as well. The rapid large-scale deployment of inverter-based resources (IBRs) vital to achieving the nation’s clean energy goals has in some cases led to negative impacts on the reliability and security of the bulk power system (BPS). Advanced power system measurements, including synchronized phasor and waveform measurements, are key to making IBR integration secure and reliable. To this end, the Department of Energy (DOE) initiated the PROGRESS MATRIX project to develop advanced measurement capabilities and analytics that will accelerate adoption of IBRs while improving the reliability and resilience of the BPS. This report discusses the outcomes of the project, which was a joint effort between the Pacific Northwest National Laboratory (PNNL), Oak Ridge National Laboratory (ORNL), the National Renewable Energy Laboratory (NREL), and Lawrence Berkeley National Laboratory (LBNL). In the project’s first year, PNNL, NREL, and ORNL partnered with the Bonneville Power Administration (BPA), the Western Area Power Administration (WAPA), and Kauai Island Utility Cooperative (KIUC) to understand their existing measurement capabilities and the gaps limiting deployment of IBR-focused measurement systems and analytics. The other primary activity in the first year was deployment of GridSweep instruments, which provide unprecedented precision in waveform measurement while probing distribution systems. The instruments were deployed at Dominion Energy and the University of California, Riverside. In the project’s second year, the input from partner utilities and collected measurements were used to advance measurement capabilities. Twelve analytical methods spanning disturbance analysis, power plant evaluation, feeder evaluation, and modeling were developed. Two software tools were developed, one to analyze GridSweep measurements and another to automatically evaluate the control performance of power plants connected to the BPS. Testbeds at ORNL and NREL were augmented to better enable studies of IBR integration. The project culminated in demonstrations of these analytical methods, software tools, and testbeds, both in the field and in the laboratory. This report discusses these various accomplishments and documents the significant progress in developing advanced measurement capabilities to support the secure, reliable, and accelerated adoption of IBRs in the BPS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solving Optimal Power Flow for Distribution Networks with State Estimation Feedback

Conventional optimal power flow (OPF) solvers assume full observability of the involved system states. However in practice, there is a lack of reliable system monitoring devices in the distribution networks. To close the gap between the theoretic algorithm design and practical implementation, this work proposes to solve the OPF problems based on the state estimation (SE) feedback for the distribution networks where only a part of the involved system states are physically measured. The SE feedback increases the observability of the under-measured system and provides more accurate system states monitoring when the measurements are noisy. We analytically investigate the convergence of the proposed algorithm. The numerical results demonstrate that the proposed approach is more robust to large pseudo measurement variability and inherent sensor noise in comparison to the other frameworks without SE feedback.

distirbution systems↗

Bi-Level Linear Programming Model for Automatic Load Shedding: A Distributed Wide-Area Measurement System-based Solution

Load shedding is currently implemented as a two-step based approach. In the first step, manual load shedding is taken place, were system operators, using estimates, inform distribution utilities of predicted stressful conditions. Information provided include the potential use of energy reserves, as well as load shedding amount. In a second step, automatic load shedding is done. The latter is realized using protection relays. While considering frequency variation, pre-defined values of load to be shed and correspondent number of stages for such to be realized are transformed into relay settings. Under-frequency protection relays use only local measurements towards decision making, thus operate in a decentralized architecture. Decision making is done in milliseconds plus breaker time. While this approach has provided much system reliability, considering the new smart grid paradigm, where system dynamics are much faster due to increasing renewable resources penetration, in some operating conditions it will generate sub-optimal solutions, such as islanding. Phasor measurement units provide a source of information which can be useful for this problem. Centralized architecture-based solutions for automatic load shedding, as present in the state-of-the-art, require though total processing times which are not acceptable for real-life implementation. In this work, considering the above, a bi-level linear programming model is presented. The model is implemented considering a distributed architecture while leveraging phasor measurement units data. The upper-level model estimates the current system state. Results of this model are embedded in a lower-level model, which decision variables are the location and load value to be shed. Easy-to-implement model, built-on the classic weighted least squares solution, highlight potential aspects towards real-life applications.

Bretas, Arturo Suman↗

AMS History from 1950 to 2020

Presentation illustrates over 60 years of aerial measurements and establishment of Aerial Measuring System asset by the DOE. The presentation will be used as part of the training new AMS personnel. Presentation illustrates over 60 years of aerial measurements and establishment of Aerial Measuring System asset by the DOE. The presentation will be used as part of the training new AMS personnel.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Search for charmed baryons in the Λ c + η system and measurement of the branching fractions of Λ c ( 2880 ) + and Λ c ( 2940 ) + decaying to Λ c + η and p D 0 relative to Σ c ( 2455 ) π

We search for excited charmed baryons in the Λ c + η system using a data sample corresponding to an integrated luminosity of 980 fb − 1 . The data were collected by the Belle detector at the KEKB e + e − asymmetric-energy collider. No significant signals are found in the Λ c + η mass spectrum, including the known Λ c ( 2880 ) + and Λ c ( 2940 ) + . Clear Λ c ( 2880 ) + and Λ c ( 2940 ) + signals are observed in the p D 0 mass spectrum. We set upper limits at 90% credibility level on ratios of branching fractions of Λ c ( 2880 ) + and Λ c ( 2940 ) + decaying to Λ c + η relative to Σ c ( 2455 ) π of < 0.13 for the Λ c ( 2880 ) + and < 1.11 for the Λ c ( 2940 ) + . We measure ratios of branching fractions of Λ c ( 2880 ) + and Λ c ( 2940 ) + decaying to p D 0 relative to Σ c ( 2455 ) π of 0.75 ± 0.03 ( stat ) ± 0.07 ( syst ) for the Λ c ( 2880 ) + and 3.59 ± 0.21 ( stat ) ± 0.56 ( syst ) for the Λ c ( 2940 ) + . Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Commercialization of Reflected Target Non-Intrusive Assessment (ReTNA) Tool, for Indoor Optical Analysis of Heliostats

Under HelioCon, NLR began developing a new optical measurement system, called Reflected Target Non-Intrusive Assessment (ReTNA). ReTNA has shown promise towards addressing metrology gaps for heliostat used in concentrated solar thermal (CST) plant. This project is focused on advancing this measurement system from the laboratory into industry, where it can provide valuable information for heliostat developers during research, development, and qualification of a heliostat design, and be used for quality assurance during heliostat manufacture. Over the course of this project, ReTNA was deployed at several commercial heliostat facilities. The system developed and deployed with the primary project partner, Solar Dynamics LLC, is described in detail. The report discusses each project Milestone, the ending status, the achieved value, and how these Milestones improve and qualify the ReTNA measurement tool. Finally, the final report covers the market advancements, path forward, commercial successes, and lessons learned. Final Technical report for TCF Base Technology-Specific project TCF-23-20118, Commercialization of Reflected Target Non-Intrusive Assessment (ReTNA) tool, for indoor optical analysis of Heliostats.

14 SOLAR ENERGY↗

Analyzing count data with measurement error

In this article, we analyze observed count data such as the number of defects in a steel product where the observed counts are the true counts measured with errors. We account for the measurement error by using a measurement error model based on a latent lognormal (LLN) distribution. We consider making inference about a single population (e.g., from samples of a production lot) and a regression model (e.g., from runs of a designed experiment), where the measurement system properties are known, that is, the parameters of the LLN distribution are known. Then, we consider simultaneous inference for the single population and regression model as well as the measurement system. We demonstrate the proposed methodology with both simulated and real observed counts.

42 ENGINEERING↗

Grand-scale Atmospheric Imaging Apparatus (GAIA) and Wind LiDAR Multi-scale Measurements in the Atmospheric Surface Layer

Understanding the organization and dynamics of turbulence structures in the atmospheric surface layer (ASL) is important for fundamental and applied research in different fields, including weather prediction, snow settling, particle and pollutant transport, and wind energy. The main challenges associated with probing and modeling turbulence in the ASL are: i) the broad range of turbulent scales associated with the different eddies present in high Reynolds-number boundary layers ranging from the viscous scale ($\mathcal{O}$(mm)) up to large energy-containing structures ($\mathcal{O}$(km)); ii) the non-stationarity of the wind conditions and the variability associated with the daily cycle of the atmospheric stability; iii) the interactions among eddies of different sizes populating different layers of the ASL, which contribute to momentum, energy, and scalar turbulent fluxes. Creative and innovative measurement techniques are required to probe near-surface turbulence by generating spatio-temporally-resolved data in the proximity of the ground and, at the same time, covering the entire ASL height with large enough streamwise extent to characterize the dynamics of larger eddies evolving aloft. To this aim, the U.S. National Science Foundation sponsored the development of the Grand-scale Atmospheric Imaging Apparatus (GAIA) enabling super-large snow particle image velocimetry (SLPIV) in the near-surface region of the ASL. This inaugural version of GAIA provides a comprehensive measuring system by coupling SLPIV and two scanning Doppler LiDARs to probe the ASL at an unprecedented resolution. A field campaign performed in 2021–2022 and its preliminary results are presented herein elucidating new research opportunities enabled by the GAIA measuring system.

17 WIND ENERGY↗

An automated multiplexed turbidometric and data collection system for measuring growth kinetics of anaerobes dependent on gaseous substrates

Standard methods of monitoring the growth kinetics of anaerobic microorganisms are generally impractical when there is a protracted or indeterminate period of active growth, and when high numbers of samples or replications are required. As part of our studies of the adaptive evolution of a simple anaerobic syntrophic mutualism, requiring the characterization of many isolates and alternative syntrophic pairings, here we developed a multiplexed growth monitoring system using a combination of commercially available electronics and custom designed circuitry and materials. This system automatically monitors up to 64 sealed, and as needed pressurized, culture tubes and reports the growth data in real-time through integration with a customized relational database. The utility of this system was demonstrated by resolving minor differences in growth kinetics associated with the adaptive evolution of a simple microbial community comprised of a sulfate reducing bacterium, Desulfovibrio vulgaris, grown in syntrophic association with Methanococcus maripaludis, a hydrogenotrophic methanogen.

59 BASIC BIOLOGICAL SCIENCES↗

cuZ-Checker: A GPU-Based Ultra-Fast Assessment System for Lossy Compressions

Lossy compression is becoming an indispensable technique for the success of today's extreme-scale high-performance computing projects that produce vast volumes of data during scientific simulations or instrument data acquisitions. Comprehensively understanding the compression quality and performance of different lossy compressors is critical to selecting the best-fit compressors and using them properly and efficiently in practice. A few lossy compression assessment tools (e.g., Z-checker) have been developed, but none of them support the execution in a GPU environment. This is a significant gap because many recent extreme-scale applications and lossy compressors (e.g., cuSZ) can run entirely within GPUs. In this work, we develop an efficient lossy compression measuring system (called cuZ-Checker) on the GPU platform, which aims to perform the lossy compression quality and performance assessment completely within the GPU environment. Our contribution is threefold. (1) We develop a novel GPU-based lossy compression measuring framework using a computation pattern-based design approach. This approach classifies the computing-intensive metrics into three categories based on their patterns which creates large opportunities for kernel fusion and data reuse. (2) For each pattern in cuZ-Checker, we develop a CUDA kernel and provide fine-grained optimizations to boost its performance. (3) We thoroughly evaluate our cuZ-checker on a V100 GPU using four real-world scientific application datasets. Experiments show that cuZ-Checker can significantly accelerate the overall lossy compression assessment performance by 23X similar to 31X compared with the OpenMP-based multithreading CPU performance. To the best of our knowledge, this is the first lossy compression measuring system designed for GPU devices.

GPU↗

Miniature fluorescence sensor for quantitative detection of brain tumour

Fluorescence-guided surgery has emerged as a vital tool for tumour resection procedures. As well as intraoperative tumour visualisation, 5-ALA-induced PpIX provides an avenue for quantitative tumour identification based on ratiometric fluorescence measurement. To this end, fluorescence imaging and fibre-based probes have enabled more precise demarcation between the cancerous and healthy tissues. These sensing approaches, which rely on collecting the fluorescence light from the tumour resection site and its “remote” spectral sensing, introduce challenges associated with optical losses. In this work, we demonstrate the viability of tumour detection at the resection site using a miniature fluorescence measurement system. Unlike the current bulky systems, which necessitate remote measurement, we have adopted a millimetre-sized spectral sensor chip for quantitative fluorescence measurements. A reliable measurement at the resection site requires a stable optical window between the tissue and the optoelectronic system. This is achieved using an antifouling diamond window, which provides stable optical transparency. The system achieved a sensitivity of 92.3% and specificity of 98.3% in detecting a surrogate tumour at a resolution of 1 × 1 mm 2 . In conclusion, as well as addressing losses associated with collecting and coupling fluorescence light in the current ‘remote’ sensing approaches, the small size of the system introduced in this work paves the way for its direct integration with the tumour resection tools with the aim of more accurate interoperative tumour identification.

59 BASIC BIOLOGICAL SCIENCES↗

Emission Inventories from Natural Gas Storage Facilities using Regional Frequency Comb Laser Monitoring and Aircraft Flyovers. Final Report

The project centers around a ground-based regional methane sensor developed by the CU/NIST team members under the DOE ARPA-E MONITOR program, and sophisticated aircraft measurement techniques developed by the UCD/Scientific Aviation team (responsible for a recent Science publication quantifying the Aliso Canyon storage field release). The dual frequency-comb spectrometer is an invisible, eye-safe laser capable of measuring atmospheric methane concentrations along beam paths 1+ miles in length with high precision and stability (<1 ppb methane over 1 mile). The CU/NIST team has developed a unique approach to using a single, central spectrometer to locate and size methane emissions as small as 6 scfh from specific gas field structures within the 1+ mile range of the laser. Deployment involves the stationing of small cubic mirrors at strategic locations across the gas storage site. The mirrors direct light from the spectrometer back to a detector, where methane concentrations are recorded based on light absorption at specific wavelengths. The measurements are coupled with high resolution gas transport models based on meteorological measurements (wind, etc.) to determine the precise location and emission rate of methane sources. The calibration-free and continuous nature of dual frequency-comb spectrometer measurements means that a large area can be monitored continuously for temporal variability of emissions over long periods of time. The aircraft measurements involve spiral flights around storage facilities with a sensitive ethane/methane measurement package. Upwind/downwind concentration comparisons and wind data provide total facility emissions data. During this project, a new micrometeorological package was integrated onto the Scientific Aviation aircraft to provide even greater emissions quantification capability. In this project, the ground-based measurement system was deployed for 11 months (to capture seasonal variability) at a West Coast storage facility, together with a campaign of twice monthly aircraft total facility emissions flights. The data from these two modalities was combined to quantify the methane emissions from the facility with first-of-its-kind temporal and spatial detail. Concurrent with this deployment, the aircraft team performed flights to quantify emissions at a wider array of previously un-surveyed storage sites. The ground-based measurement system was then moved to an additional site of differing total storage and delivery capacity. Aircraft mass balance flights continued, repeatedly surveying (twice monthly) this site, as well as surveying a large number of previously un-assessed sites spanning a variety of size, reservoir type and age. Assessment of ground-based, temporally and spatially detailed methane emissions information alongside aircraft-derived methane total facility emissions information led to an improved understanding of emissions, relevant for inventories of the natural gas storage sector. In particular, this work provided temporal detail (seasonal of emissions and frequency of leaks) to stakeholders and personnel responsible for updates to the EPA’s GHGI. The impact of the proposed work has been a dramatic improvement in the temporal, spatial, and site- and type- specific detail and quantification of emissions inventories for the natural gas storage sector. This work directly benefits the EPA’s GHGI, directly ameliorates the environmental impacts and public health and safety of the natural gas storage sector, and aids policymakers and industry to make sound choices with respect to management and regulation.

03 NATURAL GAS↗

Devices and systems for measuring the state of a valve, and related methods

A device for measuring a state of a valve may include a housing configured to connect to a handle of a valve or a body of a valve, a sensor supported on one of the housing or the valve stem, and an indicator detectable by the sensor. The indicator may be configured to move relative to the sensor in response to movement of a valve stem or valve handle during opening and closing of the valve. The sensor may be configured to detect a position of the indicator to determine a state of the valve. Related systems and methods are also described.

Agarwal, Vivek↗

The CMS Magnetic Field Measuring and Monitoring Systems

This review article describes the performance of the magnetic field measuring and monitoring systems for the Compact Muon Solenoid (CMS) detector. To cross-check the magnetic flux distribution obtained with the CMS magnet model, four systems for measuring the magnetic flux density in the detector volume were used. The magnetic induction inside the 6 m diameter superconducting solenoid was measured and is currently monitored by four nuclear magnetic resonance (NMR) probes installed using special tubes outside the barrel hadron calorimeter. Two more NRM probes were installed at the faces of the tracking system. The field inside the superconducting solenoid was precisely measured in 2006 in a cylindrical volume of 3.448 m in diameter and 7 m in length using 10 three-dimensional (3D) B-sensors based on the Hall effect. These B-sensors were installed on each of the two propeller arms of an automated field-mapping machine. In addition to these measurement systems, a system for monitoring the magnetic field during the CMS detector operation has been developed. Inside the solenoid in the horizontal plane, 4 3D B-sensors were installed at the faces of the tracking detector. Twelve 3D B-sensors were installed on the surfaces of the flux-return yoke nose disks. Seventy 3D B-sensors were installed in the air gaps of the CMS magnet yoke. A specially developed flux loop technique was used for the most complex measurements of the magnetic flux density inside the steel blocks of the CMS magnet yoke. The flux loops are installed in 22 sections of the flux-return yoke blocks. The areas enclosed by these coils varied from 0.3 to 1.59 m$^{2}$ in the blocks of the barrel wheels and from 0.5 to 1.12 m$^{2}$ in the blocks of the yoke endcap disks. The development of these systems and the results of the magnetic flux density measurements across the CMS magnet are presented and discussed in this review article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗