Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement system assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Measurement Acceptance Region (MAR) Assessment Results Based on the October 2019 Sludge Batch 10 Projections

Recent analysis of a Tank 26 sample indicated a higher than anticipated sulfur concentration in the supernatant and a significant amount of insoluble sulfur. The final concentration in the glass product would be well above the sulfate limits of 0.6-0.65 weight percent (wt.%) determined for previous sludge batches. In preparation for Sludge Batch 10 (SB10) processing, washing of Tank 51 will be performed to reduce the sulfate concentration in the glass product to less than 0.65 wt.% at waste loadings (WLs) of interest. To evaluate the feasibility of two Tank 51 Na wash endpoints (0.8 and 1.2M), Savannah River Remediation requested that the Savannah River National Laboratory perform assessments using the Defense Waste Processing Facility Product Composition Control System (PCCS) models and their associated Measurement Acceptance Region (MAR) constraints.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multiscale Assessment of Caprock Integrity for Geologic Carbon Storage in the Pennsylvanian Farnsworth Unit, Texas, USA

Leakage pathways through caprock lithologies for underground storage of CO2 and/or enhanced oil recovery (EOR) include intrusion into nano-pore mudstones, flow within fractures and faults, and larger-scale sedimentary heterogeneity (e.g., stacked channel deposits). To assess multiscale sealing integrity of the caprock system that overlies the Morrow B sandstone reservoir, Farnsworth Unit (FWU), Texas, USA, we combine pore-to-core observations, laboratory testing, well logging results, and noble gas analysis. A cluster analysis combining gamma ray, compressional slowness, and other logs was combined with caliper responses and triaxial rock mechanics testing to define eleven lithologic classes across the upper Morrow shale and Thirteen Finger limestone caprock units, with estimations of dynamic elastic moduli and fracture breakdown pressures (minimum horizontal stress gradients) for each class. Mercury porosimetry determinations of CO2 column heights in sealing formations yield values exceeding reservoir height. Noble gas profiles provide a “geologic time-integrated” assessment of fluid flow across the reservoir-caprock system, with Morrow B reservoir measurements consistent with decades-long EOR water-flooding, and upper Morrow shale and lower Thirteen Finger limestone values being consistent with long-term geohydrologic isolation. Together, these data suggest an excellent sealing capacity for the FWU and provide limits for injection pressure increases accompanying carbon storage activities.

58 GEOSCIENCES↗

Smart quantum statistical imaging beyond the Abbe-Rayleigh criterion

The wave nature of light imposes limits on the resolution of optical imaging systems. For over a century, the Abbe-Rayleigh criterion has been utilized to assess the spatial resolution limits of imaging instruments. Recently, there has been interest in using spatial projective measurements to enhance the resolution of imaging systems. Unfortunately, these schemes require a priori information regarding the coherence properties of “unknown” light beams and impose stringent alignment conditions. Here, we introduce a smart quantum camera for superresolving imaging that exploits the self-learning features of artificial intelligence to identify the statistical fluctuations of unknown mixtures of light sources at each pixel. This is achieved through a universal quantum model that enables the design of artificial neural networks for the identification of photon fluctuations. Our protocol overcomes limitations of existing superresolution schemes based on spatial mode projections, and consequently provides alternative methods for microscopy, remote sensing, and astronomy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Big Data For Operation and Maintenance Cost Reduction

The purpose of this research is to develop a first-of-a-kind framework for integrating Big Data capability into the daily activities of our current fleet of nuclear power plants. Big Data is traditionally defined as data sets with high volume, velocity, and heterogeneity, and the existing Big Data analytics capabilities are now widely popular in fields such as finance, weather, e-commerce, healthcare and sports. In the nuclear industry, while the volume and velocity of data may present computational challenges for existing analytics capabilities, data heterogeneity are seen to present the major challenge. This research project mainly focuses on incorporating the wide range of data heterogeneities in nuclear power plants into an integrated Big Data Analytics capability. The primary end-product of this project is a Big Data framework that is capable of dealing with the large volume and heterogeneity of the data found in nuclear power plants to extract timely and valuable information on equipment performance. The framework can generate system insights that are actionable relations between measurable impacts and the corresponding maintenance action plans and enable optimization of plant operation and maintenance based on the extracted information. The developed framework is capable of handling heterogeneous data including both image data and time-series sensor data. Specifically, this developed framework includes the following components. The first component is an overarching maintenance ontology which includes system insights required by maintenance optimization. The maintenance ontology interacts with other components in the developed framework. The second component handles Piping & Instrumentation Diagram (P&ID) data. It can be used to extract system components and their relations automatically from the P&IDs. This extracted information is stored in the first component, i.e., maintenance ontology, and is also used as input to the third component, i.e., a tool for generating the fault tree for the corresponding system. The generated fault tree in turn is stored in the ontology for assessing risk that is used as a criterion in maintenance policy optimization. The fourth component is a tool for inferring the parameters in the Markov degradation model for a nuclear system. It uses basic information from the ontology. The fifth component is a tool for assessing the degradation level using sensor measurement data, for example, pressure, flowrate. This tool can be used for determining corrective maintenance actions. The results obtained from components four and five are returned to the ontology. The sixth component of the framework is a tool for optimizing the maintenance policy for a nuclear system of interest. It takes certain basic information from the ontology, e.g., costs of maintenance actions and system failures, as input, and returns the optimal maintenance policy to the ontology. This tool can be used for determining predictive maintenance actions. A set of experiments have also been conducted to verify the algorithms developed in this project for nuclear system degradation monitoring. The experiments are based on four solenoid valves, similar to the ones used in nuclear power plants. The analyses based on the experimental data using two algorithms, i.e., the Randomized Window Decomposition (RWD) algorithm and the particle filtering algorithm, and the results are introduced in the report. The Big Data framework developed in this project can be used as a support tool in daily activities of plant operation and maintenance and will reduce current costs while maintaining or improving safety levels. Overall, the project will not only benefit existing reactors, however it will open new frontiers to realize the long overdue value of Big Data Analytics in the nuclear sphere.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement Acceptance Region (MAR) Assessment Results Based On Sludge Batch 10 Projections from December 2021, February 2022 and August 2022

The Defense Waste Processing Facility (DWPF) is currently preparing to initiate processing of Sludge Batch 10 (SB10), which is comprised of material from Tanks 11H, 13H, 15H, and 26F, Alternate Feed Stock-2 and Sodium Reactor Experiment material from H-Canyon. Frit 473 (8B 2 O 3 -8Li 2 O-5Na 2 O-79SiO 2 , in weight percent) was recommended for sludge-only (SO) and coupled processing with the Salt Waste Processing Facility (SWPF) based on previous assessments of SB10 projections with the DWPF Product Composition Control System (PCCS) glass property models and their associated Measurement Acceptance Region (MAR) constraints. Due to the lower processing rate of Sludge Batch 9 (SB9), the heel in Tank 40 is anticipated to be greater than 40 inches at the projected start of SB10 processing to meet the upcoming Accelerated Basin Deinventory addition dates in Tank 51 for Sludge Batch 11. In December 2021 and February 2022, Savannah River Remediation System Planning provided updated SB10 Tank 40 blend projections based on heels of 74 inches, 84 inches, 94 inches and 103.4 inches. Savannah River Mission Completion (SRMC) subsequently pursued Wash Cycle Y to further reduce the total sulfur in the sludge batch and increase processing flexibility at DWPF. In August 2022, SRMC System Planning provided an updated SB10 Tank 40 blend projection with a 76 inch-heel representing Decant Y2 and 60 kilogallons of bearing water inleakage that is anticipated during the Tank 51 to Tank 40 transfer. The objectives of this task were to: • Determine the impact on the operating windows for SO and coupled processing • Determine whether any composition gaps exist between the already completed SB10 variability study and the reprojected SB10 glass composition region • Compare the SB10 reprojected glass composition region to the DWPF PCCS model development and validation ranges to ensure that compositional gaps do not exist between the data sets. This report documents the results of these evaluations. Calculation-based frit assessments were performed using the DWPF PCCS glass property models and their associated MAR constraints. Evaluated parameters for coupled processing included the following transfer volumes per Sludge Receipt and Adjustment Tank batch: 5700 gallons of Tank 40 sludge, 2400-4500 gallons of the SWPF monosodium titanate (MST) and sludge solids stream, and 15,000 gallons of strip effluent. Based on these MAR assessment results, Frit 473 remains viable for SB10 processing. A target waste loading (WL) of 36% is possible for SO operation and single strike (0.4 g/L MST) coupled processing up to 600 mg/L of SB9 insoluble sludge solids at a nominal transfer volume of ~2800 gallons. Increasing the single strike transfer volume to 4500 gallons may reduce the maximum WL below 40%. Operating windows are 12 percentage points for SO processing and 14-16 percentage points for coupled processing. Frit 625 allows for a target WL of 36% and is acceptable for use during the SB9 to SB10 transition to deplete remaining inventory as needed. Operating windows are 8 percentage points for SO processing and 12-14 percentage points for coupled processing. Predictive PCCS evaluations performed at DWPF will provide insight into batch-specific acceptability at desired WLs for compositions having expected oxide ratios during processing versus the extreme vertices (corner points) evaluated in this study. The reprojected SB10 glass composition region generally overlaps the previously evaluated SB10 variability study composition region. Thus, the minor composition shift of these updated SB10 projections indicates that no additional glasses are necessary to demonstrate acceptability relative to the chemical durability of the Environmental Assessment benchmark glass and predictability using the current PCCS models for durability. Based on a comparison of the PCCS model development and validation data to the reprojected SB10 glass composition region, the viscosity and liquidus temperature models will reliably predict SB10 compositions. No additional glasses are necessary to demonstrate predictability of these models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Power Systems Measurements: A Literature Review

In 2020, a literature survey was performed as part of a project aimed at producing guidance for the Department of Energy in the form of a Roadmap. The topic of the Roadmap was measurement. That was viewed as being generally underrepresented in consideration of sensing and measurement or instrumentation and measurement. Sensing is just the beginning of a process, and the instrument is just the container for the process. Measurement, the experimental process, has acquired a considerable body of theory over the last few decades, theory that is not widely taught and disseminated. The results of the survey can be said broadly to reflect that lack of appreciation. Specifically, the review found that there is support for the development of a more “capable” PMU. New algorithms and new documentary standards will be needed. Some of the findings are: (1) Point-on-wave technology adds new capability to the existing suite of measurements, and could allow for improved operation and protection (2) Power quality analysis has historically been concerned with assessment of how non-sinusoidal the delivered voltage shows promise in signature recognition, a departure from the modeling that has historically characterized power system measurements. (3) The PMU is assed as being a remarkable measurement system, but its performance is held back by the lack of understanding of the measurement theory underpinning its operation. (4) The PMU is being considered for application in the distribution system. There is a danger that it will be seen only in the light of the successful PMU implementation in transmission, and the two have different requirements. These various expansions of measurements will no doubt benefit from a better appreciation of the theoretical aspects of measurement. In this, and other, regards, our survey of the literature has identified gaps as well as possibilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Extended real-time voltage instability identification method based on synchronized phasor measurements

This paper presents an extended adaptive approach designed to accurately estimate the Thévenin equivalent parameters using phasor measurements at a given bus for measurements lying in any of four quadrants of the PQ-plane. The improvement is achieved by using a new condition to properly update the estimated parameters after an initial guess. Based on an adaptive philosophy, the proposed approach can correctly account for the intrinsic nonlinearities of a power system, can provide a real-time estimation of Thévenin parameters, and does not require network topology knowledge. The method is validated using the Kundur 2-area system, showing estimation improvements compared to the current adaptive approach and the classical recursive least-squares method. The proposed approach is able to estimate both sides of the system with respect to the measurement bus. In addition, a data-driven voltage stability index is developed. To illustrate the performance of the proposed approach in a larger power system, a voltage stability assessment is carried out on the IEEE 39-bus system, considering the action of overexcitation limiters of generators and nonlinear loads. The proposed approach is suitable for applications that require an accurate Thévenin equivalent estimation in real-time, such as for voltage stability assessment. The new approach provides a reliable tool for the system operators to make proper and timely decisions.

42 ENGINEERING↗

Solar Radiometer Instrumentation Evaluation: Cooperative Research and Development (Final Report, CRADA Number CRD-16-00619)

The purpose and intent of this agreement is to evaluate newly manufactured thermopile pyranometers and spectroradiometers. The purpose also extends to provide a framework for Participant to conduct research to improve and develop new radiometric devices and application in the future. The overall objective is to provide more accurate, site-specific, long-term, continuous measurements of the solar resources needed by industry to increase the deployment and improve the operations of photovoltaic and concentrating solar power plants. This CRADA addresses the needs for proven solar irradiance measurement to validate resource assessment models and generate high quality data used for site selection, energy system design, deployment, maintenance, and operation. This work will be conducted at NREL and Participant facilities. This project will place instrumentation at the NREL Solar Radiation Research Laboratory (SRRL) in cooperation with EKO Instruments, USA. Participant instruments will be deployed for the purpose of evaluation under controlled conditions. The scope of the project will be a 3 years-long segmented comparison of the instruments vs. other NREL baseline instruments with a well-characterized history. These evaluations will include planned improvements to instruments as well as extensions of future instrument applications. The final evaluation will be a written report similar to the work done by Wilcox and Myers (see http://www.nrel.gov/docs/fy09osti/44627.pdf).

14 SOLAR ENERGY↗

Organic contamination detection for isotopic analysis of water by laser spectroscopy

Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O-excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid- and vapour-mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O-excess contamination detection approach was tested. This is a post-processing detection tool for both liquid and vapour IRIS triple-isotope analyses, utilizing calculated 17 O-excess values to flag contaminated samples. Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour-IRIS analyses had larger errors than those from liquid-IRIS analyses. The 17 O-excess approach identified methanol driven error in liquid- and vapour-mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O-excess method. Here our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O-excess method was therefore useful for data quality control. Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O-excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.

60 APPLIED LIFE SCIENCES↗

Stannous chloride as a tool for mercury stripping in contaminated streams: Experimental assessment of toxicity in an invertebrate model species

In this work, the chronic toxicity of an innovative Hg water treatment system using tin (Sn) (II) chloride (SnCl 2 ) followed by air stripping was assessed through measurements of survival, growth, and reproduction rate in the freshwater cladoceran Ceriodaphnia dubia, a model species for toxicity testing. We first calculated the concentrations of Hg causing 25% reduction in survival and reproduction (Lethal or Inhibition Concentrations, or LC 25 and IC 25 , for survival and reproduction, respectively) through exposure to aqueous Hg at concentrations ranging from 0 to 25,000 ng L -1 . Then, we treated media (DMW and natural stream water) contaminated with Hg at LC 25 and IC 25 concentrations with SnCl 2 at a Sn:Hg stoichiometric ratio of 8:1 and air stripping and exposed C. dubia to this Sn-amended media. Our results showed that Hg significantly affected survival, reproduction rates and impaired growth. SnCl 2 -treatment removed 100% of the Hg from the media at all concentrations tested with no deleterious effects on survival, growth and reproduction. Our results confirmed the efficacy of SnCl 2 in removing aqueous Hg from stream water and showed that the added Sn did not impact C. dubia at the concentrations tested, supporting the suitability of SnCl 2 -based treatments in appropriate Hg-contaminated environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of feed variability on cesium removal with multiple actual waste samples from the Hanford site

Here, the Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. This lot of material was found to have superior performance in comparison to historic batches of CST. Ion exchange column and batch contact testing with supernate from Hanford tanks AP-105, AP-107 and AW-102 was performed to assess the impact of feed variability on system performance. These tests demonstrated that batch contact measurements provide a reasonable prediction of column capacities with some deviation in performance attributed to column dynamics. In addition, the variability in CST capacity for cesium in the various actual waste samples does not track with historical understanding of the competing cations, suggesting that tank waste samples contain other components that may significantly impact cesium loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The evolution of grain boundary energy in textured and untextured Ca–doped alumina during grain growth

The role of anisotropic grain boundary energy in grain growth is investigated using textured microstructures that contain a high proportion of special grain boundaries. Textured and untextured Ca–doped alumina was prepared by slip casting inside and outside a high magnetic field, respectively. At 1600°C, the textured microstructure exhibits faster growth than the untextured microstructure and its population of low–angle boundaries increases. Atomic force microscopy (AFM) is employed to measure the geometry of thermal grooves to assess the relative grain boundary energy of these systems before and after growth. In the textured microstructure, the grain boundary energy distribution narrows and shifts to a lower average energy. Conversely, the energy distribution broadens for the untextured microstructure as it grows and exhibits abnormal grain growth. Further analysis of the boundary networks neighboring abnormal grains reveals an energy incentive that facilitates their growth. These results suggest that coarsening is not the only dominant grain growth mechanism and that the system can lower its energy effectively by replacing high energy boundaries with those of low energy. The faster growth of lower energy boundaries suggests that isotropic simulations do not adequately account for anisotropic grain growth mechanisms or anisotropic mobility.

36 MATERIALS SCIENCE↗

Evaluation of IEC 62443 Standard Gaps for Electric Grid Substation Model Use Case

This report presents an evaluation of the IEC 62443 standards in the context of electric grid substations, as part of a collaborative effort among Sandia National Laboratories (SNL), Idaho National Laboratory (INL), and the National Renewable Energy Laboratory (NREL). The primary objective is to assess the applicability of these standards to enhance cybersecurity measures for industrial automation and control systems (IACS) within the energy sector. The evaluation identifies strengths, such as the scalability of security levels and the structured lifecycle guidance provided by IEC 62443. However, it also highlights significant gaps, including limited integration of physical security, insufficient guidance for legacy systems, and challenges in addressing emerging threats like supply chain vulnerabilities. Recommendations for refining the standards are proposed, including the need for tailored guidance for securing legacy systems, integrating physical security with cybersecurity frameworks, and enhancing interoperability across multi-vendor environments. By addressing these gaps, the IEC 62443 standards can be strengthened to ensure comprehensive cybersecurity for electric grid substations, thereby supporting the resilience and reliability of critical energy infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unraveling the Dynamics of Nucleosome Arrays

The organization of genomic DNA into chromatin is a fundamental determinant of genome stability, regulation, and cellular function. Nucleosomes, the basic repeating units of chromatin, assemble into higher-order structures whose organization and heterogeneity remain difficult to characterize using conventional ensemble-averaged techniques. A key need in the field is the development of experimental approaches capable of directly visualizing nucleosome assemblies and their structural variability at the single-molecule level. This LDRD Lab-Wide project focused on establishing and evaluating atomic force microscopy (AFM)–based approaches for the characterization of nucleosome assemblies. The work emphasized experimental workflows for preparing, imaging, and assessing multi-nucleosome systems, rather than isolated single nucleosomes. Through method development and exploratory measurements, the project demonstrated the feasibility of applying scanning probe microscopy to investigate chromatin-relevant assemblies and provided preliminary insight into the strengths and limitations of this approach for future quantitative studies. Results and lessons learned from this effort were disseminated to the broader scientific community through multiple national conference presentations, helping to position LLNL for continued work in chromatin and genome organization research.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Nondestructive Evaluation (NDE) of Cable Anomalies using Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR)

This report presents a comparative assessment of the performance of frequency domain reflectometry (FDR) and spread spectrum time domain reflectometry (SSTDR) in detecting a wide range of electrical cable anomalies. All tests and results reported herein were performed at the PNNL Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed. The primary objective of this work was to evaluate the effectiveness of SSTDR, a fledgling cable monitoring technique that shows promise for application in online monitoring of energized cable systems, against FDR, an offline technique widely employed in the nuclear power plant (NPP) industry. FDR tests are becoming more widely used in nuclear power plant cable aging management and test programs – particularly for low voltage cables. FDR capabilities for these kinds of tests have been reported by PNNL and others. The FDR test is performed on de-energized cables by connecting the FDR instrument to two of the cable conductors, or one conductor and the shield. A broad band low voltage (< 5 V) chirp is introduced in the cable, and any reflected response is captured in the frequency domain. The captured reflection is then processed by performing an inverse Fourier transform to a time domain response which can then be converted to a distance response based on the cable velocity of propagation (VoP). SSTDR measurements are functionally similar to FDR measurements in that a broad-band voltage signal composed of a square or sine wave modulated pseudo-random sequence of chips (< 5 volts), is injected onto one of the cable conductors. The injected signal will experience partial energy reflection and transmission at each impedance discontinuity along the transmission line. Any reflected response is detected by computing a cross-correlation between the reflected signals and a delayed copy of the incident SSTDR signal. the time delay for the reflected signal to experience the best matched correlation with the incident signal, indicates the travel time for the signal to reach a change in impedance. By knowing this time delay and velocity of propagation (VoP) of the signal, one can compute the physical distance. A big advantage that SSTDR measurements have over other methods is the ability to be connected to energized or live wires (currently up to 1kV) thereby enabling online monitoring of cables. SSTDR has been used successfully in several applications, e.g., aircraft, rail, and photovoltaic systems. In this work FDR and SSTDR cable assessment techniques were used to characterize a variety of cable anomalies and faults including: (1) Presence or absence of a motor; (2) Ground faults and short circuit faults; (3) Moist environments and water ingress faults; (4) Accelerated thermal aging. Both shielded and non-shielded cables were evaluated in this report. Offline measurements were made using FDR and online measurements were made by SSTDR for a range of test scenarios. Based on the results across all cable anomalies evaluated in this study, FDR displayed high sensitivity towards cable condition assessment, while SSTDR showed promise for future application in monitoring NPP cable systems. However, further developments are suggested to improve the resolution and sensitivity of SSTDR towards faults and anomalies in low voltage cables.rt presents a comparative

42 ENGINEERING↗

When a cuvette is not a canopy: a caution about measuring leaf temperature during gas exchange measurements

Plant gas exchange systems are widely used to study leaf physiological processes and properties such as stomatal function and the maximum carboxylation rate of Rubisco. Increasingly, these systems are used to assess how leaf gas exchange varies with temperature in order to better understand how rising temperature will impact plant function. Examples of such studies include variation in optimal temperatures of photosynthesis as a function of species and growth environment, and respiratory acclimation to higher temperatures. Leaf thermoregulation leading to homeothermy has been reported based on leaf gas exchange measurements spanning a large (~25 °C) temperature range. However, as we show here, the design of a popular gas exchange system used for temperature-response measurements can lead to biased measurements of leaf temperature. Furthermore, we demonstrate this with an example showing that apparent leaf thermoregulatory behavior can arise even in empty cuvettes. More broadly, our results have implications for other temperature manipulations in similar gas exchange systems.

59 BASIC BIOLOGICAL SCIENCES↗

Structured light scanning artifact-based performance study

Structured light scanning is used to create a digital twin of a manufactured part, where features are extracted to determine if the part meets the designer’s intent and required tolerances. This paper describes repeatability and reproducibility analyses for a commercially-available structured light scanning system and measurement artifact. The repeatability study used five repeated scans at 15 measurement positions. Repeatability was assessed by randomly selecting one of the five scans at each of the 15 positions and creating a part mesh. This process was performed 50 times and the statistics for the dimension variations were calculated to isolate the scanning effects only. The same sequence was then performed for 10 of the 15 positions and five of the 15 positions to evaluate the repeatability sensitivity to the number of measurement positions. Reproducibility was assessed by selecting 15 positions to create a mesh and repeating the 15-position measurement sequence 10 times using different positions for each mesh construction. The statistics for the dimension variations were then calculated. This incorporated the effects of both scanning and the position and orientation of the part relative to the scanner. This sequence was repeated for 10-position and five-position scans to evaluate the corresponding sensitivity. Finally, the artifact dimensions from structured light scanning were compared to coordinate measuring machine measurements of the same features.

42 ENGINEERING↗