Development of a downhole tracer and pH measurement instrument for application in geothermal wells: Toward real-time chemical well logging.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Elaborate combination of techniques used to calibrate wind-measuring instrumentation aboard F104 airplane. Obtains wind profiles more rapidly. Airplane equipped with standard NACA research nose boom, including pressure probes and flow vanes yielding data on static and total pressures, angle of attack, and angle of sideslip. Has ring-laser-gyroscope inertial reference unit, giving linear and angular velocities, linear acceleration, and orientation of airplane. Body-mounted total-temperature sensor also used. Improved method of calibration devised to determine whether winds aloft at and shortly after time of measurement allow safe launch of Space Shuttle. Proves beneficial in other safety- or research-oriented applications in which wind velocities over range of altitudes must be determined in nearly real time.
Measuring instrument for lunar surface layer heat flow, temperature and thermal conductivity
Satellite-borne anisotropy and energy spectra measurement instruments for cosmic ray electrons and protons and solar and galactic X-rays
Rotating-pinhole calibrator designed for use in calibrating and testing optical instrument measuring sizes of cloud droplets, dust particles, and other small particles suspended in flowing air. Easily attachable to particle-size-measuring instrument and suitable for both quick verification of calibration in field and detailed calibration studies in laboratory. Calibrator used to determine such operating parameters of instrument as optical collection angles, depth of field, profile of laser beam used to measure particles, and response to trajectory of particle. Also used to align instrument. Pinhole reused any number of times without risk of variation in diffraction pattern. Furthermore, size of pinhole chosen precisely and at will.
The instruments and techniques of biomagnetic measurement have progressed greatly in the past 15 years and are now of a quality appropriate to clinical applications. The paper reports on recent developments in the design and application of SQUID (Superconducting Quantum Interference Device) magnetometers to biomagnetic measurement. The discussion covers biomagnetic field levels, magnetocardiography, magnetic susceptibility plethysmography, ambient noise and sensor types, principles of operation of a SQUID magnetometer, and laboratory techniques. Of the many promising applications of noninvasive biomagnetic measurement, magnetocardiography is the most advanced and the most likely to find clinical application in the near future.
Gas velocity measuring instrument measures transport time of ion-trace traveling fixed distance between ionization probe and detector probe. Electric field superimposes drift velocity onto flow velocity so travel times can be reduced to minimize ion diffusion effects.
Measurements of absorption and emission complement thermal measurements. Two laboratory instruments for research in combustion and pyrolysis equipped for radiative as well as thermal measurements. One instrument essentially differential scanning calorimeter (DSC) modified to detect radiation emitted by flames. Provides means to evaluate limits of flammability of materials exhibiting exothermic reactions in DSC's. Other instrument used to determine pyrolysis properties of specimens exposed to various gases by measurement of infrared absorption spectra of pyrolysis products.
Sonic boom measurement instrumentation noting use of frequency response, vibration isolation, wind screening, etc
RF noise measurement instrumentation using statistical analysis for better interference characterization
Instrumentation - sensors, information processing, and control systems
As discussed in the first chapter of this book, there are many different methods to measure a part using optical technology. Chapter 2 discussed the use of machine vision to measure macroscopic features such as length and position, which was extended to the use of interferometry as a linear measurement tool in chapter 3, and laser or other trackers to find the relation of key points on large parts in chapter 4. This chapter looks at measuring large parts to optical tolerances in the sub-micron range using interferometry, ranging, and optical tools discussed in the previous chapters. The purpose of this chapter is not to discuss specific metrology tools (such as interferometers or gauges), but to describe a systems engineering approach to testing large parts. Issues such as material warpage and temperature drifts that may be insignificant when measuring a part to micron levels under a microscope, as will be discussed in later chapters, can prove to be very important when making the same measurement over a larger part. In this chapter, we will define a set of guiding principles for successfully overcoming these challenges and illustrate the application of these principles with real world examples. While these examples are drawn from specific large optical testing applications, they inform the problems associated with testing any large part to optical tolerances. Manufacturing today relies on micrometer level part performance. Fields such as energy and transportation are demanding higher tolerances to provide increased efficiencies and fuel savings. By looking at how the optics industry approaches sub-micrometer metrology, one can gain a better understanding of the metrology challenges for any larger part specified to micrometer tolerances. Testing large parts, whether optical components or precision structures, to optical tolerances is just like testing small parts, only harder. Identical with what one does for small parts, a metrologist tests large parts and optics in particular to quantify their mechanical properties (such as dimensions, mass, etc); their optical prescription or design (i.e. radius of curvature, conic constant, vertex location, size); and their full part shape. And, just as with small parts, a metrologist accomplishes these tests using distance measuring instruments such as tape measures, inside micrometers, coordinate measuring machines, distance measuring interferometers; angle measuring instruments such as theodolites, autocollimators; and surface measuring instruments including interferometers, stylus profilers, interference microscopes, photogrammetric cameras, or other tools. However, while the methodology may be similar, it is more difficult to test a large object for the simple reason that most metrologists do not have the necessary intuition. The skills used to test small parts or optics in a laboratory do not extrapolate to testing large parts in an industrial setting any more than a backyard gardener might successfully operate a farm. But first, what is a large part? A simple definition might be the part's size or diameter. For optics and diffuse surface parts alike, the driving constraint is ability to illuminate the part's surface. For reflective convex mirrors, large is typically anything greater than 1 meter. But, for refractive optics, flats or convex mirrors, large is typically greater than 0.5 meter. While a size definition is simple, it may be less than universal. A more nuanced definition might be that a large part is any component which cannot be easily tested in a standard laboratory environment, on a standard vibration isolated table using standard laboratory infrastructure. A micro-switch or a precision lens might be easily measured to nanometer levels under a microscope in a lab, but a power turbine spline or a larger telescope mirror will not fit under that microscope and may not even fit on the table.
Computerized scanning instrumentation measures and displays trapped magnetic fields across the surface of high Tc superconductors at 77 K. Data are acquired in the form of a raster scan image utilizing stepping motor stages for positioning and a cryogenic Hall probe for magnetic field readout. Flat areas up to 45 mm in diameter are scanned with 0.5-mm resolution and displayed as false color images.
The capability to measure gene expression on board spacecraft opens the door to a large number of high-value experiments on the influence of the space environment on biological systems. For example, measurements of gene expression will help us to understand adaptation of terrestrial life to conditions beyond the planet of origin, identify deleterious effects of the space environment on a wide range of organisms from microbes to humans, develop effective countermeasures against these effects, and determine the metabolic bases of microbial pathogenicity and drug resistance. These and other applications hold significant potential for discoveries in space biology, biotechnology, and medicine. Supported by funding from the NASA Astrobiology Science and Technology Instrument Development Program, we are developing a fully automated, miniaturized, integrated fluidic system for small spacecraft capable of in-situ measurement of expression of several hundreds of microbial genes from multiple samples. The instrument will be capable of (1) lysing cell walls of bacteria sampled from cultures grown in space, (2) extracting and purifying RNA released from cells, (3) hybridizing the RNA on a microarray and (4) providing readout of the microarray signal, all in a single microfluidics cartridge. The device is suitable for deployment on nanosatellite platforms developed by NASA Ames' Small Spacecraft Division. To meet space and other technical constraints imposed by these platforms, a number of technical innovations are being implemented. The integration and end-to-end technological and biological validation of the instrument are carried out using as a model the photosynthetic bacterium Synechococcus elongatus, known for its remarkable metabolic diversity and resilience to adverse conditions. Each step in the measurement process-lysis, nucleic acid extraction, purification, and hybridization to an array-is assessed through comparison of the results obtained using the instrument with those from standard laboratory protocols. Once developed, the system can be used with minor modifications for multiple experiments on different platforms in space, including extension to higher organisms and microbial monitoring. A proposed version of GEMM that is capable of handling both microbial and tissue samples on the International Space Station will be briefly summarized.
Instrument errors, error reduction, and elements of measurements for measurement systems with feedback instrumentation
Multiple wavelength radiation measuring instrument for determining hot body or gas temperature