At least 127 records · Page 7

Cryogenic systems for the large deployable reflector

There are five technologies which may have application for Large Deployable Reflector (LDR), one passive and four active. In order of maturity, they are passive stored cryogen systems, and mechanical, sorption, magnetic, and pulse-tube refrigerators. In addition, deep space radiators will be required to reject the heat of the active systems, and may be useful as auxiliary coolers for the stored cryogen systems. Hybrid combinations of these technologies may well be more efficient than any one alone, and extensive system studies will be required to determine the best trade-offs. Stored cryogen systems were flown on a number of missions. The systems are capable of meeting the temperature requirements of LDR. The size and weight of stored cryogen systems are proportional to heat load and, as a result, are applicable only if the low-temperature heat load can be kept small. Systems using chemisorption and physical adsorption for compressors and pumps have received considerable attention in the past few years. Systems based on adiabatic demagnetization of paramagnetic salts were used for refrigeration for many years. Pulse-tube refrigerators were recently proposed which show relatively high efficiency for temperatures in the 60 to 80 K range. The instrument heat loads and operating temperatures are critical to the selection and design of the cryogenic system. Every effort should be made to minimize heat loads, raise operating temperatures, and to define these precisely. No one technology is now ready for application to LDR. Substantial development efforts are underway in all of the technologies and should be monitored and advocated. Magnetic and pulse-tube refrigerators have high potential.

Mason, Peter V.↗

The outer layers of cool, non-Mira carbon stars

The outer layers and near circumstellar envelope (CSE) of a typical carbon star have been studied using available data from theoretical and empirical models. An attempt is made to match the density-velocity structure of the photosphere-chromosphere region to values from the radio CO observations, which arise from the outer CSE. It is concluded that the stellar atmosphere includes a relatively thin high-temperature region close to hydrostatic equilibrium and a much more extended cooler region of outflowing gas and dust. To extend the outer photosphere and chromosphere to match the mass loss density appears to require an injection of energy and momentum by some mechanism rather close to the stellar surface.

Johnson, H. R.↗

Mechanisms and Feedbacks Causing Changes in Upper Stratospheric Ozone in the 21st Century

Stratospheric ozone is expected to increase during the 21st century as the abundance of halogenated ozone-depleting substances decrease to 1960 values. However, climate change will likely alter this "recovery" of stratospheric ozone by changing stratospheric temperatures, circulation, and abundance of reactive chemical species. Here we quantity the contribution of different mechanisms to changes in upper stratospheric ozone from 1960 to 2100 in the Goddard Earth Observing System Chemistry-Climate Model (GEOS CCM), using multiple linear regression analysis applied to simulations using either Alb or A2 greenhouse gas (GHG) scenarios. In both these scenarios upper stratospheric ozone has a secular increase over the 21st century. For the simulation using the Alb GHG scenario, this increase is determined by the decrease in halogen amounts and the greenhouse gas induced cooling, with roughly equal contributions from each mechanism. There is a larger cooling in the simulation using the A2 GHG scenario, but also enhanced loss from higher NOy and HOx concentrations, which nearly offsets the increase due to cooler temperatures. The resulting ozone evolutions are similar in the A2 and Alb simulations. The response of ozone due to feedbacks from temperature and HOx changes, related to changing halogen concentrations, are also quantified using simulations with fixed halogen concentrations.

Oman, Luke↗

Maximal Oxygen Uptake, Sweating and Tolerance to Exercise in the Heat

The physiological mechanisms that facilitate acute acclimation to heat have not been fully elucidated, but the result is the establishment of a more efficient cardiovascular system to increase heat dissipation via increased sweating that allows the acclimated man to function with a cooler internal environment and to extend his performance. Men in good physical condition with high maximal oxygen uptakes generally acclimate to heat more rapidly and retain it longer than men in poorer condition. Also, upon first exposure trained men tolerate exercise in the heat better than untrained men. Both resting in heat and physical training in a cool environment confer only partial acclimation when first exposed to work in the heat. These observations suggest separate additive stimuli of metabolic heat from exercise and environmental heat to increase sweating during the acclimation process. However, the necessity of utilizing physical exercise during acclimation has been questioned. Bradbury et al. (1964) have concluded exercise has no effect on the course of heat acclimation since increased sweating can be induced by merely heating resting subjects. Preliminary evidence suggests there is a direct relationship between the maximal oxygen uptake and the capacity to maintain thermal regulation, particularly through the control of sweating. Since increased sweating is an important mechanism for the development of heat acclimation, and fit men have high sweat rates, it follows that upon initial exposure to exercise in the heat, men with high maximal oxygen uptakes should exhibit less strain than men with lower maximal oxygen uptakes. The purpose of this study was: (1) to determine if men with higher maximal oxygen uptakes exhibit greater tolerance than men with lower oxygen uptakes during early exposure to exercise in the heat, and (2) to investigate further the mechanism of the relationship between sweating and maximal work capacity.

Greenleaf, J. E.↗

Upper bounds for 21st-century surface air temperatures in the Western United States

The last decade has seen a large number of severe heatwaves that were unprecedented in the observational record, highlighting challenges associated with observationally-based statistical quantification of the likelihood and magnitude of future extreme temperatures. An alternative to such probabilistic assessments is identification of upper bounds that quantify the hottest surface air temperatures that can possibly be achieved by the end of the 21st century. Theory, simulations, and observational analyses support the existence of a finite upper bound for surface air temperature; however, estimates for future upper-bound values that are realistic and usable for planning remain unavailable. Here, we combine atmospheric theory with large ensembles of dynamically downscaled projections to estimate historical and end-of-century upper bounds for surface air temperatures. A number of physical mechanisms can influence upper bounds, and at the end of the 21st century, estimates based on mechanisms that yield more moderate upper-bounds produce values around 60∘C for much of the Western United States and in excess of 80∘C for the hottest parts of the domain. Even cooler high-altitude locations have end-of-century upper bounds over 50∘C. Although these upper-bound estimates might seem implausibly large, increases in the upper bounds over the 21st century are similar to increases in dynamically downscaled peak surface temperatures after adjusting those downscaled temperatures to eliminate the possibly biased model trends in surface specific humidity. While upper bound estimates are high relative to historical observations, they nonetheless suggest that heatwave intensity risk is bounded, with uncertainty dominated by projections of surface and upper-level humidity.

Risser, Mark D↗

Velocity structure functions in multiphase turbulence: interpreting kinematics of Hα filaments in cool-core clusters

ABSTRACT The central regions of cool-core galaxy clusters harbour multiphase gas, with gas temperatures ranging from $10$ to $10^7\, \mathrm{K}$. Feedback from active galactic nuclei jets prevents the gas from undergoing a catastrophic cooling flow. However, the exact mechanism of this feedback energy input is unknown, mainly due to the lack of velocity measurements of the hot-phase gas. However, recent observations have measured the velocity structure functions (VSFs) of the cooler molecular (${\sim} 10\, \mathrm{K}$) and Hα filaments (${\sim} 10^4\, \mathrm{K}$) and used them to indirectly estimate the motions of the hot phase. In the first part of this study, we conduct high-resolution (3843–15363 resolution elements) simulations of homogeneous isotropic subsonic turbulence, without radiative cooling. We analyse the second-order velocity structure functions (VSF2) in these simulations and study the effects of varying spatial resolution, the introduction of magnetic fields, and the effect of projection along the line of sight (LOS) on it. In the second part of the study, we analyse high-resolution (7683 resolution elements) idealized simulations of multiphase turbulence in the intracluster medium from the companion study Mohapatra et al. We compare the VSF2 for both the hot ($T\sim 10^7\, \mathrm{K}$) and cold ($T\sim 10^4\, \mathrm{K}$) phases and find that their amplitude depends on the density contrast between the phases. They have similar scaling with separation, but introducing magnetic fields steepens the VSF2 of only the cold phase. We also find that projection along the LOS steepens the VSF2 for the hot phase and mostly flattens it for the cold phase.

Mohapatra, Rajsekhar (ORCID:0000000216007552)↗

ENG 572 Final Report

Thermo-electric coolers (TECs) provide an essential function in many high-powered applications by diverting heat away from a temperature-sensitive load. This summer I have worked with Sandia National Laboratories in exploring the failure mechanisms behind said devices. I have been tasked with determining a plan of action for two TECs manufactured by two different companies labeled A and B respectively. Prior to my involvement in the project, the former has displayed failures during normal operation within its packaging. The latter was subsequently chosen to resolve these issues. Thermal cycling between the extreme expected operating temperatures (-40°C to 80°C) was applied to 5 unmounted TECAs over a period of 5 hours with 1-hour soaks at each extreme. The unmounted TECBs are currently undergoing the same process, and the task is expected to be completed over the next few weeks. The results of the TECA characterization have indicated no failure has occurred, which indicates that failure will need to be induced through either higher temperature extremes or additional mechanical stress.

47 OTHER INSTRUMENTATION↗

Modeling the ultraviolet photospheric spectrum of cool giant stars. I - Arcturus. II - Gamma Crucis

The UV photospheric spectra of cool giants are modeled analytically to facilitate the identification of UV spectral features and aid in the measurement of actual chromospheric flux at different wavelengths. Atomic line data derived experimentally and semiempirically are used with LTE model atmospheres by means of the SYNTHE FORTRAN code to generate the synthetic spectra. Surface flux spectra are determined and fitted to the absorption features of observed IUE high resolution spectra, and the modeled results are compared to the observed spectra of the cool giants Arcturus and the cooler Gamma Crucis. It is shown that the synthetic spectra can be produced for the stars, and chromospheric emission lines are thought to account for significant discrepancies between observed and calculated values. Two new fluorescence mechanisms are identified by modeling the ultraviolet photospheric spectrum of Gamma Crucis.

Carpenter, Kenneth G.↗

Final Scientific/Technical Report-FREE-piston Zero Emissions Refrigerator (FREEZER)

The FREE-piston Zero Emissions Refrigerator (FREEZER™) is a natural refrigerant Stirling-cycle cooler developed by AMSC in partnership with Heatcraft, targeted as a replacement refrigeration system for walk-in coolers or freezers found commonly in restaurants, convenience stores, supermarkets, etc. The FREEZER™, combined with a closed-loop CO2 heat-transfer system, had the goal to provides an efficient (Target COP = 1.4), zero ODP (Ozone Depletion Potential) and near zero GWP (Global Warming Potential) refrigeration solution with no synthetic, flammable, or toxic refrigerants. Other near zero GWP refrigeration systems do not exist at the scale and performance level of FREEZER. ARPA-E Continuation Funding enabled the design and fabrication of one Advanced Development Unit (ADU) cooler and two Field Test Unit (FTU) coolers, and a new revised Field Test Unit (new FTU). Heatcraft was to extensively test the various coolers at their facilities, which closely simulate real-world conditions. The original plan was to install and operate FREEZER FTUs alongside a traditional cooling solution at one or more customer locations to obtain data on direct performance comparisons with existing commercial refrigeration systems. Success in this FREEZER refinement and field-test project will establish the basis for a new class of environmentally friendly refrigeration systems that will revolutionize the industry. The hardware developed under the program is shown below in Figure 1. Five Stirling-cycle machines were built within the program, with a sixth cooler still under construction. The original DU and the ADU coolers met the performance target with a coefficient of performance (COP) of 1.2. The FTU was underperforming during the initial tuning of the free-piston Stirling cycle dynamics when there was a catastrophic failure of the fasteners on pressure boundary. This caused a pause to the program while the failure mechanism was investigated. The root cause was an inadequate flange design that allowed an excessive cyclic loading on the fasteners, leading to a fatigue failure. It was determined that existing FTU design could not be reasonably salvaged in a safe manner, and that fact, combined with the lower-than-expected performance of the new experimental heat exchanger modules lead to the design of the “new FTU” with a more conventional shell-and-tube heat exchanger design which should get close to the design target COP of 1.4, but have a higher overall machine cost. The program ran out of time before the fabrication of the new FTU was completed, but AMSC is still working on the cooler, with the majority of the parts fabricated, and hopes to have the unit under test sometime in early 2022, after which it will be shipped to Heatcraft for additional testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Report of the sensor cooler technology panel

The Sensor Cooler Technology Panel identified three major areas in which technology development must be supported in order to meet the system performance requirements for the Astrotech 21 mission set science objectives. They are: long life vibration free refrigerators; mechanical refrigeration for 2 K to 5 K; and flight testing of emerging prototype refrigerators. A development strategy and schedule were recommended for each of the three areas.

Ross, Ronald↗

Residual stresses in welded plates

The purpose of this project was to develop a simple model which could be used to study residual stress. The mechanism that results in residual stresses in the welding process starts with the deposition of molten weld metal which heats the immediately adjacent material. After solidification of weld material, normal thermal shrinkage is resisted by the adjacent, cooler material. When the thermal strain exceeds the elastic strain corresponding to the yield point stress, the stress level is limited by this value, which decreases with increasing temperature. Cooling then causes elastic unloading which is restrained by the adjoining material. Permanent plastic strain occurs, and tension is caused in the region immediately adjacent to the weld material. Compression arises in the metal farther from the weld in order to maintain overall static equilibrium. Subsequent repair welds may add to the level of residual stresses. The level of residual stress is related to the onset of fracture during welding. Thus, it is of great importance to be able to predict the level of residual stresses remaining after a weld procedure, and to determine the factors, such as weld speed, temperature, direction, and number of passes, which may affect the magnitude of remaining residual stress. It was hoped to use traditional analytical modeling techniques so that it would be easier to comprehend the effect of these variables on the resulting stress. This approach was chosen in place of finite element methods so as to facilitate the understanding of the physical processes. The accuracy of the results was checked with some existing experimental studies giving residual stress levels found from x-ray diffraction measurements.

Bernstein, Edward L.↗

Coupled hydro-thermal flow and radionuclide transport driven by spatial variation of heat-generating radioactive wastes in shale formations

Deep geologic disposal of multiple nuclear waste packages with various heat sources can induce nonuniform hydro-thermal behaviors in the near-field of the repository, consequently influencing the long-term radionuclide transport in the far-field once waste form breach initiates. Here, this study looks into three cases with variation in the spatial order of six groups of heat sources (10th, 50th, 75th, 90th, 95th, and 99th percentiles of heat outputs generated from 1,981 as-loaded dual-purpose canisters in the field site) in a shale-hosted repository with respect to the uni-directional groundwater flow (from west to east): (1) cooler waste packages from west to east, (2) hotter waste packages from west to east, and (3) hottest waste packages in the middle of the repository. Our field-scale PFLOTRAN simulation represents heat-driven multiphysics coupled mechanisms, including multiphase flow, heat transfer, and chemical/radioactive transport, and also, calculates the onset of waste form breach based on temperature-dependent canister vitality. The results from this sensitivity study will quantify the short- (less than 1 × 10 3 years) and long-term (up to 1 × 10 6 years) impacts of sporadic heat pulses from waste package on the spatio-temporal perturbation in hydro-thermal flow quantities and the rate of radionuclide transport in both near- and far-field of the repository system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Disentangling the Origin and Heating Mechanism of Supernova Dust: Late-Time Spitzer Spectroscopy of the Type IIn SN 2005ip

This paper presents late-time near-infrared and Spitzer mid-infrared photometric and spectroscopic observations of warm dust in the Type IIn SN 2005ip in NGC 2906. The spectra show evidence for two dust components with different temperatures. Spanning the peak of the thermal emission, these observations provide strong constraints on the dust mass, temperature, and luminosity, which serve as critical diagnostics for disentangling the origin and heating mechanism of each component. The results suggest the warmer dust has a mass of approx. 5 x 10(exp -4) Solar Mass and originates from newly formed dust in the ejecta, continuously heated by the circumstellar interaction. By contrast, the cooler component likely originates from a circumstellar shock echo that forms from the heating of a large, pre-existing dust shell approx. 0.01 - 0.05 Solar Mass by the late-time circumstellar interaction. The progenitor wind velocity derived from the blue edge of the He I 1.083 micro P Cygni profile indicates a progenitor eruption likely formed this dust shell approx.100 years prior to the supernova explosion, which is consistent with a Luminous Blue Variable (LBV) progenitor star. Subject

Fox, Ori D.↗

Measurements of soot formation and hydroxyl concentration in near critical equivalence ratio premixed ethylene flame

The testing and development of existing global and detailed chemical kinetic models for soot formation requires measurements of soot and radical concentrations in flames. A clearer understanding of soot particle inception relies upon the evaluation and refinement of these models in comparison with such measurements. We present measurements of soot formation and hydroxyl (OH) concentration in sequences of flat premixed atmospheric-pressure C2H4/O2/N2 flames and 80-torr C2H4/O2 flames for a unique range of equivalence ratios bracketting the critical equivalence ratio (phi(sub c)) and extending to more heavily sooting conditions. Soot volume fraction and number density profiles are measured using a laser scattering-extinction apparatus capable of resolving a 0.1 percent absorption. Hydroxyl number density profiles are measured using laser-induced fluorescence (LIF) with broadband detection. Temperature profiles are obtained from Rayleigh scattering measurements. The relative volume fraction and number density profiles of the richer sooting flames exhibit the expected trends in soot formation. In near-phi(sub c) visibility sooting flames, particle scattering and extinction are not detected, but an LIF signal due to polycyclic aromatic hydrocarbons (PAH's) can be detected upon excitation with an argon-ion laser. A linear correlation between the argon-ion LIF and the soot volume fraction implies a common mechanistic source for the growth of PAH's and soot particles. The peak OH number density in both the atmospheric and 80-torr flames declines with increasing equivalence ratio, but the profile shape remains unchanged in the transition to sooting, implying that the primary reaction pathways for OH remain unchanged over this transition. Chemical kinetic modeling is demonstrated by comparing predictions using two current reaction mechanisms with the atmospheric flame data. The measured and predicted OH number density profiles show good agreement. The predicted benzene number density profiles correlate with the measured trends in soot formation, although anomalies in the benzene profiles for the richer and cooler sooting flames suggest a need for the inclusion of benzene oxidation reactions.

Inbody, Michael Andrew↗

Rotary engine cooling system

A rotary engine has a substantially trochoidal-shaped housing cavity in which a rotor planetates. A cooling system for the engine directs coolant along a single series path consisting of series connected groups of passages. Coolant enters near the intake port, passes downwardly and axially through the cooler regions of the engine, then passes upwardly and axially through the hotter regions. By first flowing through the coolest regions, coolant pressure is reduced, thus reducing the saturation temperature of the coolant and thereby enhancing the nucleate boiling heat transfer mechanism which predominates in the high heat flux region of the engine during high power level operation.

Jones, Charles↗

6 K Cryocooler Program

The report summarizes experimental and theoretical work on an Oxford type Stirling Cycle mechanical precooler operating in the temperature range of 13-20 degrees Kelvin. It includes measurements of the thermal losses of particle regenerators made from lead, and rare earth and rare earth alloys in an operating three stage cryocooler. A 6 K hybrid cooler is designed using the technical information gathered on regenerator performance.

Gully, Willy↗

CO2 response screen in grass Brachypodium reveals the key role of a MAP kinase in CO2-triggered stomatal closure

Abstract Plants respond to increased CO2 concentrations through stomatal closure, which can contribute to increased water use efficiency. Grasses display faster stomatal responses than eudicots due to dumbbell-shaped guard cells flanked by subsidiary cells working in opposition. However, forward genetic screening for stomatal CO2 signal transduction mutants in grasses has yet to be reported. The grass model Brachypodium distachyon is closely related to agronomically important cereal crops, sharing largely collinear genomes. To gain insights into CO2 control mechanisms of stomatal movements in grasses, we developed an unbiased forward genetic screen with an EMS-mutagenized B. distachyon M5 generation population using infrared imaging to identify plants with altered leaf temperatures at elevated CO2. Among isolated mutants, a “chill1” mutant exhibited cooler leaf temperatures than wild-type Bd21-3 parent control plants after exposure to increased CO2. chill1 plants showed strongly impaired high CO2-induced stomatal closure despite retaining a robust abscisic acid-induced stomatal closing response. Through bulked segregant whole-genome sequencing analyses followed by analyses of further backcrossed F4 generation plants and generation and characterization of sodium azide and CRISPR-cas9 mutants, chill1 was mapped to a protein kinase, Mitogen-Activated Protein Kinase 5 (BdMPK5). The chill1 mutation impaired BdMPK5 protein-mediated CO2/HCO3− sensing together with the High Temperature 1 (HT1) Raf-like kinase in vitro. Furthermore, AlphaFold2-directed structural modeling predicted that the identified BdMPK5-D90N chill1 mutant residue is located at the interface of BdMPK5 with the BdHT1 Raf-like kinase. BdMPK5 is a key signaling component that mediates CO2-induced stomatal movements and is proposed to function as a component of the primary CO2 sensor in grasses.

Lopez, Bryn N. K. (ORCID:0009000937288216)↗

Initial comparison of single cylinder Stirling engine computer model predictions with test results

A NASA developed digital computer code for a Stirling engine, modelling the performance of a single cylinder rhombic drive ground performance unit (GPU), is presented and its predictions are compared to test results. The GPU engine incorporates eight regenerator/cooler units and the engine working space is modelled by thirteen control volumes. The model calculates indicated power and efficiency for a given engine speed, mean pressure, heater and expansion space metal temperatures and cooler water inlet temperature and flow rate. Comparison of predicted and observed powers implies that the reference pressure drop calculations underestimate actual pressure drop, possibly due to oil contamination in the regenerator/cooler units, methane contamination in the working gas or the underestimation of mechanical loss. For a working gas of hydrogen, the predicted values of brake power are from 0 to 6% higher than experimental values, and brake efficiency is 6 to 16% higher, while for helium the predicted brake power and efficiency are 2 to 15% higher than the experimental.

Tew, R. C., Jr.↗