Search NASA⌕ Search

SEARCH · Search NASA

Results for “mechanical loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Skeletal adaptation to external loads optimizes mechanical properties: fact or fiction

The skeleton adapts to a changing mechanical environment but the widely held concept that bone cells are programmed to respond to local mechanical loads to produce an optimal mechanical structure is not consistent with the high frequency of bone fractures. Instead, the author suggests that other important functions of bone compete with mechanical adaptation to determine structure. As a consequence of competing demands, bone architecture never achieves an optimal mechanical structure. c2001 Lippincott Williams & Wilkins, Inc.

Review, Tutorial↗

Paxillin localisation in osteocytes-Is it determined by the direction of loading?

External mechanical loading of cells aligns cytoskeletal stress fibres in the direction of principle strains and localises paxillin to the mechanosensing region. If the osteocyte cell body can indeed directly sense matrix strains, then cytoskeletal alignment and distribution of paxillin in osteocytes in situ will bear alignment to the different mechanical loading patterns in fibulae and calvariae. We used confocal microscopy to visualise the immunofluorescence-labelled actin cytoskeleton in viable osteocytes and paxillin distribution in fixated osteocytes in situ. In fibular osteocyte cell bodies, actin cytoskeleton and nuclei were elongated and aligned parallel to the principal (longitudinal) mechanical loading direction. Paxillin was localised to the 'poles' of elongated osteocyte cell bodies. In calvarial osteocyte cell bodies, actin cytoskeleton and nuclei were relatively more round. Paxillin was distributed evenly in the osteocyte cell bodies. Thus in osteocyte cell bodies in situ, the external mechanical loading pattern likely determines the orientation of the actin cytoskeleton, and focal adhesions mediate direct mechanosensation of matrix strains.

60 APPLIED LIFE SCIENCES↗

On the flow induced vibration of an externally excited nuclear reactor experiment

An in-pile, drop-in experiment design is presently being designed and studied for the near-term deployment within the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL); this experiment is termed the Miniplate-1 Large-B (MP-1 LB) Experiment. A number of explicit studies are performed during the design- and safety-related stage. Traditionally, a clear and logical methodology has been developed and utilized for analyses such as hydraulics, thermal-loads, mechanical loads, and others for these experiments. Recently a small component from a different experiment assembly mechanically separated while in the reactor’s core. While this experiment didn’t compromise the safety of the reactor, it led to a higher-level question which centered on whether the appropriate level of consideration was being made toward the fluid–structure-interactions of these experiments. The outcome yielded separate flow test experiments of like-for-like geometry in an experimental loop located at Oregon State University which produces experimental data compliant with applicable parts and requirements to ASME’s NQA-1 2008, 2009a standard – suitable for benchmark evaluation. Here, the objectives of this study are to (1) develop a process for handling and interpreting the mechanical response of the test elements during hydraulic testing, to (2) characterize the motion of a specific test element during a flow test which imposes a wide range of hydraulic conditions, and (3) provide objective observations toward the potential safety related implications that are tied to the synthesized data. The outcome of this study has led to a confident process in inspecting the experimental data, synthesized it for interpretation, identified several unique hydraulic characteristics of the experiment design which were previously unknown, and demonstrated that the likelihood for mechanical failure resulting from fluid-structure-interactions in the reactor is far below any criterion for concern of the element’s safety.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic Characterization of Galfenol (Fe81.6Ga18.4)

Galfenol has the potential to transform the smart materials industry by allowing for the development of multifunctional, load-bearing devices. One of the primary technical challenges faced by this development is the very limited experimental data on Galfenol's frequency-dependent response to dynamic stress, which is critically important for the design of such devices. This report details a novel and precise characterization of the constitutive behavior of polycrystalline Galfenol (Fe81.6Ga18.4) under quasi-static (1 Hz) and dynamic (4 to 1000 Hz) stress loadings. Mechanical loads are applied using a high-frequency load frame. Quasi-static minor and major hysteresis loop measurements of magnetic flux density and strain are presented for constant electromagnet currents (0 to 1.1 A) and constant magnetic fields 0 to 14 kA/m (0 to 180 Oe). The dynamic stress amplitude for minor and major loops is 2.88 and 31.4 MPa (418 and 4550 psi), respectively. Quasi-static material properties closely match published values for similar Galfenol materials. Quasi-static actuation responses are also measured and compared to quasi-static sensing responses; the high degree of reversibility seen in the comparison is consistent with published measurements and modeling results. Dynamic major and minor loops are measured for dynamic stresses up to 31 MPa (4496 psi) and 1 kHz, and the bias condition resulting in maximum, quasi-static sensitivity. Eddy current effects are quantified by considering solid and laminated Galfenol rods. Three key sources of error in the dynamic measurements are accounted for: (1) electromagnetic noise in strain signals due to Galfenol's magnetic response, (2) error in load signals due to the inertial force of fixturing, and (3) phase misalignment between signals due to conditioning electronics. For dynamic characterization, strain error is kept below 1.2 percent of full scale by wiring two collocated gauges in series (noise cancellation) and through leadwire weaving. Inertial force error is kept below 0.41 percent by measuring the dynamic force in the specimen using a nearly collocated piezoelectric load washer. The phase response of all conditioning electronics is explicitly measured and corrected for. In general, as frequency is increased, the sensing response becomes more linear because of an increase in eddy currents. As frequency increases above approximately 100 Hz, the elbow in the strain-versus-stress response disappears as the active (soft) regime stiffens toward the passive (hard) regime. Under constant-field conditions, the loss factors of the solid rod peak between 200 and 600 Hz, rather than exhibiting a monotonic increase. Compared to the solid rod, the laminated rod exhibits much slower increases in hysteresis with frequency, and its quasi-static behavior extends to higher frequencies. The elastic modulus of the laminated rod decreases between 100 and 300 Hz; this trend is currently unexplained.

Dynamic sensing↗

The Role of Adaptation in Body Load-Regulating Mechanisms During Locomotion

Body loading is a fundamental parameter that modulates motor output during locomotion, and is especially important for controlling the generation of stepping patterns, dynamic balance, and termination of locomotion. Load receptors that regulate and control posture and stance in locomotion include the Golgi tendon organs and muscle spindles at the hip, knee, and ankle joints, and the Ruffini endings and the Pacinian corpuscles in the soles of the feet. Increased body weight support (BWS) during locomotion results in an immediate reorganization of locomotor control, such as a reduction in stance and double support duration and decreased hip, ankle, and knee angles during the gait cycle. Previous studies on the effect during exposure to increased BWS while walking showed a reduction in lower limb joint angles and gait cycle timing that represents a reorganization of locomotor control. Until now, no studies have investigated how locomotor control responds after a period of exposure to adaptive modification in the body load sensing system. The goal of this research was to determine the adaptive properties of body load-regulating mechanisms in locomotor control during locomotion. We hypothesized that body load-regulating mechanisms contribute to locomotor control, and adaptive changes in these load-regulating mechanisms require reorganization to maintain forward locomotion. Head-torso coordination, lower limb movement patterns, and gait cycle timing were evaluated before and after a 30-minute adaptation session during which subjects walked on a treadmill at 5.4 km/hr with 40% body weight support (BWS). Before and after the adaptation period, head-torso and lower limb 3D kinematic data were obtained while performing a goal directed task during locomotion with 0% BWS using a video-based motion analysis system, and gait cycle timing parameters were collected by foot switches positioned under the heel and toe of the subjects shoes. Subjects showed adaptive modification in the body load-regulating mechanisms that included increased head movement amplitude, increased knee and ankle flexion, and increased stance, stride, and double support time, with no change in the performance of the task with respect to that measured before exposure to BWS. These changes in locomotor control are opposite to that reported during 40% BWS exposure and indicative of an after-effect after removal of the adaptive stimulus. Therefore, it is evident that just 30 minutes of 40% BWS during locomotion was sufficient to induce adaptive modifications in the body load sensing systems that contribute to reorganization of sensory contributions to stable locomotor control.

Ruttley, Tara↗

High-bandwidth Dynamic Load Emulation of Mechanical Systems using Electric Drives

Machine drives are versatile systems that can be programmed to emulate a variety of mechanical loads. In this paper, we walk through the modeling and control framework of a shaft-coupled dual-motor drive system that is programmed to emulate a fictitious mechanical system. We quantitatively evaluate the control performance of such a system and derive a theoretical limit that explains its inaccuracy at high operating frequencies. To overcome this problem, we propose an alternate control structure that achieves the same control objective at high frequencies as well. After suitable adjustments are made to the controller, we validate its performance using simulation results.

machine drives ,load emulation, speed-torque chara↗

Nonuniform thermal environmental effects on space truss structural reliability

A three-bay, space, cantilever truss is probabilistically evaluated to quantify the range of uncertainties of buckling loads and member forces due to nonuniform thermal loads, applied loads and moments (mechanical loads), and combination of both. The truss members are assumed to be made from (1) aluminum tubes or (2) high modulus graphite-fiber/intermediate modulus epoxy-matrix composite tubes. Cumulative distribution function results show that certain combinations of thermal loads with mechanical loads reduce the probabilistic buckling loads and increase the magnitude of the member axial forces for aluminum truss. However, the reverse is true for composite truss due to very low coefficient of thermal expansion and higher stiffness of the composite. Finally, the sensitivities associated with the uncertainties in the structural, material, and load variables (primitive variables) are investigated. They show that buckling loads and member axial forces are most sensitive to the uncertainties in spacial (geometry) variables.

Pai, Shantaram S.↗

Probabilistic structural analysis of space truss structures for nonuniform thermal environmental effects

A three-bay, space, cantilever truss is probabilistically evaluated to quantify the range of uncertainties of vibration frequencies and truss free end vertical displacements due to nonuniform thermal loads, applied loads and moments (mechanical loads), and combination of both. The truss members are assumed to be made from (1) aluminum tubes or (2) high modulus graphite-fiber/intermediate modulus epoxy-matrix composite tubes. Cumulative distribution function results show that certain combination of thermal loads with mechanical loads reduce the probabilistic vibration frequencies and increase the magnitude of the truss free end vertical displacements for the aluminum truss. However, for the composite truss, the thermal effects on the probabilistic vibration frequencies are not as substantial as that for an aluminum truss. This can be attributed to the large differences in the values of coefficient of thermal expansion. Finally, the sensitivities associated with the uncertainties in the structural, material and load variables (primative variables) are investigated. Results indicate that vibration frequencies and truss free end vertical displacements are sensitive to the uncertainties in spacial (geometry) variables as well as member modulus.

Pai, Shantaram S.↗

Numerical simulation of effective mechanical properties of stochastic composites with consideration for structural evolution under intensive dynamic loading

Mechanical behavior of stochastic metal-ceramic composites with the aluminum matrix under high-rate deformation at shock-wave loading is numerically simulated with consideration for structural evolution. Effective values of mechanical parameters of metal-ceramic composites Al B{sub 4}C, Al SiC, and Al Al{sub 2}O{sub 3} are evaluated depending on different concentration of ceramic inclusions.

36 MATERIALS SCIENCE↗

Allowable bending loads for mechanical fasteners

Modified shear-loading setup is used to determine allowable shear bending loads on mechanical fasteners. System reduces number of tests required for direct analysis of fasteners to two.

Ferdie, R. D.↗

Probabilistic assessment of space trusses subjected to combined mechanical and thermal loads

A three-bay, space, cantilever truss is probabilistically evaluated to quantify the range of uncertainties of buckling loads and member forces due to nonuniform thermal loads, applied loads and moments (mechanical loads), and combination of both. The truss members are assumed to be made from Aluminum tubes or high modulus graphite-fiber/intermediate modulus epoxy-matrix composite tubes. Cumulative distribution function results show that certain combinations of thermal loads with mechanical loads reduce the probabilistic buckling loads and increase the magnitude of the member axial forces for the aluminum truss. The same trend is observed for the composite truss as well, as however, the thermal effects on the probabilistic buckling loads and member axial forces are not as substantial as that for an aluminum truss. This can be attributed to the large differences in the values of coefficient of thermal expansion. Finally, the sensitivities associated with the uncertainties in the structural, material, and load variables (primitive variables) are investigated. They show that buckling loads and member axial forces are most sensitive to the uncertainties in spacial (geometry) variables.

Pai, Shantaram S.↗

Shock Loading of Granular Ni/Al Composites. Part 1. Mechanics of Loading

We present molecular dynamics simulations of the thermomechanical response under shock loading of a granular material consisting of laminated Ni/Al grains. We observe two regimes: At low piston velocities (up ≲ 1km/s), the shock wave is diffuse, and the width of the shock front decreases with increasing piston velocity. Beyond a critical shock strength, however, the width remains relatively constant at approximately the mean grain radius. This change in behavior follows from an evolution of the mechanism of compaction with increasing insult strength. Furthermore, the mechanism evolves from plastic deformation-mediated pore collapse for relatively weak shocks, to solid extrusion and fluid ejecta filling pores ahead of the shock front at intermediate strengths, and finally to atomic jetting into the pore for very strong shocks (up ≳ 2 km/s). High-energy fluid ejecta into pores leads to the formation of flow vorticity and can result in a large fraction of the input energy localizing into translational kinetic energy components including the formation of hot spots. This has implications for the mechanical mixing of Ni and Al in these reactive composites.

36 MATERIALS SCIENCE↗

Mechanics of load transfer at the interface

The mechanism of load transfer from matrix to fiber though the interface and, as a consequence, the effects of the interface on composite structural integrity are discussed. Specifically, the present work deals with the role of interfacial bonding in composite strength, the dependence of fracture surface on interface bond strength, and methods of measuring and predicting the stress at the interface, the microresidual stress, and load condition effects on the interface bond. The possibility of designing composites with specified bond properties is examined. Many of these effects are illustrated graphically to indicate general trends and to illustrate significant points. The discussion is based on theoretical considerations and is supplemented with pertinent experimental data.

Chamis, C. C.↗

Electro-Thermo-Mechanical (ETM) Study on Submarine Dynamic Power Cables (SDPC) for Offshore Wind Transmission

Understanding the failure mechanisms of submarine dynamic power cables (SDPC) is critical for innovative design to meet the 2035 cost reduction target of U.S. DOE Floating Offshore Wind Shot. This is important because the current design suffers a significant failure rate in the field. This project conducted a systematic electro-thermo-mechanical (ETM) experimental study on the power cores extracted from a 15kV power cable with three cores of copper conductor, ethylene propylene rubber (EPR) insulation, and continuously corrugated welded aluminum armor (CCWA). An ETM testing system was developed by integrating a high voltage (HV) amplifier, two ceramic heaters, and a rod-plate transverse compression setup into a mechanical testing machine. Increasing temperature from room temperature (RT, 22 degree C) to 90 degree C resulted in the 67% decrease in the failure mechanical load as defined by the dielectric breakdown. Under creep mechanical loading, the dielectric breakdown time was decreased by 70% for a given mechanical load when the specimen temperature increased from RT to 90oC. The failure strain in both monotonic and creep mechanical loading modes was related to the maximum mechanical load applied. Although the dielectric breakdown occurred in the ETM test, the post-test measurement revealed an impressive recovery of electric resistance. The failure analysis on cross section of tested specimens indicated a sizable gap across insulation layer near the area between copper conductor and loading rod, which apparently resulted from online dielectric failure and offline elastic recovery of components including conductor and insulation layer.

17 WIND ENERGY↗

Mechanism isolates load weighing cell during lifting of load

Load weighing cell used in conjuction with a hoist is isolated during lifting and manipulation of the load. A simple mechanism, attached to a crane hook, provides a screw adjustment for engaging the load cell during weighing of the load and isolating it from lift forces during hoisting of the load.

Haigler, J. S.↗