Search NASA⌕ Search

SEARCH · Search NASA

Results for “medical capabilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Analysis of RF high power sources for 1MW – range, 10 MeV CW industrial accelerator.

Cobalt-60 is the dominant source of ionizing radiation for sterilizing products in the $200B/year medical device industry. Security and accessibility concerns around this radioactive material - sourced from countries including Russia and China - present national security and economic risks. There is a continued national urgency to replace such high-risk sources with low-risk alternatives such as electron or x-ray beams driven by accelerators. While e-beam sources have been in use for many years, they still represent a small portion of the market. X-ray sources are becoming economical alternatives. Meeting the processing capacity required to replace Co-60 requires a step-change in the capability, efficiency, and overall operating cost of electron accelerators to make adoption feasible. The radiofrequency (RF) power that drives accelerating cavities represents significant capital and operating costs for these accelerators. For accelerator-based systems to be a viable alternative for these applications, RF systems must be economical to manufacture, deploy, and operate.

43 PARTICLE ACCELERATORS↗

Small animal PET: a review of what we have done and where we are going

Abstract Small animal research is an essential tool in studying both pharmaceutical biodistribution and disease progression over time. Furthermore, through the rapid development of in vivo imaging technology over the last few decades, small animal imaging (also referred to as preclinical imaging) has become a mainstay for all fields of biologic research and a center point for most preclinical cancer research. Preclinical imaging modalities include optical, MRI and MRS, microCT, small animal PET, ultrasound, and photoacoustic, each with their individual strengths. The strong points of small animal PET are its translatability to the clinic; its quantitative imaging capabilities; its whole-body imaging ability to dynamically trace functional/biochemical processes; its ability to provide useful images with only nano- to pico- molar concentrations of administered compounds; and its ability to study animals serially over time. This review paper gives an overview of the development and evolution of small animal PET imaging. It provides an overview of detector designs; system configurations; multimodality PET imaging systems; image reconstruction and analysis tools; and an overview of research and commercially available small animal PET systems. It concludes with a look toward developing technologies/methodologies that will further enhance the impact of small animal PET imaging on medical research in the future.

Engineering↗

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Neutrons have historically been used for a broad range of biological applications employing techniques such as small-angle neutron scattering, neutron spin echo, diffraction, and inelastic scattering. Unlike neutron scattering techniques that obtain information in reciprocal space, attenuation-based neutron imaging measures a signal in real space that is resolved on the order of tens of micrometers. The principle of neutron imaging follows the Beer-Lambert law and is based on the measurement of the bulk neutron attenuation through a sample. Greater attenuation is exhibited by some light elements (most notably, hydrogen), which are major components of biological samples. Contrast agents such as deuterium, gadolinium, or lithium compounds can be used to enhance contrast in a similar fashion as it is done in medical imaging, including techniques such as optical imaging, magnetic resonance imaging, X-ray, and positron emission tomography. For biological systems, neutron radiography and computed tomography have increasingly been used to investigate the complexity of the underground plant root network, its interaction with soils, and the dynamics of water flux in situ. Moreover, efforts to understand contrast details in animal samples, such as soft tissues and bones, have been explored. This manuscript focuses on the advances in neutron bioimaging such as sample preparation, instrumentation, data acquisition strategy, and data analysis using the High Flux Isotope Reactor CG-1D neutron imaging beamline. The aforementioned capabilities will be illustrated using a selection of examples in plant physiology (herbaceous plant/root/soil system) and biomedical applications (rat femur and mouse lung).

Bilheux, Hassina↗

Gas Ingress and Egress of MEMS Multi-Chip Modules and MEMS Devices

Hermetic microcircuit packaging was the dominant method of protecting semiconductor devices in the 1960s and 1970s. After losing majority market sectors to plastic encapsulated microelectronics over the last a few decades, hermetic packaging remains the preferred method of protecting semiconductor devices for critical applications such as in military, space, and medical fields, where components and systems are required to serve for several decades. MEMS devices impose additional challenges to packaging by requiring specific internal cavity pressures to function properly or deliver the needed quality (Q) factors. In MEMS multichip modules, internal pressure requirement conflicts arise when different MEMS devices require different internal gases and pressures. The authors developed a closed-formed equation to model pressure changes of hermetic enclosures due to gas ingression. This article expands the authors mathematical model to calculate gas pressure of a MEMS multichip module package as well as those of MEMS devices inside the multichip module package. These equations are not only capable of calculating service lifetimes of MEMS devices and multi-chip modules but can also help develop MEMS device packaging strategies to extend the service life of MEMS multi-chip modules.

36 MATERIALS SCIENCE↗

Porous Polymer Structures with Tunable Mechanical Properties Using a Water Emulsion Ink

Recently, the manufacturing of porous polydimethylsiloxane (PDMS) with engineered porosity has gained considerable interest due to its tunable material properties and diverse applications. An innovative approach to control the porosity of PDMS is to use transient liquid phase water to improve its mechanical properties, which has been explored in this work. Adjusting the ratios of deionized water to the PDMS precursor during blending and subsequent curing processes allows for controlled porosity, yielding water emulsion foam with tailored properties. The PDMS-to-water weight ratios were engineered ranging from 100:0 to 10:90, with the 65:35 specimen exhibiting the best mechanical properties with a Young’s Modulus of 1.17 MPa, energy absorption of 0.33 MPa, and compressive strength of 3.50 MPa. This led to a porous sample exhibiting a 31.46% increase in the modulus of elasticity over a bulk PDMS sample. Dowsil SE 1700 was then added, improving the storage capabilities of the precursor. The optimal storage temperature was probed, with -60 °C resulting in great pore stability throughout a three-week duration. The possibility of using these water emulsion foams for paste extrusion additive manufacturing (AM) was also analyzed by implementing a rheological modifier, fumed silica. Fumed silica’s impact on viscosity was examined, revealing that 9 wt% of silica demonstrates optimal rheological behaviors for AM, bearing a viscosity of 10,290 Pa·s while demonstrating shear-thinning and thixotropic behavior. This study suggests that water can be used as pore-formers for PDMS in conjunction with AM to produce engineered materials and structures for aerospace, medical, and defense industries as sensors, microfluidic devices, and lightweight structures.

36 MATERIALS SCIENCE↗

Lighting Control in Patient Rooms: Understanding Nurses’ Perceptions of Hospital Lighting Using Qualitative Methods

Here, this study differs in its methodological approach from previously published research by interpreting qualitative results against existing literature to understand how nurses conceptualize medical–surgical patient rooms as productive settings in relation to lighting, as well as the ways in which nurses believe these spaces could be enhanced for patient satisfaction. Content analysis was used to interpret themes emerging from nurses’ subjective responses to open-ended items. Three of the facilities had older, traditional lighting systems; one had a contemporary framework. A theme of environmental control over both overhead and task lighting emerged from data from all items. Although controllability was among the “best” lighting attributes, more refinement is necessary for optimal staff productivity and patient satisfaction. Daylighting was also considered to be among the best attributes. Control over light level via additional dimming capability for patients, as well as additional light sources, was prominent across the four hospitals. Unique to the more modern facility, trespassing of light was problematic for nurses considering the experiences of patients—even where modern models exist, more attention can be paid to the ways in which window shades, and light sources outside of rooms, penetrate spaces and affect users. Finally, the finding that nurses and patients desire greater control over the lighting in patient rooms is consistent with Ulrich’s theory of supportive design for healthcare and coincides with advances in lighting technology. Despite differences in the level of sophistication in lighting among the four facilities, control continues to be a primary concern for nurses.

60 APPLIED LIFE SCIENCES↗

Nuclear excitation functions for medical isotope production: Targeted radionuclide therapy via nat IR$(d, x)$ 193m Pt

193m Pt is an Auger emitting radionuclide which may have therapeutic potential, particularly when labeled to the chemotherapeutic drug cisplatin. One challenge to broader explorations of its clinical potential is the need for production routes with high specific activity. As part of a larger campaign to address gaps in reaction data for emerging medical radionuclides, this work seeks to characterize the nat Ir(d,x) reactions as a potential production pathway for 193m Pt. A stacked target irradiation, consisting of natural iridium, iron, nickel, and copper foils, was performed using a 33 MeV deuteron beam at the Lawrence Berkeley National Laboratory 88-Inch Cyclotron. This measurement, along with previous experimental data, suggests an energy window between 11 to 18 MeV to maximize the production and radiopurity of 193m Pt. This experiment has yielded cross sections for 43 channels of deuteron-induced reactions from threshold to 30 MeV, including the first experimental results of nat Ir(d,x) 188m1+g,190m1+g Ir (cumulative), nat Ni(d,x) 56,57,58 m,58g Co (independent), nat Cu(d,x) 61 Co (cumulative) and nat Fe(d,x) 53 Fe, 48 V (cumulative). The results were compared with literature data, the TENDL-2023 database, and default theoretical calculations from the TALYS-2.04, CoH-3.6.0, EMPIRE 3.2.3, and ALICE-2020 reaction modeling codes. Here, this work presents another example of the lack of predictive capabilities for this set of modern nuclear-reaction modeling codes, and highlights the unsatisfactory modeling of experimental cross sections. Experimental data are important to improve the codes in general, and new experimental results can be used to improve the models. Finally, this measurement has revealed the need for an updated evaluation of the nat Cu(d,x) 63 Zn deuteron monitor reaction.

193mPt↗

Patterned anodes with sub-millimeter spatial resolution for large-area MCP-based photodetector systems

Micro-channel-plate-based photo-detectors are unique in being capable of covering very large areas such as those required in elementary particle and nuclear physics, while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, and time resolutions of 30 psec–50 psec for single photons. In such systems the electronic channel count is a major cost driver. Incorporating a capacitively-coupled anode allows the use of external pickup electrodes with patterns of individual channels optimized for occupancy, rate, and time/space resolution. The signal pickup antenna can be economically implemented as a printed circuit card with a 2-dimensional array of pads for high-occupancy/high-rate applications such as in particle colliders and medical imaging, or a 1-dimensional array of strips for a lower channel count in low-occupancy/low-rate applications such as large neutrino detectors. In this paper we present pad patterns that enhance signal-sharing between pads to lower the channel count per unit area in large-area systems by factors up to 4, while maintaining spatial resolutions of approximately 100 to 200 μ m for charged particles and 400 to 1000 μ m for single photons. Patterns that use multiple signal layers in the signal-pickup board can lower the channel count even further, moving the scaling behavior in the number of pads versus total area from quadratic to linear.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Glycosyl transferase GT2 genes mediate the biosynthesis of an unusual (1,3;1,4)‐β‐glucan exopolysaccharide in the bacterium Sarcina ventriculi

Abstract Linear, unbranched (1,3;1,4)‐β‐glucans (mixed‐linkage glucans or MLGs) are commonly found in the cell walls of grasses, but have also been detected in basal land plants, algae, fungi and bacteria. Here we show that two family GT2 glycosyltransferases from the Gram‐positive bacteriumSarcina ventriculiare capable of synthesizing MLGs. Immunotransmission electron microscopy demonstrates that MLG is secreted as an exopolysaccharide, where it may play a role in organizing individual cells into packets that are characteristic ofSarcinaspecies. Heterologous expression of these two genes shows that they are capable of producing MLGsin planta, including an MLG that is chemically identical to the MLG secreted fromS. ventriculicells but which has regularly spaced (1,3)‐β‐linkages in a structure not reported previously for MLGs. The tandemly arranged, paralogous pair of genes are designatedSvBmlgs1andSvBmlgs2. The data indicate that MLG synthases have evolved different enzymic mechanisms for the incorporation of (1,3)‐β‐ and (1,4)‐β‐glucosyl residues into a single polysaccharide chain. Amino acid variants associated with the evolutionary switch from (1,4)‐β‐glucan (cellulose) to MLG synthesis have been identified in the active site regions of the enzymes. The presence of MLG synthesis in bacteria could prove valuable for large‐scale production of MLG for medical, food and beverage applications.

Biochemistry & Molecular Biology↗

Proton-induced reactions on Fe, Cu, and Ti from threshold to 55 MeV

Theoretical models often differ significantly from measured data in their predictions of the magnitude of nuclear reactions that produce radionuclides for medical, research, and national security applications. In this paper, we compare a priori predictions from several state-of-the-art reaction modeling packages (CoH, EMPIRE, TALYS, and ALICE) to cross sections measured using the stacked-target activation method. The experiment was performed using the Lawrence Berkeley National Laboratory 88-Inch Cyclotron with beams of 25 and 55 MeV protons on a stack of iron, copper, and titanium foils. Thirty-four excitation functions were measured from 4–55 MeV, including the first measurement of the independent cross sections for nat Fe(p,x) 49,51 Cr, 51,52m,52g,56 Mn, and 58m,58g Co. All of the models, using default input parameters to assess their predictive capabilities, failed to reproduce the isomer-to-ground state ratio for reaction channels at compound and pre-compound energies, suggesting issues in modeling the deposition or distribution of angular momentum in these residual nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Novel design and diagnostics improvements for increased production capacity and improved reliability at the Los Alamos Isotope Production Facility

The Isotope Production Facility (IPF) at Los Alamos National Laboratory (LANL) is used to produce an array of isotopes for medical, global security, and research applications with an intense beam of protons supplied by the linear accelerator at the Los Alamos Neutron Science Center (LANSCE). An Accelerator Improvement Project (AIP) was recently conducted at IPF to improve facility reliability and reduce programmatic risk while increasing general isotope production capacity and flexibility. This was accomplished through the installation of an improved beam window assembly, more robust beam diagnostics, an active and adjustable collimator, and a new beam rastering system. This paper will highlight the four exciting innovations and how they were designed, validated, and installed in parallel as well as the significant operational advantages they provide to IPF. Key experiments and the increased currents achieved in routine production runs demonstrating the enhanced capability from the AIP will be presented. As a result, the most notable capability enhancements include irradiations with beam currents ranging from 100 nA experimental runs up to 300 μA on routine production targets and utilization of a range of cylindrical target diameters.

100 MeV protons↗

Methanobactin from methanotrophs: genetics, structure, function and potential applications

ABSTRACT Aerobic methane-oxidizing bacteria of the Alphaproteobacteria have been found to express a novel ribosomally synthesized post-translationally modified polypeptide (RiPP) termed methanobactin (MB). The primary function of MB in these microbes appears to be for copper uptake, but MB has been shown to have multiple capabilities, including oxidase, superoxide dismutase and hydrogen peroxide reductase activities, the ability to detoxify mercury species, as well as acting as an antimicrobial agent. Herein, we describe the diversity of known MBs as well as the genetics underlying MB biosynthesis. We further propose based on bioinformatics analyses that some methanotrophs may produce novel forms of MB that have yet to be characterized. We also discuss recent findings documenting that MBs play an important role in controlling copper availability to the broader microbial community, and as a result can strongly affect the activity of microbes that require copper for important enzymatic transformations, e.g. conversion of nitrous oxide to dinitrogen. Finally, we describe procedures for the detection/purification of MB, as well as potential medical and industrial applications of this intriguing RiPP.

54 ENVIRONMENTAL SCIENCES↗

Bioscience COVID Rapid Response Report

The COVID-19 disease outbreak and its impact on global health and economies have highlighted the national security threat posed by pathogens with pandemic potential and the need for rapid development of effective diagnostics and medical countermeasures. The Bioscience IA selected for funding rapid COVID LDRD project proposals that addressed critical R&D gaps in pandemic response that could be accomplished in 1-3 months with the requested funding. In total, the Bioscience IA funded nine rapid projects that addressed 1) rapid and accurate methods for SARS-CoV-2 RNA detection, 2) modeling tools to help prioritize populations for diagnostic testing, 3) bioinformatic tools to track SARS-CoV-2 genomic sequence changes over time, 4) molecular inhibitors of SARS-CoV-2 cellular infection, and 5) method for rapid staging of COVID19 disease to enable administration of more effective treatments. In addition, LDRD funded one larger project to be completed in FY21 that leverages Sandia capabilities to address the need for platform diagnostics and therapeutics that can be rapidly tailored against emerging pathogen targets.

59 BASIC BIOLOGICAL SCIENCES↗

Millimeter-Thick Liquid Crystalline Elastomer Actuators Prepared by-Surface-Enforced Alignment

Here, liquid crystalline elastomers (LCE) are thermally cyclable, compliant actuators with compelling mechanical properties. The large and programmable deformation of LCE has led to numerous functional examinations spanning optics, medical devices, and robotics. A well-established method to prepare complex LCE actuators is to utilize surface-enforced photoalignment. Herein, a facile and scalable approach is reported to circumvent the physical limits of surface-enforced alignment (e.g., samples that are 50 µm or less) to amplify the achievable force output in LCE. Applying an approach termed direct layering, the thermomechanical response of LCE elements prepared with +1 disclination patterns in a range of compositions and thicknesses is contrasted. The design and preparation of +1 disclination patterns and arrays is explored to assess the contribution of sample geometry and overlap to deformation and force output. The methodology detailed in this contribution allows for the preparation of elements ≈1 mm in thickness that are capable of actuating large objects. Furthermore, the fabrication of these elements uniquely enables the realization of mechanical instabilities to hasten the actuation rate in response to thermal change and to enable leaping.

36 MATERIALS SCIENCE↗

SRF Resonators for a bi-directional Energy Ramping Upgrade of the Isotope Production Facility Beamline at LANL

The LANL Isotope Production Facility (IPF) is one of the two high-current proton linear accelerators operated under the auspices of the DOE Office of Nuclear Physics Isotope Development and Production for Research Applications Program. The IPF beamline operates with a fixed 100-MeV energy proton beam, diverted from the LANSCE accelerator and guided towards the isotope production target station. The fixed beam energy limits the number of isotopes that can be produced at IPF, and adversely affects the purity of isotopes produced at non-optimal energies. In particular, the IPF program is receiving increasing numbers of requests for high purity isotopes such as Np-236 (national security applications) and Re-186 (medical therapy). These are typically produced via (p,n) and (p,2n) nuclear reactions, requiring very tight control of the incident energies on the production targets to ensure an end product with a high radionuclidic purity. It is well known that this level of energy control cannot be achieved when a 100 MeV beam of mono-energetic protons is degraded to the required energies, typically below 30 MeV, as too much energy spread is acquired. Operating the IPF beamline at lower, mono-energetic beam energies such as at 40 MeV will allow the required tight energy control in target assemblies to ensure a high purity product. In addition, NP has requested a LANL/BNL/ORNL collaboration focus on establishing a national large-scale production capability for the therapy isotope Ac-225. Recent nuclear cross section measurements done at LANL show that due to a steep rise in production cross section towards higher proton energies (See Figure 2), proton beams at energies substantially greater than 100 MeV will be highly beneficial for Ac-225 production [AC255]. Such higher-energy beams cannot be delivered to IPF at present. Lower-energy beams (70 MeV and 40 MeV) can be delivered but only in sole-use mode; all other LANSCE users must be offline during 70 MeV or 40 MeV operation.

07 ISOTOPE AND RADIATION SOURCES↗

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Platform for Ultra-Fast Proton Probing of Matter in Extreme Conditions

Recent developments in ultrashort and intense laser systems have enabled the generation of short and brilliant proton sources, which are valuable for studying plasmas under extreme conditions in high-energy-density physics. However, developing sensors for the energy selection, focusing, transport, and detection of these sources remains challenging. This work presents a novel and simple design for an isochronous magnetic selector capable of angular and energy selection of proton sources, significantly reducing temporal spread compared to the current state of the art. The isochronous selector separates the beam based on ion energy, making it a potential component in new energy spectrum sensors for ions. Analytical estimations and Monte Carlo simulations validate the proposed configuration. Due to its low temporal spread, this selector is also useful for studying extreme states of matter, such as proton stopping power in warm dense matter, where short plasma stagnation time (<100 ps) is a critical factor. The proposed selector can also be employed at higher proton energies, achieving final time spreads of a few picoseconds. This has important implications for sensing technologies in the study of coherent energy deposition in biology and medical physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acoustics at the nanoscale (nanoacoustics): A comprehensive literature review. Part II: Nanoacoustics for biomedical imaging and therapy

We report in the past decade, acoustics at the nanoscale (i.e., nanoacoustics) has evolved rapidly with continuous and substantial expansion of capabilities and refinement of techniques. Motivated by research innovations in the last decade, for the first time, recent advancements of acoustics-associated nanomaterials/nanostructures and nanodevices for different applications are outlined in this comprehensive review, which is written in two parts. As part II of this two-part review, this paper concentrates on nanoacoustics in biomedical imaging and therapy applications, including molecular ultrasound imaging, photoacoustic imaging, ultrasound-mediated drug delivery and therapy, and photoacoustic drug delivery and therapy. Firstly, the recent developments of nanosized ultrasound and photoacoustic contrast agents as well as their various imaging applications are examined. Secondly, different types of nanomaterials/nanostructures as nanocarriers for ultrasound and photoacoustic therapies are discussed. Finally, a discussion of challenges and future research directions are provided for nanoacoustics in medical imaging and therapy.

47 OTHER INSTRUMENTATION↗