Search NASA⌕ Search

SEARCH · Search NASA

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A Modified Sequence-to-point HVAC Load Disaggregation Algorithm

This paper presents a modified sequence-to-point (S2P) algorithm for disaggregating the heat, ventilation, and air conditioning (HVAC) load from the total building electricity consumption. The original S2P model is convolutional neural network (CNN) based, which uses load profiles as inputs. We propose three modifications. First, the input convolution layer is changed from 1D to 2D so that normalized temperature profiles are also used inputs to the S2P model. Second, a drop-out layer is added to improve adaptability and generalizability so that the model trained in one area can be transferred to other geographical areas without labelled HVAC data. Third, a fine-tuning process is proposed for areas with a small amount of labelled HVAC data so that the pre-trained S2P model can be fine-tuned to achieve higher disaggregation accuracy (i.e., better transferability) in other areas. The model is first trained and tested using smart meter and sub-metered HVAC data collected in Austin, Texas. Then, the trained model is tested on two other areas: Boulder, Colorado and San Diego, California. Simulation results show that the proposed modified S2P algorithm outperforms the original S2P model and the support-vector machine based approach in accuracy, adaptability, and transferability.

Ye, Kai↗

New Cryogenic Optical Test Capability at Marshall Space Flight Center's Space Optics Manufacturing Technology Center

A new cryogenic optical testing capability exists at Marshall Space Flight Center's Space Optics Manufacturing Technology Center (SOMTC). SOMTC has been performing optical wavefront testing at cryogenic temperatures since 1999 in the X-ray Cryogenic Test Facility's (XRCF's) large vacuum chamber. Recently the cryogenic optical testing capability has been extended to a smaller vacuum chamber. This smaller horizontal cylindrical vacuum chamber has been outfitted with a helium-cooled liner that can be connected to the facility's helium refrigeration system bringing the existing kilowatt of refrigeration capacity to bear on a 1 meter diameter x 2 meter long test envelope. Cryogenic environments to less than 20 Kelvin are now possible in only a few hours. SOMTC's existing instruments (the Instantaneous Phase-shifting Interferometer (IPI) from ADE Phase-Shift Technologies and the PhaseCam from 4D Vision Technologies) view the optic under test through a 150 mm clear aperture BK-7 window. Since activation and chamber characterization tests in September 2001, the new chamber has been used to perform a cryogenic (less than 30 Kelvin) optical test of a 22.5 cm diameter x 127 cm radius of curvature SiO2 mirror, a cryogenic survival (less than 30 Kelvin) test of an adhesive, and a cryogenic cycle (less than 20 Kelvin) test of a ULE mirror. A vibration survey has also been performed on the test chamber. Chamber specifications and performance data, vibration environment data, and limited test results will be presented.

Kegley, Jeff↗

New Cryogenic Optical Test Capability at Marshall Space Flight Center's Space Optics Manufacturing Technology Center

A new cryogenic optical testing capability exists at Marshall Space Flight Center's Space Optics Manufacturing Technology Center (SOMTC). SOMTC has been performing optical wavefront testing at cryogenic temperatures since 1999 in the X-ray Cryogenic Test Facility's (XRCF's) large vacuum chamber. Recently the cryogenic optical testing capability has been extended to a smaller vacuum chamber. This smaller horizontal cylindrical vacuum chamber has been outfitted with a helium-cooled liner that can be connected to the facility's helium refrigeration system bringing the existing kilowatt of refrigeration capacity to bear on a 1 meter diameter x 2 meter long test envelope. Cryogenic environments to less than 20 Kelvin are now possible in only a few hours. SOMTC's existing instruments (the Instantaneous Phase-shifting Interferometer (IPI) from ADE Phase-Shift Technologies and the PhaseCam from 4D Vision Technologies) view the optic under test through a 150 mm clear aperture BK-7 window. Since activation and chamber characterization tests in September 2001, the new chamber has been used to perform a cryogenic (less than 30 Kelvin) optical test of a 22.5 cm diameter x 127 cm radius of curvature Si02 mirror, a cryogenic survival (less than 30 Kelvin) test of an adhesive, and a cryogenic cycle (less than 20 Kelvin) test of a ULE mirror. A vibration survey has also been performed on the test chamber. Chamber specifications and performance data, vibration environment data, and limited test results will be presented.

Kegley, Jeff↗

Underwater Laser Cutting Technology - 16491

Underwater dismantling is advantageous for the highly radioactive apparatuses such as nuclear reactor internals. The most advantageous point of underwater dismantling is a radiation exposure reduction for workers. Underwater dismantling can take advantage of the water shielding. Then it can make the exposure reduction for workers and contamination reduction for work area be realized. And, underwater laser cutting technology has major three advantages. First advantage is lower action force. Therefore it can be possible that we can use a simple remote device for underwater dismantling operation. Second advantage is to reduce secondary waste. The cutting kerf size of underwater laser cutting is very narrow, so the amount of cutting dross is very small. Third advantage is very simple methods for dismantling. This advantage can reduce process time for cutting. On the other hand, the contaminated off-gas which generates during cutting should be taken care. IHl Corporation (IHI) developed the underwater laser cutting devices. The characteristic of IHI's laser cutting torch is that there is no air habitat. Therefore, the positions of the torch and the access to the narrow space have little limitation. Using the device the series of performance tests were performed in order to verify the ability of it. In the first Laboratory test at 0.2 meter depth of water, we evaluated the optimum cutting parameters. The next underwater demonstration test at 6 meters depth of water was performed. In the test the cutting performance, which the mild steel plate of the thickness of 12 mm can be cut at the speed of 300 mm/min with the horizontal and downward position of torch was verified. Then the hot bubble test using real radioactive test coupons was performed to evaluate the radioactivity carried as air borne and the decontamination factor (DF) of off-gas passing through water. This document provides an overview of the underwater laser cutting device that has been developed by IHI, and the advantage of these devices for the dismantling work of underwater apparatus. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of test techniques used in the NASA Langley 0.3-meter Transonic Cryogenic Tunnel

This paper describes test techniques used to obtain data in the 0.3-m Transonic Cryogenic Tunnel. Main sections include steady aerodynamic testing, unsteady aerodynamics, non-intrusive measurements, tunnel performance, and fluid mechanics. Test techniques with adequate previous documentation are briefly presented and referenced, and those for which no documentation yet exists are more thoroughly discussed. Attention is given to the model building and instrumentation technology necessary for testing at high Reynolds numbers in the presence of free transition. It is concluded that the testing techniques thus far demonstrated in the 0.3-m TCT are on par with modern transonic tunnels, and that the specialized techniques needed to exploit the advantages of cryogenic operation can be realized.

Lawing, P. L.↗

Structural Design Considerations for an 8-m Space Telescope

NASA's upcoming ARES V launch vehicle, with its' immerse payload capacities (both volume and mass) has opened the possibilities for a whole new paradigm of space observatories. It becomes practical to consider a monolith mirror of sufficient size to permit significant scientific advantages, both in collection area and smoothness or figure at a reasonable price. The technologies and engineering to manufacture and test 8 meter class monoliths is mature, with nearly a dozen of such mirrors already in operation around the world. This paper will discuss the design requirements to adapt an 8m meniscus mirror into a Space Telescope System, both launch and operational considerations are included. With objects this massive and structurally sensitive, the mirror design must include all stages of the process. Based upon the experiences of the Hubble Space Telescope, testing and verification at both component and integrated system levels are considered vital to mission success. To this end, two different component level test methods for gravity sag (the so call zero- gravity simulation or test mount) are proposed, with one of these methods suitable for the full up system level testing as well.

Arnold, William R. Sr.↗

A Subsurface Explorer for Deep Underground Exploration on Mars

A subsurface explorer (SSX) is being developed at the Jet Propulsion Laboratory which is suitable for exploration of the deep underground environments on Mars. The device is a self-contained piledriver which uses a novel 'spinning hammer' technology to convert a small continuous power feed from the surface over a two-wire tether into a large rotational energy of a spinning mass. The rotational energy is converted to translational energy by a novel mechanism described here. The hammer blows propagate as shock waves through a nosepiece, pulverizing the medium ahead of the SSX. A small portion of the pulverized medium is returned to the surface through a hole liner extending behind the SSX. This tube is 'cast in place' from two chemical feedstocks which come down from the surface through passages in the hole liner and which are reacted together to produce new material with which to produce the hole liner. The lined hole does not need to be the full diameter of the SSX: approximately 100 kilograms of liner material can create a tunnel liner with a three millimeter inside diameter and a six millimeter outside diameter with at total length of four kilometers. Thus it is expected that core samples representing an overlapping set of three-millimeter diameter cores extending the entire length of the SSX traverse could be returned to the surface. A pneumatic prototype has been built which penetrated easily to the bottom of an eight meter vertical test facility. An electric prototype is now under construction. It is expected that the SSX will be able to penetrate through sand or mixed regolith, ice, permafrost, or solid rock, such as basalt. For pure or nearly pure ice applications, the device may be augmented with hot water jets to melt the ice and stir any sediment which may build up ahead of the vehicle. It is expected that an SSX approximately one meter long, three to four centimeters in diameter, and with a power budget of approximately 200 Watts will be able to explore up to approximately five kilometers deep at the rate of about ten meters per day.

Wilcox, B. H.↗

Experimental Study of Counterflow Cooling Using a Test Loop to Simulate the Thermal Characteristics of a HTS Cable System

The counterflow cooling configuration is a compact, efficient, and relatively low cost thermal management approach for long-length HTS cable systems. In the counter-flow cooling configuration the coolant flow, typically liquid nitrogen, is initially supplied through the center of the cable turning around at the far end of the cable and returning through the annular space between the cable and the inner cryostat wall, using a single cryostat. The temperature distributions along the cable and the nitrogen flow streams are extremely difficult to measure in an operating HTS cable because of the issues associated with installing thermometers on high voltage components. A 5-meter long test loop has been built that simulates a counter-flow cooled, HTS cable using a heated metal tube to simulate the cable. The test loop contains calibrated thermometers to measure the temperature distribution along the tube and the return liquid nitrogen stream. Measured temperature distributions in the return flow stream and along the tube wall for varying flow rates and heating conditions to simulate a HTS cable are presented and discussed.

Demko, Jonathan A↗

Support of gas flowmeter upgrade

A project history review, literature review, and vendor search were conducted to identify a flowmeter that would improve the accuracy of gaseous flow measurements in the White Sands Test Facility (WSTF) Calibration Laboratory and the Hydrogen High Flow Facility. Both facilities currently use sonic flow nozzles to measure flowrates. The flow nozzle pressure drops combined with corresponding pressure and temperature measurements have been estimated to produce uncertainties in flowrate measurements of 2 to 5 percent. This study investigated the state of flowmeter technology to make recommendations that would reduce those uncertainties. Most flowmeters measure velocity and volume, therefore mass flow measurement must be calculated based on additional pressures and temperature measurement which contribute to the error. The two exceptions are thermal dispersion meters and Coriolis mass flowmeters. The thermal dispersion meters are accurate to 1 to 5 percent. The Coriolis meters are significantly more accurate, at least for liquids. For gases, there is evidence they may be accurate to within 0.5 percent or better of the flowrate, but there may be limitations due to inappropriate velocity, pressure, Mach number and vibration disturbances. In this report, a comparison of flowmeters is presented. Candidate Coriolis meters and a methodology to qualify the meter with tests both at WSTF and Southwest Research Institute are recommended and outlined.

Waugaman, Dennis↗

Low flow vortex shedding flowmeter

The purpose was to continue a development project on a no moving parts vortex shedding flowmeter used for flow measurement of hypergols. The project involved the design and construction of a test loop to evaluate the meter for flow of Freon which simulates the hypergol fluids. Results were obtained on the output frequency characteristics of the flow meter as a function of flow rate. A family of flow meters for larger size lines and ranges of flow was sized based on the results of the tested meter.

Waugaman, Charles J.↗

Design and Build of Reactor Simulator for Fission Surface Power Technology Demonstrator Unit

The Nuclear Systems Team at NASA Marshall Space Flight Center (MSFC) focuses on technology development for state of the art capability in non-nuclear testing of nuclear system and Space Nuclear Power for fission reactor systems for lunar and Mars surface power generation as well as radioisotope power systems for both spacecraft and surface applications. Currently being designed and developed is a reactor simulator (RxSim) for incorporation into the Technology Demonstrator Unit (TDU) for the Fission Surface Power System (FSPS) Program, which is supported by multiple national laboratories and NASA centers. The ultimate purpose of the RxSim is to provide heated NaK to a pair of Stirling engines in the TDU. The RxSim includes many different systems, components, and instrumentation that have been developed at MSFC while working with pumped NaK systems and in partnership with the national laboratories and NASA centers. The main components of the RxSim are a core, a pump, a heat exchanger (to mimic the thermal load of the Stirling engines), and a flow meter for tests at MSFC. When tested at NASA Glenn Research Center (GRC) the heat exchanger will be replaced with a Stirling power conversion engine. Additional components include storage reservoirs, expansion volumes, overflow catch tanks, safety and support hardware, instrumentation (temperature, pressure, flow) for data collection, and power supplies. This paper will discuss the design and current build status of the RxSim for delivery to GRC in early 2012.

Godfroy, Thomas↗

Flight test experience using advanced airborne equipment in a time-based metered traffic environment

A series of test flights have demonstrated that time-based metering guidance and control was acceptable to pilots and air traffic controllers. The descent algorithm of the technique, with good representation of aircraft performance and wind modeling, yielded arrival time accuracy within 12 sec. It is expected that this will represent significant fuel savings (1) through a reduction of the time error dispersions at the metering fix for the entire fleet, and (2) for individual aircraft as well, through the presentation of guidance for a fuel-efficient descent. Air traffic controller workloads were also reduced, in keeping with the reduction of required communications resulting from the transfer of navigation responsibilities to pilots. A second series of test flights demonstrated that an existing flight management system could be modified to operate in the new mode.

Morello, S. A.↗

Characterizing Photometric Flicker

The focus of this study is simply to report on the commercial availability and performance of emerging flicker meters. Commercial-meter measurements and calculations were compared against those generated by a photoelectric characterization system developed by the Pacific Northwest National Laboratory (PNNL). The results and analysis show that the three commercially available flicker meters evaluated for this study measured light-intensity waveforms and calculated essential flicker-performance characteristics and metrics similarly, both to each other and to the reference meter chosen as an accuracy benchmark. Some differences in performance were found, however, when measurements were taken of light-intensity waveforms with significant high-frequency content – greater than the dominant 120 Hz found in many products at full output. Such conditions may be found in light sources that employ pulse-width modulation to achieve their target light output (e.g., intensity or color). If the meter was not appropriately configured (e.g., sampling frequency was too low), or if proper configuration was not possible given meter constraints (e.g., maximum number of available data points), then the waveform characteristics were not accurately captured, often resulting in the calculation of flicker metrics that deviated significantly from the reference.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geophysical Imaging of Flow and Transport (GIFT): FY24 Status Report

The GIFT (Geophysical Imaging of Flow and Transport) system will improve predictive capabilities as a platform for collecting multi-physical (MP) time-lapse datasets from well-controlled laboratory experiments. This will enable more accurate prediction of multi-phase fluid flow during delivery and transport of insitu remedial amendments as important components of the overall Hanford Site cleanup mission. Design and construction of the GIFT system, which consists of a meter-scale test cell and a network of custom gas circulation and analysis systems, was accomplished in fiscal year (FY) 2024, with plans to add liquid circulation to the system and use this new capability for multi-phase deep vadose experiments starting in FY25.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-Vacuum Condenser Design: Experimental Effects from Cesium and Mercury Ion Beams

Effects of variable-energy electrostatic rocket-engine ion exhaust beams that pertain to the design of high-vacuum condensers are discussed. Three ion-engine beam sources, using cesium and mercury as propellants, were operated at energy levels of 200 to 9000 electron volts and currents of 0.002 to 0.200 ampere. Five condenser geometries, having surface areas from 0.287 to 5.76 square meters, were tested. Values for a function of the accommodation and condensation coefficients, which appears in an existing theoretical analysis, were determined. Although exhibiting rather wide variations in some tests, the values were estimated at approximately 0.15 for cesium and 0.015 for mercury. A method of estimating condenser surface area requirements is given.

MERCURY /METAL/↗

Optical monitor panel Patent

Optical monitor panel consisting of translucent screen with test or meter information projected onto it from rear for application in control rooms of missile launching and tracking stations

Griffin, F. D.↗