Search NASA⌕ Search

SEARCH · Search NASA

Results for “missing data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Gaseous Ammonia Measurements at the S2 site for the CoURAGE campaign

This dataset contains measurements of gaseous ammonia (NH3(g)) at the S2 (Mt. Airy) site during the CoURAGE study from April to June 2025. This dataset includes 10-minute and 30-minute average NH3(g) concentrations in units of micrograms per cubic meter. Measurements are conducted with an AiRRmonia NH3 analyzer manufactured by RR Mechatronics. A data flag of -999 indicates missing data due to the instrument being offline (maintenance, calibration, etc.) while a data flag of -888 indicates measurements below the instrument LOD (LOD = 0.1 micrograms per cubic meter). The uncertainty of the measurements is 15%.

AiRRmonia NH3 analyzer↗

Worst case earth charging environment

The Applications Technology Satellite-6 (ATS-6) geosynchronous satellite charged up to -2200 V in sunlight on day 178, 1974. This event, being the highest known spacecraft charging event in sunlight, is used to estimate a worst case geosynchronous plasma environment for predicting the spacecraft potential in eclipse. The advantage of using this sunlight spectrum as opposed to an eclipse case is that the ion and electron fluxes to the detectors are shifted only slightly due to the spacecraft potential. After correcting the available data for satellite potential and missing data above 81 KeV, it is found that the plasma can be characterized by a single Maxwellian approximation having an electron density of 1.22/cu cm, electron temperature of 16 KeV, hydrogen ion density of 0.24/cu cm, and hydrogen ion temperature of 29 KeV. In eclipse the spacecraft would have charged up to -28 kV, the highest estimated potential to date in the earth's plasma environment.

Deutsch, M.-J. C.↗

Bond Dissociation Energies of the Tungsten Fluorides and Their Singly-Charged Ions: A Density Functional Survey

The dissociation of WF6 and the related singly-charged cations and anions into the lower fluorides and fluorine atoms has been investigated theoretically using density functional theory (B3LYP) and relativistic effective core potentials, with estimates of spin-orbit effects included using a simple model. The inclusion of spin-orbit is essential for a correct description of the thermochemistry. The total atomization energy of the neutral and anionic WF6 is reproduced to within 25 kcal/mol, but comparison of individual bond dissociation energies with available experimental data shows discrepancies of up to 10 kcal/mol. The results are nevertheless useful to help resolve discrepancies in experimental data and provide estimates of missing data.

Dyall, Kenneth G.↗

Visual Data Analysis for Satellites

The Visual Data Analysis Package is a collection of programs and scripts that facilitate visual analysis of data available from NASA and NOAA satellites, as well as dropsonde, buoy, and conventional in-situ observations. The package features utilities for data extraction, data quality control, statistical analysis, and data visualization. The Hierarchical Data Format (HDF) satellite data extraction routines from NASA's Jet Propulsion Laboratory were customized for specific spatial coverage and file input/output. Statistical analysis includes the calculation of the relative error, the absolute error, and the root mean square error. Other capabilities include curve fitting through the data points to fill in missing data points between satellite passes or where clouds obscure satellite data. For data visualization, the software provides customizable Generic Mapping Tool (GMT) scripts to generate difference maps, scatter plots, line plots, vector plots, histograms, timeseries, and color fill images.

Lau, Yee↗

Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) Winter Intensive Operational Period: Aerodynamic Particle Sizer Field Campaign Report

An aerodynamic particle sizer spectrometer (APS, model 3321 by TSI Inc., Shoreview, Minnesota) was deployed at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Eastern North Atlantic (ENA) observatory during the second (winter) intensive operational period (IOP) of the Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) field campaign. Data were collected from January 9 through February 26, 2018, covering the second deployment of the ARM Aerial Facility (AAF) aircraft within ACE-ENA. The standard ENA instrument suite does not provide measurements of aerosol particle size distribution for diameters greater than one micron. Properties of coarse-mode (super-micron) aerosols are rarely measured, although super-micron particles can play an important role in the aerosol life cycle, affecting aerosol optical properties and cloud nuclei activity (e.g., Clarke et al. 2003). The APS was deployed to fill this gap in particle size measurements: it is capable of measuring size-resolved concentration of the aerosols in the 0.5-20 μm range (aerodynamic diameter). The APS was installed in the aerosol trailer to sample through the main stack. Special attention was given to selection of the instrument location (just below the main stack) to minimize particle losses in the connecting lines. Most atmospheric aerosols are hygroscopic, so the measurement of the aerosol size distributions should either be performed in a controlled humidity environment or accompanied by concurrent measurement of the temperature and humidity of the sample air. The latter strategy was used during this deployment: a high-precision humidity/temperature transmitter (model EE08 by E+E Elektonik GMBH, Engerwitzdorf, Germany) was mounted in the APS sampling line immediately upstream of the APS inlet. A dedicated laptop computer was used for data collection and communications. The APS was controlled with vendor-supplied software (Aerosol Instrument Manager, ver. 10.1, TSI); aerosol size distribution data were collected over a period of 55 seconds and converted to one-minute averages. Temperature and humidity analog signals were acquired via analog-to-digital converter (ADC) module (model WTAIN-M by Weeder Technologies, Fort Walton Beach, Florida) using vendor-supplied software (ModCom) with 1- sec resolution. In post-processing, the APS data were exported from TSI proprietary format into “comma-separated value” American Standard Code for Information Interchange (ASCII) files and matched with appropriately averaged temperature and humidity data. Two significant periods of missing data were caused by local power outages. Vendor-supplied software was not designed for unattended operation: it needs to be manually restarted including sensor configuration setup.

ACE-ENA, Azores, ultra-high-sensitivity aerosol sp↗

SU-E-T-524: Web-Based Radiation Oncology Incident Reporting and Learning System (ROIRLS)

Purpose: Describe a Web-based Radiation Oncology Incident Reporting and Learning system that has the potential to improve quality of care for radiation therapy patients. This system is an important facet of continuing effort by our community to maintain and improve safety of radiotherapy.Material and Methods: The VA National Radiation Oncology Program office has embarked on a program to electronically collect adverse events and near miss data of radiation treatment of over 25,000 veterans treated with radiotherapy annually. Software used for this program is deployed on the VAs intranet as a Website. All data entry forms (adverse event or near miss reports, work product reports) utilize standard causal, RT process step taxonomies and data dictionaries defined in AAPM and ASTRO reports on error reporting (AAPM Work Group Report on Prevention of Errors and ASTROs safety is no accident report). All reported incidents are investigated by the radiation oncology domain experts. This system encompasses the entire feedback loop of reporting an incident, analyzing it for salient details, and developing interventions to prevent it from happening again. The operational workflow is similar to that of the Aviation Safety Reporting System. This system is also synergistic with ROSIS and SAFRON. Results: The ROIRLS facilitates the collection of data that help in tracking adverse events and near misses and develop new interventions to prevent such incidents. The ROIRLS electronic infrastructure is fully integrated with each registered facility profile data thus minimizing key strokes and multiple entries by the event reporters. Conclusions: OIRLS is expected to improve the quality and safety of a broad spectrum of radiation therapy patients treated in the VA and fulfills our goal of Effecting Quality While Treating Safely The Radiation Oncology Incident Reporting and Learning System software used for this program has been developed, conceptualized and maintained by TSG Innovations Inc. and is deployed on the VA intranet as a Website. The Radiation Oncology Incident Reporting and Learning System software used for this program has been developed, conceptualized and maintained by TSG Innovations Inc. and is deployed on the VA intranet as a Website.

60 APPLIED LIFE SCIENCES↗

SU-E-T-469: Implementation of VAs Web-Based Radiotherapy Incident Reporting and Analysis System (RIRAS)

Purpose: This Web-based Radiotherapy Incident Reporting and Analysis System (RIRAS) is a tool to improve quality of care for radiation therapy patients. This system is an important facet of continuing effort by our community to maintain and improve safety of radiotherapy.Material and Methods: VA’s National Radiation Oncology Program office has embarked on a program to electronically collect adverse events and good-catch data of radiation treatment of over 25,000 veterans treated with radiotherapy annually. This VA-Intranet based software design has made use of dataset taxonomies and data dictionaries defined in AAPM/ASTRO reports on error reporting. We used proven industrial and medical event reporting techniques to avoid several common problems faced in effective data collection such as incomplete data due to data entry fatigue by the reporters, missing data due to data difficult to obtain or not familiar to most reporters, missing reports due to fear of reprisal etc. This system encompasses the entire feedback loop of reporting an incident, analyzing it for salient details, and developing interventions to prevent it from happening again. The analysis reports with corrective, learning actions are shared with the reporter/facility and made public to the community (after deidentification) as part of the learning process. Results: Till date 50 incident/good catches have been reported in RIRAS and we have completed analysis on 100% of these reports. This is done due to the fact that each reported incidents is investigated and a complete analysis/patient-safety-work-product report is generated by radiation oncology domain-experts. Conclusions Because of the completeness of the data, the system has enabled us to analyze process steps and track trends of major errors which in the future will lead to implementing system wide process improvement steps and safe standard operating procedures for each radiotherapy treatment modality/technique and fulfills our goal of “Effecting Quality While Treating Safely”. RIRAS developed and copyrighted by TSG Innovations Inc.

60 APPLIED LIFE SCIENCES↗

Generalized Canonical Polyadic Tensor Decomposition

Tensor decomposition is a fundamental unsupervised machine learning method in data science, with applications including network analysis and sensor data processing. This work develops a generalized canonical polyadic (GCP) low-rank tensor decomposition that allows other loss functions besides squared error. For instance, we can use logistic loss or Kullback--Leibler divergence, enabling tensor decomposition for binary or count data. We present a variety of statistically motivated loss functions for various scenarios. We provide a generalized framework for computing gradients and handling missing data that enables the use of standard optimization methods for fitting the model. Furthermore, we demonstrate the flexibility of the GCP decomposition on several real-world examples including interactions in a social network, neural activity in a mouse, and monthly rainfall measurements in India.

97 MATHEMATICS AND COMPUTING↗

How robust are estimates of key parameters in standard viral dynamic models?

Mathematical models of viral infection have been developed, fitted to data, and provide insight into disease pathogenesis for multiple agents that cause chronic infection, including HIV, hepatitis C, and B virus. However, for agents that cause acute infections or during the acute stage of agents that cause chronic infections, viral load data are often collected after symptoms develop, usually around or after the peak viral load. Consequently, we frequently lack data in the initial phase of viral growth, i.e., when pre-symptomatic transmission events occur. Missing data may make estimating the time of infection, the infectious period, and parameters in viral dynamic models, such as the cell infection rate, difficult. However, having extra information, such as the average time to peak viral load, may improve the robustness of the estimation. Here, we evaluated the robustness of estimates of key model parameters when viral load data prior to the viral load peak is missing, when we know the values of some parameters and/or the time from infection to peak viral load. Although estimates of the time of infection are sensitive to the quality and amount of available data, particularly pre-peak, other parameters important in understanding disease pathogenesis, such as the loss rate of infected cells, are less sensitive. Viral infectivity and the viral production rate are key parameters affecting the robustness of data fits. Fixing their values to literature values can help estimate the remaining model parameters when pre-peak data is missing or limited. We find a lack of data in the pre-peak growth phase underestimates the time to peak viral load by several days, leading to a shorter predicted growth phase. On the other hand, knowing the time of infection (e.g., from epidemiological data) and fixing it results in good estimates of dynamical parameters even in the absence of early data. While we provide ways to approximate model parameters in the absence of early viral load data, our results also suggest that these data, when available, are needed to estimate model parameters more precisely.

59 BASIC BIOLOGICAL SCIENCES↗

OmicsMLMentor: A Web Application for Guided Machine Learning Analysis of Omics Data

Expression-based omics technologies (e.g. proteomics, metabolomics, transcriptomics, etc.) increasingly rely on supervised and unsupervised machine learning (ML) models to find key biomolecules distinguishing conditions, identify natural groupings in biological data, or generate predictions for outcomes of interest. Fitting ML models to omics data presents several challenges, including handling missing data, selecting a normalization method, choosing a valid model, and optimizing hyperparameters, all requiring statistical programming skills to address these challenges. Thus, the open-source web application SLOPE was designed to lower the barrier to ML modeling for omics data. SLOPE supports the fitting of 15 ML models (10 supervised and 5 unsupervised) tailored to omics datasets, such as proteomics, metabolomics, lipidomics, and transcriptomics. SLOPE offers several omics-specific features, including methods for handling missingness (imputation, conversion, removal), normalization tests, ranking of models based on the structure of a user’s data and user input, and optimal hyperparameter selections using cross-validation splits. By streamlining ML workflows for omics analysis, SLOPE address critical gaps in existing online web tools, facilitating a broader adoption of these models for omics research. Here, SLOPE is applied to data from a lignin exposure study to highlight the workflow for fitting both supervised and unsupervised models to data.

lipidomics↗

Cleaning Images with Gaussian Process Regression

Many approaches to astronomical data reduction and analysis cannot tolerate missing data: corrupted pixels must first have their values imputed. This paper presents astrofix, a robust and flexible image imputation algorithm based on Gaussian process regression. Through an optimization process, astrofix chooses and applies a different interpolation kernel to each image, using a training set extracted automatically from that image. It naturally handles clusters of bad pixels and image edges and adapts to various instruments and image types. For bright pixels, the mean absolute error of astrofix is several times smaller than that of median replacement and interpolation by a Gaussian kernel. We demonstrate good performance on both imaging and spectroscopic data, including the SBIG 6303 0.4 m telescope and the FLOYDS spectrograph of Las Cumbres Observatory and the CHARIS integral-field spectrograph on the Subaru Telescope.

42 ENGINEERING↗

A Kriging based spatiotemporal approach for traffic volume data imputation

Along with the rapid development of Intelligent Transportation Systems, traffic data collection technologies have progressed fast. The emergence of innovative data collection technologies such as remote traffic microwave sensor, Bluetooth sensor, GPS-based floating car method, and automated license plate recognition, has significantly increased the variety and volume of traffic data. Despite the development of these technologies, the missing data issue is still a problem that poses great challenge for data based applications such as traffic forecasting, real-time incident detection, dynamic route guidance, and massive evacuation optimization. A thorough literature review suggests most current imputation models either focus on the temporal nature of the traffic data and fail to consider the spatial information of neighboring locations or assume the data follow a certain distribution. These two issues reduce the imputation accuracy and limit the use of the corresponding imputation methods respectively. As a result, this paper presents a Kriging based data imputation approach that is able to fully utilize the spatiotemporal correlation in the traffic data and that does not assume the data follow any distribution. A set of scenarios with different missing rates are used to evaluate the performance of the proposed method. The performance of the proposed method was compared with that of two other widely used methods, historical average and K-nearest neighborhood. Comparison results indicate that the proposed method has the highest imputation accuracy and is more flexible compared to other methods.

Science & Technology - Other Topics↗

Astronaut Preflight Cardiovascular Variables Associated with Vascular Compliance are Highly Correlated with Post-Flight Eye Outcome Measures in the Visual Impairment Intracranial Pressure (VIIP) Syndrome Following Long Duration Spaceflight

The detection of the first VIIP case occurred in 2005, and adequate eye outcome measures were available for 31 (67.4%) of the 46 long duration US crewmembers who had flown on the ISS since its first crewed mission in 2000. Therefore, this analysis is limited to a subgroup (22 males and 9 females). A "cardiovascular profile" for each astronaut was compiled by examining twelve individual parameters; eleven of these were preflight variables: systolic blood pressure, pulse pressure, body mass index, percentage body fat, LDL, HDL, triglycerides, use of anti‐lipid medication, fasting serum glucose, and maximal oxygen uptake in ml/kg. Each of these variables was averaged across three preflight annual physical exams. Astronaut age prior to the long duration mission, and inflight salt intake was also included in the analysis. The group of cardiovascular variables for each crew member was compared with seven VIIP eye outcome variables collected during the immediate post‐flight period: anterior-posterior axial length of the globe measured by ultrasound and optical biometry; optic nerve sheath diameter, optic nerve diameter, and optic nerve to sheath ratio‐ each measured by ultrasound and magnetic resonance imaging (MRI), intraocular pressure (IOP), change in manifest refraction, mean retinal nerve fiber layer (RNFL) on optical coherence tomography (OCT), and RNFL of the inferior and superior retinal quadrants. Since most of the VIIP eye outcome measures were added sequentially beginning in 2005, as knowledge of the syndrome improved, data were unavailable for 22.0% of the outcome measurements. To address the missing data, we employed multivariate multiple imputation techniques with predictive mean matching methods to accumulate 200 separate imputed datasets for analysis. We were able to impute data for the 22.0% of missing VIIP eye outcomes. We then applied Rubin's rules for collapsing the statistical results across our 200 multiply imputed data sets to assess the canonical correlation between the eye outcomes and the twelve astronaut cardiovascular variables available for all 31 subjects. Results: A highly significant canonical correlation was observed among the canonical solutions (p<.00001), with an average best canonical correlation of.97. The results suggest a strong association between astronauts' measures of cardiovascular health and the seven eye outcomes of the VIIP syndrome used in this analysis. Furthermore, the "joint test" revealed a significant difference in cardiovascular profile between male and female astronauts (Prob > F = 0.00001). Overall, female astronauts demonstrated a significantly healthier cardiovascular status. Individually, the female astronauts had significantly healthier profiles on seven of twelve cardiovascular variables than the men (p values ranging from <0.0001 to <0.05). Male astronauts did not demonstrate significantly healthier values on any of the twelve cardiovascular variables measured

Otto, Christian↗

SHELXT – Integrated space-group and crystal-structure determination

SHELXT automates routine small-molecule structure determination starting from single-crystal reflection data, the Laue group and a reasonable guess as to which elements might be present. The new computer program SHELXT employs a novel dual-space algorithm to solve the phase problem for single-crystal reflection data expanded to the space group P1. Missing data are taken into account and the resolution extended if necessary. All space groups in the specified Laue group are tested to find which are consistent with the P1 phases. After applying the resulting origin shifts and space-group symmetry, the solutions are subject to further dual-space recycling followed by a peak search and summation of the electron density around each peak. Elements are assigned to give the best fit to the integrated peak densities and if necessary additional elements are considered. An isotropic refinement is followed for non-centrosymmetric space groups by the calculation of a Flack parameter and, if appropriate, inversion of the structure. The structure is assembled to maximize its connectivity and centred optimally in the unit cell. SHELXT has already solved many thousand structures with a high success rate, and is optimized for multiprocessor computers. It is, however, unsuitable for severely disordered and twinned structures because it is based on the assumption that the structure consists of atoms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Review of the Use of Wearables in Indoor Environmental Quality Studies and an Evaluation of Data Accessibility from a Wearable Device

An understanding of indoor environmental quality (IEQ) and its effects on occupant well-being can inform building system design and operation. The use of wearables in field studies to collect subjective and objective health performance indicators (HPIs) from a large number of occupants could deliver important improvements in IEQ. To facilitate the use of wearables in IEQ studies, there is a need to identify which HPIs should be collected and to evaluate data accessibility from these devices. To address this issue, a literature review of previous IEQ studies was conducted to identify relationships between different IEQ factors and HPIs, with a focus on HPIs that were collected using wearables. A preliminary assessment of data accessibility from a selected wearable device (Fitbit Versa 2) was performed and documented. The review suggested the need to further investigate and collect sleep quality parameters, heart rate, stress response, as well as subjective ratings of comfort using wearables. The data accessibility assessment revealed issues related to missing data points and data resolution from the examined device. A set of recommendations is outlined to inform future studies.

60 APPLIED LIFE SCIENCES↗

AAF_UHSAS-air_CACTI

The UHSAS-air is the bench version of the UHSAS that measures particle size from 0.06 to 1.0 micro-meters. Aerosol passes through a laser beam and the resulting intensity of scattered light is directly correlated to the diameter of the particle passing through the beam. This isntrument has been modified to volumetricaly control the Sheath Flow using an Alicat flow controller. Data is reported at 1.000s and missing data is reported as -9999 Multiple data flags are present in this version. Counts?: The coincident error is deemed minimal until the counts exceed 4000. Counts between 3000 and 4000 are flagged with a caution flag (1). After 4000 counts a bad flag (2) is triggered and the data should not be used. Noise?: Instrument noise detected in 65-75nm size range. 1: Caution slight noise observed. 2: High amount of noise observed data should not be used. Total? Sum of all the flags triggered Max Flag: Max flag triggered by the above QC test CloudFlag: Warns of the presence of a cloud. Clouds can cause shattering on the probe and result in questionable measurements. Data during these periods of thin clouds (1) or heavy clouds (2) should be used with extreme caution.

54 ENVIRONMENTAL SCIENCES↗

Data acquisition and processing history for the Explorer 33 (AIMP-D) satellite

The quality control monitoring system, using accounting and quality control data bases, made it possible to perform an in-depth analysis. Results show that the percentage of useable data files for experimenter analysis was 97.7%; only 0.4% of the data sequences supplied to the experimenter exhibited missing data. The 50 percentile probability delay values (referenced to station record data) indicate that the analog tapes arrived within 11 days, the data were digitized within 4.2 weeks, and the experimenter tapes were delivered in 8.95 weeks or less.

Karras, T. J.↗

An interactive environment for the analysis of large Earth observation and model data sets

We propose to develop an interactive environment for the analysis of large Earth science observation and model data sets. We will use a standard scientific data storage format and a large capacity (greater than 20 GB) optical disk system for data management; develop libraries for coordinate transformation and regridding of data sets; modify the NCSA X Image and X Data Slice software for typical Earth observation data sets by including map transformations and missing data handling; develop analysis tools for common mathematical and statistical operations; integrate the components described above into a system for the analysis and comparison of observations and model results; and distribute software and documentation to the scientific community.

Bowman, Kenneth P.↗