Search NASA⌕ Search

SEARCH · Search NASA

Results for “missing values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

NOMINAL VALUES FOR SELECTED SOLAR AND PLANETARY QUANTITIES: IAU 2015 RESOLUTION B3

In this brief communication we provide the rationale for and the outcome of the International Astronomical Union (IAU) resolution vote at the XXIXth General Assembly in Honolulu, Hawaii, in 2015, on recommended nominal conversion constants for selected solar and planetary properties. The problem addressed by the resolution is a lack of established conversion constants between solar and planetary values and SI units: a missing standard has caused a proliferation of solar values (e.g., solar radius, solar irradiance, solar luminosity, solar effective temperature, and solar mass parameter) in the literature, with cited solar values typically based on best estimates at the time of paper writing. As precision of observations increases, a set of consistent values becomes increasingly important. To address this, an IAU Working Group on Nominal Units for Stellar and Planetary Astronomy formed in 2011, uniting experts from the solar, stellar, planetary, exoplanetary, and fundamental astronomy, as well as from general standards fields to converge on optimal values for nominal conversion constants. The effort resulted in the IAU 2015 Resolution B3, passed at the IAU General Assembly by a large majority. The resolution recommends the use of nominal solar and planetary values, which are by definition exact and are expressed in SI units. These nominal values should be understood as conversion factors only, not as the true solar/planetary properties or current best estimates. Authors and journal editors are urged to join in using the standard values set forth by this resolution in future work and publications to help minimize further confusion.

79 ASTRONOMY AND ASTROPHYSICS↗

Prevention of a wrong-location misadministration through the use of an intradepartmental incident learning system

Purpose: A series of examples are presented in which potential errors in the delivery of radiation therapy were prevented through use of incident learning. These examples underscore the value of reporting near miss incidents. Methods: Using a departmental incident learning system, eight incidents were noted over a two-year period in which fields were treated 'out-of-sequence,' that is, fields from a boost phase were treated, while the patient was still in the initial phase of treatment. As a result, an error-prevention policy was instituted in which radiation treatment fields are 'hidden' within the oncology information system (OIS) when they are not in current use. In this way, fields are only available to be treated in the intended sequence and, importantly, old fields cannot be activated at the linear accelerator control console. Results: No out-of-sequence treatments have been reported in more than two years since the policy change. Furthermore, at least three near-miss incidents were detected and corrected as a result of the policy change. In the first two, the policy operated as intended to directly prevent an error in field scheduling. In the third near-miss, the policy operated 'off target' to prevent a type of error scenario that it was not directly intended to prevent. In this incident, an incorrect digitally reconstructed radiograph (DRR) was scheduled in the OIS for a patient receiving lung cancer treatment. The incorrect DRR had an isocenter which was misplaced by approximately two centimeters. The error was a result of a field from an old plan being scheduled instead of the intended new plan. As a result of the policy described above, the DRR field could not be activated for treatment however and the error was discovered and corrected. Other quality control barriers in place would have been unlikely to have detected this error. Conclusions: In these examples, a policy was adopted based on incident learning, which prevented several errors, at least one of which was potentially severe. These examples underscore the need for a rigorous, systematic incident learning process within each clinic. The experiences reported in this technical note demonstrate the value of near-miss incident reporting to improve patient safety.

60 APPLIED LIFE SCIENCES↗

GRIP: Constraint-based Explanation of Missing Answers for Graph Queries

Abstract: A useful feature in graph query engines is to clarify “Why certain entities (nodes, attribute values or edges) are missing” in query answers. This task is even more challenging when the relevant data is already missing in the underlying data source. Missing data, on the other hand, can be inferred by enforcing data constraints for graphs. We demonstrate GRIP, a system that exploits data constraints to clarify missing answers for graph queries. (1) Constraint-based ex- planation. Given a desired yet missing entity in the query answer, GRIP ensures to generate finite and minimal sequences of data con- strains (an “explanation”) that should be consecutively enforced to ?? to ensure its occurrence for the same query. (2) Answering “why” and“how” questions. Users can query GRIP with both“Why”(“Why” the element is missing) and “How” questions (“How” to refine the graph to include the missing answer). GRIP engine supports run- time generation of explanations by incrementally maintaining a set of bi-directional search trees. (3) Interactive exploration. GRIP provides a user-friendly GUI to support interactive ad visual exploration of explanations, including both automated generation and step-by-step inspection of graph manipulations.

graphs↗

ARM Climate Research Facility Spectral Surface Albedo Value-Added Product (VAP) Report

This document describes the input requirements, output data products, and methodology for the Spectral Surface Albedo (SURFSPECALB) value-added product (VAP). The SURFSPECALB VAP produces a best-estimate near-continuous high spectral resolution albedo data product using measurements from multifilter radiometers (MFRs). The VAP first identifies best estimates for the MFR downwelling and upwelling shortwave irradiance values, and then calculates narrowband spectral albedo from these best-estimate irradiance values. The methodology for finding the best-estimate values is based on a simple process of screening suspect data and backfilling screened and missing data with estimated values when possible. The resulting best-estimate MFR narrowband spectral albedos are used to determine a daily surface type (snow, 100% vegetation, partial vegetation, or 0% vegetation). For non-snow surfaces, a piecewise continuous function is used to estimate a high spectral resolution albedo at 1 min temporal and 10 cm-1 spectral resolution.

54 ENVIRONMENTAL SCIENCES↗

Predicting Missing Regions in Charged Particle Tracks Using a Sparse 3D Convolutional Neural Network

The 2x2 Demonstrator is a prototype of ND-LAr, the liquid argon time-projection chamber of the Deep Underground Neutrino Experiment’s Near Detector complex. Both the 2x2 Demonstrator and ND-LAr are modular detectors that will have pixelated charge readouts and inactive regions wherein there is no sensitivity to charge deposition and light signals that arise from charged particle interactions with liquid argon. In the 2x2, these inactive regions are located in between the active detector modules, which introduces the challenge of inferring what charge signals ought to look like in these regions. This study explores the use of a Sparse 3D Convolutional Neural Network (ConvNet) to infer missing regions in charged particle tracks. Hits corresponding to energy depositions are voxelized into a three-dimensional grid for each track. Voxels that fall into predefined inactive regions are removed to simulate the lack of detector output. The model is trained to infer the topology of the missing track voxels, with the ultimate goal of inferring the missing charge or energy values in these voxels as well. Results indicate that this approach shows promise in prediction of missing track regions with some accuracy.

Utaegbulam, Hilary↗

Imputation for multisource data with comparison and assessment techniques

Missing data are prevalent issue in analyses involving data collection. The problem of missing data is exacerbated for multisource analysis, where data from multiple sensors are combined to arrive at a single conclusion. In this scenario, it is more likely to occur and can lead to discarding a large amount of data collected; however, the information from observed sensors can be leveraged to estimate those values not observed. We propose two methods for imputation of multisource data, both of which take advantage of potential correlation between data from different sensors, through ridge regression and a state-space model. These methods, as well as the common median imputation, are applied to data collected from a variety of sensors monitoring an experimental facility. Performance of imputation methods is compared with the mean absolute deviation; however, rather than using this metric to solely rank themethods,we also propose an approach to identify significant differences. Imputation techniqueswill also be assessed by their ability to produce appropriate confidence intervals, through coverage and length, around the imputed values. Finally, performance of imputed datasets is compared with a marginalized dataset through a weighted k-means clustering. In general, we found that imputation through a dynamic linearmodel tended to be the most accurate and to produce the most precise confidence intervals, and that imputing the missing values and down weighting them with respect to observed values in the analysis led to the most accurate performance.

97 MATHEMATICS AND COMPUTING↗

FLUKA Analysis of Linac Fault Study Dose Rates

The planned Linac Fault Study was conducted on December 5 and 6, 2013 according to the Fault Study Procedure. Beam energy out the end of the Linac was typically 200 MeV, except for the LB-B1 Fault study that used 100 MeV beam out of the 4 th accelerator cavity (ACC4, also called and labeled as 4 th accelerating structure, AS4). The Linac fault study where beam was steered into the 4 th accelerator cavity (upstream) had beam energy of 150 MeV, since the last cavity was not traversed. Table I describes the list of the Beam Loss Fault Studies generated for verification of the Linac tunnel bulk and Linac supplemental shield effectiveness. The beam charge for the loss locations was typically measured at the LB-IT1 integrating current monitor after the ACC4 cavity, between LB-Q1 and LB-Q2. If beam was transported to the dumps a Faraday cup (LB-DU1 or LBDU2) monitor will yield the transported current to the dump, with the difference between LB-IT1 and LB-DU1 yielding the charge lost ahead of the dump. For beam miss-steered or intercepted ahead of the dumps the transport efficiency is zero. For the ACC4 beam loss fault the assumed current was the LB-ITI value before the miss-steering. For most of the faults the LB-ITI current was reading ~13.4 nC and the pulse rate was 1Hz, for 13.4 nC/s beam current.

36 MATERIALS SCIENCE↗

How robust are estimates of key parameters in standard viral dynamic models?

Mathematical models of viral infection have been developed, fitted to data, and provide insight into disease pathogenesis for multiple agents that cause chronic infection, including HIV, hepatitis C, and B virus. However, for agents that cause acute infections or during the acute stage of agents that cause chronic infections, viral load data are often collected after symptoms develop, usually around or after the peak viral load. Consequently, we frequently lack data in the initial phase of viral growth, i.e., when pre-symptomatic transmission events occur. Missing data may make estimating the time of infection, the infectious period, and parameters in viral dynamic models, such as the cell infection rate, difficult. However, having extra information, such as the average time to peak viral load, may improve the robustness of the estimation. Here, we evaluated the robustness of estimates of key model parameters when viral load data prior to the viral load peak is missing, when we know the values of some parameters and/or the time from infection to peak viral load. Although estimates of the time of infection are sensitive to the quality and amount of available data, particularly pre-peak, other parameters important in understanding disease pathogenesis, such as the loss rate of infected cells, are less sensitive. Viral infectivity and the viral production rate are key parameters affecting the robustness of data fits. Fixing their values to literature values can help estimate the remaining model parameters when pre-peak data is missing or limited. We find a lack of data in the pre-peak growth phase underestimates the time to peak viral load by several days, leading to a shorter predicted growth phase. On the other hand, knowing the time of infection (e.g., from epidemiological data) and fixing it results in good estimates of dynamical parameters even in the absence of early data. While we provide ways to approximate model parameters in the absence of early viral load data, our results also suggest that these data, when available, are needed to estimate model parameters more precisely.

59 BASIC BIOLOGICAL SCIENCES↗

Probing the High Momentum Component of the Deuteron at High Q{sup 2}

The {sup 2}H(e,e{sup '}p)n cross section at a momentum transfer of 3.5 (GeV/c){sup 2} was measured over a kinematical range that made it possible to study this reaction for a set of fixed missing momenta as a function of the neutron recoil angle {theta}{sub nq} and to extract missing momentum distributions for fixed values of {theta}{sub nq} up to 0.55 GeV/c. In the region of 35 deg. {<=}{theta}{sub nq}{<=}45 deg. recent calculations, which predict that final-state interactions are small, agree reasonably well with the experimental data. Therefore, these experimental reduced cross sections provide direct access to the high momentum component of the deuteron momentum distribution in exclusive deuteron electrodisintegration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental and computational results on exciton/free-carrier ratio, hot/thermalized carrier diffusion, and linear/nonlinear rate constants affecting scintillator proportionality

Models of nonproportional response in scintillators have highlighted the importance of parameters such as branching ratios, carrier thermalization times, diffusion, kinetic order of quenching, associated rate constants, and radius of the electron track. For example, the fraction ηeh of excitations that are free carriers versus excitons was shown by Payne and coworkers to have strong correlation with the shape of electron energy response curves from Compton-coincidence studies. Rate constants for nonlinear quenching are implicit in almost all models of nonproportionality, and some assumption about track radius must invariably be made if one is to relate linear energy deposition dE/dx to volume-based excitation density n (eh/cm3) in terms of which the rates are defined. Diffusion, affecting time-dependent track radius and thus density of excitations, has been implicated as an important factor in nonlinear light yield. Several groups have recently highlighted diffusion of hot electrons in addition to thermalized carriers and excitons in scintillators. However, experimental determination of many of these parameters in the insulating crystals used as scintillators has seemed difficult. Subpicosecond laser techniques including interband z scan light yield, fluence-dependent decay time, and transient optical absorption are now yielding experimental values for some of the missing rates and ratios needed for modeling scintillator response. First principles calculations and Monte Carlo simulations can fill in additional parameters still unavailable from experiment. As a result, quantitative modeling of scintillator electron energy response from independently determined material parameters is becoming possible on an increasingly firmer data base. This paper describes recent laser experiments, calculations, and numerical modeling of scintillator response.

Williams, Richard↗

A cross-sectional study of the temporal evolution of electricity consumption of six commercial buildings

Current approaches to building efficiency diagnoses include conventional energy audit techniques that can be expensive and time consuming. In contrast, virtual energy audits of readily available 15-minute-interval building electricity consumption are being explored to provide quick, inexpensive, and useful insights into building operation characteristics. A cross sectional analysis of six buildings in two different climate zones provides methods for data cleaning, population-based building comparisons, and relationships (correlations) of weather and electricity consumption. Data cleaning methods have been developed to categorize and appropriately filter or correct anomalous data including outliers, missing data, and erroneous values (resulting in < 0.5% anomalies). The utility of a cross-sectional analysis of a sample set of building's electricity consumption is found through comparisons of baseload, daily consumption variance, and energy use intensity. Correlations of weather and electricity consumption 15-minute interval datasets show important relationships for the heating and cooling seasons using computed correlations of a Time-Specific-Averaged- Ordered Variable (exterior temperature) and corresponding averaged variables (electricity consumption)(TSAOV method). The TSAOV method is unique as it introduces time of day as a third variable while also minimizing randomness in both correlated variables through averaging. This study found that many of the pair-wise linear correlation analyses lacked strong relationships, prompting the development of the new TSAOV method to uncover the causal relationship between electricity and weather. We conclude that a combination of varied HVAC system operations, building thermal mass, plug load use, and building set point temperatures are likely responsible for the poor correlations in the prior studies, while the correlation of time-specific-averaged-ordered temperature and corresponding averaged variables method developed herein adequately accounts for these issues and enables discovery of strong linear pair-wise correlation R values. TSAOV correlations lay the foundation for a new approach to building studies, that mitigates plug load interferences and identifies more accurate insights into weather-energy relationship for all building types. Over all six buildings analyzed the TSAOV method reported very significant average correlations per building of 0.94 to 0.82 in magnitude. Our rigorous statistics-based methods applied to 15- minute-interval electricity data further enables virtual energy audits of buildings to quickly and inexpensively inform energy savings measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatio-Temporal Denoising Graph Autoencoders with Data Augmentation for Missing Photovoltaic Data Imputation

The integration of the global Photovoltaic (PV) market with real time data-loggers has enabled large scale PV data analytical pipelines for power forecasting and long-term reliability assessment of PV fleets. Nevertheless, the performance of PV data analysis heavily depends on the quality of PV timeseries data. This paper proposes a novel Spatio-Temporal Denoising Graph Autoencoder (STD-GAE) framework to impute missing PV Power Data. STDGAE exploits temporal correlation, spatial coherence, and value dependencies from domain knowledge to recover missing data. It is empowered by two modules. (1) To cope with sparse yet various scenarios of missing data, STD-GAE incorporates a domain-knowledge aware data augmentation module that creates plausible variations of missing data patterns. This generalizes STD-GAE to robust imputation over different seasons and environment. (2) STD-GAE nontrivially integrates spatiotemporal graph convolution layers (to recover local missing data by observed “neighboring” PV plants) and denoising autoencoder (to recover corrupted data from augmented counterpart) to improve the accuracy of imputation accuracy at PV fleet level. We have evaluated our proposed model on two realworld PV datasets. Experimental results show that STD-GAE can achieve a gain of 43.14% in imputation accuracy and remains less sensitive to missing rate, different seasons, and missing scenarios, compared with state-of-the-art data imputation methods such as MIDA and LRTC-TNN.

Fan, Yangxin↗

Hot or Not? An Evaluation of Methods for Identifying Hot Moments of Nitrous Oxide Emissions From Soils

Abstract Effectively quantifying hot moments of nitrous oxide (N 2 O) emissions from agricultural soils is critical for managing this potent greenhouse gas. However, we are challenged by a lack of standard approaches for identifying hot moments, including (a) determining thresholds above which emissions are considered hot moments, and (b) considering seasonal variation in the magnitude and frequency distribution of net N 2 O fluxes. We used one year of hourly N 2 O flux measurements from 16 autochambers that varied in flux magnitude and frequency distribution in a conventionally tilled maize field in central Illinois, USA, to compare three approaches to identify hot moment thresholds: standard deviations (SD) above the mean, 1.5x the interquartile range (IQR), and isolation forest (IF) identification of anomalous values. We also compared these approaches on seasonally subdivided data (early, late, and non‐growing seasons) versus the whole year. Our analyses revealed that 1.5x IQR method best identified N 2 O hot moments. In contrast, using 2 or 4 SD both yielded hot moment threshold values too high, and IF yielded threshold values too low, leading to missed N 2 O hot moments or low net N 2 O fluxes mischaracterized as hot moments, respectively. Furthermore, seasonally subdividing the data set not only facilitated identification of smaller hot moments in the late‐ and non‐growing seasons when N 2 O hot moments were generally smaller but it also increased hot moment threshold values in the early growing season when N 2 O hot moments were larger. Consequently, of the methods evaluated here, we recommend using the 1.5x IQR method on whole year data sets to identify N 2 O hot moments.

Stuchiner, Emily R. [Institute for Sustainability,↗

Underestimation of column NO 2 amounts from the OMI satellite compared to diurnally varying ground-based retrievals from multiple PANDORA spectrometer instruments

Retrievals of total column NO 2 (TCNO 2 ) are compared for 14 sites from the Ozone Measuring Instrument (OMI using OMNO2-NASA v3.1) on the AURA satellite and from multiple ground-based PANDORA spectrometer instruments making direct-sun measurements. While OMI accurately provides the daily global distribution of retrieved TCNO 2 , OMI almost always underestimates the local amount of TCNO 2 by 50 % to 100 % in polluted areas, while occasionally the daily OMI value exceeds that measured by PANDORA at very clean sites. Compared to local ground-based or aircraft measurements, OMI cannot resolve spatially variable TCNO 2 pollution within a city or urban areas, which makes it less suitable for air quality assessments related to human health. In addition to systematic underestimates in polluted areas, OMI's selected 13:30 Equator crossing timepolar orbit causes it to miss the frequently much higher values of TCNO 2 that occur before or after the OMI overpass time. Six discussed Northern Hemisphere PANDORA sites have multi-year data records (Busan,Seoul, Washington DC, Waterflow, New Mexico, Boulder, Colorado, and Mauna Loa),and one site in the Southern Hemisphere (Buenos Aires, Argentina). The first four of these sites and Buenos Aires frequently have high TCNO 2 (TCNO 2 > 0.5 DU). Eight additional sites have shorter-term data records in the US and South Korea. One of these is a 1-year data record from a highly polluted site at City College in New York City with pollution levels comparable to Seoul, South Korea. OMI-estimated air mass factor, surface reflectivity, and the OMI 24 km × 13 km FOV (field of view)are three factors that can cause OMI to underestimate TCNO 2 . Because of the local inhomogeneity of NO x emissions, the large OMI FOV is the most likely factor for consistent underestimates when comparing OMI TCNO 2 to retrievals from the small PANDORA effective FOV (measured in m 2 ) calculated from the solar diameter of 0.5°.

47 OTHER INSTRUMENTATION↗

Electric Field Data from the North Slope of Alaska

File contains raw as well as calibrated electric field values (V/m) from two CS110 electric field meters. The file also contains raw 2-m U and V winds at the same site. The sampling rate is 1Hz. All files contain raw electric field data, as well as calibrated values to a one week ground-based calibration setup. During this week, simultaneous upward-facing ground based electric field measurements were taken alongside the two downward facing instruments on the pole (CS110-3 at 2m and CS110-2 at 5m). Slopes and intercepts were calculated and applied to the values influenced by the pole to convert the raw data to calibrated values. These calibrated values are absolute electric field measurements. There are no missing data codes. The missong data is not included in the files, and thus any files with missing data will be shorter than the normal 86,400 values. In July 2023, the CS110-3 was replaced with an identical instrument named CS110-8, and the CS110-2 was replaced with an identical instrument called CS110-9. All the variable names remained consistent and the same.

54 ENVIRONMENTAL SCIENCES↗

Total OH reactivity measurements in ambient air in a southern Rocky Mountain ponderosa pine forest during BEACHON-SRM08 summer campaign

Total OH reactivity was measured during the Bio-hydro-atmosphere interactions of Energy, Aerosols, Carbon, H2O, Organics and Nitrogen-Southern Rocky Mountain 2008 field campaign (BEACHON-SRM08) held at Manitou Experimental Forest (MEF) in Colorado USA during the summer season in August, 2008. The averaged total OH reactivity was 6.8 s-1, smaller than that measured in urban or suburban areas, while sporadically high OH reactivity was also observed during some evenings. The total OH reactivity measurements were accompanied by observations of traces species such as CO, NO, NOy, O3 and SO2 and VOCs. From the calculation of OH reactivity based on the analysis of these trace species, 35.3-46.3% of OH reactivity for VOCs came from biogenic species that are dominated by 2-methyl-3-butene-2-ol (MBO), and monoterpenes. MBO was the most prominent contribution to OH reactivity of any other trace species. A comparison of observed and calculated OH reactivity shows that the calculated OH reactivity is 29.5-34.8% less than the observed value, implying the existence of missing OH sink. One of the candidates of missing OH was thought to be the oxidation products of biogenic species.

Nakashima, Yoshihiro↗

Growth rate of Rayleigh-Taylor turbulent mixing layers with the foliation approach

For years, astrophysicists, plasma fusion, and fluid physicists have puzzled over Rayleigh-Taylor turbulent mixing layers. In particular, strong discrepancies in the growth rates have been observed between experiments and numerical simulations. Although two phenomenological mechanisms (mode-coupling and mode-competition) have brought some insight on these differences, convincing theoretical arguments are missing to explain the observed values. In this paper, we provide an analytical expression of the growth rate compatible with both mechanisms and is valid for a self-similar, low Atwood Rayleigh-Taylor turbulent mixing subjected to a constant or time-varying acceleration. The key step in this work is the presentation of foliated averages and foliated turbulent spectra highlighted in our three-dimensional numerical simulations. We show that the exact value of the Rayleigh-Taylor growth rate not only depends upon the acceleration history but is also bound to the power-law exponent of the foliated spectra at large scales.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutrino Oscillation Parameter Sensitivity in Future Long-Baseline Experiments

The study of neutrino interactions and propagation has produced evidence for physics beyond the standard model and promises to continue to shed light on rare phenomena. Since the discovery of neutrino oscillations in the late 1990s there have been rapid advances in establishing the three flavor paradigm of neutrino oscillations. The 2012 discovery of a large value for the last unmeasured missing angle has opened the way for future experiments to search for charge-parity symmetry violation in the lepton sector. This thesis presents an analysis of the future sensitivity to neutrino oscillations in the three flavor paradigm for the T2K, NO A, LBNE, and T2HK experiments. The theory of the three flavor paradigm is explained and the methods to use these theoretical predictions to design long baseline neutrino experiments are described. The sensitivity to the oscillation parameters for each experiment is presented with a particular focus on the search for CP violation and the measurement of the neutrino mass hierarchy. The variations of these sensitivities with statistical considerations and experimental design optimizations taken into account are explored. The effects of systematic uncertainties in the neutrino flux, interaction, and detection predictions are also considered by incorporating more advanced simulations inputs from the LBNE experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗