Search NASA⌕ Search

SEARCH · Search NASA

Results for “mobile loading unit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

115 records · Page 7

Evaluation of the Radioactive Material Released in the Harborview Research and Training Building and Some Implications for Emergency Response

On 2 May 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a mobile hot cell on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%, was released from the mobile hot cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy’s Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. Furthermore, the implications for emergency response are relevant to data quality and management. A Data Quality Objective guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and archiving of samples.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Milli-Watt Radioisotope Power to Enable Small, Long-Term Robotic “Probe” Space Exploration

Milli-watt Radioisotope Power Systems (RPS) based on Radioisotope Heater Units (RHUs) could be an ideal power source for certain spacecraft that cannot use solar power due to large distances from the sun, or other environmental constraints, and where they enable or significantly enhance the ability of a mission to meet its scientific or operational goals. Various modular, compact RHU-based thermoelectric (TE) generator concepts developed or derived from current NASA Small Business Innovation Research (SBIR) projects satisfying this need have been investigated. These modular, compact and low mass power systems could support small, highly-mobile robotic exploration packages, and could be incorporated into different robotic package concepts, spacecraft or satellites. Current modular RPS design concepts with 40mW, 80mW and 120mW power levels use RHUs and Bi2Te3 TE converters. Skutterudites materials could be used in the future if new higher thermal energy output and higher temperature miniature heat sources were developed, for example, using technologies currently in the General Purpose Heat Source (GPHS) used in higher electric power output RTGs. Small (a.k.a., “mice-like”) robotic packages could effectively utilize these RHU-driven power levels to accommodate crawling, climbing, monitoring, taking measurements, and communicating during long-term planetary missions aimed at gathering environmental and geologic data (i.e., over multiple decades). Waste heat from the cold side of the TE converter could also be directed toward the electronics and / or energy storage (e.g. batteries) to keep them within design temperature ranges. In addition to power generation and electronics / battery heating, the RHU / TE configuration could be designed to survive an external 500°C bake out procedure for critical spacecraft sterilization, environmental certification and planetary protection. Analytical studies have been performed to optimize various design configurations for power, mass, volume and robotic mobility. Specific power (mW/kg) and volumetric specific power (mW/cm3) characteristics of various design configurations will be presented and key conceptual design tradeoffs will be discussed. Hot- and cold-side thermal interfaces required to meet power and mass goals and associated design sensitivities will also be discussed. RHU / TE systems must overcome critical design challenges to survive high-g loadings in some robotic applications and we will examine the mass impacts required to satisfy various dynamic loading environments up to 10,000 g’s. Power can be generated for a minimum of 30 years or more using plutonium-238 dioxide heat sources (given that Pu-238 has an 87.7 year half-life) with some reduction in power as the heat source naturally degrades.

Bahrami, Poyan↗

Layered Atlantic Smoke Interactions with Clouds (LASIC) Field Campaign Report

Southern Africa is the world’s largest emitter of biomass burning aerosols. Their westward transport over the remote southeast Atlantic Ocean co-locates some of the largest atmospheric loadings of absorbing aerosol with the least examined of the Earth’s major subtropical stratocumulus decks. Global aerosol model results highlight that the largest positive top-of-atmosphere (TOA) forcing in the world occurs in the southeast Atlantic, but this region exhibits large differences in magnitude and sign between reputable models, in part because of high variability in the underlying model cloud distributions. Many uncertainties contribute to the highly variable model radiation fields: the aging of the shortwave-absorbing aerosol during transport, how much of the aerosol mixes into the cloudy boundary layer, and how the low clouds adjust to smoke-radiation and smoke-cloud interactions. In addition, the ability of the biomass burning aerosol to absorb shortwave radiation is known to vary seasonally as the fuel type on land changes. LASIC (Layered Atlantic Smoke Interactions with Clouds) is a strategy to improve our understanding of aged carbonaceous aerosol, its seasonal evolution, and the mechanisms by which clouds adjust to the presence of the aerosol. The observational strategy centers on deploying the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility first ARM Mobile Facility (AMF1) cloud, aerosol, and atmospheric profiling instrumentation to Ascension Island, located within the trade-wind shallow cumulus regime (14.50W, 80S) 3000 km offshore of continental Africa. The location is within the latitude zone of the maximum outflow of aerosol, with the deepening boundary layer known to entrain free-tropospheric smoke. The primary activities for LASIC are: 1) to improve current knowledge on aged biomass burning aerosol and its radiative properties as a function of the seasonal cycle; 2) to use surface-based remote sensing to sensitively interrogate the atmosphere for the relative vertical location of aerosol and clouds; 3) to improve our understanding of the cloud adjustments to the presence of shortwave-absorbing aerosol within the vertical column, both through aerosol-radiation and through aerosol-cloud interactions; 4) to aid low cloud parameterization efforts for climate models. The measurements span June 1, 2016-October 31, 2017, encompassing two July-October biomass burning seasons. The August-September, 2016, months include an intensive operational period (IOP) with 8x/daily radiosondes. In 2017, from 16 August through 7 September, the United Kingdom Facility for Airborne Atmospheric Measurements (FAAM) BAe-146 plane was deployed from Ascension, providing complementary data on the atmosphere’s vertical structure as part of the Cloud-Aerosol-Radiation Interactions and Forcing (CLARIFY) project, with similar scientific goals. The National Aeronautics and Space Administration (NASA) Observations of Clouds above Aerosols and their Interactions (ORACLES) aircraft campaign, sharing similar objectives to LASIC, deployed from Namibia in September, 2016, and Sao Tome in August, 2017. The latter included a suitcase flight to Ascension spanning August 18-21. In 2017 a cavity-attenuated phase shift single-scattering albedo (CAPS-SSA) instrument belonging to Aerodyne was brought to Ascension, gathering data primarily for August, towards providing a second, independent measurement of aerosol absorption. Ascension Island is also an Aerosol Robotic Network (AERONET) site.

biomass burning, aerosols, black carbon, boundary-↗

Decommissioning an Active Historical Reactor Facility at the Savannah River Site - 13453

The Savannah River Site (SRS) is an 802 square-kilometer United States Department of Energy (US DOE) nuclear facility located along the Savannah River near Aiken, South Carolina, where Management and Operations are performed by Savannah River Nuclear Solutions (SRNS). In 2004, DOE recognized SRS as structure within the Cold War Historic District of national, state and local significance composed of the first generation of facilities constructed and operated from 1950 through 1989 to produce plutonium and tritium for our nation's defense. DOE agreed to manage the SRS 105-C Reactor Facility as a potentially historic property due to its significance in supporting the U.S. Cold War Mission and for potential for future interpretation. This reactor has five primary areas within it, including a Disassembly Basin (DB) that received irradiated materials from the reactor, cooled them and prepared the components for loading and transport to a Separation Canyon for processing. The 6,317 square meter area was divided into numerous work/storage areas. The walls between the individual basin compartments have narrow vertical openings called 'slots' that permit the transfer of material from one section to another. Data indicated there was over 830 curies of radioactivity associated with the basin sediments and approximately 9.1 M liters of contaminated water, not including a large quantity of activated reactor equipment, scrap metal, and debris on the basin floor. The need for an action was identified in 2010 to reduce risks to personnel in the facility and to eliminate the possible release of contaminants into the environment. The release of DB water could potentially migrate to the aquifer and contaminate groundwater. DOE, its regulators [U. S. Environmental Protection Agency (USEPA)-Region 4 and the South Carolina Department of Health and Environmental Control (SCDHEC)] and the SC Historical Preservation Office (SHPO) agreed/concurred to perform a non-time critical removal action for the In Situ Decommissioning (ISD) of the 105-C Disassembly Basin. ISD consisted of stabilization/isolation of remaining contaminated water, sediment, activated reactor equipment, and scrap metal by filling the DB with underwater non-structural grout to the appropriate (-4.877 meter) grade-level, thence with dry area non-structural grout to the final -10 centimeter level. The roof over the DB was preserved due to its potential historical significance and to prevent the infiltration of precipitation. Forced evaporation was the form of treatment implemented to remove the approximately 9.1 M liters of contaminated basin water. Using specially formulated grouts, irradiated materials and sediment were treated by solidification/isolation thus reducing their mobility, reducing radiation exposure and creating an engineered barrier thereby preventing access to the contaminants. Grouting provided a low permeability barrier to minimize any potential transport of contaminants to the aquifer. Efforts were made to preserve the historical significance of the Reactor in accordance with the National Historic Preservation Act. ISD provides a cost effective means to isolate and contain residual radioactivity from past nuclear operations allowing natural radioactive decay to reduce hazards to manageable levels. This method limits release of radiological contamination to the environment, minimizes radiation exposure to workers, prevents human/animal access to the hazardous substances, and allows for ongoing monitoring of the decommissioned facility. Field construction was initiated in August 2011; evaporator operations commenced January 2012 and ended July 2012 with over 9 M liters of water treated/removed. Over 8,525 cubic meters of grout were placed, completing in August 2012. The project completed with an excellent safety record, on schedule and under budget. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Aerosol Particle Mixing State and Composition at AMF3 (Interim Field Campaign Report)

The campaign is designed to support deployment of aerosol sampling equipment at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s third ARM Mobile Facility (AMF3) to enable both singe-particle and bulk characterization of the aerosol particles at the field site in Bankhead National Forest, northern Alabama. We are proposing to do this work as part of our proposal “Generalizing aerosol mixing state: synthesis from observations and connection to models,” which has the pre-proposal tracking number PRE-0000035878. The full proposal has Dr. Rachel O’Brien as the Principal Investigator (PI) and Dr. Andy Ault and Dr. Nicole Riemer as Co-PIs. We sought to deploy instruments in winter 2025 and summer 2025 to obtain samples in different seasons, but were delayed by AMF3 set-up and availability of students and PIs. We just completed our first deployment this summer (2025) and we are interested in obtaining samples during this upcoming fall and winter to see the seasonal trends in aerosol mixing state at the site. This will provide a comparison of the impact of biogenic emissions on the mixing state and the chemical composition of the aerosol particles. Overall, the proposed study will provide key information regarding the mixing state of aerosol particles at AMF3 with direct ties to impacts of the particles on cloud formation and light scattering/absorption. From our deployment that ended las week we have some visible observations from our samples. We are observing a regular amount of black carbon on stage 6 of our Micro-Orifice Uniform Deposit Impactor (MOUDI) and we have also observed some short, large increases in aerosol loading. We hope to continue observations of these two features to determine the sources/aging for the black carbon and the physical mixing state as well as the sources for the short (a few minutes) increases in the aerosol loading and determine if the source for these is dust or sea salt or another source. We are also interested in comparing the black carbon we see here to samples collected during the agriculture burns in January/February and in comparing the larger particles to bioaerosols in the spring. To obtain these comparisons, we will need to collect more samples in the other seasons. Finally, we have some size-resolved particle collectors that can be deployed at the same time as the tethered balloon launches. We have discussed with Swarup China about trying to get the timing to work in August and we are interested in coordinating again later, if possible. This will give us ground-level and vertical aerosol mixing state sample sets that will be very exciting to analyze.

54 ENVIRONMENTAL SCIENCES↗

Modular Controllable Transformers (MCT)

Large Power Transformers (LPTs) are at the heart of the electricity infrastructure and are critical pieces in today’s grid. Aging assets, long turn-around times, transportation delays and dependence on foreign manufacturing for these components have created conditions for points of failure across the system. Moreover, there is no available dynamic control on these passive sections of the grid. For all the automation embedded on the low voltage side of the low voltage side of the system there is absolutely no flexibility on the high voltage side. Changes in power flow patterns are brought about by altering dispatch patterns for generators which requires a coordinated effort and is often time consuming. Traditional FACTS based approaches such as UPFC or HVDC light involve massive modifications to the existing infrastructure. Recent instances of physical attacks on LPTs and the slow recovery process associated with fixing or replacing these damaged units has created an increased awareness for this issue. LPT designs are highly customized owing to specific field requirements. Long lead times coupled with transportation delays make procuring and installing LPTs a lengthy process. In an attempt to minimize the recovery time following an LPT failure, transformer manufacturers have developed mobile transformer units. These units typically consist of either a single-phase or three-phase transformer mounted on a truck and characterized by compact form factors. By reducing the assembly time and transport time these units offer a fast and temporary solution to LPT failures. Several efforts led by DOE, Edison Electric Company (EEI) and North American Electric Reliability Corporation (NERC) have led to the RecX program. RecX transformers consist of single phase transformers transported on specialized assemblies to enable fast restoration and minimal installation time. NERC and EEI have instituted transformer sharing programs like Spare Equipment Database (SED) as well as Spare Transformer Equipment Database (STEP) which encourage utilities to maintain and share a fleet of LPTs. Mobile transformers are typically limited to less than 100 MVA to enable transportation on a trailer. Also, the efficiency of mobile transformer units and RecX transformers is lower since they are temporary solutions. The ideal replacement solution would be one that could utilize a set of standardized transformers while incorporating flexibility to influence metrics like power flow, apparent impedance and voltage profiles. In view of these issues the team at Georgia Tech proposed a concept called Modular Controllable Transformers (MCTs). This project was commissioned as a part of DOE’s Transformer Resiliency and Advance Component (TRAC) program. The approach consists of splitting one large unit rated upwards of 100 MVA with smaller modular, standardized units. Each of these smaller units are augmented with a converter to add power flow, voltage and impedance control. Splitting the power level into multiple units has two important implications. By making smaller units, the transportation times can be reduced drastically. Moreover, even though these units have very specific impedance and other parameters, the augmented converters can make it emulate the unit being replaced. Thus, faster replacement times and added controls are achieved making this an extremely resilient approach. In the event of one modular units failure, the other two controllable units can operate in the most resilient fashion keeping the net system overloads to a minimum. Moreover, for the same probability of failure only a fraction of the system capacity is lost. The converter is augmented on to the tertiary winding of the transformer making it retrofittable in the field without massive modifications to the system. The material proposed in this report highlights design considerations to minimize recovery time as well as results displaying overall improvement in resiliency. The cost analysis of this approach shows significant savings compared to UPFC and HVDC lite based approaches. Extensive analysis was conducted on numerous aspects of this project over the course of this project. Simulation studies were conducted to prove the 5MVA converter design. Challenging BIL constraints and transient issues were addressed over the course of this project. Simulations on EMTP platform presented in consequent sections were used to finely tune the control for the same. A final design for a back-to-back 5MVA neutral-point-clamped (NPC) converter was completed in this project. Furthermore, switching components like high power IGBTs from IXYS Westcode Press-Pack series and ABB Stackpack series were identified for this application. These devices exhibit a blocking voltage of 6.5 kV and a nominal collector current of 900 A. Potential housing options as well as existing commercial option were identified for this converter design. A 56 MVA modular transformer unit was designed with Delta Star Inc. with consultation and inputs from all project members. The transformer cooling systems were chosen to be Oil Natural Air Forced (ONAF) to optimize ease of transport. A full Product Requirement Document (PRD) for the converter and the transformer was generated. The team also investigated key aspects of resiliency and how to quantify the same. A metric was developed to analyze resiliency and numerous simulation cases were presented. Increased (N-1) resiliency and outage resistance was showcased through simulation on the Texas Large scale power system. Dynamic control capabilities were also showcased on numerous system level simulations. An IEEE 30 bus system was used to show the ability of the MCT approach to reduce line congestion. Power flow control; a part of the MCTs abilities, showcased a 29% reduction in transformer loading on the same system. Full control over tie line flows was demonstrated on a modified IEEE 13 bus system. Dynamic LTC capabilities were shown through simulation and were compared to traditional LTCs. Furthermore, the ability of the MCTs to alter apparent transformer impedance was simulated to promote standardization of modular transformer units while retaining the ability to emulate a varied range of impedance characteristics. Thus granular control over power flow, voltages, impedances and was presented. Regulatory analysis conducted by Oak Ridge National Laboratory (ORNL) further bolstered the efficacy of the MCT approach and verified the added resiliency achieved due to this approach. As a conclusion, it was proved that the resilience improvement obtained from using the MCT approach is justified by just one failure in a 30-year period. This means that the benefits obtained from using the MCT approach far outweigh the cost of setting this approach up. As a part of the future efforts, the team is proposing building a (12.47-24) kV/400 kVA scaled down unit to control 5MVA of power flows. Emphasis would be laid on using commercial components to speed up the build of these units. Further the actual transport of the modular transformer unit would be a part of this operation and would provide insight into transportation issues. The approach shows much promise and adds key dynamic control on passive sub transmission and transmission sectors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Engineered Barrier System R&D and International Collaborations – LANL (FY20): Spent Fuel and Waste Disposition

The United States Department of Energy’s Spent Fuel and Waste Disposition (SFWD) program is investigating the design and safety function of generic nuclear geologic repositories in a variety of geologic settings (salt, argillite, and crystalline rock). Different configurations and loadings of spent nuclear fuel and waste within disposal canisters are also being investigated, some of which have the potential to generate repository temperatures higher than previously considered (i.e., temperatures >100ºC) by foreign and domestic concepts. This report expands on engineered barrier material stability in a high temperature crystalline rock repository through high temperature hydrothermal experiments. Experiments were designed to develop engineered barrier system (EBS) concepts in a hightemperature crystalline environment in 1) bentonite-Grimsel Granodiorite interactions, 2) bentonite-cement reactions, and 3) interaction between waste canister materials and bentonite. Experiment results are applied to understanding long-term repository performance in terms of radionuclide isolation. One hydrothermal experiment was completed in the rocking autoclaves at LANL in FY-20: IEBS-6 (Grimsel Granodiorite + Wyoming bentonite + cured ordinary Portland cement + Grimsel Granodiorite synthetic groundwater, 250ºC/150 bar, 8 weeks). Several other experiments were planned but were delayed due to the COVID-19 pause in laboratory work. In addition, some characterization of the reaction products of experiments conducted in FY-20 was prevented by COVID-19. Mineral phase chemistry was not measured via electron microprobe analyses for IEBS-6. Quantitative X-ray diffraction results from IEBS-6 and HBT-1 were not completed. The missing analyses and discussion of the results will be included in next year’s report. New characterization that was completed includes scanning electron microscopy of reaction products from IEBS-6, quantitative X-ray diffraction results are presented from IEBS-1 through IBES-5, preliminary scanning electron microscope images and chemical analyses for IEBS-6, X-ray diffraction of the clay fraction from all experiments, measurement/imaging of mineral growth on the surface of steel coupons. Major observations pertaining to bentonite stability in a Grimsel Granodiorite environment include the stability of Na-montmorillonite at 250°C, the formation of trace CSH phases, and the formation of bentonite colloids on experiment cooling. The addition of a cured chip of Portland cement to the bentonite-Grimsel system results in slightly higher pH values and the formation of diverse secondary mineral phases that were not observed in the previous experiments (e.g., analcime, garronite, CSH phases). The new characterization efforts related to the interaction of stainless-steel coupons and bentonite clay focused on thickness and mineralogy of phases that formed at the steel surface. In Wyoming bentonite + Grimsel Granodiorite systems, newly formed minerals at the bentonitesteel coupon interface included alteration of the outermost steel edge to Fe,Cr-oxide phases, followed by Fe-rich phyllosilicates (Fe-saponite, chlorite) and interbedded Fe,Cr,Ni-sulfide phases (pentlandite). Hydrothermal experiments were completed to assess uranium-carbonate complexation at conditions relevant to high-temperature disposal. Autoclave solubility experiments were conducted at 150 to 250ºC with a range of carbonate and uranium concentrations. The experiment results were characterized via situ UV-Visible spectroscopy and synchrotron-based in situ XAS techniques. Results show a significant decrease in the stability of uranyl-carbonate complexes at temperatures above 100ºC along with the precipitation of uranium oxides. Further, at T > 200ºC, results show that uranyl-hydroxyl complexes control solubility of uranium instead of the previously predicted uranyl-carbonate species. These results are significant for understanding the mobility of uranium in the EBS, which will likely contain carbonate-rich fluids. International research efforts focused on three main areas: 1) participation in international conferences, 2) building collaborations with foreign repository programs, and 3) the initiation of an experimental program to complement the full-scale HotBENT test at the Grimsel test site. This experiment included Wyoming bentonite + low carbon steel + Grimsel Granodiorite synthetic groundwater and was run at the planned maximum temperature of the HotBENT test (200°C). Complete characterization of reaction products was hindered by disruptions to laboratory work but will be reported in the next FY. The experimental results obtained in FY-20 continue to document the wide-ranging effects of bulk composition and pressure-temperature conditions in the mineralogical and geochemical evolution of a high-temperature repository environment. Concepts developed will be used to inform models of long-term material stability in a generic crystalline rock-hosted repository.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗