At least 127 records · Page 7

Beneficial Integration of Energy Storage and Load Management with Photovoltaic (PV)

In recent years, a number of industry activities have aimed at addressing the integration challenges posed by the variability and uncertainty of higher penetration of renewable generation sources, like solar photovoltaic (PV) – one of the key objectives of the Sustainable and Holistic Integration of Energy Storage and Solar PV (SHINES) program launched by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE). This EPRI led Beneficial Integration of Energy Storge, and Load Management with PV project aimed to design, develop, and demonstrate end-to-end distributed energy resource (DER) integration solution to build on these activities. EPRI led project team designed and implemented a local controller that uses model predictive control (MPC) algorithm to optimally manage DERs on site by planning for a receding horizon while executing the control settings for the first step of its plan. The team has also developed a system controller to interface with the local controller to demonstrate the hierarchical control and how it can leverage DER capabilities to address challenges like over voltage and thermal limit violations which typically limits the DER hosting capacity of distribution feeders. Team has demonstrated how the local controller with optimization algorithm can effectively manage controllable loads like HVAC, water heater, and pool pumps to allow for greater integration of PV with relatively smaller energy storage system requirements. Optimal utilization of the load control can also reduce the depth of discharge of batteries to meet grid export/import limit from behind-the-meter (BTM) DERs. Proper utilization of DER capabilities via local control intelligence, like the one developed and demonstrated in this project can help the industry to address integration challenges of higher penetration of solar PV in economically efficient manner. This can help to accelerate deployment of clean renewable energy systems at lower societal cost.

14 SOLAR ENERGY↗

The first field application of a low-cost MPC for grid-interactive K-12 schools: Lessons-learned and savings assessment

K-12 schools are the largest energy consumers in the public sector, with their HVAC energy consumption representing the largest portion of their total energy use. While transitioning these schools to grid-interactive HVAC system operation through advanced controls offers significant financial and environmental benefits, and model predictive control (MPC) has been identified as a promising solution to achieve that, very few MPCs are affordable and have been deployed in K-12 schools. This situation raises concerns about the unclear real-world benefits of MPC technology among facility managers and industries. To address this gap, this paper presents a low-cost MPC solution that requires minimal control infrastructure costs and a unique field demonstration at a K-12 school, conducted for both cooling and heating seasons. This work adopted a previously developed MPC and extended it for use in the school application. The MPC aims to coordinate multiple packaged units to eliminate unnecessary peaks and shift cooling or heating loads in response to grid signals based on load conditions, while maintaining thermostat temperatures within school-defined bounds. Throughout the field tests, the MPC achieved a 24% reduction in peak demand during the cooling season and shifted cooling or heating loads by up to 16% in response to the school's utility tariff, considering load conditions, while also allowing end-users to override thermostat setpoints. Further, the paper also discusses the limitations of this study and future research directions for better performance of the MPC at K-12 schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operator learning for energy-efficient building ventilation control with computational fluid dynamics simulation of a real-world classroom

Energy-efficient ventilation control plays an important role in reducing building energy consumption while ensuring occupant health and comfort. While Computational Fluid Dynamics (CFD) simulations provide detailed and physically accurate representations of indoor airflow, their high computational cost limits their use in real-time building control. In this work, we present a neural operator learning framework that combines the physical accuracy of CFD with the computational efficiency of machine learning to enable building ventilation control with the high-fidelity fluid dynamics models. Our method jointly optimizes the airflow supply rates and vent angles to reduce energy use and adhere to air quality constraints. We train an ensemble of neural operator transformer models to learn the mapping from building control actions to airflow fields using high-resolution CFD data. This learned neural operator is then embedded in an optimization-based control framework for building ventilation control. Experimental results show that our approach achieves significant energy savings compared to maximum airflow rate control, rule-based control, as well as data-driven control methods using spatially averaged CO 2 prediction and deep learning–based reduced-order models, while consistently maintaining safe indoor air quality. These results highlight the practicality and scalability of our method in maintaining energy efficiency and indoor air quality in real-world buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupancy-Based Controls for an All-Electric Residential Community in a Cold Climate

In residential buildings, rapid improvements in sensors, communication, and information technology have enabled occupancy-based building controls. These controls utilize occupancy information and modify the operation of the heating, ventilation, and air-conditioning (HVAC) system to minimize excess HVAC energy use, especially when the building is unoccupied. This reduces the total building energy consumption and utility bills while maintaining thermal comfort. In this paper, we present two novel occupancy-driven controls - reactive control and predictive control - and compare their performance. We model an all-electric residential community based on a 27- home community in Basalt, Colorado, in the United States. We simulated various scenarios, considering different temperature setback and control algorithms, to analyze the community-scale impact of these occupancy-based controls. The results show that total HVAC energy savings in a building ranges from 1%- 20% compared to the baseline scenario without occupancy-based controls. The energy-saving potential is highly correlated with the occupancy pattern and temperature setback in the building.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Occupancy-Based Controls for an All-Electric Residential Community in a Cold Climate: Preprint

In residential buildings, rapid improvements in sensors, communication, and information technology have enabled occupancy-based building controls. These controls utilize occupancy information and modify the operation of the heating, ventilation, and air-conditioning (HVAC) system to minimize excess HVAC energy use, especially when the building is unoccupied. This reduces the total building energy consumption and utility bills while maintaining thermal comfort. In this paper, we present two novel occupancy-driven controls - reactive control and predictive control - and compare their performance. We model an all-electric residential community based on a 27- home community in Basalt, Colorado, in the United States. We simulated various scenarios, considering different temperature setback and control algorithms, to analyze the community-scale impact of these occupancy-based controls. The results show that total HVAC energy savings in a building ranges from 1%- 20% compared to the baseline scenario without occupancy-based controls. The energy-saving potential is highly correlated with the occupancy pattern and temperature setback in the building.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Comparative Analysis of ANN and LSTM Prediction Accuracy and Cooling Energy Savings through AHU-DAT Control in an Office Building

This paper proposes the optimal algorithm for controlling the HVAC system in the target building. Previous studies have analyzed pre-selected algorithms without considering the unique data characteristics of the target building, such as location, climate conditions, and HVAC system type. To address this, we compare the accuracy of cooling load prediction using ANN and LSTM algorithms, widely used in building energy research, to determine the optimal algorithm for HVAC control in the target building. We develop a simulation model calibrated with actual data to ensure data reliability and compare the energy consumption of the existing HVAC control method and the two algorithms-based methods. Results show that the ANN algorithm, with a CV(RMSE) of 12.7%, has a higher prediction accuracy than the LSTM algorithm, CV(RMSE) of 17.3%, making it a more suitable algorithm for HVAC control. Furthermore, implementing the ANN-based approach results in a 3.2% cooling energy reduction from the optimal control of Air Handling Unit (AHU) Discharge Air Temperature (DAT) compared to the fixed DAT at 12.8 °C in a representative day. This study demonstrates that ML-based HVAC system control can effectively reduce cooling energy consumption in HVAC systems, providing an effective strategy for energy conservation and improved HVAC system efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Control of an Oscillating Surge Wave Energy Converter

During this project, we experimentally investigated the hydrodynamics and performance of a laboratory-scale oscillating surge wave energy converter (OSWEC).We looked at how flap buoyancy and driveline losses (primarily in the form of stiction) affected the dynamics and performance of the device. In addition, we assessed the influence of flap profile (rounded vs. square edges) on OSWEC hydrodynamics. Through this, we were able to develop a deeper understanding of OSWEC performance and provide guidance on strategies to counteract artifacts that may be present in laboratory models, but are absent in field-scale devices. To do this, we tested a laboratory-scale OSWEC in the Sea Wave Environmental Lab (SWEL) wave tank at the National Renewable Energy Laboratory (NREL). We ran several types of experiments to investigate the hydrodynamics and performance of the device. Overall, we achieved the overall goal of experimentally investigating the hydrodynamics and performance of this device. We discovered important and unexpected trends in performance, and collected time-resolved data to help us further investigate the underlying hydrodynamics responsible for these trends. In addition, we are currently using the time-resolved data from these experiments to build data-driven models of the dynamics, which can in turn be used to inform data-driven model predictive control of this device and address this objective in the future.

16 TIDAL AND WAVE POWER↗

Accurate Prediction of Algal Biomass Lipid, Protein, and Carbohydrate Composition with Machine Learning Regression Modelling of Near-IR Spectra

During large scale algal biomass cultivation, it is difficult to reliably control relative composition to target levels. Rapid determination of chemical composition is feasible by using near infrared (NIR) spectral data. We sought to build and improve on reliable high-throughput screening prediction method based on partial least squares regression (PLSR) by the application of artificial neural networks (ANN) and associated optimization strategies. The algal biomass sample set was designed and created in an iterative process of culturing in physiologically diverse conditions at the GAI field site, followed by compositional analyses at NREL. The workflow allowed us to identify gaps in compositional space for informing the subsequent cultivation and sampling efforts and generated a high quality set of 210 unique samples with chemical analysis results, spectral scanning data, and cultivation metadata. We observed a significant improvement in the performance of carbohydrate content predictions using an optimized ANN model compared to PLSR, with > 16% reduction in mean absolute percent error (MAPE) when tested on the same set of reserved data. The optimized ANN models for FAME and protein prediction performed exceptionally well with 5.99% and 5.09% MAPE, respectively. Application of these methods to detection and quantification of minor biomass constituents that are relevant to certain product streams has shown positive preliminary results, opening the possibility for extensions to the outputs of this powerful data type. All models are accompanied by prediction uncertainties and unsupervised spectral outlier detection to alert an operator to unreliable spectral data. These tools can be deployed for rapid determination of algal culture status, and cultivation and biomass quality improvement.

algal biofuels↗

Zero Voltage Switching AC-DC Converter Based on Zero State Modulation (ZSM)

In this paper, a half-bridge building block that can achieve soft switching across the complete operating range while operating under fixed frequency is proposed. In addition, dead-beat model predictive controls to control the same are also proposed. The proposed converter, referred to as zero-state modulated (ZSM) converter, uses a zero state, enabled by a small auxiliary switch, to achieve soft-switching. The approach allows lower switching loss, controlled dv/dt, small filter inductor, fixed frequency operation allowing interleaving to reduce filter capacitor. A single half-bridge building block can used to realize a ZVS DC-DC converter or multiple of these building blocks can be used to achieve soft switching 1-phase or 3-phase AC-DC converters.

Kandula, Prasad↗

Global-Local Policy Search and its Application in Grid-Interactive Building Control

As the buildings sector represents over 70% of the total U.S. electricity consumption, it offers a great amount of untapped demand-side resources to tackle many critical grid-side problems and improve the overall energy system's efficiency. To help make buildings grid-interactive, this paper proposes a global-local policy search method to train a reinforcement learning (RL) based controller which optimizes building operation during both normal hours and demand response (DR) events. Experiments on a simulated five-zone commercial building demonstrate that by adding a local fine-tuning stage to the evolution strategy policy training process, the control costs can be further reduced by 7.55% in unseen testing scenarios. Baseline comparison also indicates that the learned RL controller outperforms a pragmatic linear model predictive controller (MPC), while not requiring intensive online computation.

demand response↗

Two-Stage Reinforcement Learning Policy Search for Grid-Interactive Building Control

This paper develops an intelligent grid-interactive building controller, which optimizes building operation during both normal hours and demand response (DR) events. To avoid costly on-demand computation and to adapt to non-linear building models, the controller utilizes reinforcement learning (RL) and makes real-time decisions based on a near-optimal control policy. Learning such a policy typically amounts to solving a hard non-convex optimization problem. We propose to address this problem with a novel global-local policy search method. In the first stage, an RL algorithm based on zero-order gradient estimation is leveraged to search for the optimal policy globally, due to its scalability and the potential to escape some poor performing local optima. The obtained policy is then fine-tuned locally to bring the first-stage solution closer to that of the original unsmoothed problem. Experiments on a simulated five-zone commercial building demonstrate the advantages of the proposed method over existing learning approaches. They also show that the learned control policy outperforms a pragmatic linear model predictive controller (MPC) and approaches the performance of an oracle MPC in testing scenarios. Using a state-of-the-art advanced computing system, we demonstrate that the controller can be learned and deployed within hours of training.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

Data-Driven Modeling and Optimization of Building Energy Consumption: a Case Study

Installing sensors and Building Automation Systems (BAS) allows controlling the facility operations while generating data that can be analyzed for model development. This work focuses on data-driven modeling of the building to optimize energy consumption. The City of Orlando aims to reduce its energy consumption so, they provided us access to their BAS for data and studying the operation of its facilities. We selected a mid-size pilot building to conduct data analysis and modeling. We develop an Application Programming Interface (API) to login to the servers and scrape data. The scraped data contains features ranging from environmental conditions to equipment activity. This dataset is a time series so, it's handled in accordance and analyzed to investigate patterns and relations between data points that help choose parameters for predictive models for building and equipment. Finally, the models are optimized to reduce the energy consumption of the facility.

Grover, Divas↗

EASY-SHIFT v Alpha

The software is a generic, price- and load-responsive control algorithm integrating heat pumps with thermal energy storage. The algorithm leverages simple models of the system and easily accessible data to schedule operation of heat pumps and thermal energy storage in ways that minimize the cost of operating the heating/cooling system. This tool is specifically designed to be easy to interact with, and something that industry partners are able to adopt. There are two current state of the art approaches. Industry tends to develop very simple algorithms, with predetermined schedules that are not capable of changing operation in response to changes in operating environment. For example, a control designed to avoid high-price electricity from 5-8 PM will not be able to adapt if the high-price period changes to 4-9 PM. Academia commonly develops algorithms called Model predictive control (MPC). MPC requires extensive data and highly trained staff to develop a specific type of simulation model of the building, connect the building to optimization algorithms, and leverage powerful computers. Industry, with limited time/finance budgets for any project, is resistant to adopting MPC due to the associated high complexity and cost.

Grant, Peter [Lawrence Berkeley National Laborator↗

Phase 1 of the First Solar Small Power System Experiment (experimental System No. 1). Volume 3: Appendix E - N

The design of a solar electric power plant for a small community is reported. Topics covered include: (1) control configurations and interface requirements for the baseline power system; (2) annual small power system output; (3) energy requirements for operation of the collectors and control building; (4) life cycle costs and reliability predictions; (5) thermal conductivities and costs of receiver insulation materials; (6) transient thermal modelling for the baseline receiver/thermal transport system under normal and inclement operating conditions; (7) high temperature use of sodium; (8) shading in a field of parabolic collectors; and (9) buffer storage materials.

Clark, T. B.↗

USAF single-event sonic boom prediction model: PCBoom3

The Air Force has developed PCBoom3, a general-purpose, single-event sonic boom prediction model. The model operates on an IBM PC or compatible, under DOS or Windows. It is accessed via an integrated environment which controls building of input cases, running boom calculations, displaying contours and signatures, and managing all associated data. The primary boom calculation is via a variation of FOBOOM, the focus-boom extension of Thomas's program. Aircraft input is either via a user-provided F-function, or simple N-wave F-functions tabulated for about 20 current aircraft. A fast boom calculation, based on Plotkin's SBORT algorithms, is included for simple N-wave F-functions in a windless atmosphere and flight altitudes up to 60,000 feet. After a run is complete, the user can access an index identifying significant events (focal zones, beginning of footprint, etc.), then plot boom amplitude contours and signatures or spectra at any point in the footprint. The primary uses of this program are expected to be operational planning and boom incident investigation. However, because of the commonality between FOBOOM and the MDBOOM program currently being used for low boom configuration design, this program is of interest to the HSCT community, especially as supersonic route planning activity increases. The Air Force recently conducted a flight test program to evaluate the focal zone capabilities of PCBoom3. Initial results of that program validate the prediction of focal zone geometry, amplitudes, and waveforms.

Plotkin, Kenneth J.↗

Dynamic Analysis of a Building Under Rocket Engine Plume Acoustic Load

Studies have been performed to develop finite-element modeling and simulation techniques to predict the dynamic structural response of Building 4010 to the acoustic load from the plume of high-thrust rocket motors. The building is the Test Control Center and general office space for the E-complex at Stennis Space Center. It is a large single span; light-structured building located approximately 1,000 feet from the E-1 test stand. A three-dimensional shell/beam combined model of the building was built using Pro/Engineer platform and imported into Pro/Mechanica for analysis. An Equivalent Shell technique was developed to simplify the highly complex building structure so that the calculation is more efficient and accurate. A deterministic approach was used for the dynamic analysis. A pre-stressed modal analysis was performed to simulate the weight stiffening of the structure, through which about 200 modes ranging from 0 to 35 Hz were identified. In an initial dynamic frequency analysis, the maximum response over the model was found. Then the complete 3-D distributions of the displacement, as well as the stresses, were calculated through a final frequency analysis. The results were compared to a strain gage and accelerometer recordings from rocket engine tests and showed reasonable agreement.

Qian, Z.↗