Search NASA⌕ Search

SEARCH · Search NASA

Results for “module generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Performance of High Voltage Bipolar Pulse Generator with Fast Push-Pull Solid-State Switch Modules

Four identical pulse generators (pulsers) provide fast beam deflection in the Low Energy Beam Transport (LEBT) beam chopping system at the Spallation Neutron Source (SNS) Linac. The existing pulsers have become obsolete and need to be replaced to improve overall performance of the chopper system. A new bipolar pulse generator has been designed, and a prototype has been built and tested at the SNS. The generator uses fast push-pull transistor BEHLKE switch modules. It can produce a 1MHz burst of alternate 2.5kV with adjustable pulse widths during the 1-ms macro-pulse at a burst repetition frequency of 60Hz with rise/fall times of less than 40ns into a 100pF capacitive load. The performance enhancements of this new pulser in comparison with existing and previous versions of the pulse generator are discussed in the paper. The pulser can be used in applications requiring a series of bipolar ±3.5kV pulses, or unipolar pulses of positive or negative polarity with amplitude up to 4.5kV and various pulse widths with a minimum of 150ns. The maximum switching frequency, number of pulses, or burst repetition frequency in burst mode is limited by maximum power dissipation in the switches and other components. The features of this new pulser along with the results of timing control adjustments, timing and temperature measurements, and HV full power testing on the test stand are presented.

Peplov, Vladimir↗

Interactive Visualization of Multi-Group Cross Sections on High-Fidelity Spatial Meshes

Core simulation tools utilizing Monte Carlo transport methods represent the 'Holy Grail' for nuclear reactor analysis. However, deterministic transport methods pose a number of advantages to Monte Carlo from a computational perspective, which seems likely to make these methods more viable in the near to intermediate term. Deterministic methods almost universally discretize the energy domain in a few to hundreds of energy groups. One of the key challenges for deterministic transport-based methods to be viable is accurate, reactor agnostic multi-group cross section generation. This paper describes tools for data processing and visualization of multigroup cross sections generated on high-fidelity spatial meshes from the OpenMC Monte Carlo code. Next generation deterministic transport reactor core modeling tools will require multi-group cross section (MGXS) generation on high-fidelity spatial meshes. High-fidelity MGXS are necessary for the accurate simulation of neutron physics in nuclear reactors with a high degree of spectral heterogeneity - e.g., large localized neutron flux gradients throughout a reactor core. Although many local (e.g., pin cell) approximations have been developed to model the scalar flux to compute spectral-averaged MGXS, these techniques cannot account for complex intra-pin and intra-assembly spatial self-shielding effects. Monte Carlo presents the most accurate method for reactor agnostic multi-group cross section generation since it does not require the use of local approximations to the flux. Monte Carlo has been proposed as a highly desirable framework for reactor agnostic cross section generation for many years. Monte Carlo methods can effectively embed all of the relevant spectral effects into the MGXS through the random particle tracking and interaction sampling processes. Previous work has applied MCNP and Serpent to compute few-group constants for diffusion calculations, and OpenMC to compute multi-group cross sections for transport-based methods. The primary difficulty with using Monte Carlo for MGXS generation is the tremendous computational resources required to adequately converge multi-group cross sections in each spatial region and energy group. Recent development of the OpenMC Monte Carlo code for high-performance computing platforms has made multigroup cross section generation from Monte Carlo more tractable in the foreseeable future. The recent release of OpenMC v0.7.1 includes a new Python-based module for MGXS generation. The MGXS generation module leverages many of the algorithms and features for 'big data' analysis of large tally datasets on complex spatial meshes. This paper describes the data management workflow and visualization tools which have been developed to explore the plethora of MGXS data generated with OpenMC. It is the authors' hope that the development of the visualization tool described in this paper will ultimately enable the design of machine learning algorithms to accelerate the convergence rate of high-fidelity multi-group cross section generated with Monte Carlo. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PyCCE: A python package for custer correlation expansion simulations of spin qubit dynamics.

PyCCE, an open-source Python library for simulating the dynamics of spin qubits in a spin bath, is presented using the cluster-correlation expansion (CCE) method. PyCCE includes modules to generate realistic spin baths, employing coupling parameters computed from first principles with electronic structure codes, and enables the user to run simulations with either the conventional or generalized CCE method. Three use cases of the Python library are illustrated: the calculation of the Hahn-echo coherence time of the nitrogen-vacancy in diamond; the calculation of the coherence time of the basal divacancy in silicon carbide at avoided crossings; and the calculation for magnetic field orientation-dependent dynamics of a shallow donor in silicon. The complete documentation, downloadable tutorials, and installation instructions are available at https://pycce.readthedocs.io/en/latest/.

coherence↗

Modulating surface acoustic wave generation through superconductivity

Surface acoustic waves (SAWs), with their five orders-of-magnitude slower propagation velocity, allow for considerably shorter wavelengths at the same frequency compared to electromagnetic waves. The short wavelengths allow for device miniaturization and on-chip integration. The generic design of these devices involves piezoelectric substrates with comb-like arrays of Al or Au electrodes known as interdigitated transducers (IDTs) deposited on the surface. However, Al and Au both have shortcomings at the cryogenic temperatures required for quantum applications, namely, the formation of two-level systems and the lack of superconductivity perpetuating Ohmic losses, respectively. In this work, SAWs are generated in the high-MHz to low-GHz range using niobium nitride (NbN) interdigitated transducers and Bragg reflectors. We demonstrate the fabrication of acoustic devices through photolithography and reactive ion etching. The sharp transition between superconducting and normal states and the corresponding change in SAW transmission allows for fine control of the “on” (superconducting) and “off” (normal) states of NbN, with a ΔT = 1 K separating the transmission minimum and maximum. We demonstrate a 16× difference in transmission between the “on” and “off” states of the device. The SAW transmission behavior mirrors the change in resistance of NbN at its T c . These findings open up new possibilities for the integration of NbN SAW resonators into existing quantum architectures based on NbN and a method for adjusting transmission properties independent of applied voltage.

36 MATERIALS SCIENCE↗

Fibre laser system providing generation of frequency-modulated pulses with a spectral width exceeding the gain linewidth

We propose an improved scheme of an amplifier similariton laser with a spectral width of the output significantly exceeding the gain linewidth. In the system, an additional dispersion element is inserted into the cavity to provide a local increase in the peak pulse power. The proposed scheme allows a reduction of pulse duration and an increase in peak power of the output pulse after compression. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-BRD-01: An Automated Physics Weekly Chart Checking System Supporting ARIA

Purpose: A software tool was developed in this study to perform automatic weekly physics chart check on the patient data in ARIA. The tool accesses the electronic patient data directly from ARIA server and checks the accuracy of treatment deliveries, and generates reports which summarize the delivery history and highlight the errors. Methods: The tool has four modules. 1) The database interface is designed to directly access treatment delivery data from the ARIA database before reorganizing the data into the patient chart tree (PCT). 2) PCT is a core data structure designed to store and organize the data in logical hierarchies, and to be passed among functions. 3) The treatment data check module analyzes the organized data in PCT and stores the checking results into PCT. 4) Report generation module generates reports containing the treatment delivery summary, chart checking results and plots of daily treatment setup parameters (couch table positions, shifts of image guidance). The errors that are found by the tool are highlighted with colors. Results: The weekly check tool has been implemented in MATLAB and clinically tested at two major cancer centers. Javascript, cascading style sheets (CSS) and dynamic HTML were employed to create the user-interactive reports. It takes 0.06 second to search the delivery records of one beam with PCT and compare the delivery records with beam plan. The reports, saved in the HTML files on shared network folder, can be accessed by web browser on computers and mobile devices. Conclusion: The presented weekly check tool is useful to check the electronic patient treatment data in Varian ARIA system. It could be more efficient and reliable than the manually check by physicists. The work was partially supported by a research grant from Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Acoustic time-of-flight for proton range verification in water

Purpose: Measurement of the arrival times of thermoacoustic waves induced by pulsed proton dose depositions (protoacoustics) may provide a proton range verification method. The goal of this study is to characterize the required dose and protoacoustic proton range (distance) verification accuracy in a homogeneous water medium at a hospital-based clinical cyclotron. Methods: Gaussian-like proton pulses with 17 μs widths and instantaneous currents of 480 nA (5.6 × 10{sup 7} protons/pulse, 3.4 cGy/pulse at the Bragg peak) were generated by modulating the cyclotron proton source with a function generator. After energy degradation, the 190 MeV proton pulses irradiated a water phantom, and the generated protoacoustic emissions were measured by a hydrophone. The detector position and proton pulse characteristics were varied. The experimental results were compared to simulations. Different arrival time metrics derived from acoustic waveforms were compared, and the accuracy of protoacoustic time-of-flight distance calculations was assessed. Results: A 27 mPa noise level was observed in the treatment room during irradiation. At 5 cm from the proton beam, an average maximum pressure of 5.2 mPa/1 × 10{sup 7} protons (6.1 mGy at the Bragg peak) was measured after irradiation with a proton pulse with 10%–90% rise time of 11 μs. Simulation and experiment arrival times agreed well, and the observed 2.4 μs delay between simulation and experiment is attributed to the difference between the hydrophone’s acoustic and geometric centers. Based on protoacoustic arrival times, the beam axis position was measured to within (x, y) = (−2.0, 0.5) ± 1 mm. After deconvolution of the exciting proton pulse, the protoacoustic compression peak provided the most consistent measure of the distance to the Bragg peak, with an error distribution with mean = − 4.5 mm and standard deviation = 2.0 mm. Conclusions: Based on water tank measurements at a clinical hospital-based cyclotron, protoacoustics is a potential method for measuring the beam’s position (x and y within 2.0 mm) and Bragg peak range (2.0 mm standard deviation), although range verification will require simulation or experimental calibration to remove systematic error. Based on extrapolation, a protoacoustic arrival time reproducibility of 1.5 μs (2.2 mm) is achievable with 2 Gy of total deposited dose. Of the compared methods, deconvolution of the excitation proton pulse is the best technique for extracting protoacoustic arrival times, particularly if there is variation in the proton pulse shape.

07 ISOTOPE AND RADIATION SOURCES↗

Broadband rapid-scanning phase-modulated Fourier transform electronic spectroscopy

We present a phase-modulated approach for ultrabroadband Fourier transform electronic spectroscopy. To overcome the bandwidth limitations and spatial chirp introduced by acousto-optic modulators (AOMs), pulses from a 1 µm laser are modulated using AOMs prior to continuum generation. This phase modulation is transferred to the continuum generated in a yttrium aluminum garnet crystal. Separately generated phase-modulated continua in two arms of a Mach-Zehnder interferometer interfere with the difference of their modulation frequencies, enabling physical under-sampling of the signal and the suppression of low-frequency noise. By interferometrically tracking the relative time delay of the continua, we perform continuous, rapid-scanning Fourier transform electronic spectroscopy with a high signal-to-noise ratio and spectral resolution. As proof of principle, we measure the linear absorption and fluorescence excitation spectra of a laser dye and various biological samples.

Javed, Ariba↗

Flexible Design for Steam Generation in an SMR Module

The intermediate heat exchanger is a key aspect of the JUMP tertiary loop. An IHX will be required as an interface between the main steam side and secondary side of the NuScale Power Module and coupled TES or energy users. This project examines the preliminary design of the IHX to establish a design range for detailed design and explore the relationships between variables.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bench scale Testing of Next Generation Hollow Fiber Membrane Modules at subambient conditions at the National Carbon Capture Center

Air Liquide is developing a hybrid CO2 capture process based on sub-ambient temperature hollow-fiber membrane operation in combination with cryogenic distillation (Ref 1, 2, 3). Prior work has shown extremely attractive membrane performance. The current work seeks to demonstrate performance of the novel membrane fiber, in commercial form, with flue gas from a coal fired power plant.

Hasse, Dave↗

Next Generation Fast RF Interlock Module and ATCA Adapter for ILC High Availability RF Test Station Demonstration

High availability interlocks and controls are required for the ILC (International Linear Collider) L-Band high power RF stations. A new F3 (Fast Fault Finder) VME module has been developed to process both fast and slow interlocks using FPGA logic to detect the interlock trip excursions. This combination eliminates the need for separate PLC (Programmable Logic Controller) control of slow interlocks. Modules are chained together to accommodate as many inputs as needed. In the next phase of development the F3's will be ported to the new industry standard ATCA (Advanced Telecom Computing Architecture) crate (shelf) via a specially designed VME adapter module with IPMI (Intelligent Platform Management Interface). The goal is to demonstrate auto-failover and hot-swap for future partially redundant systems.

43 PARTICLE ACCELERATORS↗

Experimental generation of longitudinally-modulated electron beams using an emittance exchange technique

We report our experimental demonstration of longitudinal phase space modulation using a transverse-to-longitudinal emittance exchange technique. The experiment is carried out at the A0 photoinjector at Fermi National Accelerator Lab. A vertical multi-slit plate is inserted into the beamline prior to the emittance exchange, thus introducing beam horizontal profile modulation. After the emittance exchange, the longitudinal phase space coordinates (energy and time structures) of the beam are modulated accordingly. This is a clear demonstration of the transverse-to-longitudinal phase space exchange. In this paper, we present our experimental results on the measurement of energy profile as well as numerical simulations of the experiment.

43 PARTICLE ACCELERATORS↗

Using an Emittance Exchange Scheme for High Harmonic Generation by Free-Electron Lasers

We propose combining a transverse-to-longitudinal emittance exchange beam line and a conventional modulator to generate high harmonics with short-wavelength free-electron lasers. The key point of this scheme is the use of a multi-slit mask to create a transverse-shaped beam. In an emittance exchange beam line, the transverse-shaped bunch will produce a longitudinal-shaped one, resulting in separated energy bands. The modulator that follows this step will generate micro-bunches containing high harmonics. A coherent synchrotron radiation effect is also considered in this paper; compared to the two-modulator scheme, the method investigated here is more flexible and can be used to relax the coherent synchrotron radiation effect.

43 PARTICLE ACCELERATORS↗

Continuous third harmonic generation in a terahertz driven modulated nanowire

We consider the possibility of observing continuous third-harmonic generation using a strongly driven, single-band one-dimensional metal. In the absence of scattering, the quantum efficiency of frequency tripling for such a system can be as high as 93%. Combining the Floquet quasi-energy spectrum with the Keldysh Green's function technique, we derive a semiclassical master equation for a one-dimensional band of strongly and rapidly driven electrons in the presence of weak scattering by phonons. The power absorbed from the driving field is continuously dissipated by phonon modes, leading to a quasi-equilibrium in the electron distribution. We use the Kronig-Penney model with varying effective mass to establish the growth parameters of an InAs/InP nanowire near optimal for third harmonic generation at terahertz frequency range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New generation polyphase resonant converter-modulators for the Korean atomic energy research institute

This paper will present operational data and performance parameters of the newest generation polyphase resonant high voltage converter modulator (HVCM) as developed and delivered to the KAERI 100 MeV ''PEFP'' accelerator [1]. The KAERI design realizes improvements from the SNS and SLAC designs [2]. To improve the IGBT switching performance at 20 kHz for the KAERI system, the HVCM utilizes the typical zero-voltage-switching (ZVS) at turn on and as well as artificial zero-current-switching (ZCS) at turn-off. The new technique of artificial ZCS technique should result in a 6 fold reduction of IGBT switching losses (3). This improves the HCVM conversion efficiency to better than 95% at full average power, which is 500 kW for the KAERI two klystron 105 kV, 50 A application. The artificial ZCS is accomplished by placing a resonant RLC circuit across the input busswork to the resonant boost transformer. This secondary resonant circuit provides a damped ''kick-back'' to assist in IGBT commutation. As the transformer input busswork is extremely low inductance (< 10 nH), the single RLC network acts like it is across each of the four IGBT collector-emitter terminals of the H-bridge switching network. We will review these topological improvements and the overall system as delivered to the KAERI accelerator and provide details of the operational results.

43 PARTICLE ACCELERATORS↗

Multigroup Cross-Section Generation with the OpenMC Monte Carlo Particle Transport Code

High-fidelity deterministic transport codes require highly accurate multigroup cross sections (MGXS). Monte Carlo is increasingly cited as a reactor-agnostic approach to MGXS generation since it is unconstrained by the engineering-based approximations that limit the applicability of deterministic MGXS generation tools. This paper introduces a new framework that uses the OpenMC Monte Carlo code to generate MGXS for use in multigroup transport codes. The openmc.mgxs module is built atop OpenMC's Python application programming interface to process tally data output by the OpenMC executable. This paper validates the module to generate MGXS that enable the multigroup OpenMOC transport code to compute eigenvalues to within 50 pcm and fission rates to within 1% of reference solutions for two heterogeneous pressurized water reactor benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of Prostate-Rectum Separation on Rectal Dose From External Beam Radiotherapy

Purpose: In radiotherapy for prostate cancer, the rectum is the major dose-limiting structure. Physically separating the rectum from the prostate (e.g., by injecting a spacer) can reduce the rectal radiation dose. Despite pilot clinical studies, no careful analysis has been done of the risks, benefits, and dosimetric effects of this practice. Methods and Materials: Using cadaveric specimens, 20 mL of a hydrogel was injected between the prostate and rectum using a transperineal approach. Imaging was performed before and after spacer placement, and the cadavers were subsequently dissected. Ten intensity-modulated radiotherapy plans were generated (five before and five after separation), allowing for characterization of the rectal dose reduction. To quantify the amount of prostate-rectum separation needed for effective rectal dose reduction, simulations were performed using nine clinically generated intensity-modulated radiotherapy plans. Results: In the cadaveric studies, an average of 12.5 mm of prostate-rectum separation was generated with the 20-mL hydrogel injections (the seminal vesicles were also separated from the rectum). The average rectal volume receiving 70 Gy decreased from 19.9% to 4.5% (p < .05). In the simulation studies, a prostate-rectum separation of 10 mm was sufficient to reduce the mean rectal volume receiving 70 Gy by 83.1% (p <.05). No additional reduction in the average rectal volume receiving 70 Gy was noted after 15 mm of separation. In addition, spacer placement allowed for increased planning target volume margins without exceeding the rectal dose tolerance. Conclusion: Prostate-rectum spacers can allow for reduced rectal toxicity rates, treatment intensification, and/or reduced dependence on complex planning and treatment delivery techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗