Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Report on the Assessment of Ion Irradiations on High Entropy Alloys

Idaho National Laboratory (INL) initiated a joint international effort with the Czech Republic to explore the feasibility of manufacturing High Entropy Alloys for high-temperature nuclear applications using Additive Manufacturing. This effort was funded at INL by the United States Department of Energy’s Office of Nuclear Energy under the Advanced Reactor Technologies and Advanced Materials and Manufacturing Technologies (AMMT) Program. The High Entropy Alloys were specifically designed for the corrosive and irradiation environments as experienced in gas fast reactors, molten salt reactors, and fusion power. These alloys were manufactured by multiple processes to determine the impact of manufacturing processes on the performance of the alloys in corrosive and irradiation environments. Preliminary results show that MoNbTiV and MoNbTi alloys exhibit no degradation after multiple corrosion tests. These MoNbTiV and MoNbTi alloys were also evaluated after irradiation experiments were conducted at the Michigan Ion Beam Laboratory at the University of Michigan, which is the focus of this milestone report. For these irradiation experiments, the MoNbTiV and MoNbTi alloys manufactured by arc melting and Electric Field Assisted Sintering (EFAS) were tested at 500 C at a dose of 30 dpa to evaluate the microstructural stability and decomposition.

36 - MATERIALS SCIENCE↗

Flavor, transverse momentum, and azimuthal dependence of charged pion multiplicities in semi-inclusive deep-inelastic scattering with 10.6 GeV electrons

Measurements of semi-inclusive deep-inelastic scattering multiplicities for 𝜋 + and 𝜋 − from proton and deuteron targets are reported on a grid of hadron kinematic variables 𝑧, 𝑃 𝑇 , and 𝜙* for leptonic kinematic variables in the range 0.3<𝑥<0.6 and 3<𝑄 2 <5GeV 2 . Data were acquired in 2018 and 2019 at Jefferson Lab Hall C with a 10.6 GeV electron beam impinging on 10-cm-long liquid hydrogen and deuterium targets. Scattered electrons and charged pions were detected in the High Momentum Spectrometer and Super High Momentum Spectrometer, respectively. The multiplicities were fitted for each bin in (𝑥,𝑄 2 ,𝑧,𝑃𝑡) to extract the 𝜙*—independent 𝑀 0 and the azimuthal modulations ⟨cos⁡(𝜙*)⟩ and ⟨cos⁡(2⁢𝜙*)⟩. The 𝑃𝑡 dependence of the 𝑀 0 results was found to be remarkably consistent for the four cases studied: 𝑒⁢𝑝→𝑒⁢𝜋 + ⁢𝑋, 𝑒⁢𝑝→𝑒⁢𝜋 − ⁢𝑋, 𝑒⁢𝑑→𝑒⁢𝜋 + ⁢𝑋, 𝑒⁢𝑑→𝑒⁢𝜋 − ⁢𝑋 over the range 0GeV<𝑃 𝑡 <0.4GeV, as were the multiplicities evaluated near 𝜙*=180∘ over the extended range 0GeV<𝑃 𝑡 <0.7GeV. The Gaussian widths of the 𝑃 𝑡 dependence exhibit a quadratic increase with 𝑧. The cos⁡(𝜙*) modulations were found to be consistent with zero for 𝜋 + , in agreement with previous world data, while the 𝜋 − moments were, in many cases, significantly greater than zero. The cos⁡(2⁢𝜙*) modulations were found to be consistent with zero. The higher statistical precision of this dataset of about 20 000 individual multiplicity values, compared with previously published data, should allow improved determinations of quark transverse momentum distributions and higher twist contributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Timing reconstruction utilising multiple detection subsystems at the Short-Baseline Near Detector experiment

The Short-Baseline Near Detector (SBND) is the near detector of the Short-Baseline Neutrino Program, located only 110 m away from the Booster Neutrino Beam (BNB) target at Fermilab (Illinois, USA). SBND employs key detection technologies: a 112-ton Liquid Argon Time Projection Chamber for ionisation electrons, an advanced Photon Detection System (PDS) made up of photomultiplier tubes and X-ARAPUCAs for scintillation light, and a 4π coverage of Cosmic Ray Taggers (CRTs) for cosmic muons. This setup offers an exceptional energy, spatial and timing reconstruction of neutrino interactions. In this poster, we present ongoing timing reconstruction efforts of the PDS and CRTs, as well as combining complementary information across multiple detection subsystems to improve the timing resolution. This results in nanosecond level timing information that can be leveraged as an analysis tool, including the reconstruction of the BNB substructure to accept or reject signals detected in-between neutrino bunches as well as a timing-based discrimination for cosmic rejection.

Corallo, Annalea [INFN, Ferrara]↗

Multi-Beam-Energy Control Unit Based on Triple-Bend Achromats

X-ray free electron lasers (XFELs) are the new generation of particle accelerator-based light sources, capable of producing tunable, high-power X-ray pulses that are increasingly vital across various scientific disciplines. Recently, continuous-wave (CW) XFELs driven by superconducting linear accelerators have garnered significant attention due to their ability to enhance availability by supporting multiple undulator lines simultaneously. In this paper, we introduce a novel delay system comprising four triple-bend achromats (TBAs). This delay system was combined with fast kickers and can be employed to generate electron beams on a bunch-to-bunch basis in a CW-XFEL facility. Based on the parameters of the Shanghai High-Repetition-Rate XFEL and Extreme Light Facility, start-to-end simulations demonstrate that the TBA-based delay system achieves excellent electron beam qualities while providing a wide beam-energy-tuning range from 1.39 to 8 GeV.

43 PARTICLE ACCELERATORS↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of the Pair Spectrometer in Hall D at Jefferson Lab

This article describes the performance of the pair spectrometer installed in experimental Hall D at Jefferson Lab and its successfully operation in multiple experiments with the GlueX detector. The primary purpose of the pair spectrometer is the precise determination of the flux of beam photons incident on the GlueX target, a critical input for physics analyses such as absolute cross-section measurements. The photon energy spectrum is determined by reconstructing electron–positron pairs produced in a thin converter inserted into the photon beam. The spectrometer is integrated into the GlueX trigger system, whose electronics enable continuous real-time monitoring of the photon flux and the recording of e+e- pair candidates for offline analysis. In addition, the pair spectrometer provides a versatile test facility for evaluating calorimeter prototypes using leptons with well-defined energies produced via electromagnetic pair production.

Somov, Alexander [Jefferson Lab]↗

High-n Rydberg transition spectroscopy for heavy impurity transport studies in W7-X (invited)

Here, we present a novel spectroscopy approach to investigate impurity transport by analyzing line-radiation following high-n Rydberg transitions. While high-n Rydberg states of impurity ions are unlikely to be populated via impact excitation, they can be accessed by charge exchange (CX) reactions along the neutral beams in high-temperature plasmas. Hence, localized radiation of highly ionized impurities, free of passive contributions, can be observed at multiple wavelengths in the visible range. For the analysis and modeling of the observed Rydberg transitions, a technique for calculating effective emission coefficients is presented that can well reproduce the energy dependence seen in datasets available on the OPEN-ADAS database. By using the rate coefficients and comparing modeling results with the new high-n Rydberg CX measurements, impurity transport coefficients are determined with well-documented 2σ confidence intervals for the first time. This demonstrates that high-n Rydberg spectroscopy provides important constraints on the determination of impurity transport coefficients. By additionally considering Bolometer measurements, which provide constraints on the overall impurity emissivity and, therefore, impurity densities, error bars can be reduced even further.

Instruments & Instrumentation↗

Upper Limit for the 248 Cm( 50 Ti, x n) 298− x Og Reaction Cross Section

After the synthesis of element 113, nihonium (Nh) via the 209 Bi( 70 Zn,n) 278 Nh cold fusion reaction using the RIKEN heavy-ion Linear ACcelerator (RILAC) and the GAs-filled Recoil Ion Separator (GARIS), the search for the heaviest isotopes of oganesson was initiated with GARIS-II by means of the 248 Cm( 50 Ti,xn) 298−x Og fusion evaporation reaction. The optimal bombarding energy for the 50 Ti + 248 Cm reaction was determined from the quasielastic barrier distribution extracted from the excitation function of quasielastic backscattering. Here, this method optimizes the compound nucleus formation. The search for Og was conducted for 39 days on the basis of the experimentally derived 50 Ti beam energy of 227.9(5) MeV at the middle of 248 Cm target. A precise analysis of the dataset based on multiple event search strategies revealed no decay chains with a total dose on 248 Cm target of 4.93 × 10 18 50 Ti projectiles, reaching a sensitivity of 0.27 pb and a 1σ upper cross section limit of 0.50 pb.

Gall, Benoît Jean-Paul [University of Strasbourg (↗

Neutrino Dipole Moments and Radiative Signatures from Partial Compositeness

We investigate composite neutrino models where heavy neutrinos emerge as bound states from a near-conformal strongly coupled sector. Standard Model neutrinos mix with these composite singlets via an inverse seesaw mechanism, where the anomalous scaling dimensions of the composite-sector operators naturally suppress light neutrino masses to sub-eV scales. Matching the conformal dynamics onto low-energy theory yields enhanced electromagnetic transition dipole operators with couplings $d_{μN} \sim 10^{-6}$-$10^{-8}\,\mathrm{GeV}^{-1}$, parametrically larger than the loop-level predictions of minimal Dirac or Majorana models. We carry out a dedicated event-level simulation of the production-and-decay chain $νX \to \mathcal{U} X \to νγX$ and compute the resulting event rates at MiniBooNE and MINERvA within the model, accounting for the composite production cross section and decay kinematics in detail. We further present predictions for the photon energy, angular, and multiplicity distributions. For the benchmark scenarios accessible at these experiments the radiative signal is predominantly single-photon; the composite structure additionally permits fragmentation of the up-scattered state into multiple heavy neutrinos, each decaying as $N\toνγ$, with multi-photon final states emerging for lighter compositeness scales or higher beam energies as a qualitatively new probe of the composite dynamics.

Assi, Benoît [Cincinnati U.; Fermilab] (ORCID:0000↗

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT ↗

Resistive Wall Simulations for the DARHT Multi-Pulse Test Line

The multi-pulse test line (MPTL) presently under T development at the Dual Axis Radiography Hydrodynamic Test (DARHT) facility may have several meters of drifting beam transport without external magnetic focusing field. The absence of external magnetic focusing is the worst case for growth of the resistive-wall instability. This instability is usually considered to be strictly a long-pulse (low-frequency) problem, but has been theoretically shown to couple the multiple pulses in a long pulse train, such as are expected to be the subject of experimentation on the MPTL. In this note, we explore the resistive wall instability in the MPTL parameter range using our LAMDA beam dynamics code. (LAMDA stands for Linear Accelerator Model for DARHT)

43 PARTICLE ACCELERATORS↗

Digital twin framework for PIP-II linac: AI-driven multi-scale modeling from ion source to 800 MeV

The PIP-II superconducting linac at Fermilab is designed to deliver multi-megawatt proton beams for neutrino physics and other high-intensity applications. To expedite commissioning and enhance operational reliability, we have developed an EPICS-based data flow framework that seamlessly integrates digital twins (DT) with physical twins (PT). These digital twins comprise high-fidelity beam dynamics models or data-driven surrogate models connected to their physical counterparts through real-time diagnostics and advanced machine-learning algorithms.Central to this framework is Linac_Gen, an accelerated simulation tool that incorporates convolutional neural networks, random forests, and genetic algorithms to provide up to a tenfold speedup in optimizing the accelerator geometry model. An EPICS translator layer ensures interoperability by efficiently mapping lattice parameters across diverse simulation platforms.Our EPICS-based framework supports multiple operational modes—monitoring, passive learning, closed-loop control, and online learning—covering the entire machine lifecycle. By leveraging HPC resources and multi-objective optimization techniques, the digital twin enables adaptive trajectory correction, real-time fault detection, and predictive modeling of beam stability. This comprehensive approach paves the way for robust, high-intensity operation and data-driven accelerator R&D at Fermilab.

Pathak, Abhishek [Fermilab]↗

Tailoring coherent charge transport in graphene by deterministic defect generation

Harnessing the wave-nature of charge carriers in solid state devices, electron optics investigates and exploits coherent phenomena, in analogy with optics and photonics. Typically, this requires complex electronic devices leveraging macroscopically coherent charge transport in two-dimensional electron gases and superconductors. Here, collective coherent effects are induced in a simple counterintuitive architecture by defect engineering. Deterministically introduced lattice defects in graphene enable the phase coherent charge transport by playing the role of potential barriers, instead of scattering centres as conventionally considered. Thus, graphene preserves its quasi-ballistic quantum transport and can support phase-matched charge carrier waves. Based on this approach, multiple electronic Fabry-Pèrot cavities are formed by creating periodically alternating defective and pristine nano-stripes through low energy electron-beam irradiation. Indeed, defective stripes behave as partially reflecting mirrors and resonantly confine the charge carrier waves within the pristine areas, giving rise to Fabry-Pèrot resonant modes. These modes experimentally manifest as sheet resistance oscillations, as also confirmed by Landauer-Büttiker simulations. Moreover, these coherent phenomena survive up to 30 K for both polarities of charge carriers, contrarily to traditional monopolar electrostatically created Fabry-Pèrot interferometers. Our study positions defective graphene as an innovative platform for coherent electronic devices, with potential applications in nano and quantum technologies.

Melchioni, Nicola↗

Scalable phononic metamaterials: Tunable bandgap design and multi-scale experimental validation

Phononic metamaterials offer unprecedented control over wave propagation, making them essential for applications such as vibration isolation, waveguiding, and acoustic filtering. However, achieving scalable and precisely tunable bandgap properties across different length scales remains challenging. This study presents a user-friendly design framework for phononic metamaterials, enabling ultra-wide bandgap tunability (B/ω c ratios up to 172 %) across multiple frequency ranges and scales. Using finite element simulations of a Yablonovite-inspired unit cell, we establish a comprehensive parametric design space that illustrates how geometric parameters, such as sphere size and beam diameter, controls bandgap width and frequency. The scalability and robustness of the framework are validated through experimental testing on additively manufactured structures at both macro (10 mm) and micro (80 µm) scales, fabricated using Stereolithography and Two-Photon Polymerization. Transmission loss measurements, conducted with piezoelectric transducers and laser vibrometry, closely match simulations in the kHz and MHz frequency ranges, confirming the reliability and consistency of the bandgap behavior across scales. This work bridges theory and experiments at multiple scales, offering a practical methodology for the rapid design of phononic metamaterials and expanding their potential for diverse applications across a broad range of frequencies.

36 MATERIALS SCIENCE↗

Fluoro‐Ethylene‐Carbonate Plays a Double‐Edged Role on the Stability of Si Anode‐Based Rechargeable Batteries During Cycling and Calendar Aging

Abstract The energy storage density of Li‐ion batteries can be improved by replacing graphite anodes with high‐capacity Si‐based materials, though instabilities have limited their implementation. Performance degradation mechanisms that occur in Si anodes can be divided into cycling stability (capacity retention after repeated battery cycles) and calendar aging (shelf life). While cycling instabilities and improvement strategies have been researched intensively, there is little known about the underlying mechanisms that cause calendar aging. In this work, multiple electron microscope techniques are used to explore the mechanism that governs calendar aging from the sub‐nanometer‐to‐electrode scale. Plasma focused ion beam tomography is used to create 3D reconstructions of calendar aged electrodes and revealed the growth of a LiF‐rich layer at the interface between the copper current collector and the silicon material, which can lead to delamination and increased interfacial impendence. The LiF layer appeared to derive from the fluoro‐ethylene‐carbonate electrolyte additive, which is commonly used to improve cycling stability in Si‐based systems. The results reveal that additives necessary to improve cycling stability can cause performance degradation over the long‐term during calendar aging. The results show that high performing, stable systems require careful design to simultaneously mitigate both cycling and calendar aging instabilities.

25 ENERGY STORAGE↗

From the Lab to your Sewage Plant – Accelerators for Environmental Applications

The history of environmental applications of ionizing irradiation dates back to the 80s and 90s of the last century. Electron beam has proven to be a useful tool for the treatment of industrial waste water and flue gases and is already in use in multiple pilot plants in East Europe and Asia. It also offers a new alternative for tackling rising challenges for the wastewater treatment industry of the future in form of newly discovered harmful contaminants. The talk presents developments that enable a technology transfer of well-established superconducting accelerator technology from science to this field of environmental applications with a focus on water treatment. Recent achievements and future concepts are summarized with an emphasis on the pioneering work done at Jefferson Lab.

Vennekate, Hannes↗

Measuring the neutrino-oxygen neutral current quasielastic cross section using the accelerator neutrino neutron interaction experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-doped water Cherenkov detector located on-axis to Fermilab’s Booster Neutrino Beam (BNB). ANNIE is uniquely positioned to perform high-statistics measurements of neutrino-nucleus interactions in water, benefiting from a large neutrino flux due to a short (100-meter) baseline. A central focus of ANNIE’s physics program is the measurement of both charged current (CC) and neutral current (NC) cross sections on water, including neutral current quasielastic (NCQE) and CC-inclusive channels. The NCQE measurement is particularly critical for constraining uncertainties in rare-event searches such as the Diffuse Supernova Neutrino Background (DSNB), where atmospheric $\nu$NCQE interactions constitute a significant and poorly constrained background. This dissertation presents a measurement of the flux-averaged neutrino-oxygen neutral current quasielastic ($\nu$NCQE) cross section using $2.573 \times 10^{20}$~POT of BNB exposure from the 2022 and 2023 beam years. The $\nu$NCQE interaction is identified through the primary $\gamma$-rays produced by nuclear de-excitation of the residual $^{15}$N$^*$ or $^{15}$O$^*$ nucleus following nucleon knockout from $^{16}$O. A dedicated Monte Carlo (MC) re-tuning campaign was conducted using an americium-beryllium (AmBe) calibration source, Michel electrons from stopped muons, and throughgoing dirt muons originating upstream of the detector. This multi-sample approach provided a wide-ranging $\mathcal{O}(\text{MeV})$--$\mathcal{O}(\text{GeV})$ dataset for tuning the simulated detector response, which was subsequently validated against AmBe neutron and Michel electron data for use in the $\nu$NCQE analysis. A dedicated laser calibration campaign was carried out to reduce timing uncertainties across the PMT system, enabling reconstruction of the BNB bunch substructure with sufficient resolution to serve as a background rejection tool. By selecting events in-time with individual neutrino bunches, beam-correlated $\nu$NCQE events are separated from diffuse and accelerator-induced backgrounds, notably skyshine neutrons and externally-originating events, that would otherwise dominate traditional charge-based selections within a small-scale, surface-level, short-baseline detector. A data-driven estimation of the skyshine neutron and external background rates was performed and incorporated into the systematic uncertainty budget. The flux-averaged $\nu$NCQE cross section on oxygen is measured to be $1.57 \pm 0.06\,(\text{stat.})$ $^{+0.91}_{-0.67}\,(\text{syst.})$ $\times 10^{-38}\ \text{cm}^{2}$. A full systematic budget is constructed by propagating uncertainties in the secondary hadronic interaction modeling, background cross section normalizations, detector response, neutrino flux, and the primary $\gamma$-ray emission probabilities from oxygen nuclear de-excitation. An idealized de-excitation model, constructed from existing measurements in the literature is developed to benchmark the predictions of the \textsc{GENIE} event generator. A comparison reveals that \textsc{GENIE} systematically overpredicts the primary $\gamma$-ray emission probability from oxygen de-excitation by a factor of $1.49\times$ for $E_\gamma > 6$~MeV and $3.07\times$ in the $3$--$6$~MeV band. This comparison motivates the dominant systematic uncertainty in this analysis, where a conservative uncertainty of $^{+39.9\%}_{-0\%}$ on the primary $\gamma$-ray signal prediction is assigned. The ANNIE result is consistent with and complementary to existing flux-averaged $\nu$NCQE cross section measurements from T2K and Super-Kamiokande, providing an independent measurement with a different detector, neutrino beam, and analysis methodology. Looking ahead, an upgrade to the ANNIE DAQ infrastructure enabling continuous extended readout will allow a complementary $\nu$NCQE neutron multiplicity measurement, directly relevant to constraining the NCQE background in DSNB searches, competitive with the recent T2K measurement at SK-Gd. The planned Super-SANDI upgrade, deploying a large Water-based Liquid Scintillator (WbLS) volume, will further extend ANNIE's reach to hadronic final states and exclusive NC channels, and enable joint measurements with liquid argon detectors sharing the BNB beamline ahead of DUNE and Hyper-Kamiokande.

Doran, Steven [Iowa State U.]↗

Fermilab PIP II machine protection system digitized data noise elimination scheme and its FPGA implementation

In Fermilab's PIP-II machine protection system, beam loss signals from various detectors are digitized at 125 MS/s. Noise from both high-frequency sources and low-frequency 60 Hz AC power equipment can contaminate the data. To suppress noise across these ranges especially 60 Hz and its harmonics, which overlap with beam loss signal frequencies advanced digital processing beyond standard filtering is required. Several real-time functional blocks were simulated and tested on an FPGA: (1) a dual time-constant discharging integrator filter, (2) a de-ripple baseline extraction and storage block, and (3) a fast-recovery discharging integrator. The nonlinear IIR integrator filter removes high-frequency noise and feeds into the baseline extractor. Upon detecting abrupt beam loss, it switches to a longer time constant to prevent baseline distortion. The de-ripple block calculates a valid baseline by averaging over multiple 60 Hz periods, storing results in a 4096-word FPGA RAM. This baseline is subtracted from raw data before integration by the fast-recovery block, which resets quickly after use. All blocks achieved expected performance.

Wu, J. [Fermilab] (ORCID:0000000344329521)↗