Search NASA⌕ Search

SEARCH · Search NASA

Results for “noninvasive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Comparative Evaluation of Spectral Methods for Robust Reactor Noise Estimation

Reactor noise analysis provides a noninvasive means to determine neutron kinetic parameters from stochastic fluctuations in detector signals. However, standard cross-power spectral density (CPSD) analyses can be sensitive to numerical processing choices, which may introduce processing-dependent systematic shifts in estimates of the prompt neutron decay constant (α) and limit reproducibility. This study uses a hybrid multitaper–Welch spectral estimator to analyze subcritical noise measurements from a fast-spectrum critical assembly. The decay constant α was extracted using three frequency-domain methods: the CPSD, the magnitude-squared coherence (MSC), and the generalized magnitude-squared coherence (GMSC). These coherence-based estimators normalize detector auto-spectral structure and are expected to reduce the sensitivity of fitted α values to processing parameters. A Sobol global sensitivity analysis identified which numerical inputs most strongly influence the fitted values of α. All estimators produced a linear dependence of α on inverse count rate, with delayed-critical extrapolations near 1.7 × 10 4 s −1 , in agreement within 8% of MCNP6.3 KOPTS benchmark calculations. Sensitivity results show that while the CPSD depends on both time-bin width and taper selection, the MSC and GMSC are dominated by time-bin width alone, indicating reduced parameter coupling and greater robustness to processing variability. These findings demonstrate the feasibility and practical value of coherence-based spectral estimators for extracting α from reactor noise and support their broader application to multi-detector and irregular datasets in subcritical system characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Analytical Investigation of Arsenical Transfer and Remediation on Nineteenth-Century Green Books

Books containing heavy metals, specifically nineteenth-century green arsenical books, have been identified at Northwestern University Libraries, raising health and safety concerns related to handling. Copper acetoarsenite pigments, such as emerald green, were detected on book covers, decorative page edges, labels, and other components using noninvasive analytical techniques including X-ray fluorescence (XRF), Raman spectroscopy, and Fourier-transform infrared (FTIR) spectroscopy. Further examination of selected volumes using synchrotron radiation (SR) techniques revealed pigment migration, degradation, and arsenic transfer to adjacent books. This paper expands on initial findings through two related experiments. The first explored the transfer of arsenic using mechanical friction; Staedtler Mars® white vinyl erasers rubbed on arsenical books generated crumbs which were analyzed via scanning electron microscopy–energy-dispersive X-ray spectroscopy (SEM-EDX). Results confirmed the transfer of arsenic, copper, and lead, with decorative page edges being particularly prone to shedding arsenic onto other materials. The second experiment tested remediation methods on a book contaminated by prolonged exposure to an arsenical neighbor. Surface cleaning using erasers and a vacuum removed flecks of pigment but did not eliminate non-chromophoric arsenic as confirmed by SR analyses, which highlights its presence either as a degradation product embedded within the paper or present in the paper as part of its production process. Findings demonstrate the acute toxicity risk posed by arsenical books and support the need for safe handling protocols. However, materials with only trace levels of arsenic embedded during production may pose a lower risk of transfer. Cross contamination beyond prolonged direct contact appears limited. These results highlight critical considerations for library preservation practices and future research on arsenic in historical materials.

arsenic↗

Quantifying and Visualizing Uncertainty for Source Localisation in Electrocardiographic Imaging

Electrocardiographic imaging (ECGI) presents a clinical opportunity to noninvasively understand the sources of arrhythmias for individual patients. To help increase the effectiveness of ECGI, we provide new ways to visualise associated measurement and modelling errors. Here, we study source localisation uncertainty in two steps: First, we perform Monte Carlo simulations of a simple inverse ECGI source localisation model with error sampling to understand the variations in ECGI solutions. Second, we present multiple visualisation techniques, including confidence maps, level-sets, and topology-based visualisations, to better understand uncertainty in source localization. Our approach offers a new way to study uncertainty in the ECGI pipeline.

47 OTHER INSTRUMENTATION↗

Terahertz conductivity of two-dimensional materials: a review

Two-dimensional (2D) van der Waals materials are shaping the landscape of next-generation devices, offering significant technological value thanks to their unique, tunable, and layer-dependent electronic and optoelectronic properties. Time-domain spectroscopic techniques at terahertz (THz) frequencies offer noninvasive, contact-free methods for characterizing the dynamics of carriers in 2D materials. They also pave the path toward the applications of 2D materials in detection, imaging, manufacturing, and communication within the increasingly important THz frequency range. In this paper, we overview the synthesis of 2D materials and the prominent THz spectroscopy techniques: THz time-domain spectroscopy, optical-pump THz-probe technique, and optical pump–probe THz spectroscopy. Through a confluence of experimental findings, numerical simulation, and theoretical analysis, we present the current understanding of the rich ultrafast physics of technologically significant 2D materials: graphene, transition metal dichalcogenides, MXenes, perovskites, topological 2D materials, and 2D heterostructures. Finally, we offer a perspective on the role of THz characterization in guiding future research and in the quest for ideal 2D materials for new applications.

2D materials↗

High spatial resolution direct conversion amorphous selenium X-ray detectors with monolithically integrated CMOS readout

Recent progress in the field of micron-scale spatial resolution direct conversion X-ray detectors for high-energy synchrotron light sources serve applications ranging from nondestructive and noninvasive microscopy techniques which provide insight into the structure and morphology of crystals, to medical diagnostic measurement devices. Amorphous selenium ( a -Se) as a wide-bandgap thermally evaporated photoconductor exhibits ultra-low thermal generation rates for dark carriers and has been extensively used in X-ray medical imaging. Being an amorphous material, it can further be deposited over large areas at room temperatures and at substantially lower costs as compared to crystalline semiconductors. Here, to address the demands for a high-energy and high spatial resolution X-ray detector for synchrotron light source applications, we have thermally evaporated a -Se on a Mixed-Mode Pixel Array Detector (MM-PAD) Application Specific Integrated Circuit (ASIC). The ASIC format consists of 128 × 128 square pixels each 150 μm on a side. A 200 μm a -Se layer was directly deposited on the ASIC followed by a metal top electrode. The completed detector assembly was tested with 45 kV Ag and 23 kV Cu X-ray tube sources. The detector fabrication, performances, Modulation Transfer Function (MTF) measurements, and simulations are reported.

36 MATERIALS SCIENCE↗

A device for volatile organic compound (VOC) analysis from skin using heated dynamic headspace sampling

Abstract Human skin is an important source of volatile organic compounds (VOCs) offering noninvasive methods to gain clinical metabolite information. This work was focused on the development of a skin sampling device based on a dynamic headspace sampling method with the addition of temperature to increase VOC metabolite recovery. The device preconcentrates skin VOC emissions onto a sorbent substrate, which can either be preserved for offline analysis or attached to a real time sensor downstream. In this work, skin VOC samples were analyzed offline using thermal desorption-gas chromatography-mass spectrometry. A list of 10 common skin VOCs was pre-selected to optimize parameters of sampling time, sampling temperature, and sorbent selection. Overall, this study highlights an effective skin VOC sampling technology with a heating dimension (40 °C, rather than 30 °C or no heating) with a sampling time of 15 min (rather than 5 or 30 mins) and onto Tenax TA sorbent (rather than PDMS), which collectively increases the recovery of compounds with lower vapor pressure and decreases the observed variability in skin VOC measurements. Finally, a list of 79 skin VOC compounds were detected and identified within a cohort of 20 young, healthy volunteers.

Biochemistry & Molecular Biology↗

Characterizing the effect of incrementally increasing dry bulb temperature on linear and nonlinear measures of heart rate variability in nonpregnant, mid-gestation, and late-gestation sows

Abstract Characterizing the sow physiological response to an increased heat load is essential for effective heat stress mitigation. The study objective was to characterize the effects of a 400-min heating episode on sow heart rate variability (HRV) at different reproductive stages. HRV is a commonly used noninvasive proxy measure of autonomic function. Twenty-seven sows were enrolled in the study according to their gestation stage at time of selection: 1) nonpregnant (NP; n = 7), 2) mid-gestation (MID; 57.3 ± 11.8 d gestation; n = 11), and 3) late-gestation (LATE; 98.8 ± 4.9 d gestation; n = 8). The HRV data utilized in the study were collected from each pig as the dry bulb temperature in the room increased incrementally from 19.84 ± 2.15 °C to 35.54 ± 0.43 °C (range: 17.1–37.5 °C) over a 400-min period. After data collection, one 5-min set of continuous heart rate data were identified per pig for each of nine temperature intervals (19–20.99, 21–22.99, 23–24.99, 25–26.99, 27–28.99, 29–30.99, 31–32.99, 33–34.99, and 35–36.99 °C). Mean inter-beat interval length (RR), standard deviation of r-r intervals (SDNN), root mean square of successive differences (RMSSD), high frequency spectral power (HF), sample entropy (SampEn), short-term detrended fluctuation analysis (DFAα1), and three measures (%REC, DET, LMEAN) derived from recurrence quantification analysis were calculated for each data set. All data were analyzed using the PROC GLIMMIX procedure in SAS 9.4. Overall, LATE sows exhibited lower RR than NP sows (P < 0.01). The standard deviation of r–r intervals and RMSSD differed between each group (P < 0.01), with LATE sows exhibiting the lowest SDNN and RMSSD and NP sows exhibiting the greatest SDNN and RMSSD. Late-gestation sows exhibited lower HF than both MID and NP sows (P < 0.0001), greater DFA values than NP sows (P = 0.05), and greater DET compared to MID sows (P = 0.001). Late-gestation also sows exhibited greater %REC and LMEAN compared to MID (P < 0.01) and NP sows (all P < 0.01). In conclusion, LATE sows exhibited indicators of greater autonomic stress throughout the heating period compared to MID and NP sows. However, temperature by treatment interactions were not detected as dry bulb increased. Future studies are needed to fully elucidate the effect of gestational stage and increasing dry bulb temperature on sow HRV.

Agriculture↗

Machine Learning in Infectious Disease for Risk Factor Identification and Hypothesis Generation: Proof of Concept Using Invasive Candidiasis

Machine learning (ML) models can handle large data sets without assuming underlying relationships and can be useful for evaluating disease characteristics, yet they are more commonly used for predicting individual disease risk than for identifying factors at the population level. We offer a proof of concept applying random forest (RF) algorithms to Candida-positive hospital encounters in an electronic health record database of patients in the United States. Candida-positive encounters were extracted from the Cerner HealthFacts database; invasive infections were laboratory-positive sterile site Candida infections. Features included demographics, admission source, care setting, physician specialty, diagnostic and procedure codes, and medications received before the first positive Candida culture. We used RF to assess risk factors for 3 outcomes: any invasive candidiasis (IC) vs non-IC, within-species IC vs non-IC (eg, invasive C. glabrata vs noninvasive C. glabrata), and between-species IC (eg, invasive C. glabrata vs all other IC). Fourteen of 169 (8%) variables were consistently identified as important features in the ML models. When evaluating within-species IC, for example, invasive C. glabrata vs non-invasive C. glabrata, we identified known features like central venous catheters, intensive care unit stay, and gastrointestinal operations. In contrast, important variables for invasive C. glabrata vs all other IC included renal disease and medications like diabetes therapeutics, cholesterol medications, and antiarrhythmics. Known and novel risk factors for IC were identified using ML, demonstrating the hypothesis-generating utility of this approach for infectious disease conditions about which less is known, specifically at the species level or for rarer diseases.

60 APPLIED LIFE SCIENCES↗

Nanoscale Defects as Probes of Time-Reversal Symmetry Breaking

Nanoscale defects such as nitrogen-vacancy (NV) centers can serve as sensitive and noninvasive probes of electromagnetic fields and fluctuations from materials, which in turn can be used to characterize these systems. Here we specifically discuss how NV centers can probe time-reversal symmetry breaking (TRSB) phenomena in low-dimensional electronic systems. We argue that the difference in relaxation rates Γ$_{±\hat{z}}$ of NV centers starting from 𝑚 = ±1 spin states to the ground state with 𝑚 = 0 directly probes TRSB. The effect arises from the difference in the fluctuation spectrum of left- and right-polarized electromagnetic fields emanating from such materials. In the quantum Hall setting, the NV center experiences (nearly zero) large additional contribution to its relaxation due to the presence of the material when its magnetic dipole (anti)aligns with the external field. More generally, the difference in the relaxation rates is sensitive to the imaginary part of the wave-vector-dependent Hall conductivity. We argue that this can be used to determine the Hall viscosity, which can potentially distinguish candidate fractional quantum Hall states and be used to infer the pairing angular momentum in TRSB superconductors. We compute the average relaxation rate [Γ$_{+\hat{z}}$ + Γ$_{-\hat{z}}$] near thin film superconductors and find that it exhibits a Hebel-Slichter-like enhancement below 𝑇 𝑐 . The difference Γ$_{+\hat{z}}$ −Γ$_{-\hat{z}}$ also inherits this peak but is only nonzero for 𝑇 < 𝑇 𝑐 and only if the superconductivity is chiral. We provide concrete estimates for observing this effect in stacked twisted bismuth strontium calcium copper oxide flakes.

NV centers↗

Improved laser-plasma accelerator stability via high-bandwidth longitudinal focal position stabilization of a 100 TW-class laser system

Laser-plasma accelerators (LPAs) offer an attractive alternative to conventional accelerators for the development of compact electron sources and next-generation light sources. Due to orders-of-magnitude larger accelerating gradients, LPAs enable the acceleration of high-brightness electron beams to ultrarelativistic energies in millimeter- to centimeter-scale distances. However, LPA stability is limited by shot-to-shot fluctuations of the driving laser system. Specifically, fluctuations in the final-focus longitudinal position result in correlated instability in LPA electron beam qualities, including total beam charge, average beam energy, and energy spread. We demonstrate active stabilization of the longitudinal focal position for a 100 TW-class laser system. This repetition-rate scalable stabilization system leverages noninvasive wave front monitoring of a copropagating, unamplified kHz pulse train to guide corrective adjustments to the focal position of a 1 Hz amplified drive laser via an upstream telescope on millisecond timescales. In this demonstration, the approach limits standard deviation fluctuations of the amplified drive beam’s longitudinal focal position to ±0.22⁢ mm (representing at least a 53% reduction), achieved with a correction bandwidth that reaches the Nyquist frequency limit. Consequently, we observe marked improvements in both long-term and shot-to-shot LPA stability in terms of charge and spectrum.

Beam control↗

Two-color x-ray free-electron laser by photocathode laser emittance spoiler

Multispectral x-ray pump-probe experiments call for synchronized two-color free-electron lasers (FEL). This mode often implies a laborious setup or an inefficient use of the undulator. We report on a simple and noninvasive approach tested at SwissFEL for a two-color x-ray delivering almost 60% of the pulse energy compared with a single color. In this new method, a ps UV pulse is overlapped to the photocathode drive laser increasing the beam emittance, which locally inhibits the FEL process. This scheme permits high-stability in energy and spectrum and the control of the two-color duration and intensity ratio. It enables shot-to-shot switching between one and two-color FEL and, since not associate to beam losses, it is compatible with high repetition-rate and high average-power FELs.

43 PARTICLE ACCELERATORS↗

Temperature Mapping of Stacked Silicon Dies from X-Ray-Diffraction Intensities

Increasing power densities in integrated circuits have led to an increased prevalence of thermal hotspots in integrated circuits. Tracking these thermal hotspots is imperative to prevent circuit failures. In three- dimensional (3D) integrated circuits, conventional surface techniques like infrared thermometry are unable to measure the 3D temperature distribution, and optical and magnetic resonance techniques are difficult to apply due to the presence of metals and large current densities. X-rays offer a high penetration depth and can be used to probe 3D structures. We report a method utilizing the temperature dependence of x-ray-diffraction intensity via the Debye-Waller factor to simultaneously map the temperature of individual silicon dies in a stack. Here, utilizing beamline 1-ID-E at the Advanced Photon Source (Argonne), we demonstrate, for each individual silicon die, a temperature resolution of 3 K, a spatial resolution of 100 × 400 μm 2 , and a temporal resolution of 20 s. Utilizing a sufficiently high-intensity laboratory source, e.g., from a liquid-anode source, this method can be scaled down to laboratories for noninvasive temperature mapping of 3D integrated circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling and experimental validation of dynamical effects in Bragg coherent x-ray diffractive imaging of finite crystals

Bragg coherent diffractive imaging (BCDI) is a noninvasive microscopy technique that can visualize the shape and internal lattice deviations of crystals with nanoscale spatial resolution and picometer deformation sensitivity. Its strain imaging capability relies on Fourier transform–based iterative phase retrieval algorithms, which are mostly developed under the kinematical approximation. Such approximation prohibits the application of BCDI on larger crystals, which are commonly seen in most emerging functional materials. Understanding the dynamical effect in BCDI, as well as developing a validated method for modeling BCDI at the dynamical diffraction limit, is crucial for applying BCDI to hierarchical systems that contain micron-sized crystals and grains. Thus we report a comparative study on the impact of dynamical diffraction effects by comparing the reconstruction results from two measurements of the same crystal. Forward simulation is implemented to show subtle changes of interference fringes in the diffraction pattern due to the dynamical diffraction, and is compared directly with the experimental data.

36 MATERIALS SCIENCE↗

Accessing the Spectral Function in a Current-Carrying Device

The presence of an electrical transport current in a material is one of the simplest and most important realizations of nonequilibrium physics. The current density breaks the crystalline symmetry and can give rise to dramatic phenomena, such as sliding charge density waves, insulator-to-metal transitions, or gap openings in topologically protected states. Almost nothing is known about how a current influences the electron spectral function, which characterizes most of the solid’s electronic, optical, and chemical properties. In this work, we show that angle-resolved photoemission spectroscopy with a nanoscale light spot provides not only a wealth of information on local equilibrium properties, but also opens the possibility to access the local nonequilibrium spectral function in the presence of a transport current. Unifying spectroscopic and transport measurements in this way allows simultaneous noninvasive local measurements of the composition, structure, many-body effects, and carrier mobility in the presence of high current densities. In the particular case of our graphene-based device, we are able to correlate the presence of structural defects with locally reduced carrier lifetimes in the spectral function and a locally reduced mobility with a spatial resolution of 500 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exotic silicon phases synthesized through ultrashort laser-induced microexplosion: Characterization with Raman microspectroscopy

Exotic metastable phases of silicon formed under high pressure are expected to have attractive semiconducting properties including narrow band gaps that open up novel technological applications. Confined microexplosions induced by powerful ultrashort laser pulses have been demonstrated as an advanced tool for the creation of new high-pressure phases that cannot be synthesized by other means. Tightly focused laser pulses are used to generate localized modifications inside the material structure, providing the possibility for precise controlled band-gap engineering. In this study, noninvasive Raman spectroscopy was used for analysis of laser-modified zones in silicon and to determine the metastable high-pressure phases contained. Low laser energies induced the formation of amorphous-only silicon, while higher energies led to crystalline silicon polymorphs within the modifications, albeit under considerable residual stress up to 4.5 GPa. The presence of the structurally similar r8-Si, bc8-Si, and bt8-Si phases is revealed, as well as other yet to be identified phases, and the stacking-related 9R Si polytype is evidenced, presumably stress-induced by the highly compressed laser-modified zone. The ab initio random structure searching approach is used to calculate the Raman signatures and to help identify different Si polymorphs. The findings of this study by Raman spectroscopy from ultrashort laser-induced microexplosion sites may yield insights into the local structure and properties of new silicon metastable phases and the prospect of utilizing exotic phases for extending current applications.

36 MATERIALS SCIENCE↗

Physics-constrained superresolution diffusion for six-dimensional phase space diagnostics

Adaptive physics-constrained superresolution diffusion is developed for noninvasive virtual diagnostics of the six-dimensional (6D) phase space density of charged particle beams. An adaptive variational autoencoder embeds initial beam condition images and scalar measurements to a low-dimensional latent space from which a 32 6 pixel 6D tensor representation of the beam's 6D phase space density is generated. Projecting from a 6D tensor generates physically consistent two-dimensional projections. Physics-guided superresolution diffusion transforms low-resolution images of the 6D density to high resolution 256 × 256 pixel images. Unsupervised adaptive latent space tuning enables tracking of time-varying beams without knowledge of time-varying initial conditions. The method is demonstrated with experimental data and multiparticle simulations at the HiRES UED. The general approach is applicable to a wide range of complex dynamic systems evolving in high-dimensional phase space. The method is shown to be robust to distribution shift without retraining. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Quantum imaging with positronium-decay-emitted gamma rays

The use of entangled gamma rays from positronium decay for quantum-enhanced imaging of dense materials is demonstrated. Quantum ghost images, where only one of the entangled 511-keV photons interacts with the object, are obtained for tantalum samples of varying density using a 210-ps time-resolution dual detector system and a Na-22 positron source. An analysis comparing both classical and quantum imaging modalities is employed to isolate true 511-keV events from background noise. Image quality is quantitatively assessed using transmission ratios and the Michelson contrast. Quantum-correlated images are found to exhibit superior (up to approximately 1.7x, from 0.49 to 0.83 in the thickest sample measured) contrast compared to classical methods and align well with theoretical expectations. These results suggest that quantum ghost imaging with positronium-based entangled gamma rays could significantly enhance noninvasive imaging of high-density objects, with potential applications in areas such as cargo inspection and security screening.

36 MATERIALS SCIENCE↗

Phase-contrast 3D tomography of HeLa cells grown in PLLA polymer electrospun scaffolds using synchrotron X-rays

Advanced imaging is useful for understanding the three-dimensional (3D) growth of cells. X-ray tomography serves as a powerful noninvasive, nondestructive technique that can fulfill these purposes by providing information about cell growth within 3D platforms. There are a limited number of studies taking advantage of synchrotron X-rays, which provides a large field of view and suitable resolution to image cells within specific biomaterials. In this study, X-ray synchrotron radiation microtomography at Diamond Light Source and advanced image processing were used to investigate cellular infiltration of HeLa cells within poly L-lactide (PLLA) scaffolds. This study demonstrates that synchrotron X-rays using phase contrast is a useful method to understand the 3D growth of cells in PLLA electrospun scaffolds. Two different fiber diameter (2 and 4 µm) scaffolds with different pore sizes, grown over 2, 5 and 8 days in vitro , were examined for infiltration and cell connectivity. After performing visualization by segmentation of the cells from the fibers, the results clearly show deeper cell growth and higher cellular interconnectivity in the 4 µm fiber diameter scaffold. Finally, this indicates the potential for using such 3D technology to study cell–scaffold interactions for future medical use.

3D culture↗