Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear physics detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

SAFEGUARDS ENVELOPE: PREVIOUS WORK AND EXAMPLES

The future expansion of nuclear power will require not just electricity production but fuel cycle facilities such as fuel fabrication and reprocessing plants. As large reprocessing facilities are built in various states, they must be built and operated in a manner to minimize the risk of nuclear proliferation. Process monitoring has returned to the spotlight as an added measure that can increase confidence in the safeguards of special nuclear material (SNM). Process monitoring can be demonstrated to lengthen the allowable inventory period by reducing accountancy requirements, and to reduce the false positive indications. The next logical step is the creation of a Safeguards Envelope, a set of operational parameters and models to maximize anomaly detection and inventory period by process monitoring while minimizing operator impact and false positive rates. A brief example of a rudimentary Safeguards Envelope is presented, and shown to detect synthetic diversions overlaying a measured processing plant data set. This demonstration Safeguards Envelope is shown to increase the confidence that no SNM has been diverted with minimal operator impact, even though it is based on an information sparse environment. While the foundation on which a full Safeguards Envelope can be built has been presented in historical demonstrations of process monitoring, several requirements remain yet unfulfilled. Future work will require reprocessing plant transient models, inclusion of “non-traditional” operating data, and exploration of new methods of identifying subtle events in transient processes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Safeguards Envelope Progress FY10

The Safeguards Envelope is a strategy to determine a set of specific operating parameters within which nuclear facilities may operate to maximize safeguards effectiveness without sacrificing safety or plant efficiency. This paper details the additions to the advanced operating techniques that will be applied to real plant process monitoring (PM) data from the Idaho Chemical Processing Plant (ICPP). Research this year focused on combining disparate pieces of data together to maximize operating time with minimal downtime due to safeguards. A Chi-Square and Croiser's cumulative sum were both included as part of the new analysis. Because of a major issue with the original data, the implementation of the two new tests did not add to the existing set of tests, though limited one-variable optimization made a small increase in detection probability. Additional analysis was performed to determine if prior analysis would have caused a major security or safety operating envelope issue. It was determined that a safety issue would have resulted from the prior research, but that the security may have been increased under certain conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Optimizing moderation of He-3 neutron detectors for shielded fission sources

Abstract: The response of 3-He neutron detectors is highly dependent on the amount of moderator incorporated into the detector system. If there is too little moderation, neutrons will not react with the 3-He. If there is too much moderation, neutrons will not reach the 3-He. In applications for portal or border monitors where 3He detectors are used to interdict illicit Importation of plutonium, the fission source is always shielded to some extent. Since the energy distribution of neutrons emitted from the source depends on the amount and type of shielding present, the optimum placement of moderating material around 3-He tubes is a function of shielding. In this paper, we use Monte Carlo techniques to model the response of 3-He tubes placed in polyethylene boxes for moderation. To model the shielded fission neutron source, we use a 252-Cf source placed in the center of spheres of water of varying radius. Detector efficiency as a function of box geometry and shielding are explored. We find that increasing the amount of moderator behind and to the sides of the detector generally improves the detector response, but that benefits are limited if the thickness of the polyethylene moderator is greater than about 5-7 cm. The thickness of the moderator in front of the 3He tubes, however, is very important. For bare sources, about 5-6 cm of moderator is optimum, but as the shielding increases, the optimum thickness of this moderator decreases to 0-1 cm. A two-tube box with a moderator thickness of 5 cm in front of the first tube and a thickness of 1 cm in front of the second tube is proposed to improve the detector's sensitivity to lower-energy neutrons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematic evaluation of fast neutron sensing with Cesium Hafnium Chloride

Cesium Hafnium Chloride (CHC) is a promising new scintillator for dual mode sensing of both neutrons and gamma-rays. The high chlorine content allows for both 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reaction channels leading to reliable detection of fast neutrons. By utilizing pulse shape discrimination (PSD), these neutron interactions may be reliably separated from gamma-ray signals with a high figure-of-merit (FOM) after optimization of the PSD algorithm. Here, in this study, the PSD algorithm settings for CHC were systematically investigated using a bare 252 Cf and a lead shielded plutonium beryllium neutron source. It was found that the PSD algorithm settings affects both the FOM and the neutron detection efficiency, but a FOM as high as 4.5 for alpha particles was observed in one data processing scenario. Further, an intrinsic 5 parts per million alpha emitting contamination was observed in the sample, which we attribute to natural uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COE1 Calorimeter Operations Manual

The purpose of this manual is to describe the operations of the COE1 calorimeter which is used to measure the thermal power generated by the radioactive decay of plutonium-bearing materials for the purposes of assaying the amount of plutonium within the material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear physics detector technology applied to plant biology research

The ability to detect the emissions of radioactive isotopes through radioactive decay (e.g. beta particles, x-rays and gamma-rays) has been used for over 80 years as a tracer method for studying natural phenomena. More recently a positron emitting radioisotope of carbon: {sup 11}C has been utilized as a {sup 11}CO{sub 2} tracer for plant ecophysiology research. Because of its ease of incorporation into the plant via photosynthesis, the {sup 11}CO{sub 2} radiotracer is a powerful tool for use in plant biology research. Positron emission tomography (PET) imaging has been used to study carbon transport in live plants using {sup 11}CO{sub 2}. Presently there are several groups developing and using new PET instrumentation for plant based studies. Thomas Jefferson National Accelerator Facility (Jefferson Lab) in collaboration with the Duke University Phytotron and the Triangle Universities Nuclear Laboratory (TUNL) is involved in PET detector development for plant imaging utilizing technologies developed for nuclear physics research. The latest developments of the use of a LYSO scintillator based PET detector system for {sup 11}CO{sub 2} tracer studies in plants will be briefly outlined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metabonomics for detection of nuclear materials processing.

Tracking nuclear materials production and processing, particularly covert operations, is a key national security concern, given that nuclear materials processing can be a signature of nuclear weapons activities by US adversaries. Covert trafficking can also result in homeland security threats, most notably allowing terrorists to assemble devices such as dirty bombs. Existing methods depend on isotope analysis and do not necessarily detect chronic low-level exposure. In this project, indigenous organisms such as plants, small mammals, and bacteria are utilized as living sensors for the presence of chemicals used in nuclear materials processing. Such 'metabolic fingerprinting' (or 'metabonomics') employs nuclear magnetic resonance (NMR) spectroscopy to assess alterations in organismal metabolism provoked by the environmental presence of nuclear materials processing, for example the tributyl phosphate employed in the processing of spent reactor fuel rods to extract and purify uranium and plutonium for weaponization.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Physical Protection Systems Test Bed for International Counter-Trafficking System Development

Physical protection systems have a widespread impact on the nuclear industry in areas such as nuclear safeguards, arms control, and trafficking of illicit goods (e.g., nuclear materials) across international borders around the world. Many challenges must be overcome in design and deployment of foreign border security systems such as lack of infrastructure, extreme environmental conditions, limited knowledge of terrain, insider threats, and occasional cultural resistance. Successful security systems, whether it be a system designed to secure a single facility or a whole border security system, rely on the entire integrated system composed of multiple subsystems. This test bed is composed of many unique sensors and subsystems, including wireless unattended ground sensors, a buried fiber-optic acoustic sensor, a lossy coaxial distributed sensor, wireless links, pan-tilt-zoom cameras, mobile power generation systems, unmanned aerial vehicles, and fiber-optic-fence intrusion detection systems. A Common Operating Picture software architecture is utilized to integrate a number of these subsystems. We are currently performance testing each system for border security and perimeter security applications by examining metrics such as probability of sense and a qualitative understanding of the sensor s vulnerability of defeat. The testing process includes different soil conditions for buried sensors (e.g., dry, wet, and frozen) and an array of different tests including walking, running, stealth detection, and vehicle detection. Also, long term sustainability of systems is tested including performance differences due to seasonal variations (e.g. summer versus winter, while raining, in foggy conditions). The capabilities of the test bed are discussed. Performance testing results, both at the individual component level and integrated into a larger system for a specific deployment (in situ), help illustrate the usefulness and need for integrated testing facilities to carry out this mission. The test bed provides access to grassy fields, wooded areas, and a large waterway three distinct testing environments. The infrastructure supporting deployment of systems at the test bed includes grid power, renewable power systems, climate controlled enclosures, high bandwidth wireless links, and a fiber optic communications backbone. With over 10 acres of dedicated area and direct waterway access, the test bed is well suited for long term test and evaluation of physical protection and security systems targeting a wide range of applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Codes for "Shallow Soil Response to a Buried Chemical Explosion with Geophones and Distributed Acoustic Sensing" DAG - 01101646

The codes reproduce the figures of the manuscript entitled "Shallow Soil Response to a Buried Chemical Explosion with Geophones and Distributed Acoustic Sensing" submitted to Journal of Geophysical Research - Solid Earth. Geophone data and Distributed acoustic sensing (DAS) data recorded during the Phase II of the The Source Physics Experiment (SPE) along a fiber-optic cable offshore were processed to understand the response of the shallow subsurface to an explosion. This Ground-based Nuclear Detonation Detection (GNDD), Low Yield Nuclear Monitoring (LYNM), and Source Physics Experiment (SPE) research was funded by the National Nuclear Security Administration, Defense Nuclear Nonproliferation Research and Development (NNSA DNN R&D).

Viens, Loic↗

Use of Data Libraries for IAEA Nuclear Security Assessment Methodologies (NUSAM) [section 5.4]

Data libraries are essential for the characterization of the facility and provide the documented input which enables the facility assessment results and subsequent conclusions. Data Libraries are historical, verifiable, quantified, and applicable collections of testing data on different types of barriers, sensors, cameras, procedures, and/or personnel. Data libraries are developed and maintained as part of any assessment program or process. Data is collected during the initial stages of facility characterization to aid in the model and/or simulation development process. Data library values may also be developed through the use of state testing centers and/or site resources by testing different types of barriers, sensors, cameras, procedures, and/or personnel. If no data exists, subject matter expert opinion and manufacturer's specifications/ testing values can be the basis for initially assigning values, but are generally less reliable and lack appropriate confidence measures. The use of existing data libraries that have been developed by a state testing organization reduces the assessment costs by establishing standard delay, detection and assessment values for use by multiple sites or facilities where common barriers and alarms systems exist.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of a phoswich detector system for radioxenon monitoring

Abstract Measurement of radioactive xenon in the atmosphere is one of several techniques to detect nuclear weapons testing. For high sensitivity, some existing systems use beta/gamma coincidence detection to suppress background, which is very effective, but increases complexity due to separate beta and gamma detectors that require careful calibration and gain matching. In this paper, we will describe the development and evaluation of a simpler detector system, named PhosWatch, consisting of a CsI(Tl)/ BC-404 phoswich well detector, digital readout electronics, and pulse shape analysis algorithms implemented in a digital signal processor on the electronics, and compare its performance to existing multi-detector systems.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A NEW ALGORITHM FOR RADIOISOTOPE IDENTIFICATION OF SHIELDED AND MASKED SNM/RDD MATERIALS

Detection and identification of shielded and masked nuclear materials is crucial to national security, but vast borders and high volumes of traffic impose stringent requirements for practical detection systems. Such tools must be be mobile, and hence low power, provide a low false alarm rate, and be sufficiently robust to be operable by non-technical personnel. Currently fielded systems have not achieved all of these requirements simultaneously. Transport modeling such as that done in GADRAS is able to predict observed spectra to a high degree of fidelity; our research is focusing on a radionuclide identification algorithm that inverts this modeling within the constraints imposed by a handheld device. Key components of this work include incorporation of uncertainty as a function of both the background radiation estimate and the hypothesized sources, dimensionality reduction, and nonnegative matrix factorization. We have partially evaluated performance of our algorithm on a third-party data collection made with two different sodium iodide detection devices. Initial results indicate, with caveats, that our algorithm performs as good as or better than the on-board identification algorithms. The system developed was based on a probabilistic approach with an improved approach to variance modeling relative to past work. This system was chosen based on technical innovation and system performance over algorithms developed at two competing research institutions. One key outcome of this probabilistic approach was the development of an intuitive measure of confidence which was indeed useful enough that a classification algorithm was developed based around alarming on high confidence targets. This paper will present and discuss results of this novel approach to accurately identifying shielded or masked radioisotopes with radiation detection systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron counting and gamma spectroscopy with PVT detectors.

Radiation portals normally incorporate a dedicated neutron counter and a gamma-ray detector with at least some spectroscopic capability. This paper describes the design and presents characterization data for a detection system called PVT-NG, which uses large polyvinyl toluene (PVT) detectors to monitor both types of radiation. The detector material is surrounded by polyvinyl chloride (PVC), which emits high-energy gamma rays following neutron capture reactions. Assessments based on high-energy gamma rays are well suited for the detection of neutron sources, particularly in border security applications, because few isotopes in the normal stream of commerce have significant gamma ray yields above 3 MeV. Therefore, an increased count rate for high-energy gamma rays is a strong indicator for the presence of a neutron source. The sensitivity of the PVT-NG sensor to bare {sup 252}Cf is 1.9 counts per second per nanogram (cps/ng) and the sensitivity for {sup 252}Cf surrounded by 2.5 cm of polyethylene is 2.3 cps/ng. The PVT-NG sensor is a proof-of-principal sensor that was not fully optimized. The neutron detector sensitivity could be improved, for instance, by using additional moderator. The PVT-NG detectors and associated electronics are designed to provide improved resolution, gain stability, and performance at high-count rates relative to PVT detectors in typical radiation portals. As well as addressing the needs for neutron detection, these characteristics are also desirable for analysis of the gamma-ray spectra. Accurate isotope identification results were obtained despite the common impression that the absence of photopeaks makes data collected by PVT detectors unsuitable for spectroscopic analysis. The PVT detectors in the PVT-NG unit are used for both gamma-ray and neutron detection, so the sensitive volume exceeds the volume of the detection elements in portals that use dedicated components to detect each type of radiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultra Wide Band RFID Neutron Tags for Nuclear Materials Monitoring

Recent advancements in the ultra-wide band Radio Frequency Identification (RFID) technology and solid state pillar type neutron detectors have enabled us to move forward in combining both technologies for advanced neutron monitoring. The LLNL RFID tag is totally passive and will operate indefinitely without the need for batteries. The tag is compact, can be directly mounted on metal, and has high performance in dense and cluttered environments. The LLNL coin-sized pillar solid state neutron detector has achieved a thermal neutron detection efficiency of 20% and neutron/gamma discrimination of 1E5. These performance values are comparable to a fieldable {sup 3}He based detector. In this paper we will discuss features about the two technologies and some potential applications for the advanced safeguarding of nuclear materials.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Stand-alone and Network Capable Pocket Radiation Detection System

A multi-functional and networked pocket radiation detection system has been developed at the Idaho National Laboratory (INL) capable of detecting and storing gamma ray and neutron data. The device can be used as a stand-alone device or in conjunction with an array to cover a small or large area. The device has programmable alarm trigger levels that can be modified for specific applications. The data is stored with a date/time stamp and can be transferred and viewed on a PDA via direct connection or, in networked configuration, wireless connection to a remote central facility upon request. Data functional/bench tests have been completed successfully and the device was demonstrated to detect radiation from a 55.6 uCi Cf-252 source at 5 meters and from 1.4 mCi Cf-252 source at 10 meters which exceeds both ANSI and IAEA standards for pocket radiation detection. In terms of sensitivity, this detection system detects neutron and gamma-ray fields down to 10 micro rem/hr levels and therefore can find the location of the radioactive source quickly. The detection system is small enough to be put in a pocket or clipped to a belt.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laying the Foundation for a Predictive Theory of Electroweak Nuclear Phenomena

Reliable model-independent predictions of nuclear processes such as beta-decay and neutrinonucleus scattering are important for many fundamental science and mission-related investigations; For example, accurate descriptions of as beta-decay are required for modeling the anti-neutrino spectrum of nuclear reactor, whether for trying to detect new physics such as sterile neutrinos, or remotely identifying the purpose of that reactor. For these activities, we need accurate calculations, as well as careful and thorough analyses of theoretical error and uncertainty in the underlying models and the many-body methods and codes used in solving that model. Unfortunately, modern theoretical calculations of these processes are inadequate for this task. At the heart of this inadequacy is the interaction between nucleons and other particles known as nuclear currents. Historically, descriptions of nuclear currents took into account only the simplest of particle interactions. Recently, the development of an effective field theory known as chiral EFT has been used to derive large corrections to these particle interactions. However, the complex nature of these corrections inhibited their use in ab initio methods of predicting nuclear processes. We developed a novel method to address these complexities and applied it in a series of benchmark and demonstrative calculations using state-of-the-art quantum few-nucleon solvers. Specifically, we studied the role of two-nucleon currents in electroweak processes using light nuclei (i.e., nuclei containing fewer than five nucleons) as a workbench to compute these processes and quantify their uncertainties using Bayesian extensions of the EFT.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large-scale shell-model calculations of elastic and inelastic scattering rates of lightest supersymmetric particles (LSP) on {sup 127}I, {sup 129}Xe, {sup 131}Xe, and {sup 133}Cs nuclei

We discuss the dark-matter detection rates for the elastic and inelastic scattering of the lightest supersymmetric particle (LSP) off nuclei. For this we use an easily accessible formalism where the underlying nuclear physics is condensed in structure coefficients multiplying the key parameters of supersymmetric theories. In this work we compute these coefficients for the stable iodine, xenon, and cesium nuclei by application of the nuclear shell model in a model space involving the 2s, 1d, 0g{sub 7/2}, and 0h{sub 11/2} single-particle orbitals. As an interaction we use the renormalized Bonn-CD G matrix. By using fitted nuclear gyromagnetic factors we have successfully reproduced the relevant spectroscopic data on magnetic moments and M1 decays in the discussed nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗